Percutaneous laser ablation of cervical metastatic lymph nodes in papillary thyroid carcinoma: clinical efficacy and anatomical considerations.

Abstract:

:Background: Papillary thyroid carcinoma is the most common type of thyroid cancer; despite its generally indolent course, patients often develop local post-operative recurrences. Re-operation, however, holds a high complication rate, while at the same time, not all patients benefit from radioiodine ablation. This systematic review investigates the application of laser ablation therapy (LAT) for cervical lymph node metastases as an additional treatment modality. Methods: This systematic review was conducted in accordance with the PRISMA Statement. Medline electronic database and Cochrane Library were searched for eligible articles. Results: Five studies were included in the systematic review. All studies included patients with metastatic lymph nodes from papillary thyroid carcinoma, that were unsuitable for further radioiodine or surgical treatment. Patients were treated with two different LAT devices. Regardless of the utilized assessment modalities, all researchers reported significant outcomes on local disease control. No permanent complications were observed. Conclusions: LAT is relatively safe and effective for the treatment of cervical metastatic lymph nodes in patients with papillary thyroid carcinoma.

journal_name

Expert Rev Med Devices

authors

Spartalis E,Karagiannis SP,Plakopitis N,Theodori MA,Athanasiadis DI,Schizas D,Spartalis M,Troupis T

doi

10.1080/17434440.2021.1864323

subject

Has Abstract

pub_date

2020-12-29 00:00:00

pages

1-7

eissn

1743-4440

issn

1745-2422

pub_type

杂志文章
  • The Visible Heart® project and methodologies: novel use for studying cardiac monophasic action potentials and evaluating their underlying mechanisms.

    abstract:INTRODUCTION:This review describes the utilization of Visible Heart® methodologies for electrophysiologic studies, specifically in the investigation of monophasic action potential (MAP) recordings, with the aim to facilitate new catheter/device design and development that may lead to earlier diagnosis, treatment, and u...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1493922

    authors: Schmidt MM,Iaizzo PA

    更新日期:2018-07-01 00:00:00

  • New developments in the delivery of cardiac resynchronization therapy: targeted lead placement, multi-site and endocardial pacing.

    abstract::Cardiac resynchronization therapy (CRT) is a proven treatment adjunct for selected patients with heart failure and evidence of ventricular dyssynchrony. When applying most contemporary guidelines the accepted response rate has remained static with up to one-third of patients failing to respond. Empiric lateral/postero...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.885320

    authors: Sohal M,Chen Z,Sammut E,Jackson T,Behar J,Carr-White G,Razavi R,Rinaldi CA

    更新日期:2014-05-01 00:00:00

  • Neuroinformatics and modeling of the basal ganglia: bridging pharmacology and physiology.

    abstract::The subthalamic nucleus (STN) is the primary target for the chronic deep brain stimulation treatment of Parkinson's disease. STN neurons exhibit a variety of characteristic properties that may play a key role in the overall population response to deep brain stimulation. Neuroinformatics techniques, in particular compu...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.5.663

    authors: Gillies A,Willshaw D

    更新日期:2007-09-01 00:00:00

  • Is there an alternative to systemic anticoagulation, as related to interventional biomedical devices?

    abstract::To reduce the toxic effects, related clinical problems and complications such as bleeding disorders associated with systemic anticoagulation, it has been hypothesized that by coating the surfaces of medical devices, such as stents, bypass grafts, extracorporeal circuits, guide wires and catheters, there will be a sign...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.3.2.245

    authors: Conn G,Kidane AG,Punshon G,Kannan RY,Hamilton G,Seifalian AM

    更新日期:2006-03-01 00:00:00

  • Advances in temporary mechanical support for treatment of cardiogenic shock.

    abstract::Mechanical circulatory support devices are the mainstay of treatment for severe cardiogenic shock refractory to pharmacologic therapy. Their evolution over the past few decades has been remarkable with a common theme of developing reliable, less bulky and more easily percutaneously implantable devices. The goal of thi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1086265

    authors: Koprivanac M,Kelava M,Soltesz E,Smedira N,Kapadia S,Brzezinski A,Alansari S,Moazami N

