Hemodialysis machine technology: a global overview.

Abstract:

:The market for hemodialysis machines, the background, the current products of manufacturers and the features of hemodialysis machines are described in this article. In addition to the established companies and their products, Chinese manufacturers, and new developments for home hemodialysis, are outlined based on publications available on the internet and patent applications. Here, a critical review of the state of the art questions the medical usefulness of high-tech developments, compared with the benefits of more frequent and/or longer dialysis treatment with comparable simple machines.

journal_name

Expert Rev Med Devices

authors

Polaschegg HD

doi

10.1586/erd.10.54

subject

Has Abstract

pub_date

2010-11-01 00:00:00

pages

793-810

issue

6

eissn

1743-4440

issn

1745-2422

journal_volume

7

pub_type

杂志文章,评审
  • Using medical imaging for the detection of adverse events ("incidents") during the utilization of left ventricular assist devices in adult patients with advanced heart failure.

    abstract::Ventricular assist devices (VAD) are used for mechanical support of the terminally failing heart. Failure of these life supporting systems can be fatal. Early and reliable detection of any upcoming problems is mandatory and is crucial for the outcome. Medical imaging methods are described within this review, which are...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1166051

    authors: Kaufmann F,Krabatsch T

    更新日期:2016-05-01 00:00:00

  • Does CircuLite Synergy assist device as partial ventricular support have a place in modern management of advanced heart failure?

    abstract::The discrepancy between the number of patients on the waiting list and available donor hearts has led to the successful development of left ventricular assist devices (LVAD) as a bridge to transplantation. The conventional LVADs are designed to provide full hemodynamic support for the end-stage failing heart. However,...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.985208

    authors: Mohite PN,Sabashnikov A,Simon AR,Weymann A,Patil NP,Unsoeld B,Bireta C,Popov AF

    更新日期:2015-01-01 00:00:00

  • Bacteriophage biosensors for antibiotic-resistant bacteria.

    abstract::An increasing number of disease-causing bacteria are resistant to one or more anti-bacterial drugs utilized for therapy. Early and speedy detection of these pathogens is therefore very important. Traditional pathogen detection techniques, that include microbiological and biochemical assays are long and labor-intensive...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.882767

    authors: Sorokulova I,Olsen E,Vodyanoy V

    更新日期:2014-03-01 00:00:00

  • Is there an optimal interventional device for the salvage of thrombosed native angioaccess for hemodialysis?

    abstract::The rescue of autogenous angioaccess for hemodialysis can be performed surgically or radiologically. For the latter, there is current debate as to whether a mechanical hydrodynamic device confers a clinical advantage over a rotational thrombectomy. The evaluated article describes a single center retrospective cohort s...

    journal_title:Expert review of medical devices

    pub_type: 评论,杂志文章

    doi:10.1586/erd.12.75

    authors: Hossain MA,Chung R,Frampton AE,Chemla ES

    更新日期:2013-01-01 00:00:00

  • Cochlear implants: current status and future potential.

    abstract::This article reviews the current status of cochlear implantation in both adults and children, including expanding candidacy groups, bilateral implantation, advances in speech processing software, internal and external device hardware, surgical techniques and outcomes. Promising advances, novel therapies and evolving c...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.12

    authors: Cosetti MK,Waltzman SB

    更新日期:2011-05-01 00:00:00

  • Robot-assisted total hip arthroplasty.

    abstract::Precise and accurate biomechanical reconstruction during total hip arthroplasty (THA) is essential for durable long-term survivorship. Accurate fit of cementless hip implants is also crucial to reduce micromotion between the bone-implant interfaces to allow for stable osseointegration. Robotic technology aims to minim...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1124018

    authors: Banerjee S,Cherian JJ,Elmallah RK,Pierce TP,Jauregui JJ,Mont MA

    更新日期:2016-01-01 00:00:00

  • Shields and garb for decreasing radiation exposure in the cath lab.

