Computer-aided design and manufacturing of surgical templates and their clinical applications: a review.

Abstract:

INTRODUCTION:The surgical template is a guide aimed at directing the implant placement, tumor resection, osteotomy and bone repositioning. Using it, preoperative planning can be transferred to the actual surgical site, and the precision, safety and reliability of the surgery can be improved. However, the actual workflow of the surgical template design and manufacturing is quite complicated before the final clinical application. AREAS COVERED:The major goal of the paper is to provide a comprehensive reference source of the current and future development of the template design and manufacturing for relevant researchers. Expert commentary: This paper aims to present a review of the necessary procedures in the template-guided surgery including the image processing, 3D visualization, preoperative planning, surgical guide design and manufacturing. In addition, the template-guided clinical applications for various kinds of surgeries are reviewed, and it demonstrated that the precision of the surgery has been improved compared with the non-guided operations.

journal_name

Expert Rev Med Devices

authors

Chen X,Xu L,Wang W,Li X,Sun Y,Politis C

doi

10.1080/17434440.2016.1218758

subject

Has Abstract

pub_date

2016-09-01 00:00:00

pages

853-64

issue

9

eissn

1743-4440

issn

1745-2422

journal_volume

13

pub_type

杂志文章,评审
  • Using medical imaging for the detection of adverse events ("incidents") during the utilization of left ventricular assist devices in adult patients with advanced heart failure.

    abstract::Ventricular assist devices (VAD) are used for mechanical support of the terminally failing heart. Failure of these life supporting systems can be fatal. Early and reliable detection of any upcoming problems is mandatory and is crucial for the outcome. Medical imaging methods are described within this review, which are...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1166051

    authors: Kaufmann F,Krabatsch T

    更新日期:2016-05-01 00:00:00

  • Wearable sensors to improve detection of patient deterioration.

    abstract:INTRODUCTION:Monitoring a patient's vital signs forms a basic component of care, enabling the identification of deteriorating patients and increasing the likelihood of improving patient outcomes. Several paper-based track and trigger warning scores have been developed to allow clinical evaluation of a patient and guida...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1563480

    authors: Joshi M,Ashrafian H,Aufegger L,Khan S,Arora S,Cooke G,Darzi A

    更新日期:2019-02-01 00:00:00

  • Non-invasive imaging techniques to assess myocardial perfusion.

    abstract:INTRODUCTION:Coronary artery disease affecting myocardial perfusion continues to be the leading cause of cardiovascular morbidity and mortality worldwide. While invasive evaluation based on coronary angiography and flow measurements still is considered the reference technique for assessing myocardial perfusion, technol...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1834844

    authors: Villemain O,Baranger J,Jalal Z,Lam C,Calais J,Pernot M,Cifra B,Friedberg MK,Mertens L

    更新日期:2020-11-01 00:00:00

  • Laparoscopic cholecystectomy: device-related errors revealed through a national database.

    abstract::Laparoscopic techniques represent a key milestone in the development of modern surgery, offering a step change in quality of care, patient satisfaction and efficiency in use of health service resources. Laparoscopy is most widely used for gall bladder surgery. As would be expected with the introduction of any new tech...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.43

    authors: Panesar SS,Salvilla SA,Patel B,Donaldson SL

    更新日期:2011-09-01 00:00:00

  • Differential effects of public and private funding in the medical device industry.

    abstract:INTRODUCTION:Funding for scientific advancement comes from two dominant sources: public funds used to generate knowledge, and private sector funds in the pursuit of commercial products. It is unclear how to compare the outputs of these two financial mechanisms because both sectors are motivated by common goods but are ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1419866

    authors: Kang HD,Edelman ER,Ku DN

    更新日期:2018-02-01 00:00:00

  • Mechanical circulatory support devices: methods to optimize hemodynamics during use.

