Using haptic stimulation to enhance auditory perception in hearing-impaired listeners.

Abstract:

INTRODUCTION:Hearing-assistive devices, such as hearing aids and cochlear implants, transform the lives of hearing-impaired people. However, users often struggle to locate and segregate sounds. This leads to impaired threat detection and an inability to understand speech in noisy environments. Recent evidence suggests that segregation and localization can be improved by providing missing sound-information through haptic stimulation. AREAS COVERED:This article reviews the evidence that haptic stimulation can effectively provide sound information. It then discusses the research and development required for this approach to be implemented in a clinically viable device. This includes discussion of what sound information should be provided and how that information can be extracted and delivered. EXPERT OPINION:Although this research area has only recently emerged, it builds on a significant body of work showing that sound information can be effectively transferred through haptic stimulation. Current evidence suggests that haptic stimulation is highly effective at providing missing sound-information to cochlear implant users. However, a great deal of work remains to implement this approach in an effective wearable device. If successful, such a device could offer an inexpensive, noninvasive means of improving educational, work, and social experiences for hearing-impaired individuals, including those without access to hearing-assistive devices.

journal_name

Expert Rev Med Devices

authors

Fletcher MD

doi

10.1080/17434440.2021.1863782

subject

Has Abstract

pub_date

2020-12-29 00:00:00

pages

1-12

eissn

1743-4440

issn

1745-2422

pub_type

杂志文章
  • Development of inexpensive blood imaging systems: where are we now?

    abstract::Clinical applications in the developing world, such as malaria and anemia diagnosis, demand a change in the medical paradigm of expensive care given in central locations by highly trained professionals. There has been a recent explosion in optical technologies entering the consumer market through the widespread adopti...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1075388

    authors: Chu K,Smith ZJ,Wachsmann-Hogiu S

    更新日期:2015-01-01 00:00:00

  • Cutting balloons, covered stents and paclitaxel-coated balloons for the treatment of dysfunctional dialysis access.

    abstract:INTRODUCTION:Percutaneous transcatheter balloon angioplasty has evolved to the current mainstay treatment for salvage of dysfunctional dialysis access. Nonetheless, it is frequently associated with recurrent vessel restenosis and the need for multiple repeat treatments in order to maintain hemodynamic patency. Cutting-...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2016.1254548

    authors: Kitrou P,Spiliopoulos S,Karnabatidis D,Katsanos K

    更新日期:2016-12-01 00:00:00

  • Laparoscopic cholecystectomy: device-related errors revealed through a national database.

    abstract::Laparoscopic techniques represent a key milestone in the development of modern surgery, offering a step change in quality of care, patient satisfaction and efficiency in use of health service resources. Laparoscopy is most widely used for gall bladder surgery. As would be expected with the introduction of any new tech...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.11.43

    authors: Panesar SS,Salvilla SA,Patel B,Donaldson SL

    更新日期:2011-09-01 00:00:00

  • Performance of a new device for the clinical determination of light discomfort.

    abstract:PURPOSE:To assess the performance of a new device for the clinical determination of light discomfort on a large sample of healthy human subjects. METHODS:A total of 489 subjects ranging from 20 to 70 years old (241 men, 248 women) were evaluated with the LUMIZ™ 100 to determine light discomfort. Repeatability was asse...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1080/17434440.2020.1837623

    authors: Montés-Micó R,Cerviño A,Martínez-Albert N,García-Marqués JV,Marie S

    更新日期:2020-11-01 00:00:00

  • Drug-eluting stents: from evidence to policy.

    abstract::Drug-eluting stents are a major breakthrough in cardiology, with the Cypher (Cordis Corporation) and Taxus (Boston Scientific) stents preventing 60-70% of repeat coronary revascularizations, compared with bare metal stents. Both evidence- and risk-based application of drug-eluting stents is expected to create relevant...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.1.1.49

    authors: Marchetti M

    更新日期:2004-09-01 00:00:00

  • Resurrection of hip resurfacing: what is the evidence?