    更新日期:2015-01-01 00:00:00

  • Scaffolds for liver tissue engineering.

    abstract::This review focuses on the expanding role for biomaterials and polymer scaffolds in liver tissue engineering. Studies are subdivided into in vitro and in vivo approaches. The in vitro section of the review discusses the challenges specific to liver tissue engineering, and how the choice of scaffold and its structure i...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.1.21

    authors: Hammond JS,Beckingham IJ,Shakesheff KM

    更新日期:2006-01-01 00:00:00

  • Abdominal wall reconstruction using biological tissue grafts: present status and future opportunities.

    abstract::Surgeons often encounter the challenge of treating acquired abdominal wall defects following abdominal surgery. The current standard of practice is to repair most defects using permanent synthetic mesh material. Mesh augments the strength of the weakened abdominal wall fascia and enables the hernia repair to be perfor...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.5.657

    authors: Bellows CF,Alder A,Helton WS

    更新日期:2006-09-01 00:00:00

  • Ventricular assist devices for the failing univentricular circulation.

    abstract:INTRODUCTION:Improved survival following single ventricle palliation has led to a large population of patients with a univentricular circulation, many of whom develop heart failure. Increasing experience with ventricular assist devices (VAD) in children has paved the way for VAD support in those with failing univentric...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2017.1332523

    authors: Buratto E,Shi WY,Ye XT,Konstantinov IE

    更新日期:2017-06-01 00:00:00

  • Improving retrieval rates for retrievable inferior vena cava filters.

    abstract::The introduction of retrievable inferior vena cava (IVC) filters was an important step in the evolution of deep vein thrombosis/pulmonary embolism management. Their removability makes them preferred to permanent filters in many cases. IVC filter retrieval often occurs at a suboptimal rate, leading to complications ass...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.65

    authors: Dixon A,Stavropoulos SW

    更新日期:2013-01-01 00:00:00

  • Portable device for the analysis of liver function: a boon to liver surgery and critical care.

    abstract::Liver biology, liver disease and its management present a myriad of challenges to clinicians. Difficulties arise in determining liver functional capacity, which must be effectively measured in a quantitative reproducible manner. Measurement of indocyanine green (ICG) clearance, an exceptional tool that has been used f...

    journal_title:Expert review of medical devices

    pub_type: 社论

    doi:10.1586/17434440.2016.1126178

    authors: Mobley CM,Zarrinpar A

    更新日期:2016-01-01 00:00:00

  • Cutting balloons, covered stents and paclitaxel-coated balloons for the treatment of dysfunctional dialysis access.

    abstract:INTRODUCTION:Percutaneous transcatheter balloon angioplasty has evolved to the current mainstay treatment for salvage of dysfunctional dialysis access. Nonetheless, it is frequently associated with recurrent vessel restenosis and the need for multiple repeat treatments in order to maintain hemodynamic patency. Cutting-...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1254548

    authors: Kitrou P,Spiliopoulos S,Karnabatidis D,Katsanos K

    更新日期:2016-12-01 00:00:00

  • Miniaturization of left ventricular assist devices: the ongoing trend.

    abstract::The shortage of appropriate donor hearts and the expanding pool of patients waiting for a heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. With expanding clinical experience and continued technical advances, continuous-flow pumps are evolving...

    journal_title:Expert review of medical devices

    pub_type: 历史文章,杂志文章,评审

    doi:10.1586/erd.11.62

    authors: Garbade J,Bittner HB,Lehmann S,Mohr FW,Barten MJ

    更新日期:2012-01-01 00:00:00

  • Device safety and effectiveness in the pediatric population: a US FDA perspective.

    abstract::The US FDA recognizes that there are many challenges to ensuring that medical devices are used responsibly and safely in the pediatric population. Education plays a key role, and manufacturers and healthcare providers must be informed of medical device issues unique to the pediatric population. Healthcare workers and ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.6.2.131

    authors: Samuels-Reid J,Cope JU,Morrison AE

    更新日期:2009-03-01 00:00:00

  • Strategies for replacing non-invasive brain stimulation sessions: recommendations for designing neurostimulation clinical trials.