    abstract:INTRODUCTION:Mechanical circulatory support (MCS) is an increasingly utilized mode of therapy in the management of advanced heart failure, both as bridge to heart transplantation and destination therapy. As MCS becomes more prevalent, it is ever more important to understand the complex hemodynamics of these devices, as...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1324292

    authors: Chung BB,Sayer G,Uriel N

    更新日期:2017-05-01 00:00:00

  • Perioperative monitoring of fluid responsiveness after esophageal surgery using stroke volume variation.

    abstract:OBJECTIVE:To assess the utility of a new arterial pressure-based cardiac output (FloTrac) and central venous oximetry (PreSep) monitoring system in the perioperative management of patients undergoing radical esophagectomy. CASE SERIES:From May 2006, a new analyzing device (Vigileo monitor; Edwards Lifesciences LLC, To...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.5.3.311

    authors: Kobayashi M,Ko M,Kimura T,Meguro E,Hayakawa Y,Irinoda T,Takagane A

    更新日期:2008-05-01 00:00:00

  • Transforaminal percutaneous endoscopic lumbar discectomy: technical tips to prevent complications.

    abstract::Transforaminal percutaneous endoscopic lumbar discectomy is regarded as an effective alternative to open discectomy. Remarkable technical evolution now enables selective endoscopic removal of an epidurally extruded disc fragment. As a result, the surgical indications for this technique are becoming broader. However, a...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.23

    authors: Ahn Y

    更新日期:2012-07-01 00:00:00

  • Biomolecular modification of implant surfaces.

    abstract::In this review, surface modification of implant devices by immobilization of biological molecules is discussed. A brief introduction to the development of biomolecular surface science is presented, followed by a review of current activities in selected fields. Bone-contacting devices and some cardiovascular implant de...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.3.361

    authors: Morra M

    更新日期:2007-05-01 00:00:00

  • The RNS System: responsive cortical stimulation for the treatment of refractory partial epilepsy.

    abstract::The RNS(®) System is the first commercially available device to provide closed-loop responsive brain stimulation. The system includes a cranially implanted neurostimulator that continually monitors the electrocorticogram through one or two depth and/or subdural cortical strip leads that are placed at the seizure focus...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.947274

    authors: Sun FT,Morrell MJ

    更新日期:2014-11-01 00:00:00

  • Scaffolds for liver tissue engineering.

    abstract::This review focuses on the expanding role for biomaterials and polymer scaffolds in liver tissue engineering. Studies are subdivided into in vitro and in vivo approaches. The in vitro section of the review discusses the challenges specific to liver tissue engineering, and how the choice of scaffold and its structure i...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.1.21

    authors: Hammond JS,Beckingham IJ,Shakesheff KM

    更新日期:2006-01-01 00:00:00

  • Current interventional coronary applications of excimer laser.

    abstract::Excimer laser utilization as an adjunctive device for percutaneous coronary intervention has increased in the last few years. Many technical advancements have led to better results in terms of efficacy and safety with a low complication rate. In particular, excimer laser for thrombus-containing lesions is able to achi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.811846

    authors: Fracassi F,Roberto M,Niccoli G

    更新日期:2013-07-01 00:00:00

  • Continuous-flow left ventricular assist device implantation in patients with preexisting mechanical mitral valves: a systematic review.

    abstract::Introduction: A preexisting mechanical mitral valve (MMV) is thought to be a thrombogenic risk factor after continuous-flow left ventricular assist device (CF-LVAD) implantation. We sought to evaluate the management and outcomes of preexisting MMVs in patients following CF-LVAD implantation.Areas covered: An electroni...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1754190

    authors: Gordon JS,O'Malley TJ,Maynes EJ,Wood CT,Kalantri N,Morris RJ,Samuels LE,Massey HT,Tchantchaleishvili V

    更新日期:2020-05-01 00:00:00

  • Creating a wearable artificial kidney: where are we now?

    abstract::A wearable and, ultimately, an implantable artificial kidney is a long-held aim in the treatment of patients with end-stage renal disease, provided that it would combine continuous blood purification, preventing the fluctuations in the internal environment associated with hemodialysis, while maintaining a high efficie...

