A clinical update on the mid-term clinical performance of the Ovation endograft.

Abstract:

INTRODUCTION:The Ovation stent-graft uncouples the steps of fixation and sealing via a pair of polymer-filled inflatable rings. Apart from the well-documented early results, newer data emerged for mid-term results of Ovation and are presented in this review. AREAS COVERED:Aim of this article was to report all current studies with the mid-term results of the particular endograft, the incidence of complications and failure, and discuss their management. EXPERT COMMENTARY:The Ovation stent-graft exhibits very satisfactory clinical mid-term results in abdominal aortic aneurysms treated within the instructions-for-use. It can also have a very promising role in challenging neck anatomies with conical shape and presence of thrombus or calcification. However, this should be not considered a panacea and long-term results are needed to validate this intriguing aspect.

journal_name

Expert Rev Med Devices

authors

Koutsoumpelis A,Georgakarakos E,Tasopoulou KM,Kontopodis N,Argyriou C,Georgiadis GS

doi

10.1080/17434440.2019.1555467

subject

Has Abstract

pub_date

2019-01-01 00:00:00

pages

57-62

issue

1

eissn

1743-4440

issn

1745-2422

journal_volume

16

pub_type

杂志文章,评审
  • Ventricular assist devices for the failing univentricular circulation.

    abstract:INTRODUCTION:Improved survival following single ventricle palliation has led to a large population of patients with a univentricular circulation, many of whom develop heart failure. Increasing experience with ventricular assist devices (VAD) in children has paved the way for VAD support in those with failing univentric...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2017.1332523

    authors: Buratto E,Shi WY,Ye XT,Konstantinov IE

    更新日期:2017-06-01 00:00:00

  • Crux vena cava filter.

    abstract::Inferior vena cava filters are widely accepted for pulmonary embolic prophylaxis in high-risk patients with contraindications to anticoagulation. While long-term complications have been associated with permanent filters, retrievable filters are now available and have resulted in the rapid expansion of this technology....

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/erd.09.25

    authors: Murphy EH,Johnson ED,Kopchok GE,Fogarty TJ,Arko FR

    更新日期:2009-09-01 00:00:00

  • Robotics in invasive cardiac electrophysiology.

    abstract::Robotic systems allow for mapping and ablation of different arrhythmia substrates replacing hand maneuvering of intracardiac catheters with machine steering. Currently there are four commercially available robotic systems. Niobe magnetic navigation system (Stereotaxis Inc., St Louis, MO) and Sensei robotic navigation ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.916207

    authors: Shurrab M,Schilling R,Gang E,Khan EM,Crystal E

    更新日期:2014-07-01 00:00:00

  • Cochlear implants: current status and future potential.

    abstract::This article reviews the current status of cochlear implantation in both adults and children, including expanding candidacy groups, bilateral implantation, advances in speech processing software, internal and external device hardware, surgical techniques and outcomes. Promising advances, novel therapies and evolving c...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.12

    authors: Cosetti MK,Waltzman SB

    更新日期:2011-05-01 00:00:00

  • Treating bladder-outflow obstruction with thermo-expandable prostate metal stents.

    abstract::Bladder-outflow obstruction is a common age-related clinical entity due to a variety of benign and malignant diseases of the prostate. Surgical treatment is not suitable for high-risk elderly patients who seek minimally invasive management. We present a prostatic thermo-expandable metal stent for treating bladder-outf...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.13

    authors: Papatsoris AG,El-Husseiny T,Sawada Y,Takahashi T,Nagaoka A,Maan Z,Moraitis K,Masood J,Junaid I,Buchholz N

    更新日期:2009-07-01 00:00:00

  • Use of Amplatzer occluders for treatment of aorto-pulmonary fistulas - case and review of the literature.

    abstract:INTRODUCTION:the use of amplatzer occluder family in daily clinical practice has already overcome on-label indications, with growing clinical experience and the technological evolution of devices. Areas covered: We present the case of a patient with a very rare complication following proximal aortic surgery treated usi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1389636

    authors: Toušek P,Kočka V,Petr R,Ulman J,Hlavička J,Kolesár M

    更新日期:2017-11-01 00:00:00

  • Computer-aided design and manufacturing of surgical templates and their clinical applications: a review.

