Bacteriophage biosensors for antibiotic-resistant bacteria.

Abstract:

:An increasing number of disease-causing bacteria are resistant to one or more anti-bacterial drugs utilized for therapy. Early and speedy detection of these pathogens is therefore very important. Traditional pathogen detection techniques, that include microbiological and biochemical assays are long and labor-intensive, while antibody or DNA-based methods require substantial sample preparation and purification. Biosensors based on bacteriophages have demonstrated remarkable potential to surmount these restrictions and to offer rapid, efficient and sensitive detection technique for antibiotic-resistant bacteria.

journal_name

Expert Rev Med Devices

authors

Sorokulova I,Olsen E,Vodyanoy V

doi

10.1586/17434440.2014.882767

subject

Has Abstract

pub_date

2014-03-01 00:00:00

pages

175-86

issue

2

eissn

1743-4440

issn

1745-2422

journal_volume

11

pub_type

杂志文章,评审
  • The EluNIRTM Ridaforolimus Eluting Coronary Stent System.

    abstract:INTRODUCTION:First-generation drug-eluting stents (DES) were developed and indeed proved their superiority compared to bare-metal stent in minimizing neo-intimal hyperplasia and in-stent restenosis (ISR), overall, reducing target vessel revascularization (TVR). Newer-generation DES are characterized by thinner struts, ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1549986

    authors: Savvoulidis P,Perlman G,Bagur R

    更新日期:2019-01-01 00:00:00

  • Stent placement for esophageal strictures: an update.

    abstract::The use of stents for esophageal strictures has evolved rapidly over the past 10 years, from rigid plastic tubes to flexible self-expanding metal (SEMS), plastic (SEPS) and biodegradable stents. For the palliative treatment of malignant dysphagia both SEMS and SEPS effectively provide a rapid relief of dysphagia. SEMS...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.44

    authors: Hirdes MM,Vleggaar FP,Siersema PD

    更新日期:2011-11-01 00:00:00

  • Digital breast tomosynthesis (3D-mammography) screening: data and implications for population screening.

    abstract::The evidence on digital breast tomosynthesis (DBT), or quasi-3D-mammography, for population breast screening has emerged rapidly: two prospective and several retrospective studies provide convincing evidence that mammography with DBT improves screening detection measures compared with standard mammography. Based on po...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1028362

    authors: Houssami N

    更新日期:2015-07-01 00:00:00

  • The Visible Heart® project and methodologies: novel use for studying cardiac monophasic action potentials and evaluating their underlying mechanisms.

    abstract:INTRODUCTION:This review describes the utilization of Visible Heart® methodologies for electrophysiologic studies, specifically in the investigation of monophasic action potential (MAP) recordings, with the aim to facilitate new catheter/device design and development that may lead to earlier diagnosis, treatment, and u...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1493922

    authors: Schmidt MM,Iaizzo PA

    更新日期:2018-07-01 00:00:00

  • Abdominal wall reconstruction using biological tissue grafts: present status and future opportunities.

    abstract::Surgeons often encounter the challenge of treating acquired abdominal wall defects following abdominal surgery. The current standard of practice is to repair most defects using permanent synthetic mesh material. Mesh augments the strength of the weakened abdominal wall fascia and enables the hernia repair to be perfor...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.5.657

    authors: Bellows CF,Alder A,Helton WS

    更新日期:2006-09-01 00:00:00

  • Improving retrieval rates for retrievable inferior vena cava filters.

    abstract::The introduction of retrievable inferior vena cava (IVC) filters was an important step in the evolution of deep vein thrombosis/pulmonary embolism management. Their removability makes them preferred to permanent filters in many cases. IVC filter retrieval often occurs at a suboptimal rate, leading to complications ass...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.65

    authors: Dixon A,Stavropoulos SW

    更新日期:2013-01-01 00:00:00

  • Non-invasive imaging techniques to assess myocardial perfusion.