    journal_title:Expert review of medical devices

    pub_type: 社论

    doi:10.1586/17434440.2015.1053466

    authors: Kooman JP,Joles JA,Gerritsen KG

    更新日期:2015-07-01 00:00:00

  • Bicomponent electrospun scaffolds to design extracellular matrix tissue analogs.

    abstract::In the last decade, bicomponent fibers have been proposed to fabricate bio-inspired systems for tissue repair, regenerative medicine, medical healthcare and clinical applications. In comparison with monocomponent fibers, key advantage concerns their ability of self-adapting to the physiological conditions through an e...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1126505

    authors: Guarino V,Cirillo V,Ambrosio L

    更新日期:2016-01-01 00:00:00

  • Right heart transcatheter valve therapies - a review of prostheses for the pulmonary and tricuspid positions.

    abstract::Minimally invasive, catheter-based treatment of valvular dysfunction has become an integral part of clinical routine. As left heart valvular disease is much more common and thus commercially of interest, transcatheter solutions for the treatment of aortic and mitral valvular defects were the first to become broadly cl...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.985654

    authors: Kuetting M,Pott D,Sedaghat A,Ng YA,Egron S,Rosefort C,Werner N,Sachweh J,Steinseifer U

    更新日期:2015-03-01 00:00:00

  • Wearable inertial sensors for human movement analysis.

    abstract:INTRODUCTION:The present review aims to provide an overview of the most common uses of wearable inertial sensors in the field of clinical human movement analysis. AREAS COVERED:Six main areas of application are analysed: gait analysis, stabilometry, instrumented clinical tests, upper body mobility assessment, daily-li...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1198694

    authors: Iosa M,Picerno P,Paolucci S,Morone G

    更新日期:2016-07-01 00:00:00

  • Anti-infective therapy with an Er:YAG laser: influence on peri-implant healing.

    abstract::In addition to conventional treatment modalities (mechanical and chemical), the use of lasers has been increasingly proposed for the treatment of periodontal and peri-implant infections (i.e., cleaning and detoxification of implant surfaces). Preliminary results from basic studies have pointed to the high potential of...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.3.267

    authors: Sculean A,Schwarz F,Becker J

    更新日期:2005-05-01 00:00:00

  • Could a new sensory pen assist in the early diagnosis of Parkinson's?

    abstract::Neurodegeneration in Parkinson's disease (PD) affects both the fine motor control of the fingers and gross movement of the upper limb. Handwriting examinations are commonly performed in the analysis of tremor in PD and there is validity in subjective assessment in the clinic. However, there is clinical need for a more...

    journal_title:Expert review of medical devices

    pub_type: 社论,评审

    doi:10.1586/17434440.2014.900437

    authors: Walker RW,Zietsma R,Gray WK

    更新日期:2014-05-01 00:00:00

  • Amplatzer Duct Occluder device: a new technology for the closure of the moderate-to-large-sized patent ductus arteriosus.

    abstract::The Amplatzer Duct Occluder is a novel device designed to allow for the transcatheter closure of virtually all sized patent ductus arteriosuses. Prior technologies have been cumbersome and challenging to deploy with somewhat less than ideal closure rates associated with their use. This article summarizes the present k...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.3.3.291

    authors: Pass RH

    更新日期:2006-05-01 00:00:00

  • Does CircuLite Synergy assist device as partial ventricular support have a place in modern management of advanced heart failure?

    abstract::The discrepancy between the number of patients on the waiting list and available donor hearts has led to the successful development of left ventricular assist devices (LVAD) as a bridge to transplantation. The conventional LVADs are designed to provide full hemodynamic support for the end-stage failing heart. However,...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.985208

    authors: Mohite PN,Sabashnikov A,Simon AR,Weymann A,Patil NP,Unsoeld B,Bireta C,Popov AF

    更新日期:2015-01-01 00:00:00

  • Robotics in invasive cardiac electrophysiology.

