Is there an alternative to systemic anticoagulation, as related to interventional biomedical devices?

Abstract:

:To reduce the toxic effects, related clinical problems and complications such as bleeding disorders associated with systemic anticoagulation, it has been hypothesized that by coating the surfaces of medical devices, such as stents, bypass grafts, extracorporeal circuits, guide wires and catheters, there will be a significant reduction in the requirement for systemic anticoagulation or, ideally, it will no longer be necessary. However, current coating processes, even covalent ones, still result in leaching followed by reduced functionality. Alternative anticoagulants and related antiplatelet agents have been used for improvement in terms of reduced restenosis, intimal hyperphasia and device failure. This review focuses on existing heparinization processes, their application in clinical devices and the updated list of alternatives to heparinization in order to obtain a broad overview, it then highlights, in particular, the future possibilities of using heparin and related moieties to tissue engineer scaffolds.

journal_name

Expert Rev Med Devices

authors

Conn G,Kidane AG,Punshon G,Kannan RY,Hamilton G,Seifalian AM

doi

10.1586/17434440.3.2.245

keywords:

subject

Has Abstract

pub_date

2006-03-01 00:00:00

pages

245-61

issue

2

eissn

1743-4440

issn

1745-2422

journal_volume

3

pub_type

杂志文章
  • Is there an optimal interventional device for the salvage of thrombosed native angioaccess for hemodialysis?

    abstract::The rescue of autogenous angioaccess for hemodialysis can be performed surgically or radiologically. For the latter, there is current debate as to whether a mechanical hydrodynamic device confers a clinical advantage over a rotational thrombectomy. The evaluated article describes a single center retrospective cohort s...

    journal_title:Expert review of medical devices

    pub_type: 评论,杂志文章

    doi:10.1586/erd.12.75

    authors: Hossain MA,Chung R,Frampton AE,Chemla ES

    更新日期:2013-01-01 00:00:00

  • Update on the management and associated challenges of adult patients treated with veno-arterial extracorporeal membrane oxygenation.

    abstract:INTRODUCTION:Currently, veno-arterial extracorporeal membrane oxygenation (VA ECMO) represents a valuable treatment option for patients presenting with severe cardiogenic shock. Although the overall usage of VA ECMO in experienced centers is expanding, some management aspects remain challenging, with no consensus among...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1614439

    authors: Kado Y,Miyamoto T,Fukamachi K,Karimov JH

    更新日期:2019-06-01 00:00:00

  • Stent placement for esophageal strictures: an update.

    abstract::The use of stents for esophageal strictures has evolved rapidly over the past 10 years, from rigid plastic tubes to flexible self-expanding metal (SEMS), plastic (SEPS) and biodegradable stents. For the palliative treatment of malignant dysphagia both SEMS and SEPS effectively provide a rapid relief of dysphagia. SEMS...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.44

    authors: Hirdes MM,Vleggaar FP,Siersema PD

    更新日期:2011-11-01 00:00:00

  • Female sterilization.

    abstract::There has been considerable development and implementation of new contraceptive methods over the last 15 years. However, sterilization has remained the most widely used method around the world. Ideally, the procedure should be safe, have a high efficacy, be readily accessible, and be personally and culturally acceptab...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.4.525

    authors: Chapman L,Magos A

    更新日期:2008-07-01 00:00:00

  • Currently available metacarpophalangeal prostheses: their designs and prospective considerations.

    abstract::Although implanted for over 40 years, finger prostheses have failed to match the success achieved by artificial hip and knee prostheses, despite a myriad of designs having been proposed and implanted. This article looks at the currently available designs of metacarpophalangeal prosthesis, both single-piece and multico...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.1.2.193

    authors: Joyce TJ

    更新日期:2004-11-01 00:00:00

  • The EluNIRTM Ridaforolimus Eluting Coronary Stent System.