    abstract:INTRODUCTION:The surgical template is a guide aimed at directing the implant placement, tumor resection, osteotomy and bone repositioning. Using it, preoperative planning can be transferred to the actual surgical site, and the precision, safety and reliability of the surgery can be improved. However, the actual workflo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1218758

    authors: Chen X,Xu L,Wang W,Li X,Sun Y,Politis C

    更新日期:2016-09-01 00:00:00

  • Cardima Surgical Ablation System: a novel tool for cardiac ablation in the treatment of atrial fibrillation.

    abstract::Atrial fibrillation is a pervasive and difficult heart rhythm problem for more than 3 million Americans. Patients are plagued by myriad symptoms and are exposed to the risk of stroke. Attempts to restore normal rhythm with drug therapy have been largely unsuccessful and the complications associated with long-term anti...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.9

    authors: Saltman AE

    更新日期:2009-05-01 00:00:00

  • High flow nasal cannula in the emergency department: indications, safety  and effectiveness.

    abstract:INTRODUCTION:Heated humidified high flow nasal cannula therapy (HHHFNCT) is emerging as a popular non-invasive mode of respiratory support in adults and children. In recent years, its use has extended beyond the intensive care unit to other clinical areas. This review aims to explore the mechanism of action, indication...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1548276

    authors: Wang J,Lee KP,Chong SL,Loi M,Lee JH

    更新日期:2018-12-01 00:00:00

  • Electrosurgical devices: are we closer to finding the ideal appliance? A critical review of current evidence for the use of electrosurgical devices in general surgery.

    abstract::Over the last decade, the use of electrosurgical devices has become commonplace across all surgical specialities. The current market is large enough to warrant a comparative review of each device. This has even more impetus given the budgetary constraints of NHS organisations. This review aims to compare the benefits ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.2016.1134312

    authors: Sran H,Sebastian J,Hossain MA

    更新日期:2016-01-01 00:00:00

  • Percutaneous laser ablation of cervical metastatic lymph nodes in papillary thyroid carcinoma: clinical efficacy and anatomical considerations.

    abstract::Background: Papillary thyroid carcinoma is the most common type of thyroid cancer; despite its generally indolent course, patients often develop local post-operative recurrences. Re-operation, however, holds a high complication rate, while at the same time, not all patients benefit from radioiodine ablation. This syst...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2021.1864323

    authors: Spartalis E,Karagiannis SP,Plakopitis N,Theodori MA,Athanasiadis DI,Schizas D,Spartalis M,Troupis T

    更新日期:2020-12-29 00:00:00

  • Autofluorescence imaging videobronchoscopy in the detection of lung cancer: from research tool to everyday procedure.

    abstract::Autofluorescence imaging videobronchoscopy (AFI) is one of the new systems of autofluorescence bronchoscopy designed for thorough examination of bronchial mucosa. The integration of autofluorescence and videobronchoscopy provides clear images of normal and pathologically altered bronchial mucosa. Major indications for...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/erd.10.92

    authors: Zaric B,Perin B,Becker HD,Herth FF,Eberhardt R,Djuric M,Djuric D,Matijasevic J,Kopitovic I,Stanic J

    更新日期:2011-03-01 00:00:00

  • Robot-assisted total hip arthroplasty.

    abstract::Precise and accurate biomechanical reconstruction during total hip arthroplasty (THA) is essential for durable long-term survivorship. Accurate fit of cementless hip implants is also crucial to reduce micromotion between the bone-implant interfaces to allow for stable osseointegration. Robotic technology aims to minim...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1124018

    authors: Banerjee S,Cherian JJ,Elmallah RK,Pierce TP,Jauregui JJ,Mont MA

    更新日期:2016-01-01 00:00:00

  • Thermal scalpel to target cancer.