    abstract::Robotic systems allow for mapping and ablation of different arrhythmia substrates replacing hand maneuvering of intracardiac catheters with machine steering. Currently there are four commercially available robotic systems. Niobe magnetic navigation system (Stereotaxis Inc., St Louis, MO) and Sensei robotic navigation ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.916207

    authors: Shurrab M,Schilling R,Gang E,Khan EM,Crystal E

    更新日期:2014-07-01 00:00:00

  • Improving retrieval rates for retrievable inferior vena cava filters.

    abstract::The introduction of retrievable inferior vena cava (IVC) filters was an important step in the evolution of deep vein thrombosis/pulmonary embolism management. Their removability makes them preferred to permanent filters in many cases. IVC filter retrieval often occurs at a suboptimal rate, leading to complications ass...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.65

    authors: Dixon A,Stavropoulos SW

    更新日期:2013-01-01 00:00:00

  • Shortening hospital stay for thyroid surgery.

    abstract::The number of outpatient surgical procedures performed in hospitals, increases daily. In some countries, such as Italy, outpatient operations outnumber inpatient operations. The incidence of thyroid disorders and, in particular, the cancer forms, has been increasing sharply for many years in several countries. Even if...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.1.85

    authors: Dionigi G,Bacuzzi A,Rovera F,Boni L,Piantanida E,Tanda ML,Castano P,Annoni M,Bartalena L,Dionigi R

    更新日期:2008-01-01 00:00:00

  • Bacteriophage biosensors for antibiotic-resistant bacteria.

    abstract::An increasing number of disease-causing bacteria are resistant to one or more anti-bacterial drugs utilized for therapy. Early and speedy detection of these pathogens is therefore very important. Traditional pathogen detection techniques, that include microbiological and biochemical assays are long and labor-intensive...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.882767

    authors: Sorokulova I,Olsen E,Vodyanoy V

    更新日期:2014-03-01 00:00:00

  • Diagnosis of small-bowel diseases in the era of capsule endoscopy.

    abstract::Capsule endoscopy is a major breakthrough in gastrointestinal endoscopy and is a first-line tool to detect abnormalities of the small bowel, in up to 50% of patients, intestinal disorders are not associated with any physical findings or positive tests. Indications, yield and impact on patient management of this method...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.5.587

    authors: Pennazio M

    更新日期:2005-09-01 00:00:00

  • The Reveal LINQ insertable cardiac monitor.

    abstract::Insertable cardiac monitors (ICMs) are leadless subcutaneous devices that continuously monitor the heart rhythm and record events over a timeframe measured in years, allowing for the diagnosis of infrequent rhythm abnormalities that can be the cause of palpitations, syncope and stroke. To date, ICMs have primarily bee...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.953059

    authors: Tomson TT,Passman R

    更新日期:2015-01-01 00:00:00

  • From drug eluting stents to bioresorbable scaffolds; to new horizons in PCI.

    abstract::Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir technology planting the ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143356

    authors: Tenekecioglu E,Bourantas C,Abdelghani M,Zeng Y,Silva RC,Tateishi H,Sotomi Y,Onuma Y,Yılmaz M,Serruys PW

    更新日期:2016-01-01 00:00:00

  • Current and future developments in artificial muscles using electroactive polymers.

    abstract::For decades, electroactive polymers received relatively little attention due to their limited actuation capability. However, in the last 15 years, a series of electroactive polymer materials have emerged that produce a significant shape or size change in response to electrical stimulation. These materials have the clo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.6.731

    authors: Bar-Cohen Y

    更新日期:2005-11-01 00:00:00

  • Development of inexpensive blood imaging systems: where are we now?

    abstract::Clinical applications in the developing world, such as malaria and anemia diagnosis, demand a change in the medical paradigm of expensive care given in central locations by highly trained professionals. There has been a recent explosion in optical technologies entering the consumer market through the widespread adopti...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1075388

    authors: Chu K,Smith ZJ,Wachsmann-Hogiu S

    更新日期:2015-01-01 00:00:00