Single-step atrial thrombus exclusion and transesophageal cardioversion in atrial fibrillation.

Abstract:

:Atrial fibrillation (AF), the most common arrhythmia, has a major impact on both patient morbidity and healthcare economics. Hospital admissions due to AF have risen by two-thirds in the last 20 years. This is due mainly to an aging population and an increasing prevalence of chronic heart disease. Strategies for the management of AF include prevention of thromboembolism, rate control and correction of the arrhythmia. Electrical cardioversion as one component of the treatment of AF requires the absence of atrial thrombi. Transesophageal echocardiography is used routinely for exclusion of atrial thrombi prior to cardioversion in many hospitals. This review presents preliminary data on the clinical use of devices for simultaneous transesophageal echocardiography and transesophageal cardioversion.

journal_name

Expert Rev Med Devices

authors

Mischke K,Schimpf T,Knackstedt C,Hanrath P,Schauerte P

doi

10.1586/17434440.4.4.549

subject

Has Abstract

pub_date

2007-07-01 00:00:00

pages

549-57

issue

4

eissn

1743-4440

issn

1745-2422

journal_volume

4

pub_type

杂志文章,评审
  • Electrothermal bipolar vessel sealing system (LigaSure) for hemostasis during thyroid surgery: a comprehensive review.

    abstract::Conventional hemostatic technologies utilized in thyroid surgery include clamp-and-tie, clips and monopolar and bipolar diathermy. Over the last decade, there has been a major shift towards utilizing newer hemostatic technologies, most notably the electrothermal bipolar vessel sealing systems (EBVS) and the Harmonic S...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.13.6

    authors: Butskiy O,Wiseman SM

    更新日期:2013-05-01 00:00:00

  • New developments in the delivery of cardiac resynchronization therapy: targeted lead placement, multi-site and endocardial pacing.

    abstract::Cardiac resynchronization therapy (CRT) is a proven treatment adjunct for selected patients with heart failure and evidence of ventricular dyssynchrony. When applying most contemporary guidelines the accepted response rate has remained static with up to one-third of patients failing to respond. Empiric lateral/postero...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.885320

    authors: Sohal M,Chen Z,Sammut E,Jackson T,Behar J,Carr-White G,Razavi R,Rinaldi CA

    更新日期:2014-05-01 00:00:00

  • Plugs for left atrial appendage occlusion: an overview of available devices.

    abstract:INTRODUCTION:Approximately one-third of all ischemic strokes and the ensuing health and economic burden can be attributed to the presence of atrial fibrillation (AF). The global prevalence of AF continues to rise, thus making it by far the most common diagnosed cardiac arrhythmia. Percutaneous left atrial appendage (LA...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1837621

    authors: Obeid S,Nietlispach F,Meier B

    更新日期:2020-11-01 00:00:00

  • Neural machine interfaces for controlling multifunctional powered upper-limb prostheses.

    abstract::This article investigates various neural machine interfaces for voluntary control of externally powered upper-limb prostheses. Epidemiology of upper limb amputation, as well as prescription and follow-up studies of externally powered upper-limb prostheses are discussed. The use of electromyographic interfaces and peri...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.1.43

    authors: Ohnishi K,Weir RF,Kuiken TA

    更新日期:2007-01-01 00:00:00

  • Evaluation of Surefire's precision direct-to-tumor embolization device to augment therapeutic response to intra-arterial, liver-directed therapies for patients with primary and secondary liver cancers.

    abstract::Patients with primary and secondary liver cancers generally have a poor prognosis with limited potentially curative options. Liver-directed, intra-arterial therapies such as selective internal radiotherapy (SIRT) and trans-arterial chemoembolization (TACE) are taking a larger role in the management of these patients. ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.2016.1164594

    authors: Kim AY,Miller A

    更新日期:2016-05-01 00:00:00

  • Robotics in invasive cardiac electrophysiology.

    abstract::Robotic systems allow for mapping and ablation of different arrhythmia substrates replacing hand maneuvering of intracardiac catheters with machine steering. Currently there are four commercially available robotic systems. Niobe magnetic navigation system (Stereotaxis Inc., St Louis, MO) and Sensei robotic navigation ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.916207

    authors: Shurrab M,Schilling R,Gang E,Khan EM,Crystal E

    更新日期:2014-07-01 00:00:00

  • The Lean and Agile Multi-dimensional Process (LAMP) - a new framework for rapid and iterative evidence generation to support health-care technology design and development.