    abstract:INTRODUCTION:First-generation drug-eluting stents (DES) were developed and indeed proved their superiority compared to bare-metal stent in minimizing neo-intimal hyperplasia and in-stent restenosis (ISR), overall, reducing target vessel revascularization (TVR). Newer-generation DES are characterized by thinner struts, ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1549986

    authors: Savvoulidis P,Perlman G,Bagur R

    更新日期:2019-01-01 00:00:00

  • The challenges surrounding preclinical testing in transcatheter device development and the implications on the clinic.

    abstract:INTRODUCTION:Transcatheter devices have contributed significantly to the advances achieved in treating many cardiovascular conditions over the last few decades. Sophisticated and detailed preclinical testing is not only a regulatory requirement to support an investigational device exemption (IDE) application, but more ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2017.1282313

    authors: Holzer R,Goble J,Hijazi Z

    更新日期:2017-02-01 00:00:00

  • The RNS System: responsive cortical stimulation for the treatment of refractory partial epilepsy.

    abstract::The RNS(®) System is the first commercially available device to provide closed-loop responsive brain stimulation. The system includes a cranially implanted neurostimulator that continually monitors the electrocorticogram through one or two depth and/or subdural cortical strip leads that are placed at the seizure focus...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.947274

    authors: Sun FT,Morrell MJ

    更新日期:2014-11-01 00:00:00

  • The Visible Heart® project and methodologies: novel use for studying cardiac monophasic action potentials and evaluating their underlying mechanisms.

    abstract:INTRODUCTION:This review describes the utilization of Visible Heart® methodologies for electrophysiologic studies, specifically in the investigation of monophasic action potential (MAP) recordings, with the aim to facilitate new catheter/device design and development that may lead to earlier diagnosis, treatment, and u...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1493922

    authors: Schmidt MM,Iaizzo PA

    更新日期:2018-07-01 00:00:00

  • Anti-infective therapy with an Er:YAG laser: influence on peri-implant healing.

    abstract::In addition to conventional treatment modalities (mechanical and chemical), the use of lasers has been increasingly proposed for the treatment of periodontal and peri-implant infections (i.e., cleaning and detoxification of implant surfaces). Preliminary results from basic studies have pointed to the high potential of...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.3.267

    authors: Sculean A,Schwarz F,Becker J

    更新日期:2005-05-01 00:00:00

  • Endoscopy-guided vitreoretinal surgery.

    abstract::Vitreoretinal surgery has recently undergone remarkable developments. The introduction of micro-incision vitrectomy surgery using 25- and 23-gauge techniques has led to minimally invasive, faster, safer, and more accurate surgeries. Similarly, intraocular illumination and observation systems have advanced from light p...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.882226

    authors: Kawashima S,Kawashima M,Tsubota K

    更新日期:2014-03-01 00:00:00

  • Current interventional coronary applications of excimer laser.

    abstract::Excimer laser utilization as an adjunctive device for percutaneous coronary intervention has increased in the last few years. Many technical advancements have led to better results in terms of efficacy and safety with a low complication rate. In particular, excimer laser for thrombus-containing lesions is able to achi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.811846

    authors: Fracassi F,Roberto M,Niccoli G

    更新日期:2013-07-01 00:00:00

  • The role of active middle-ear implants in the rehabilitation of hearing loss.

    abstract::The surgical implantation of auditory devices to improve or restore the sensation of hearing in affected individuals is a rapidly growing area of modern ear, nose and throat, and audiological practice. Following the enormous success of cochlear implantation and set to take an increasing role in the rehabilitation of d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.18

    authors: Green K

    更新日期:2011-07-01 00:00:00

  • Scaffolds for liver tissue engineering.

    abstract::This review focuses on the expanding role for biomaterials and polymer scaffolds in liver tissue engineering. Studies are subdivided into in vitro and in vivo approaches. The in vitro section of the review discusses the challenges specific to liver tissue engineering, and how the choice of scaffold and its structure i...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.1.21

    authors: Hammond JS,Beckingham IJ,Shakesheff KM

    更新日期:2006-01-01 00:00:00

  • Intrasaccular flow-diversion for treatment of intracranial aneurysms: the Woven EndoBridge.

