Abstract:
:Background: Papillary thyroid carcinoma is the most common type of thyroid cancer; despite its generally indolent course, patients often develop local post-operative recurrences. Re-operation, however, holds a high complication rate, while at the same time, not all patients benefit from radioiodine ablation. This systematic review investigates the application of laser ablation therapy (LAT) for cervical lymph node metastases as an additional treatment modality. Methods: This systematic review was conducted in accordance with the PRISMA Statement. Medline electronic database and Cochrane Library were searched for eligible articles. Results: Five studies were included in the systematic review. All studies included patients with metastatic lymph nodes from papillary thyroid carcinoma, that were unsuitable for further radioiodine or surgical treatment. Patients were treated with two different LAT devices. Regardless of the utilized assessment modalities, all researchers reported significant outcomes on local disease control. No permanent complications were observed. Conclusions: LAT is relatively safe and effective for the treatment of cervical metastatic lymph nodes in patients with papillary thyroid carcinoma.
journal_name
Expert Rev Med Devicesjournal_title
Expert review of medical devicesauthors
Spartalis E,Karagiannis SP,Plakopitis N,Theodori MA,Athanasiadis DI,Schizas D,Spartalis M,Troupis Tdoi
10.1080/17434440.2021.1864323subject
Has Abstractpub_date
2020-12-29 00:00:00pages
1-7eissn
1743-4440issn
1745-2422pub_type
杂志文章abstract:INTRODUCTION:This review describes the utilization of Visible Heart® methodologies for electrophysiologic studies, specifically in the investigation of monophasic action potential (MAP) recordings, with the aim to facilitate new catheter/device design and development that may lead to earlier diagnosis, treatment, and u...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2018.1493922
更新日期:2018-07-01 00:00:00
abstract::Cardiac resynchronization therapy (CRT) is a proven treatment adjunct for selected patients with heart failure and evidence of ventricular dyssynchrony. When applying most contemporary guidelines the accepted response rate has remained static with up to one-third of patients failing to respond. Empiric lateral/postero...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2014.885320
更新日期:2014-05-01 00:00:00
abstract::The subthalamic nucleus (STN) is the primary target for the chronic deep brain stimulation treatment of Parkinson's disease. STN neurons exhibit a variety of characteristic properties that may play a key role in the overall population response to deep brain stimulation. Neuroinformatics techniques, in particular compu...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.4.5.663
更新日期:2007-09-01 00:00:00
abstract::To reduce the toxic effects, related clinical problems and complications such as bleeding disorders associated with systemic anticoagulation, it has been hypothesized that by coating the surfaces of medical devices, such as stents, bypass grafts, extracorporeal circuits, guide wires and catheters, there will be a sign...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1586/17434440.3.2.245
更新日期:2006-03-01 00:00:00
abstract::Mechanical circulatory support devices are the mainstay of treatment for severe cardiogenic shock refractory to pharmacologic therapy. Their evolution over the past few decades has been remarkable with a common theme of developing reliable, less bulky and more easily percutaneously implantable devices. The goal of thi...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2015.1086265
更新日期:2015-01-01 00:00:00
abstract::This review focuses on the expanding role for biomaterials and polymer scaffolds in liver tissue engineering. Studies are subdivided into in vitro and in vivo approaches. The in vitro section of the review discusses the challenges specific to liver tissue engineering, and how the choice of scaffold and its structure i...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.3.1.21
更新日期:2006-01-01 00:00:00
abstract::Surgeons often encounter the challenge of treating acquired abdominal wall defects following abdominal surgery. The current standard of practice is to repair most defects using permanent synthetic mesh material. Mesh augments the strength of the weakened abdominal wall fascia and enables the hernia repair to be perfor...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.3.5.657
更新日期:2006-09-01 00:00:00
abstract:INTRODUCTION:Improved survival following single ventricle palliation has led to a large population of patients with a univentricular circulation, many of whom develop heart failure. Increasing experience with ventricular assist devices (VAD) in children has paved the way for VAD support in those with failing univentric...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2017.1332523
更新日期:2017-06-01 00:00:00
abstract::The introduction of retrievable inferior vena cava (IVC) filters was an important step in the evolution of deep vein thrombosis/pulmonary embolism management. Their removability makes them preferred to permanent filters in many cases. IVC filter retrieval often occurs at a suboptimal rate, leading to complications ass...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/erd.12.65
更新日期:2013-01-01 00:00:00
abstract::Liver biology, liver disease and its management present a myriad of challenges to clinicians. Difficulties arise in determining liver functional capacity, which must be effectively measured in a quantitative reproducible manner. Measurement of indocyanine green (ICG) clearance, an exceptional tool that has been used f...
journal_title:Expert review of medical devices
pub_type: 社论
doi:10.1586/17434440.2016.1126178
更新日期:2016-01-01 00:00:00
abstract:INTRODUCTION:Percutaneous transcatheter balloon angioplasty has evolved to the current mainstay treatment for salvage of dysfunctional dialysis access. Nonetheless, it is frequently associated with recurrent vessel restenosis and the need for multiple repeat treatments in order to maintain hemodynamic patency. Cutting-...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2016.1254548
更新日期:2016-12-01 00:00:00
abstract::The shortage of appropriate donor hearts and the expanding pool of patients waiting for a heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. With expanding clinical experience and continued technical advances, continuous-flow pumps are evolving...