    abstract::Total hip resurfacing has long been conceptually attractive to both surgeons and patients. However, historically it has been plagued by limited durability and marked acetabular bone loss. The recent development of wear-resistant bearings, such as metal-on-metal, has led to renewed interest in hip resurfacing in the or...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.3.6.755

    authors: Moroni A,Cadossi M,Bellenghi C,Romagnoli M,Bevoni R,Giannini S

    更新日期:2006-11-01 00:00:00

  • Biomolecular modification of implant surfaces.

    abstract::In this review, surface modification of implant devices by immobilization of biological molecules is discussed. A brief introduction to the development of biomolecular surface science is presented, followed by a review of current activities in selected fields. Bone-contacting devices and some cardiovascular implant de...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.3.361

    authors: Morra M

    更新日期:2007-05-01 00:00:00

  • Polyhydroxyalkanoate (PHA): applications in drug delivery and tissue engineering.

    abstract:INTRODUCTION:The applications of naturally obtained polymers are tremendously increased due to them being biocompatible, biodegradable, environmentally friendly and renewable in nature. Among them, polyhydroxyalkanoates are widely studied and they can be utilized in many areas of human life research such as drug delive...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1615439

    authors: Elmowafy E,Abdal-Hay A,Skouras A,Tiboni M,Casettari L,Guarino V

    更新日期:2019-06-01 00:00:00

  • Female sterilization.

    abstract::There has been considerable development and implementation of new contraceptive methods over the last 15 years. However, sterilization has remained the most widely used method around the world. Ideally, the procedure should be safe, have a high efficacy, be readily accessible, and be personally and culturally acceptab...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.4.525

    authors: Chapman L,Magos A

    更新日期:2008-07-01 00:00:00

  • Device safety and effectiveness in the pediatric population: a US FDA perspective.

    abstract::The US FDA recognizes that there are many challenges to ensuring that medical devices are used responsibly and safely in the pediatric population. Education plays a key role, and manufacturers and healthcare providers must be informed of medical device issues unique to the pediatric population. Healthcare workers and ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.6.2.131

    authors: Samuels-Reid J,Cope JU,Morrison AE

    更新日期:2009-03-01 00:00:00

  • The Reveal LINQ insertable cardiac monitor.

    abstract::Insertable cardiac monitors (ICMs) are leadless subcutaneous devices that continuously monitor the heart rhythm and record events over a timeframe measured in years, allowing for the diagnosis of infrequent rhythm abnormalities that can be the cause of palpitations, syncope and stroke. To date, ICMs have primarily bee...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.953059

    authors: Tomson TT,Passman R

    更新日期:2015-01-01 00:00:00

  • Modeling of the medical device development process.

    abstract::Models are abstract representations of reality that are built, analyzed and manipulated to augment the understanding of that reality. They can either be mental or codified but, in both cases, they contribute to good decision-making by ensuring that the right people use the right information at the right time. In order...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.12.36

    authors: Santos IC,Gazelle GS,Rocha LA,Tavares JM

    更新日期:2012-09-01 00:00:00

  • A critical appraisal of cardiac ablation technology for catheter-based treatment of atrial fibrillation.

    abstract::The advent of catheter ablation has revolutionized the treatment of supraventricular cardiac arrhythmias, including in the last few years, atrial fibrillation. The discovery of electrically active sleeves of atrial myocardium extending into the pulmonary veins has led to the development of pulmonary vein ostial ablati...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.59

    authors: Shah D

    更新日期:2011-01-01 00:00:00

  • Wearable sensors to improve detection of patient deterioration.

    abstract:INTRODUCTION:Monitoring a patient's vital signs forms a basic component of care, enabling the identification of deteriorating patients and increasing the likelihood of improving patient outcomes. Several paper-based track and trigger warning scores have been developed to allow clinical evaluation of a patient and guida...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1563480

    authors: Joshi M,Ashrafian H,Aufegger L,Khan S,Arora S,Cooke G,Darzi A

    更新日期:2019-02-01 00:00:00

  • Current interventional coronary applications of excimer laser.

