Abstract:
INTRODUCTION:the use of amplatzer occluder family in daily clinical practice has already overcome on-label indications, with growing clinical experience and the technological evolution of devices. Areas covered: We present the case of a patient with a very rare complication following proximal aortic surgery treated using a unique strategy. A huge pseudoaneurysm around an ascending aortic prosthesis ruptured into the right pulmonary artery. A hybrid treatment strategy consisting of percutaneous closure of the fistula followed by cardiosurgery was chosen due to the patient's poor haemodynamic condition. We also review current clinical experience of endovascular treatment of aortopulmonary fistulas by searching case reports in PubMed. Expert commentary: Closure of the APF using an Amplatzer occluder via the antegrade venous approach is feasible, and may improve the haemodynamic conditions and decrease the risk of subsequent cardiac surgery.
journal_name
Expert Rev Med Devicesjournal_title
Expert review of medical devicesauthors
Toušek P,Kočka V,Petr R,Ulman J,Hlavička J,Kolesár Mdoi
10.1080/17434440.2017.1389636subject
Has Abstractpub_date
2017-11-01 00:00:00pages
845-847issue
11eissn
1743-4440issn
1745-2422journal_volume
14pub_type
杂志文章,评审abstract::Transcatheter aortic valve implantation (TAVI) is a widely used intervention in patients who are at high risk or contraindicated for cardiac surgery. The procedure is technically feasible in most patients and has very good mid-term clinical outcomes. In this special report, we evaluated the long-term outcome after TAV...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1586/17434440.2015.1063994
更新日期:2015-01-01 00:00:00
abstract::Methotrexate (MTX) is the cornerstone of treatment for rheumatoid arthritis (RA), and is widely used both as first-line therapy and as an important component of long-term therapy. Although subcutaneous MTX is typically delivered orally, parenteral administration offers benefits with respect to tolerability and systemi...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2014.929492
更新日期:2014-09-01 00:00:00
abstract:INTRODUCTION:Improved survival following single ventricle palliation has led to a large population of patients with a univentricular circulation, many of whom develop heart failure. Increasing experience with ventricular assist devices (VAD) in children has paved the way for VAD support in those with failing univentric...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2017.1332523
更新日期:2017-06-01 00:00:00
abstract::Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir technology planting the ...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2016.1143356
更新日期:2016-01-01 00:00:00
abstract:INTRODUCTION:Transcatheter devices have contributed significantly to the advances achieved in treating many cardiovascular conditions over the last few decades. Sophisticated and detailed preclinical testing is not only a regulatory requirement to support an investigational device exemption (IDE) application, but more ...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2017.1282313
更新日期:2017-02-01 00:00:00
abstract:PURPOSE:To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS:A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was asse...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2020.1837623
更新日期:2020-11-01 00:00:00
abstract:INTRODUCTION:Since the advent of peritoneal dialysis (PD) in the 1970s, the principles of dialysis have changed little. In the coming decades, several major breakthroughs are expected. AREAS COVERED:Novel wearable and portable dialysis devices for both hemodialysis (HD) and PD are expected first. The HD devices could ...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2018.1462697
更新日期:2018-05-01 00:00:00
abstract::The surgical implantation of auditory devices to improve or restore the sensation of hearing in affected individuals is a rapidly growing area of modern ear, nose and throat, and audiological practice. Following the enormous success of cochlear implantation and set to take an increasing role in the rehabilitation of d...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/erd.11.18
更新日期:2011-07-01 00:00:00
abstract::The number of outpatient surgical procedures performed in hospitals, increases daily. In some countries, such as Italy, outpatient operations outnumber inpatient operations. The incidence of thyroid disorders and, in particular, the cancer forms, has been increasing sharply for many years in several countries. Even if...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.5.1.85
更新日期:2008-01-01 00:00:00
abstract::Introduction: A preexisting mechanical mitral valve (MMV) is thought to be a thrombogenic risk factor after continuous-flow left ventricular assist device (CF-LVAD) implantation. We sought to evaluate the management and outcomes of preexisting MMVs in patients following CF-LVAD implantation.Areas covered: An electroni...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2020.1754190
更新日期:2020-05-01 00:00:00
abstract::Transmyocardial revascularization, using the US FDA-approved holmium: yttrium-aluminum-garnet (Ho:YAG) laser system, is a surgical option for patients with debilitating angina caused by diffuse coronary artery disease in areas of the heart not amenable to complete revascularization using conventional treatments. Incre...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1586/17434440.3.2.137
更新日期:2006-03-01 00:00:00
abstract::The combination of T2-weighted MRI with functional MRI, including contrast-enhanced MRI, diffusion-weighted imaging and magnetic resonance spectroscopy, has been recognized as the most promising diagnostic modality for the detection and staging of localized prostate cancer. In spite of the relatively low predictive va...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/erd.10.24
更新日期:2010-07-01 00:00:00
abstract:INTRODUCTION:This review describes the utilization of Visible Heart® methodologies for electrophysiologic studies, specifically in the investigation of monophasic action potential (MAP) recordings, with the aim to facilitate new catheter/device design and development that may lead to earlier diagnosis, treatment, and u...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2018.1493922
更新日期:2018-07-01 00:00:00
abstract::Models are abstract representations of reality that are built, analyzed and manipulated to augment the understanding of that reality. They can either be mental or codified but, in both cases, they contribute to good decision-making by ensuring that the right people use the right information at the right time. In order...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/erd.12.36
更新日期:2012-09-01 00:00:00