    abstract::Introduction: Health technology assessments (HTA) are tools for policymaking and resource allocation. Early HTAs are increasingly used in design and development of new technologies. Conducting early HTAs is challenging, due to a lack of evidence and significant uncertainties in the technology and the market. A multi-d...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1743174

    authors: Ni M,Borsci S,Walne S,Mclister AP,Buckle P,Barlow JG,Hanna GB

    更新日期:2020-04-01 00:00:00

  • Surgical drilling of curved holes in bone - a patent review.

    abstract:INTRODUCTION:Conventional surgical drills are rigid straight instruments used to make holes in bones. They lack the ability to follow a curved pathway, making them impractical for several surgical procedures. For this reason, there is a continuous need for improved devices for surgical drilling of curved holes. AREAS ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1596794

    authors: Sendrowicz A,Scali M,Culmone C,Breedveld P

    更新日期:2019-04-01 00:00:00

  • Infection prevention methodologies for lower extremity total joint arthroplasty.

    abstract::Despite advances in our understanding of surgical site infections following total joint arthroplasty, this serious surgical complication continues to represent a substantial economic burden for the patient, the treating institution and the healthcare system. After increasing for the past decade, infection rates have s...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.76

    authors: Kapadia BH,Pivec R,Johnson AJ,Issa K,Naziri Q,Daley JA,Mont MA

    更新日期:2013-03-01 00:00:00

  • Advanced methods of spinal stimulation in the treatment of chronic pain: pulse trains, waveforms, frequencies, targets, and feedback loops.

    abstract:INTRODUCTION:Spinal cord stimulation has emerged as a state-of-the-art evidence-based treatment for chronic neuropathic pain and mixed nociceptive-neuropathic pain. In recent years, several newer devices and treatment algorithms have provided unique and effective ways of treating chronic pain by spinal cord stimulation...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1567325

    authors: Maheshwari A,Pope JE,Deer TR,Falowski S

    更新日期:2019-02-01 00:00:00

  • Device profile of the MobiusHD EVBA system for the treatment of resistant hypertension: overview of its mechanism of action, safety and efficacy.

    abstract:INTRODUCTION:Early promising results of renal nerve denervation awakened interest in developing medical device alternatives for patients with resistant hypertension. The subsequent sham-controlled renal nerve denervation randomized trials were disappointing leading researchers and innovators to explore alternative devi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1779054

    authors: Bates MC,Stone GW,Chen CY,Spiering W

    更新日期:2020-07-01 00:00:00

  • Non-invasive imaging techniques to assess myocardial perfusion.

    abstract:INTRODUCTION:Coronary artery disease affecting myocardial perfusion continues to be the leading cause of cardiovascular morbidity and mortality worldwide. While invasive evaluation based on coronary angiography and flow measurements still is considered the reference technique for assessing myocardial perfusion, technol...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1834844

    authors: Villemain O,Baranger J,Jalal Z,Lam C,Calais J,Pernot M,Cifra B,Friedberg MK,Mertens L

    更新日期:2020-11-01 00:00:00

  • Carotid angioplasty and stenting under protection: advantages and drawbacks.

    abstract::Carotid stenosis is responsible for approximately 30% of strokes, and carotid endarterectomy is considered to be the gold-standard treatment. Carotid angioplasty and stenting (CAS) has been proposed as an alternative to surgery but the risk of neurological complications and brain embolism remains the major drawback to...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.5.591

    authors: Henry M,Polydorou A,Henry I,Polydorou AD,Hugel M

    更新日期:2008-09-01 00:00:00

  • Evolution of endovascular stroke therapies and devices.

    abstract::Acute ischemic stroke is caused by occlusion of a cerebral artery, resulting in loss of brain tissue and neurologic deficits. However, a portion of the ischemic brain can be salvaged if blood flow is restored within an appropriate time frame. The past year has seen the publication of five positive randomized controlle...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143772

    authors: Wallace AN,Kansagra AP,McEachern J,Moran CJ,Cross DT 3rd,Derdeyn CP

    更新日期:2016-01-01 00:00:00

  • Scaffolds for liver tissue engineering.