    abstract:INTRODUCTION:Coronary artery disease affecting myocardial perfusion continues to be the leading cause of cardiovascular morbidity and mortality worldwide. While invasive evaluation based on coronary angiography and flow measurements still is considered the reference technique for assessing myocardial perfusion, technol...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1834844

    authors: Villemain O,Baranger J,Jalal Z,Lam C,Calais J,Pernot M,Cifra B,Friedberg MK,Mertens L

    更新日期:2020-11-01 00:00:00

  • Continuous-flow left ventricular assist device implantation in patients with preexisting mechanical mitral valves: a systematic review.

    abstract::Introduction: A preexisting mechanical mitral valve (MMV) is thought to be a thrombogenic risk factor after continuous-flow left ventricular assist device (CF-LVAD) implantation. We sought to evaluate the management and outcomes of preexisting MMVs in patients following CF-LVAD implantation.Areas covered: An electroni...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1754190

    authors: Gordon JS,O'Malley TJ,Maynes EJ,Wood CT,Kalantri N,Morris RJ,Samuels LE,Massey HT,Tchantchaleishvili V

    更新日期:2020-05-01 00:00:00

  • From drug eluting stents to bioresorbable scaffolds; to new horizons in PCI.

    abstract::Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir technology planting the ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143356

    authors: Tenekecioglu E,Bourantas C,Abdelghani M,Zeng Y,Silva RC,Tateishi H,Sotomi Y,Onuma Y,Yılmaz M,Serruys PW

    更新日期:2016-01-01 00:00:00

  • The role of active middle-ear implants in the rehabilitation of hearing loss.

    abstract::The surgical implantation of auditory devices to improve or restore the sensation of hearing in affected individuals is a rapidly growing area of modern ear, nose and throat, and audiological practice. Following the enormous success of cochlear implantation and set to take an increasing role in the rehabilitation of d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.18

    authors: Green K

    更新日期:2011-07-01 00:00:00

  • Strategies for replacing non-invasive brain stimulation sessions: recommendations for designing neurostimulation clinical trials.

    abstract:INTRODUCTION:Despite the potential impact of missed visits on the outcomes of neuromodulation treatments, it is not clear how this issue has been addressed in clinical trials. Given this gap in the literature, we reviewed articles on non-invasive brain stimulation in participants with depression or chronic pain, and in...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1352470

    authors: Thibaut A,O'Brien AT,Fregni F

    更新日期:2017-08-01 00:00:00

  • Could a new sensory pen assist in the early diagnosis of Parkinson's?

    abstract::Neurodegeneration in Parkinson's disease (PD) affects both the fine motor control of the fingers and gross movement of the upper limb. Handwriting examinations are commonly performed in the analysis of tremor in PD and there is validity in subjective assessment in the clinic. However, there is clinical need for a more...

    journal_title:Expert review of medical devices

    pub_type: 社论,评审

    doi:10.1586/17434440.2014.900437

    authors: Walker RW,Zietsma R,Gray WK

    更新日期:2014-05-01 00:00:00

  • Driving restriction in patients with cardiac implantable electronic devices: an overview of worldwide regulations.

    abstract::Introduction: It is common belief that driving with an implantable cardioverter defibrillator (ICD)/pacemaker (PM) might be associated with sudden cardiac incapacitation, road traffic accidents, and chance to harm to self and others. On the other hand, the ability to drive is highly valuable in the modern era, represe...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1742108

    authors: Imberti JF,Vitolo M,Proietti M,Diemberger I,Ziacchi M,Biffi M,Boriani G

    更新日期:2020-04-01 00:00:00

  • Wearable sensors to improve detection of patient deterioration.

    abstract:INTRODUCTION:Monitoring a patient's vital signs forms a basic component of care, enabling the identification of deteriorating patients and increasing the likelihood of improving patient outcomes. Several paper-based track and trigger warning scores have been developed to allow clinical evaluation of a patient and guida...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1563480

    authors: Joshi M,Ashrafian H,Aufegger L,Khan S,Arora S,Cooke G,Darzi A

    更新日期:2019-02-01 00:00:00

  • Top 100 cited noninvasive neuromodulation clinical trials.