    abstract::Nanotechnology is increasingly applied to the field of medicine, particularly for the treatment of cancer. In this regard, gold nanoparticles can mediate hyperthermia induction and kill tumor cells upon laser irradiation, thereby functioning as a 'thermal scalpel'. Recent developments in gold nanoparticle design have ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.2.131

    authors: Everts M

    更新日期:2007-03-01 00:00:00

  • Development of inexpensive blood imaging systems: where are we now?

    abstract::Clinical applications in the developing world, such as malaria and anemia diagnosis, demand a change in the medical paradigm of expensive care given in central locations by highly trained professionals. There has been a recent explosion in optical technologies entering the consumer market through the widespread adopti...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1075388

    authors: Chu K,Smith ZJ,Wachsmann-Hogiu S

    更新日期:2015-01-01 00:00:00

  • Current interventional coronary applications of excimer laser.

    abstract::Excimer laser utilization as an adjunctive device for percutaneous coronary intervention has increased in the last few years. Many technical advancements have led to better results in terms of efficacy and safety with a low complication rate. In particular, excimer laser for thrombus-containing lesions is able to achi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.811846

    authors: Fracassi F,Roberto M,Niccoli G

    更新日期:2013-07-01 00:00:00

  • Mechanical adjuncts for cardiocerebral resuscitation.

    abstract::Introduction: Cardiac arrest remains a worldwide health problem with very poor outcome. In the absence of bystander resuscitation, survival rates decrease by 10% per minute of arrest and global ischemia. Even the best manual chest compressions, however, can only produce a fraction of normal cardiac output and blood fl...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1649135

    authors: Riess ML,Balzer C

    更新日期:2019-09-01 00:00:00

  • In vivo nucleic acid delivery with PEI and its derivatives: current status and perspectives.

    abstract::Poly(ethylenimine) (PEI) has recently emerged as a favorable candidate for nucleic acid (NA) delivery because of its good effectivity at low cost. Despite copious derivatives and formulations being explored over the years, there is a scarcity of efforts to systematically review the current status and unmet needs of re...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.83

    authors: Lai WF

    更新日期:2011-03-01 00:00:00

  • Hemodialysis machine technology: a global overview.

    abstract::The market for hemodialysis machines, the background, the current products of manufacturers and the features of hemodialysis machines are described in this article. In addition to the established companies and their products, Chinese manufacturers, and new developments for home hemodialysis, are outlined based on publ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.54

    authors: Polaschegg HD

    更新日期:2010-11-01 00:00:00

  • From portable dialysis to a bioengineered kidney.

    abstract:INTRODUCTION:Since the advent of peritoneal dialysis (PD) in the 1970s, the principles of dialysis have changed little. In the coming decades, several major breakthroughs are expected. AREAS COVERED:Novel wearable and portable dialysis devices for both hemodialysis (HD) and PD are expected first. The HD devices could ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1462697

    authors: van Gelder MK,Mihaila SM,Jansen J,Wester M,Verhaar MC,Joles JA,Stamatialis D,Masereeuw R,Gerritsen KGF

    更新日期:2018-05-01 00:00:00

  • Bacteriophage biosensors for antibiotic-resistant bacteria.

    abstract::An increasing number of disease-causing bacteria are resistant to one or more anti-bacterial drugs utilized for therapy. Early and speedy detection of these pathogens is therefore very important. Traditional pathogen detection techniques, that include microbiological and biochemical assays are long and labor-intensive...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.882767

    authors: Sorokulova I,Olsen E,Vodyanoy V

    更新日期:2014-03-01 00:00:00

  • Safe incorporation of new technologies in thyroid surgery.

    abstract::The history of thyroid surgery starts with Billroth, Kocher and Halsted, who developed the technique for thyroidectomy between the years of 1873 and 1910. In general the essential objectives for thyroidectomy are: sparing the parathyroid glands, avoidance of injury to the laryngeal nerves, an accurate hemostasis and a...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.6.747

    authors: Dionigi G,Bacuzzi A,Bertocchi V,Carrafiello G,Boni L,Rovera F,Dionigi R

    更新日期:2008-11-01 00:00:00

  • Current and future developments in artificial muscles using electroactive polymers.