    abstract:INTRODUCTION:Despite the potential impact of missed visits on the outcomes of neuromodulation treatments, it is not clear how this issue has been addressed in clinical trials. Given this gap in the literature, we reviewed articles on non-invasive brain stimulation in participants with depression or chronic pain, and in...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1352470

    authors: Thibaut A,O'Brien AT,Fregni F

    更新日期:2017-08-01 00:00:00

  • Performance of a new device for the clinical determination of light discomfort.

    abstract:PURPOSE:To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS:A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was asse...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1837623

    authors: Montés-Micó R,Cerviño A,Martínez-Albert N,García-Marqués JV,Marie S

    更新日期:2020-11-01 00:00:00

  • Infections of electrophysiologic cardiac devices.

    abstract::Infections related to electrophysiologic cardiac device placement are increasing dramatically and are associated with adverse outcomes. With the US population aging and living longer, cardiac devices are utilized in an older population with significant comorbidities, making the threat from infectious complications sig...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.2.183

    authors: Uslan DZ

    更新日期:2008-03-01 00:00:00

  • From drug eluting stents to bioresorbable scaffolds; to new horizons in PCI.

    abstract::Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir technology planting the ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143356

    authors: Tenekecioglu E,Bourantas C,Abdelghani M,Zeng Y,Silva RC,Tateishi H,Sotomi Y,Onuma Y,Yılmaz M,Serruys PW

    更新日期:2016-01-01 00:00:00

  • Carotid angioplasty and stenting under protection: advantages and drawbacks.

    abstract::Carotid stenosis is responsible for approximately 30% of strokes, and carotid endarterectomy is considered to be the gold-standard treatment. Carotid angioplasty and stenting (CAS) has been proposed as an alternative to surgery but the risk of neurological complications and brain embolism remains the major drawback to...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.5.591

    authors: Henry M,Polydorou A,Henry I,Polydorou AD,Hugel M

    更新日期:2008-09-01 00:00:00

  • Polyhydroxyalkanoate (PHA): applications in drug delivery and tissue engineering.

    abstract:INTRODUCTION:The applications of naturally obtained polymers are tremendously increased due to them being biocompatible, biodegradable, environmentally friendly and renewable in nature. Among them, polyhydroxyalkanoates are widely studied and they can be utilized in many areas of human life research such as drug delive...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615439

    authors: Elmowafy E,Abdal-Hay A,Skouras A,Tiboni M,Casettari L,Guarino V

    更新日期:2019-06-01 00:00:00

  • Does CircuLite Synergy assist device as partial ventricular support have a place in modern management of advanced heart failure?

    abstract::The discrepancy between the number of patients on the waiting list and available donor hearts has led to the successful development of left ventricular assist devices (LVAD) as a bridge to transplantation. The conventional LVADs are designed to provide full hemodynamic support for the end-stage failing heart. However,...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.985208

    authors: Mohite PN,Sabashnikov A,Simon AR,Weymann A,Patil NP,Unsoeld B,Bireta C,Popov AF

    更新日期:2015-01-01 00:00:00

  • Surgical drilling of curved holes in bone - a patent review.

    abstract:INTRODUCTION:Conventional surgical drills are rigid straight instruments used to make holes in bones. They lack the ability to follow a curved pathway, making them impractical for several surgical procedures. For this reason, there is a continuous need for improved devices for surgical drilling of curved holes. AREAS ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1596794

    authors: Sendrowicz A,Scali M,Culmone C,Breedveld P

    更新日期:2019-04-01 00:00:00

  • Single-step atrial thrombus exclusion and transesophageal cardioversion in atrial fibrillation.

    abstract::Atrial fibrillation (AF), the most common arrhythmia, has a major impact on both patient morbidity and healthcare economics. Hospital admissions due to AF have risen by two-thirds in the last 20 years. This is due mainly to an aging population and an increasing prevalence of chronic heart disease. Strategies for the m...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.4.549

    authors: Mischke K,Schimpf T,Knackstedt C,Hanrath P,Schauerte P

    更新日期:2007-07-01 00:00:00

  • Treating bladder-outflow obstruction with thermo-expandable prostate metal stents.