    abstract:INTRODUCTION:Introduction: Transcranial direct current stimulation (tDCS) and transcranial magnetic stimulation (TMS) are noninvasive neuromodulation techniques used as therapeutic and research tools for several neuropsychiatric conditions. Given the exponential scientific growth of this field, we aimed to systematical...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615440

    authors: Lucena MFG,Teixeira PEP,Bonin Pinto C,Fregni F

    更新日期:2019-06-01 00:00:00

  • Does CircuLite Synergy assist device as partial ventricular support have a place in modern management of advanced heart failure?

    abstract::The discrepancy between the number of patients on the waiting list and available donor hearts has led to the successful development of left ventricular assist devices (LVAD) as a bridge to transplantation. The conventional LVADs are designed to provide full hemodynamic support for the end-stage failing heart. However,...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.985208

    authors: Mohite PN,Sabashnikov A,Simon AR,Weymann A,Patil NP,Unsoeld B,Bireta C,Popov AF

    更新日期:2015-01-01 00:00:00

  • Towards soft robotic devices for site-specific drug delivery.

    abstract::Considerable research efforts have recently been dedicated to the establishment of various drug delivery systems (DDS) that are mechanical/physical, chemical and biological/molecular DDS. In this paper, we report on the recent advances in site-specific drug delivery (site-specific, controlled, targeted or smart drug d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1091722

    authors: Alici G

    更新日期:2015-01-01 00:00:00

  • Advances in temporary mechanical support for treatment of cardiogenic shock.

    abstract::Mechanical circulatory support devices are the mainstay of treatment for severe cardiogenic shock refractory to pharmacologic therapy. Their evolution over the past few decades has been remarkable with a common theme of developing reliable, less bulky and more easily percutaneously implantable devices. The goal of thi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1086265

    authors: Koprivanac M,Kelava M,Soltesz E,Smedira N,Kapadia S,Brzezinski A,Alansari S,Moazami N

    更新日期:2015-01-01 00:00:00

  • How prosthetic design influences knee kinematics: a narrative review of tibiofemoral kinematics of healthy and joint-replaced knees.

    abstract:INTRODUCTION:To improve the total knee arthroplasty (TKA) prosthesis design, it is essential to study the kinematics of the tibiofemoral joint. Many studies have been conducted in this area; however, conflicting results and incomparable testing methods make it difficult to draw definitive conclusions or compare researc...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1564037

    authors: Meng F,Jaeger S,Sonntag R,Schroeder S,Smith-Romanski S,Kretzer JP

    更新日期:2019-02-01 00:00:00

  • Accuray CyberKnife image-guided radiosurgical system.

    abstract::Radiosurgery is the application of radiation therapy in an extremely precise manner. These techniques apply large bioequivalent doses of radiation to a small area in order to destroy tumor cells, while sparing surrounding normal tissues. Radiosurgery has been available for intracranial abnormalities since the 1950s bu...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.2.141

    authors: Welch WC,Gerszten PC

    更新日期:2005-03-01 00:00:00

  • Thermal scalpel to target cancer.

    abstract::Nanotechnology is increasingly applied to the field of medicine, particularly for the treatment of cancer. In this regard, gold nanoparticles can mediate hyperthermia induction and kill tumor cells upon laser irradiation, thereby functioning as a 'thermal scalpel'. Recent developments in gold nanoparticle design have ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.2.131

    authors: Everts M

    更新日期:2007-03-01 00:00:00

  • Robotics in invasive cardiac electrophysiology.