abstract::The use of stents for esophageal strictures has evolved rapidly over the past 10 years, from rigid plastic tubes to flexible self-expanding metal (SEMS), plastic (SEPS) and biodegradable stents. For the palliative treatment of malignant dysphagia both SEMS and SEPS effectively provide a rapid relief of dysphagia. SEMS...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/erd.11.44
更新日期:2011-11-01 00:00:00
abstract:INTRODUCTION:Bronchoscopic lung volume reduction with endobronchial valves is a recently acknowledged treatment option in patients with severe emphysema and absence of interlobar collateral ventilation. In endobronchial valve treatment, implantation of one-way valves leads to deflation of a hyperinflated lung lobe. Mul...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2018.1538780
更新日期:2018-11-01 00:00:00
abstract::Total hip resurfacing has long been conceptually attractive to both surgeons and patients. However, historically it has been plagued by limited durability and marked acetabular bone loss. The recent development of wear-resistant bearings, such as metal-on-metal, has led to renewed interest in hip resurfacing in the or...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.3.6.755
更新日期:2006-11-01 00:00:00
abstract::Carotid stenosis is responsible for approximately 30% of strokes, and carotid endarterectomy is considered to be the gold-standard treatment. Carotid angioplasty and stenting (CAS) has been proposed as an alternative to surgery but the risk of neurological complications and brain embolism remains the major drawback to...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.5.5.591
更新日期:2008-09-01 00:00:00
abstract::Malignant biliary obstruction results in jaundice, often with symptoms that decrease the quality of life. Biliary stent placement has largely supplanted surgical bypass for palliation of malignant biliary obstruction. Traditional rigid plastic stents are commonly used, inexpensive and easily removed, although with lim...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/erd.10.36
更新日期:2010-09-01 00:00:00
abstract::Surgeons often encounter the challenge of treating acquired abdominal wall defects following abdominal surgery. The current standard of practice is to repair most defects using permanent synthetic mesh material. Mesh augments the strength of the weakened abdominal wall fascia and enables the hernia repair to be perfor...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.3.5.657
更新日期:2006-09-01 00:00:00
abstract:INTRODUCTION:Spinal cord stimulation has emerged as a state-of-the-art evidence-based treatment for chronic neuropathic pain and mixed nociceptive-neuropathic pain. In recent years, several newer devices and treatment algorithms have provided unique and effective ways of treating chronic pain by spinal cord stimulation...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2019.1567325
更新日期:2019-02-01 00:00:00
abstract:INTRODUCTION:Hearing-assistive devices, such as hearing aids and cochlear implants, transform the lives of hearing-impaired people. However, users often struggle to locate and segregate sounds. This leads to impaired threat detection and an inability to understand speech in noisy environments. Recent evidence suggests ...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2021.1863782
更新日期:2020-12-29 00:00:00
abstract:INTRODUCTION:Refinements in endovascular technology have revolutionized the treatment of intracranial aneurysms (IAs) with the development of flow-diversion technology. The first generation of the Pipelin Embolization Device (PED) has demonstrated its safety and efficacy. However, the deployment technique was a difficu...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2016.1231573
更新日期:2016-10-01 00:00:00
abstract::Vitreoretinal surgery has recently undergone remarkable developments. The introduction of micro-incision vitrectomy surgery using 25- and 23-gauge techniques has led to minimally invasive, faster, safer, and more accurate surgeries. Similarly, intraocular illumination and observation systems have advanced from light p...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2014.882226
更新日期:2014-03-01 00:00:00
abstract:INTRODUCTION:Approximately one-third of all ischemic strokes and the ensuing health and economic burden can be attributed to the presence of atrial fibrillation (AF). The global prevalence of AF continues to rise, thus making it by far the most common diagnosed cardiac arrhythmia. Percutaneous left atrial appendage (LA...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2020.1837621
更新日期:2020-11-01 00:00:00
abstract::To obtain data for maternal stroke volume and cardiac output during pregnancy, it is preferable to use a non-invasive, accurate and reproducible method. In this aspect, impedance cardiography is an excellent technique which is also highly accessible and easy to perform. This paper is a comprehensive review on the publ...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2013.853466
更新日期:2013-11-01 00:00:00
abstract::Mechanical circulatory support devices are the mainstay of treatment for severe cardiogenic shock refractory to pharmacologic therapy. Their evolution over the past few decades has been remarkable with a common theme of developing reliable, less bulky and more easily percutaneously implantable devices. The goal of thi...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2015.1086265
更新日期:2015-01-01 00:00:00
abstract::The advent of catheter ablation has revolutionized the treatment of supraventricular cardiac arrhythmias, including in the last few years, atrial fibrillation. The discovery of electrically active sleeves of atrial myocardium extending into the pulmonary veins has led to the development of pulmonary vein ostial ablati...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/erd.10.59
更新日期:2011-01-01 00:00:00
abstract::Background: Saline is not biocompatible with saphenous vein grafts and does not protect against ischemia reperfusion injury. We compared normal heparinized saline with DuraGraft, a new graft-storage solution, in in-vitro and ex-vivo assays to evaluate the effects on cells and vascular graft tissue.Methods: Human saphe...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2019.1682996
更新日期:2019-11-01 00:00:00
abstract::Insertable cardiac monitors (ICMs) are leadless subcutaneous devices that continuously monitor the heart rhythm and record events over a timeframe measured in years, allowing for the diagnosis of infrequent rhythm abnormalities that can be the cause of palpitations, syncope and stroke. To date, ICMs have primarily bee...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2014.953059
更新日期:2015-01-01 00:00:00