    abstract::Endovascular approach is now the first option for the treatment of most intracranial aneurysms (IA). However, remaining limitations are the suboptimal stability of aneurysm occlusion and the treatment of complex IA. The use of conventional and flow diverter stents has partially addressed these limitations. Nevertheles...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.907741

    authors: Mine B,Pierot L,Lubicz B

    更新日期:2014-05-01 00:00:00

  • What can be done for cerebral embolic protection in TAVI? Analysis in the light of 10 years' experience with protected carotid artery stenting.

    abstract::In the last 30 years, development of minimally invasive percutaneous procedures to treat cardiovascular defects has been thriving. Although these techniques present obvious advantages, like avoiding cardiopulmonary bypass, the passage of catheter systems and the deployment of devices in the blood circulation can cause...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1120666

    authors: Egron S,Kütting M,Marzelle J,Becquemin JP,Schmitz-Rode T,Steinseifer U

    更新日期:2016-01-01 00:00:00

  • Surgical drilling of curved holes in bone - a patent review.

    abstract:INTRODUCTION:Conventional surgical drills are rigid straight instruments used to make holes in bones. They lack the ability to follow a curved pathway, making them impractical for several surgical procedures. For this reason, there is a continuous need for improved devices for surgical drilling of curved holes. AREAS ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1596794

    authors: Sendrowicz A,Scali M,Culmone C,Breedveld P

    更新日期:2019-04-01 00:00:00

  • Non-invasive assessment of gestational hemodynamics: benefits and limitations of impedance cardiography versus other techniques.

    abstract::To obtain data for maternal stroke volume and cardiac output during pregnancy, it is preferable to use a non-invasive, accurate and reproducible method. In this aspect, impedance cardiography is an excellent technique which is also highly accessible and easy to perform. This paper is a comprehensive review on the publ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.853466

    authors: Staelens A,Tomsin K,Grieten L,Oben J,Mesens T,Spaanderman M,Jacquemyn Y,Gyselaers W

    更新日期:2013-11-01 00:00:00

  • Pentax confocal endomicroscope: a novel imaging device for in vivo histology of the upper and lower gastrointestinal tract.

    abstract::With advances in endoscopic imaging tools, it is becoming increasingly possible to find, assess and treat numerous gastrointestinal (GI) pathologies at the time of endoscopy. This article focuses on the newly developed Pentax confocal endomicroscope that enables in vivo microscopic imaging of the upper and lower GI tr...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.3.5.549

    authors: Polglase AL,McLaren WJ,Delaney PM

    更新日期:2006-09-01 00:00:00

  • A clinical update on the mid-term clinical performance of the Ovation endograft.

    abstract:INTRODUCTION:The Ovation stent-graft uncouples the steps of fixation and sealing via a pair of polymer-filled inflatable rings. Apart from the well-documented early results, newer data emerged for mid-term results of Ovation and are presented in this review. AREAS COVERED:Aim of this article was to report all current ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1555467

    authors: Koutsoumpelis A,Georgakarakos E,Tasopoulou KM,Kontopodis N,Argyriou C,Georgiadis GS

    更新日期:2019-01-01 00:00:00

  • Designing medical technology for resilience: integrating health economics and human factors approaches.

    abstract:INTRODUCTION:The slow adoption of innovation into healthcare calls into question the manner of evidence generation for medical technology. This paper identifies potential reasons for this including a lack of attention to human factors, poor evaluation of economic benefits, lack of understanding of the existing healthca...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1418661

    authors: Borsci S,Uchegbu I,Buckle P,Ni Z,Walne S,Hanna GB

    更新日期:2018-01-01 00:00:00

  • Differential effects of public and private funding in the medical device industry.

    abstract:INTRODUCTION:Funding for scientific advancement comes from two dominant sources: public funds used to generate knowledge, and private sector funds in the pursuit of commercial products. It is unclear how to compare the outputs of these two financial mechanisms because both sectors are motivated by common goods but are ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1419866

    authors: Kang HD,Edelman ER,Ku DN

    更新日期:2018-02-01 00:00:00

  • From drug eluting stents to bioresorbable scaffolds; to new horizons in PCI.