    abstract:INTRODUCTION:Decreasing radiation exposure of the cardiac catheterization laboratory staff is critical for minimizing radiation-related adverse outcomes and can be accomplished by decreasing patient dose and by shielding. Areas covered: protection from ionizing radiation can be achieved with architectural, equipment-mo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1510771

    authors: Karatasakis A,Brilakis ES

    更新日期:2018-09-01 00:00:00

  • Cardima Surgical Ablation System: a novel tool for cardiac ablation in the treatment of atrial fibrillation.

    abstract::Atrial fibrillation is a pervasive and difficult heart rhythm problem for more than 3 million Americans. Patients are plagued by myriad symptoms and are exposed to the risk of stroke. Attempts to restore normal rhythm with drug therapy have been largely unsuccessful and the complications associated with long-term anti...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.9

    authors: Saltman AE

    更新日期:2009-05-01 00:00:00

  • Developments in dosing aids and adherence devices for glaucoma therapy: current and future perspectives.

    abstract::Glaucoma is a leading cause of blindness worldwide. Currently, topical drops are the mainstay of treatment for patients who suffer from this chronic disease. Adherence to topical therapy is known to be affected by forgetfulness, frequent dosing requirements and physical limitations. Dosing and adherence aids are desig...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.2.261

    authors: Kahook MY

    更新日期:2007-03-01 00:00:00

  • Autofluorescence imaging videobronchoscopy in the detection of lung cancer: from research tool to everyday procedure.

    abstract::Autofluorescence imaging videobronchoscopy (AFI) is one of the new systems of autofluorescence bronchoscopy designed for thorough examination of bronchial mucosa. The integration of autofluorescence and videobronchoscopy provides clear images of normal and pathologically altered bronchial mucosa. Major indications for...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/erd.10.92

    authors: Zaric B,Perin B,Becker HD,Herth FF,Eberhardt R,Djuric M,Djuric D,Matijasevic J,Kopitovic I,Stanic J

    更新日期:2011-03-01 00:00:00

  • Sleep assessment devices: types, market analysis, and a critical view on accuracy and validation.

    abstract::Introduction: Sleep assessment devices are essential for the detection, diagnosis, and monitoring of sleep disorders. This paper provides a state-of-the-art review and comparison of sleep assessment devices and a market analysis.Areas covered: Hardware devices are classified into contact and contactless devices. For e...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1693890

    authors: Ibáñez V,Silva J,Navarro E,Cauli O

    更新日期:2019-12-01 00:00:00

  • Computer-aided design and manufacturing of surgical templates and their clinical applications: a review.

    abstract:INTRODUCTION:The surgical template is a guide aimed at directing the implant placement, tumor resection, osteotomy and bone repositioning. Using it, preoperative planning can be transferred to the actual surgical site, and the precision, safety and reliability of the surgery can be improved. However, the actual workflo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1218758

    authors: Chen X,Xu L,Wang W,Li X,Sun Y,Politis C

    更新日期:2016-09-01 00:00:00

  • Electrothermal bipolar vessel sealing system (LigaSure) for hemostasis during thyroid surgery: a comprehensive review.

    abstract::Conventional hemostatic technologies utilized in thyroid surgery include clamp-and-tie, clips and monopolar and bipolar diathermy. Over the last decade, there has been a major shift towards utilizing newer hemostatic technologies, most notably the electrothermal bipolar vessel sealing systems (EBVS) and the Harmonic S...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.13.6

    authors: Butskiy O,Wiseman SM

    更新日期:2013-05-01 00:00:00

  • Holmium:YAG laser system for transmyocardial revascularization.

    abstract::Transmyocardial revascularization, using the US FDA-approved holmium: yttrium-aluminum-garnet (Ho:YAG) laser system, is a surgical option for patients with debilitating angina caused by diffuse coronary artery disease in areas of the heart not amenable to complete revascularization using conventional treatments. Incre...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.3.2.137

    authors: Allen KB

    更新日期:2006-03-01 00:00:00

  • The Lean and Agile Multi-dimensional Process (LAMP) - a new framework for rapid and iterative evidence generation to support health-care technology design and development.