journal_title:Expert review of medical devices
pub_type: 历史文章,杂志文章,评审
doi:10.1586/erd.11.62
更新日期:2012-01-01 00:00:00
abstract::The US FDA recognizes that there are many challenges to ensuring that medical devices are used responsibly and safely in the pediatric population. Education plays a key role, and manufacturers and healthcare providers must be informed of medical device issues unique to the pediatric population. Healthcare workers and ...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1586/17434440.6.2.131
更新日期:2009-03-01 00:00:00
abstract:INTRODUCTION:Despite the potential impact of missed visits on the outcomes of neuromodulation treatments, it is not clear how this issue has been addressed in clinical trials. Given this gap in the literature, we reviewed articles on non-invasive brain stimulation in participants with depression or chronic pain, and in...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2017.1352470
更新日期:2017-08-01 00:00:00
abstract:PURPOSE:To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS:A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was asse...
journal_title:Expert review of medical devices
pub_type: 杂志文章
doi:10.1080/17434440.2020.1837623
更新日期:2020-11-01 00:00:00
abstract::Infections related to electrophysiologic cardiac device placement are increasing dramatically and are associated with adverse outcomes. With the US population aging and living longer, cardiac devices are utilized in an older population with significant comorbidities, making the threat from infectious complications sig...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.5.2.183
更新日期:2008-03-01 00:00:00
abstract::Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir technology planting the ...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2016.1143356
更新日期:2016-01-01 00:00:00
abstract::Carotid stenosis is responsible for approximately 30% of strokes, and carotid endarterectomy is considered to be the gold-standard treatment. Carotid angioplasty and stenting (CAS) has been proposed as an alternative to surgery but the risk of neurological complications and brain embolism remains the major drawback to...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.5.5.591
更新日期:2008-09-01 00:00:00
abstract:INTRODUCTION:The applications of naturally obtained polymers are tremendously increased due to them being biocompatible, biodegradable, environmentally friendly and renewable in nature. Among them, polyhydroxyalkanoates are widely studied and they can be utilized in many areas of human life research such as drug delive...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2019.1615439
更新日期:2019-06-01 00:00:00
abstract::The discrepancy between the number of patients on the waiting list and available donor hearts has led to the successful development of left ventricular assist devices (LVAD) as a bridge to transplantation. The conventional LVADs are designed to provide full hemodynamic support for the end-stage failing heart. However,...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2015.985208
更新日期:2015-01-01 00:00:00
abstract:INTRODUCTION:Conventional surgical drills are rigid straight instruments used to make holes in bones. They lack the ability to follow a curved pathway, making them impractical for several surgical procedures. For this reason, there is a continuous need for improved devices for surgical drilling of curved holes. AREAS ...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2019.1596794
更新日期:2019-04-01 00:00:00
abstract::Atrial fibrillation (AF), the most common arrhythmia, has a major impact on both patient morbidity and healthcare economics. Hospital admissions due to AF have risen by two-thirds in the last 20 years. This is due mainly to an aging population and an increasing prevalence of chronic heart disease. Strategies for the m...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.4.4.549
更新日期:2007-07-01 00:00:00
abstract::Bladder-outflow obstruction is a common age-related clinical entity due to a variety of benign and malignant diseases of the prostate. Surgical treatment is not suitable for high-risk elderly patients who seek minimally invasive management. We present a prostatic thermo-expandable metal stent for treating bladder-outf...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/erd.09.13
更新日期:2009-07-01 00:00:00
abstract::In this review, surface modification of implant devices by immobilization of biological molecules is discussed. A brief introduction to the development of biomolecular surface science is presented, followed by a review of current activities in selected fields. Bone-contacting devices and some cardiovascular implant de...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.4.3.361
更新日期:2007-05-01 00:00:00
abstract:INTRODUCTION:Recurrent unexplained syncope is a well-established indication for an insertable cardiac monitor (ICM). Recently, the indications for an ICM have been expanded. AREAS COVERED:This review article discusses the current indications for ICMs and gives an overview of the latest generation of commercially avail...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2018.1557046
更新日期:2019-01-01 00:00:00
abstract::Insertable cardiac monitors (ICMs) are leadless subcutaneous devices that continuously monitor the heart rhythm and record events over a timeframe measured in years, allowing for the diagnosis of infrequent rhythm abnormalities that can be the cause of palpitations, syncope and stroke. To date, ICMs have primarily bee...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2014.953059
更新日期:2015-01-01 00:00:00
abstract::The RNS(®) System is the first commercially available device to provide closed-loop responsive brain stimulation. The system includes a cranially implanted neurostimulator that continually monitors the electrocorticogram through one or two depth and/or subdural cortical strip leads that are placed at the seizure focus...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2014.947274
更新日期:2014-11-01 00:00:00
abstract::Robotic systems allow for mapping and ablation of different arrhythmia substrates replacing hand maneuvering of intracardiac catheters with machine steering. Currently there are four commercially available robotic systems. Niobe magnetic navigation system (Stereotaxis Inc., St Louis, MO) and Sensei robotic navigation ...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2014.916207
更新日期:2014-07-01 00:00:00
abstract::Acute ischemic stroke is caused by occlusion of a cerebral artery, resulting in loss of brain tissue and neurologic deficits. However, a portion of the ischemic brain can be salvaged if blood flow is restored within an appropriate time frame. The past year has seen the publication of five positive randomized controlle...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1586/17434440.2016.1143772
更新日期:2016-01-01 00:00:00
abstract:INTRODUCTION:Monitoring a patient's vital signs forms a basic component of care, enabling the identification of deteriorating patients and increasing the likelihood of improving patient outcomes. Several paper-based track and trigger warning scores have been developed to allow clinical evaluation of a patient and guida...
journal_title:Expert review of medical devices
pub_type: 杂志文章,评审
doi:10.1080/17434440.2019.1563480
更新日期:2019-02-01 00:00:00