    abstract::Bladder-outflow obstruction is a common age-related clinical entity due to a variety of benign and malignant diseases of the prostate. Surgical treatment is not suitable for high-risk elderly patients who seek minimally invasive management. We present a prostatic thermo-expandable metal stent for treating bladder-outf...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.13

    authors: Papatsoris AG,El-Husseiny T,Sawada Y,Takahashi T,Nagaoka A,Maan Z,Moraitis K,Masood J,Junaid I,Buchholz N

    更新日期:2009-07-01 00:00:00

  • Biomolecular modification of implant surfaces.

    abstract::In this review, surface modification of implant devices by immobilization of biological molecules is discussed. A brief introduction to the development of biomolecular surface science is presented, followed by a review of current activities in selected fields. Bone-contacting devices and some cardiovascular implant de...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.3.361

    authors: Morra M

    更新日期:2007-05-01 00:00:00

  • Insertable cardiac monitors: current indications and devices.

    abstract:INTRODUCTION:Recurrent unexplained syncope is a well-established indication for an insertable cardiac monitor (ICM). Recently, the indications for an ICM have been expanded. AREAS COVERED:This review article discusses the current indications for ICMs and gives an overview of the latest generation of commercially avail...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2018.1557046

    authors: Sakhi R,Theuns DAMJ,Szili-Torok T,Yap SC

    更新日期:2019-01-01 00:00:00

  • The Reveal LINQ insertable cardiac monitor.

    abstract::Insertable cardiac monitors (ICMs) are leadless subcutaneous devices that continuously monitor the heart rhythm and record events over a timeframe measured in years, allowing for the diagnosis of infrequent rhythm abnormalities that can be the cause of palpitations, syncope and stroke. To date, ICMs have primarily bee...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.953059

    authors: Tomson TT,Passman R

    更新日期:2015-01-01 00:00:00

  • The RNS System: responsive cortical stimulation for the treatment of refractory partial epilepsy.

    abstract::The RNS(®) System is the first commercially available device to provide closed-loop responsive brain stimulation. The system includes a cranially implanted neurostimulator that continually monitors the electrocorticogram through one or two depth and/or subdural cortical strip leads that are placed at the seizure focus...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.947274

    authors: Sun FT,Morrell MJ

    更新日期:2014-11-01 00:00:00

  • Robotics in invasive cardiac electrophysiology.

    abstract::Robotic systems allow for mapping and ablation of different arrhythmia substrates replacing hand maneuvering of intracardiac catheters with machine steering. Currently there are four commercially available robotic systems. Niobe magnetic navigation system (Stereotaxis Inc., St Louis, MO) and Sensei robotic navigation ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.916207

    authors: Shurrab M,Schilling R,Gang E,Khan EM,Crystal E

    更新日期:2014-07-01 00:00:00

  • Evolution of endovascular stroke therapies and devices.

    abstract::Acute ischemic stroke is caused by occlusion of a cerebral artery, resulting in loss of brain tissue and neurologic deficits. However, a portion of the ischemic brain can be salvaged if blood flow is restored within an appropriate time frame. The past year has seen the publication of five positive randomized controlle...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143772

    authors: Wallace AN,Kansagra AP,McEachern J,Moran CJ,Cross DT 3rd,Derdeyn CP

    更新日期:2016-01-01 00:00:00

  • Wearable sensors to improve detection of patient deterioration.

    abstract:INTRODUCTION:Monitoring a patient's vital signs forms a basic component of care, enabling the identification of deteriorating patients and increasing the likelihood of improving patient outcomes. Several paper-based track and trigger warning scores have been developed to allow clinical evaluation of a patient and guida...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1563480

    authors: Joshi M,Ashrafian H,Aufegger L,Khan S,Arora S,Cooke G,Darzi A

    更新日期:2019-02-01 00:00:00