    abstract::Introduction: Health technology assessments (HTA) are tools for policymaking and resource allocation. Early HTAs are increasingly used in design and development of new technologies. Conducting early HTAs is challenging, due to a lack of evidence and significant uncertainties in the technology and the market. A multi-d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1743174

    authors: Ni M,Borsci S,Walne S,Mclister AP,Buckle P,Barlow JG,Hanna GB

    更新日期:2020-04-01 00:00:00

  • Modeling of the medical device development process.

    abstract::Models are abstract representations of reality that are built, analyzed and manipulated to augment the understanding of that reality. They can either be mental or codified but, in both cases, they contribute to good decision-making by ensuring that the right people use the right information at the right time. In order...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.36

    authors: Santos IC,Gazelle GS,Rocha LA,Tavares JM

    更新日期:2012-09-01 00:00:00

  • Currently available metacarpophalangeal prostheses: their designs and prospective considerations.

    abstract::Although implanted for over 40 years, finger prostheses have failed to match the success achieved by artificial hip and knee prostheses, despite a myriad of designs having been proposed and implanted. This article looks at the currently available designs of metacarpophalangeal prosthesis, both single-piece and multico...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.1.2.193

    authors: Joyce TJ

    更新日期:2004-11-01 00:00:00

  • Towards soft robotic devices for site-specific drug delivery.

    abstract::Considerable research efforts have recently been dedicated to the establishment of various drug delivery systems (DDS) that are mechanical/physical, chemical and biological/molecular DDS. In this paper, we report on the recent advances in site-specific drug delivery (site-specific, controlled, targeted or smart drug d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1091722

    authors: Alici G

    更新日期:2015-01-01 00:00:00

  • Could a new sensory pen assist in the early diagnosis of Parkinson's?

    abstract::Neurodegeneration in Parkinson's disease (PD) affects both the fine motor control of the fingers and gross movement of the upper limb. Handwriting examinations are commonly performed in the analysis of tremor in PD and there is validity in subjective assessment in the clinic. However, there is clinical need for a more...

    journal_title:Expert review of medical devices

    pub_type: 社论,评审

    doi:10.1586/17434440.2014.900437

    authors: Walker RW,Zietsma R,Gray WK

    更新日期:2014-05-01 00:00:00

  • COVID-19: ensuring our medical equipment can meet the challenge.

    abstract::To predict the spread of coronavirus disease globally and consequently prepare the hospital facilities with the required technology is a challenge. The availability of essential medical equipment to support patients affected by Covid-19 is globally limited. Areas covered This perspective gives a technical view of the ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1772757

    authors: Garzotto F,Ceresola E,Panagiotakopoulou S,Spina G,Menotto F,Benozzi M,Casarotto M,Lanera C,Bonavina MG,Gregori D,Meneghesso G,Opocher G

    更新日期:2020-06-01 00:00:00

  • Performance of a new device for the clinical determination of light discomfort.

    abstract:PURPOSE:To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS:A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was asse...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1837623

    authors: Montés-Micó R,Cerviño A,Martínez-Albert N,García-Marqués JV,Marie S

    更新日期:2020-11-01 00:00:00

  • A review of thermal methods and technologies for diabetic foot assessment.

    abstract::Temperature analysis has been considered as a complementary method in medical evaluation and diagnosis. Several studies demonstrated that monitoring the temperature variations of the feet of diabetic patients can be helpful in the early identification of diabetic foot manifestations, and also in changing behaviors, wh...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1032251

    authors: Sousa P,Felizardo V,Oliveira D,Couto R,Garcia NM

    更新日期:2015-07-01 00:00:00

  • Does the novel delivery system for the STENTYS self-apposing coronary stent increase the risk of stent edge dissections? Optical coherence tomography post stent findings.