    abstract::This review focuses on the expanding role for biomaterials and polymer scaffolds in liver tissue engineering. Studies are subdivided into in vitro and in vivo approaches. The in vitro section of the review discusses the challenges specific to liver tissue engineering, and how the choice of scaffold and its structure i...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.1.21

    authors: Hammond JS,Beckingham IJ,Shakesheff KM

    更新日期:2006-01-01 00:00:00

  • Device safety and effectiveness in the pediatric population: a US FDA perspective.

    abstract::The US FDA recognizes that there are many challenges to ensuring that medical devices are used responsibly and safely in the pediatric population. Education plays a key role, and manufacturers and healthcare providers must be informed of medical device issues unique to the pediatric population. Healthcare workers and ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.6.2.131

    authors: Samuels-Reid J,Cope JU,Morrison AE

    更新日期:2009-03-01 00:00:00

  • Electrosurgical devices: are we closer to finding the ideal appliance? A critical review of current evidence for the use of electrosurgical devices in general surgery.

    abstract::Over the last decade, the use of electrosurgical devices has become commonplace across all surgical specialities. The current market is large enough to warrant a comparative review of each device. This has even more impetus given the budgetary constraints of NHS organisations. This review aims to compare the benefits ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.2016.1134312

    authors: Sran H,Sebastian J,Hossain MA

    更新日期:2016-01-01 00:00:00

  • Mechanical circulatory support devices: methods to optimize hemodynamics during use.

    abstract:INTRODUCTION:Mechanical circulatory support (MCS) is an increasingly utilized mode of therapy in the management of advanced heart failure, both as bridge to heart transplantation and destination therapy. As MCS becomes more prevalent, it is ever more important to understand the complex hemodynamics of these devices, as...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1324292

    authors: Chung BB,Sayer G,Uriel N

    更新日期:2017-05-01 00:00:00

  • Is there an alternative to systemic anticoagulation, as related to interventional biomedical devices?

    abstract::To reduce the toxic effects, related clinical problems and complications such as bleeding disorders associated with systemic anticoagulation, it has been hypothesized that by coating the surfaces of medical devices, such as stents, bypass grafts, extracorporeal circuits, guide wires and catheters, there will be a sign...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.3.2.245

    authors: Conn G,Kidane AG,Punshon G,Kannan RY,Hamilton G,Seifalian AM

    更新日期:2006-03-01 00:00:00

  • Laparoscopic cholecystectomy: device-related errors revealed through a national database.

    abstract::Laparoscopic techniques represent a key milestone in the development of modern surgery, offering a step change in quality of care, patient satisfaction and efficiency in use of health service resources. Laparoscopy is most widely used for gall bladder surgery. As would be expected with the introduction of any new tech...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.43

    authors: Panesar SS,Salvilla SA,Patel B,Donaldson SL

    更新日期:2011-09-01 00:00:00

  • Cardima Surgical Ablation System: a novel tool for cardiac ablation in the treatment of atrial fibrillation.

    abstract::Atrial fibrillation is a pervasive and difficult heart rhythm problem for more than 3 million Americans. Patients are plagued by myriad symptoms and are exposed to the risk of stroke. Attempts to restore normal rhythm with drug therapy have been largely unsuccessful and the complications associated with long-term anti...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.9

    authors: Saltman AE

    更新日期:2009-05-01 00:00:00

  • Imaging techniques in pancreatic tumors.

    abstract::Conventional ultrasonography represents the first diagnostic imaging modality for the study of pancreatic tumors. Contrast-enhanced ultrasound has significantly improved the accuracy of first-line examination and may influence the choice of second-line investigations: multidetector computed tomography is considered th...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.09.67

    authors: D'Onofrio M,Gallotti A,Pozzi Mucelli R

    更新日期:2010-03-01 00:00:00

  • Miniaturization of left ventricular assist devices: the ongoing trend.

    abstract::The shortage of appropriate donor hearts and the expanding pool of patients waiting for a heart transplantation have led to growing interest in alternative strategies, particularly in mechanical circulatory support. With expanding clinical experience and continued technical advances, continuous-flow pumps are evolving...