    abstract::Robotic systems allow for mapping and ablation of different arrhythmia substrates replacing hand maneuvering of intracardiac catheters with machine steering. Currently there are four commercially available robotic systems. Niobe magnetic navigation system (Stereotaxis Inc., St Louis, MO) and Sensei robotic navigation ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.916207

    authors: Shurrab M,Schilling R,Gang E,Khan EM,Crystal E

    更新日期:2014-07-01 00:00:00

  • Sorbent-based artificial liver devices: principles of operation, chemical effects and clinical results.

    abstract::Devices for support of patients with liver failure are of two types: bioartificial livers and artificial livers. Bioartificial livers include hepatocytes in bioreactors to provide both excretory and synthetic liver functions. Artificial livers use nonliving components to remove toxins of liver failure, supply nutrient...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.6.839

    authors: Carpentier B,Ash SR

    更新日期:2007-11-01 00:00:00

  • Device safety and effectiveness in the pediatric population: a US FDA perspective.

    abstract::The US FDA recognizes that there are many challenges to ensuring that medical devices are used responsibly and safely in the pediatric population. Education plays a key role, and manufacturers and healthcare providers must be informed of medical device issues unique to the pediatric population. Healthcare workers and ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.6.2.131

    authors: Samuels-Reid J,Cope JU,Morrison AE

    更新日期:2009-03-01 00:00:00

  • Systematic review of various laser intervention strategies for proliferative diabetic retinopathy.

    abstract::Diabetic retinopathy (DR) is a common complication of diabetes. DR obstructs blood supply to the retina and has serious and long-lasting detrimental effects on quality of life. Panretinal photocoagulation, a laser surgical intervention, is advocated for early treatment of DR to prevent visual loss; however, results fr...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.953057

    authors: Luo D,Zheng Z,Xu X,Fan Y,Zhu B,Liu K,Wang F,Sun X,Zou H,Xia X

    更新日期:2015-01-01 00:00:00

  • Development of inexpensive blood imaging systems: where are we now?

    abstract::Clinical applications in the developing world, such as malaria and anemia diagnosis, demand a change in the medical paradigm of expensive care given in central locations by highly trained professionals. There has been a recent explosion in optical technologies entering the consumer market through the widespread adopti...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1075388

    authors: Chu K,Smith ZJ,Wachsmann-Hogiu S

    更新日期:2015-01-01 00:00:00

  • Infection prevention methodologies for lower extremity total joint arthroplasty.

    abstract::Despite advances in our understanding of surgical site infections following total joint arthroplasty, this serious surgical complication continues to represent a substantial economic burden for the patient, the treating institution and the healthcare system. After increasing for the past decade, infection rates have s...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.76

    authors: Kapadia BH,Pivec R,Johnson AJ,Issa K,Naziri Q,Daley JA,Mont MA

    更新日期:2013-03-01 00:00:00

  • Performance of a new device for the clinical determination of light discomfort.

    abstract:PURPOSE:To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS:A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was asse...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1837623

    authors: Montés-Micó R,Cerviño A,Martínez-Albert N,García-Marqués JV,Marie S

    更新日期:2020-11-01 00:00:00

  • Innovative developments of the heart valves designed for use in ventricular assist devices.

    abstract::Prosthetic heart valves are routinely used for replacing diseased natural heart valves. Even today, after five decades of prosthetic heart valve development, in the authors opinion the main problem associated with these valves is the risk of thromboembolic complications caused by unnatural hemodynamics. Further growin...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.1.61

    authors: Goubergrits L,Affeld K,Kertzscher U

    更新日期:2005-01-01 00:00:00

  • Scientific evidence for the use of modern patellofemoral arthroplasty.

    abstract::Patellofemoral arthroplasty has been utilized as a treatment for isolated patellofemoral arthritis for more than 30 years. However, the use of this procedure remains controversial, as many surgeons prefer to use total knee arthroplasty, even for isolated patellofemoral arthritis. While historically, the results with t...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/erd.09.53

    authors: Gupta RR,Zywiel MG,Leadbetter WB,Bonutti P,Mont MA

    更新日期:2010-01-01 00:00:00