    abstract::Excimer laser utilization as an adjunctive device for percutaneous coronary intervention has increased in the last few years. Many technical advancements have led to better results in terms of efficacy and safety with a low complication rate. In particular, excimer laser for thrombus-containing lesions is able to achi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2013.811846

    authors: Fracassi F,Roberto M,Niccoli G

    更新日期:2013-07-01 00:00:00

  • Plugs for left atrial appendage occlusion: an overview of available devices.

    abstract:INTRODUCTION:Approximately one-third of all ischemic strokes and the ensuing health and economic burden can be attributed to the presence of atrial fibrillation (AF). The global prevalence of AF continues to rise, thus making it by far the most common diagnosed cardiac arrhythmia. Percutaneous left atrial appendage (LA...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1837621

    authors: Obeid S,Nietlispach F,Meier B

    更新日期:2020-11-01 00:00:00

  • Surface coatings for ventricular assist devices.

    abstract::This article focuses on the surface engineering of ventricular assist devices (VADs) for the treatment of heart failure patients, which involves the modification of surfaces contacting blood in order to improve the blood compatibility (hemocompatibility) of the VADs. Following an introduction to the categorization and...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.6.1.51

    authors: Sin DC,Kei HL,Miao X

    更新日期:2009-01-01 00:00:00

  • Current and future developments in artificial muscles using electroactive polymers.

    abstract::For decades, electroactive polymers received relatively little attention due to their limited actuation capability. However, in the last 15 years, a series of electroactive polymer materials have emerged that produce a significant shape or size change in response to electrical stimulation. These materials have the clo...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2.6.731

    authors: Bar-Cohen Y

    更新日期:2005-11-01 00:00:00

  • Carotid angioplasty and stenting under protection: advantages and drawbacks.

    abstract::Carotid stenosis is responsible for approximately 30% of strokes, and carotid endarterectomy is considered to be the gold-standard treatment. Carotid angioplasty and stenting (CAS) has been proposed as an alternative to surgery but the risk of neurological complications and brain embolism remains the major drawback to...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.5.5.591

    authors: Henry M,Polydorou A,Henry I,Polydorou AD,Hugel M

    更新日期:2008-09-01 00:00:00

  • Neural machine interfaces for controlling multifunctional powered upper-limb prostheses.

    abstract::This article investigates various neural machine interfaces for voluntary control of externally powered upper-limb prostheses. Epidemiology of upper limb amputation, as well as prescription and follow-up studies of externally powered upper-limb prostheses are discussed. The use of electromyographic interfaces and peri...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.4.1.43

    authors: Ohnishi K,Weir RF,Kuiken TA

    更新日期:2007-01-01 00:00:00

  • Bicomponent electrospun scaffolds to design extracellular matrix tissue analogs.

    abstract::In the last decade, bicomponent fibers have been proposed to fabricate bio-inspired systems for tissue repair, regenerative medicine, medical healthcare and clinical applications. In comparison with monocomponent fibers, key advantage concerns their ability of self-adapting to the physiological conditions through an e...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1126505

    authors: Guarino V,Cirillo V,Ambrosio L

    更新日期:2016-01-01 00:00:00

  • Evolution of endovascular stroke therapies and devices.

    abstract::Acute ischemic stroke is caused by occlusion of a cerebral artery, resulting in loss of brain tissue and neurologic deficits. However, a portion of the ischemic brain can be salvaged if blood flow is restored within an appropriate time frame. The past year has seen the publication of five positive randomized controlle...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2016.1143772

    authors: Wallace AN,Kansagra AP,McEachern J,Moran CJ,Cross DT 3rd,Derdeyn CP

    更新日期:2016-01-01 00:00:00

  • Evaluation of the WATCHMAN left atrial appendage closure device.