    abstract::For decades, electroactive polymers received relatively little attention due to their limited actuation capability. However, in the last 15 years, a series of electroactive polymer materials have emerged that produce a significant shape or size change in response to electrical stimulation. These materials have the clo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.6.731

    authors: Bar-Cohen Y

    更新日期:2005-11-01 00:00:00

  • Clinical role of fluorescence imaging in colorectal surgery - a review.

    abstract:INTRODUCTION:Anastomotic leak (AL) after colorectal surgery is a devastating complication; decreased blood perfusion is an important risk factor. Surgeons rely on subjective measures to assess bowel perfusion. Fluorescence imaging (FI) with indocyanine green (ICG) provides a real-time objective assessment of intestinal...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,meta分析,评审

    doi:10.1080/17434440.2017.1265444

    authors: Mizrahi I,Wexner SD

    更新日期:2017-01-01 00:00:00

  • Evolution of endovascular stroke therapies and devices.

    abstract::Acute ischemic stroke is caused by occlusion of a cerebral artery, resulting in loss of brain tissue and neurologic deficits. However, a portion of the ischemic brain can be salvaged if blood flow is restored within an appropriate time frame. The past year has seen the publication of five positive randomized controlle...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143772

    authors: Wallace AN,Kansagra AP,McEachern J,Moran CJ,Cross DT 3rd,Derdeyn CP

    更新日期:2016-01-01 00:00:00

  • Resurrection of hip resurfacing: what is the evidence?

    abstract::Total hip resurfacing has long been conceptually attractive to both surgeons and patients. However, historically it has been plagued by limited durability and marked acetabular bone loss. The recent development of wear-resistant bearings, such as metal-on-metal, has led to renewed interest in hip resurfacing in the or...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.6.755

    authors: Moroni A,Cadossi M,Bellenghi C,Romagnoli M,Bevoni R,Giannini S

    更新日期:2006-11-01 00:00:00

  • Cutting balloons, covered stents and paclitaxel-coated balloons for the treatment of dysfunctional dialysis access.

    abstract:INTRODUCTION:Percutaneous transcatheter balloon angioplasty has evolved to the current mainstay treatment for salvage of dysfunctional dialysis access. Nonetheless, it is frequently associated with recurrent vessel restenosis and the need for multiple repeat treatments in order to maintain hemodynamic patency. Cutting-...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1254548

    authors: Kitrou P,Spiliopoulos S,Karnabatidis D,Katsanos K

    更新日期:2016-12-01 00:00:00

  • Non-invasive imaging techniques to assess myocardial perfusion.

    abstract:INTRODUCTION:Coronary artery disease affecting myocardial perfusion continues to be the leading cause of cardiovascular morbidity and mortality worldwide. While invasive evaluation based on coronary angiography and flow measurements still is considered the reference technique for assessing myocardial perfusion, technol...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1834844

    authors: Villemain O,Baranger J,Jalal Z,Lam C,Calais J,Pernot M,Cifra B,Friedberg MK,Mertens L

    更新日期:2020-11-01 00:00:00

  • Does the novel delivery system for the STENTYS self-apposing coronary stent increase the risk of stent edge dissections? Optical coherence tomography post stent findings.

    abstract:BACKGROUND:With optical coherence tomography (OCT), details of arterial injuries during percutaneous coronary intervention can be assessed accurately. There might be an increased risk of stent edge dissections with the novel delivery system for the STENTYS stent. We evaluated the prevalence of stent edge dissections us...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1421942

    authors: Lu H,Kalkman DN,Grundeken MJ,Tijssen JGP,Wykrzykowska JJ,de Winter RJ,Koch KT

    更新日期:2018-02-01 00:00:00

  • The Reveal LINQ insertable cardiac monitor.

    abstract::Insertable cardiac monitors (ICMs) are leadless subcutaneous devices that continuously monitor the heart rhythm and record events over a timeframe measured in years, allowing for the diagnosis of infrequent rhythm abnormalities that can be the cause of palpitations, syncope and stroke. To date, ICMs have primarily bee...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.953059

    authors: Tomson TT,Passman R