    journal_title:Expert review of medical devices

    pub_type: 历史文章,杂志文章,评审

    doi:10.1586/erd.11.62

    authors: Garbade J,Bittner HB,Lehmann S,Mohr FW,Barten MJ

    更新日期:2012-01-01 00:00:00

  • A robot for transnasal surgery featuring needle-sized tentacle-like arms.

    abstract::This paper discusses a new class of robots known as concentric tube robots and their application to transnasal skull base surgery. The endonasal approach has clear benefits for patients, but the surgery presents challenges that strongly motivate the use of robotic tools. In this paper, the concentric tube robot concep...

    journal_title:Expert review of medical devices

    pub_type: 社论

    doi:10.1586/17434440.2013.854702

    authors: Gilbert H,Hendrick R,Remirez A,Webster R 3rd

    更新日期:2014-01-01 00:00:00

  • A clinical update on the mid-term clinical performance of the Ovation endograft.

    abstract:INTRODUCTION:The Ovation stent-graft uncouples the steps of fixation and sealing via a pair of polymer-filled inflatable rings. Apart from the well-documented early results, newer data emerged for mid-term results of Ovation and are presented in this review. AREAS COVERED:Aim of this article was to report all current ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1555467

    authors: Koutsoumpelis A,Georgakarakos E,Tasopoulou KM,Kontopodis N,Argyriou C,Georgiadis GS

    更新日期:2019-01-01 00:00:00

  • Developments in dosing aids and adherence devices for glaucoma therapy: current and future perspectives.

    abstract::Glaucoma is a leading cause of blindness worldwide. Currently, topical drops are the mainstay of treatment for patients who suffer from this chronic disease. Adherence to topical therapy is known to be affected by forgetfulness, frequent dosing requirements and physical limitations. Dosing and adherence aids are desig...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.2.261

    authors: Kahook MY

    更新日期:2007-03-01 00:00:00

  • Evaluation of Pipeline Flex delivery system for the treatment of unruptured aneurysms.

    abstract:INTRODUCTION:Refinements in endovascular technology have revolutionized the treatment of intracranial aneurysms (IAs) with the development of flow-diversion technology. The first generation of the Pipelin Embolization Device (PED) has demonstrated its safety and efficacy. However, the deployment technique was a difficu...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2016.1231573

    authors: Aguilar-Salinas P,Brasiliense LB,Gonsales D,Mitchell B,Lima A,Sauvageau E,Hanel R

    更新日期:2016-10-01 00:00:00

  • Lung volume reduction with endobronchial valves in patients with emphysema.

    abstract:INTRODUCTION:Bronchoscopic lung volume reduction with endobronchial valves is a recently acknowledged treatment option in patients with severe emphysema and absence of interlobar collateral ventilation. In endobronchial valve treatment, implantation of one-way valves leads to deflation of a hyperinflated lung lobe. Mul...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2018.1538780

    authors: Van Der Molen MC,Klooster K,Hartman JE,Slebos DJ

    更新日期:2018-11-01 00:00:00

  • From drug eluting stents to bioresorbable scaffolds; to new horizons in PCI.

    abstract::Drug eluting stents and particularly the fully bioresorbable drug-eluting scaffolds herald a new era in percutaneous treatment of coronary artery disease. There has been tremendous progress in drug eluting stents with fully biodegradable coating polymers and polymer-free devices with reservoir technology planting the ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143356

    authors: Tenekecioglu E,Bourantas C,Abdelghani M,Zeng Y,Silva RC,Tateishi H,Sotomi Y,Onuma Y,Yılmaz M,Serruys PW

    更新日期:2016-01-01 00:00:00

  • How prosthetic design influences knee kinematics: a narrative review of tibiofemoral kinematics of healthy and joint-replaced knees.

    abstract:INTRODUCTION:To improve the total knee arthroplasty (TKA) prosthesis design, it is essential to study the kinematics of the tibiofemoral joint. Many studies have been conducted in this area; however, conflicting results and incomparable testing methods make it difficult to draw definitive conclusions or compare researc...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1564037

    authors: Meng F,Jaeger S,Sonntag R,Schroeder S,Smith-Romanski S,Kretzer JP

    更新日期:2019-02-01 00:00:00