    abstract::Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir technology planting the ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143356

    authors: Tenekecioglu E,Bourantas C,Abdelghani M,Zeng Y,Silva RC,Tateishi H,Sotomi Y,Onuma Y,Yılmaz M,Serruys PW

    更新日期:2016-01-01 00:00:00

  • Crux vena cava filter.

    abstract::Inferior vena cava filters are widely accepted for pulmonary embolic prophylaxis in high-risk patients with contraindications to anticoagulation. While long-term complications have been associated with permanent filters, retrievable filters are now available and have resulted in the rapid expansion of this technology....

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/erd.09.25

    authors: Murphy EH,Johnson ED,Kopchok GE,Fogarty TJ,Arko FR

    更新日期:2009-09-01 00:00:00

  • Potential of APDM mobility lab for the monitoring of the progression of Parkinson's disease.

    abstract::APDM's Mobility Lab system provides portable, validated, reliable, objective measures of balance and gait that are sensitive to Parkinson's disease (PD). In this review, we describe the potential of objective measures collected with the Mobility Lab system for tracking longitudinal progression of PD. Balance and gait ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1153421

    authors: Mancini M,Horak FB

    更新日期:2016-05-01 00:00:00

  • Wearable inertial sensors for human movement analysis.

    abstract:INTRODUCTION:The present review aims to provide an overview of the most common uses of wearable inertial sensors in the field of clinical human movement analysis. AREAS COVERED:Six main areas of application are analysed: gait analysis, stabilometry, instrumented clinical tests, upper body mobility assessment, daily-li...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1198694

    authors: Iosa M,Picerno P,Paolucci S,Morone G

    更新日期:2016-07-01 00:00:00

  • New developments in the delivery of cardiac resynchronization therapy: targeted lead placement, multi-site and endocardial pacing.

    abstract::Cardiac resynchronization therapy (CRT) is a proven treatment adjunct for selected patients with heart failure and evidence of ventricular dyssynchrony. When applying most contemporary guidelines the accepted response rate has remained static with up to one-third of patients failing to respond. Empiric lateral/postero...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.885320

    authors: Sohal M,Chen Z,Sammut E,Jackson T,Behar J,Carr-White G,Razavi R,Rinaldi CA

    更新日期:2014-05-01 00:00:00

  • Use of Amplatzer occluders for treatment of aorto-pulmonary fistulas - case and review of the literature.

    abstract:INTRODUCTION:the use of amplatzer occluder family in daily clinical practice has already overcome on-label indications, with growing clinical experience and the technological evolution of devices. Areas covered: We present the case of a patient with a very rare complication following proximal aortic surgery treated usi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1389636

    authors: Toušek P,Kočka V,Petr R,Ulman J,Hlavička J,Kolesár M

    更新日期:2017-11-01 00:00:00

  • Scientific evidence for the use of modern patellofemoral arthroplasty.

    abstract::Patellofemoral arthroplasty has been utilized as a treatment for isolated patellofemoral arthritis for more than 30 years. However, the use of this procedure remains controversial, as many surgeons prefer to use total knee arthroplasty, even for isolated patellofemoral arthritis. While historically, the results with t...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/erd.09.53

    authors: Gupta RR,Zywiel MG,Leadbetter WB,Bonutti P,Mont MA

    更新日期:2010-01-01 00:00:00

  • Evolution of endovascular stroke therapies and devices.

    abstract::Acute ischemic stroke is caused by occlusion of a cerebral artery, resulting in loss of brain tissue and neurologic deficits. However, a portion of the ischemic brain can be salvaged if blood flow is restored within an appropriate time frame. The past year has seen the publication of five positive randomized controlle...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143772

    authors: Wallace AN,Kansagra AP,McEachern J,Moran CJ,Cross DT 3rd,Derdeyn CP

    更新日期:2016-01-01 00:00:00