    abstract:BACKGROUND:With optical coherence tomography (OCT), details of arterial injuries during percutaneous coronary intervention can be assessed accurately. There might be an increased risk of stent edge dissections with the novel delivery system for the STENTYS stent. We evaluated the prevalence of stent edge dissections us...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1421942

    authors: Lu H,Kalkman DN,Grundeken MJ,Tijssen JGP,Wykrzykowska JJ,de Winter RJ,Koch KT

    更新日期:2018-02-01 00:00:00

  • Evaluation of the WATCHMAN left atrial appendage closure device.

    abstract::Left atrial appendage device occlusion for the preventions of systemic thromboembolism and stroke represents a major breakthrough in the field of cardiovascular disease. The wide prevalence of atrial fibrillation with devastating consequences of thromboembolic stroke as a result of thrombus arising from the left atria...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.940315

    authors: Alli O,Holmes D Jr

    更新日期:2014-11-01 00:00:00

  • Current interventional coronary applications of excimer laser.

    abstract::Excimer laser utilization as an adjunctive device for percutaneous coronary intervention has increased in the last few years. Many technical advancements have led to better results in terms of efficacy and safety with a low complication rate. In particular, excimer laser for thrombus-containing lesions is able to achi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.811846

    authors: Fracassi F,Roberto M,Niccoli G

    更新日期:2013-07-01 00:00:00

  • Polyhydroxyalkanoate (PHA): applications in drug delivery and tissue engineering.

    abstract:INTRODUCTION:The applications of naturally obtained polymers are tremendously increased due to them being biocompatible, biodegradable, environmentally friendly and renewable in nature. Among them, polyhydroxyalkanoates are widely studied and they can be utilized in many areas of human life research such as drug delive...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615439

    authors: Elmowafy E,Abdal-Hay A,Skouras A,Tiboni M,Casettari L,Guarino V

    更新日期:2019-06-01 00:00:00

  • Ventricular assist devices for the failing univentricular circulation.

    abstract:INTRODUCTION:Improved survival following single ventricle palliation has led to a large population of patients with a univentricular circulation, many of whom develop heart failure. Increasing experience with ventricular assist devices (VAD) in children has paved the way for VAD support in those with failing univentric...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2017.1332523

    authors: Buratto E,Shi WY,Ye XT,Konstantinov IE

    更新日期:2017-06-01 00:00:00

  • Miniaturization of left ventricular assist devices: the ongoing trend.

    abstract::The shortage of appropriate donor hearts and the expanding pool of patients waiting for a heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. With expanding clinical experience and continued technical advances, continuous-flow pumps are evolving...

    journal_title:Expert review of medical devices

    pub_type: 历史文章,杂志文章,评审

    doi:10.1586/erd.11.62

    authors: Garbade J,Bittner HB,Lehmann S,Mohr FW,Barten MJ

    更新日期:2012-01-01 00:00:00

  • Insertable cardiac monitors: current indications and devices.

    abstract:INTRODUCTION:Recurrent unexplained syncope is a well-established indication for an insertable cardiac monitor (ICM). Recently, the indications for an ICM have been expanded. AREAS COVERED:This review article discusses the current indications for ICMs and gives an overview of the latest generation of commercially avail...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1557046

    authors: Sakhi R,Theuns DAMJ,Szili-Torok T,Yap SC

    更新日期:2019-01-01 00:00:00

  • Scientific evidence for the use of modern patellofemoral arthroplasty.

    abstract::Patellofemoral arthroplasty has been utilized as a treatment for isolated patellofemoral arthritis for more than 30 years. However, the use of this procedure remains controversial, as many surgeons prefer to use total knee arthroplasty, even for isolated patellofemoral arthritis. While historically, the results with t...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/erd.09.53

    authors: Gupta RR,Zywiel MG,Leadbetter WB,Bonutti P,Mont MA

    更新日期:2010-01-01 00:00:00