    abstract::Left atrial appendage device occlusion for the preventions of systemic thromboembolism and stroke represents a major breakthrough in the field of cardiovascular disease. The wide prevalence of atrial fibrillation with devastating consequences of thromboembolic stroke as a result of thrombus arising from the left atria...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2014.940315

    authors: Alli O,Holmes D Jr

    更新日期:2014-11-01 00:00:00

  • Transcatheter aortic valve implantation: long-term clinical outcome and valve durability.

    abstract::Transcatheter aortic valve implantation (TAVI) is a widely used intervention in patients who are at high risk or contraindicated for cardiac surgery. The procedure is technically feasible in most patients and has very good mid-term clinical outcomes. In this special report, we evaluated the long-term outcome after TAV...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章

    doi:10.1586/17434440.2015.1063994

    authors: Sulzenko J,Tousek P,Kocka V,Widimsky P

    更新日期:2015-01-01 00:00:00

  • Theranostic approaches in nuclear medicine: current status and future prospects.

    abstract::Introduction: Theranostics is an emerging field in which diagnosis and specific targeted therapy are combined to achieve a personalized treatment approach to the patient. In nuclear medicine clinical practice, theranostics is often performed utilizing the same molecule labeled with two different radionuclides, one rad...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2020.1741348

    authors: Filippi L,Chiaravalloti A,Schillaci O,Cianni R,Bagni O

    更新日期:2020-04-01 00:00:00

  • Use of Amplatzer occluders for treatment of aorto-pulmonary fistulas - case and review of the literature.

    abstract:INTRODUCTION:the use of amplatzer occluder family in daily clinical practice has already overcome on-label indications, with growing clinical experience and the technological evolution of devices. Areas covered: We present the case of a patient with a very rare complication following proximal aortic surgery treated usi...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2017.1389636

    authors: Toušek P,Kočka V,Petr R,Ulman J,Hlavička J,Kolesár M

    更新日期:2017-11-01 00:00:00

  • Use of microdebriders in common rhinologic disorders.

    abstract::Powered instruments have been introduced into otorhinolaryngology practice over the last decade. These instruments were accepted immediately by many institutions, and continuing development has led to the current use of microdebriders in a variety of surgical procedures in otorhinolaryngology. In clinical rhinology, t...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/erd.10.7

    authors: Cingi C,Sayin I,Civelek S

    更新日期:2010-05-01 00:00:00

  • A review of thermal methods and technologies for diabetic foot assessment.

    abstract::Temperature analysis has been considered as a complementary method in medical evaluation and diagnosis. Several studies demonstrated that monitoring the temperature variations of the feet of diabetic patients can be helpful in the early identification of diabetic foot manifestations, and also in changing behaviors, wh...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1586/17434440.2015.1032251

    authors: Sousa P,Felizardo V,Oliveira D,Couto R,Garcia NM

    更新日期:2015-07-01 00:00:00

  • A clinical update on the mid-term clinical performance of the Ovation endograft.

    abstract:INTRODUCTION:The Ovation stent-graft uncouples the steps of fixation and sealing via a pair of polymer-filled inflatable rings. Apart from the well-documented early results, newer data emerged for mid-term results of Ovation and are presented in this review. AREAS COVERED:Aim of this article was to report all current ...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1555467

    authors: Koutsoumpelis A,Georgakarakos E,Tasopoulou KM,Kontopodis N,Argyriou C,Georgiadis GS

    更新日期:2019-01-01 00:00:00

  • Advanced methods of spinal stimulation in the treatment of chronic pain: pulse trains, waveforms, frequencies, targets, and feedback loops.

    abstract:INTRODUCTION:Spinal cord stimulation has emerged as a state-of-the-art evidence-based treatment for chronic neuropathic pain and mixed nociceptive-neuropathic pain. In recent years, several newer devices and treatment algorithms have provided unique and effective ways of treating chronic pain by spinal cord stimulation...

    journal_title:Expert review of medical devices

    pub_type: 杂志文章,评审

    doi:10.1080/17434440.2019.1567325

    authors: Maheshwari A,Pope JE,Deer TR,Falowski S

    更新日期:2019-02-01 00:00:00