Peripheral magnetic resonance angiography with continuous table movement in combination with high spatial and temporal resolution time-resolved MRA With a total single dose (0.1 mmol/kg) of gadobutrol at 3.0 T.

Abstract:

PURPOSE:To prove the concept of peripheral continuous table movement (CTM) MR-angiography (MRA) in combination with high spatial and temporal resolution time-resolved TWIST-MRA in a single MR-examination at 3.0 T with a single dose (0.1 mmol/kg) of gadobutrol in total. MATERIALS AND METHODS:We included 22 consecutive patients (15 m/7 f, mean age: 64 years) referred for peripheral MRA with clinical symptoms of peripheral arterial occlusive disease Fontaine stages II-IV. All of them underwent both CTM-MRA (TR: 2.4 ms/TE: 1.0 ms/flip angle: 21 degree) of the entire run-off vessels and TWIST-MRA (TR: 2.8 ms/TE: 1.1 ms/flip angle: 20 degree) of the calf station during a single MR-examination. All examinations were performed on a 3.0 T MR system (Tim Trio). Spatial resolution of the CTM-MRA datasets was technically limited to an acquired resolution of 1.2 x 1.2 x 1.96 mm3 reconstructed to 1.2 mm isotropic. The TWIST-MRA was acquired with 1.1 x 1.1 x 1.35 mm3 and reconstructed to 1.1 mm isotropic with a temporal resolution of 5.5 seconds in the calf station. A total of 0.1 mmol/kg BW gadobutrol diluted 1:1 with saline was injected at a flow rate of 1.5 mL/s of which 0.07 mmol/kg was administered for the CTM-MRA and 0.03 mmol/kg for the TWIST-MRA. CTM-MRA run off datasets were qualitatively assessed using a 4 point scale (4 = excellent, 1 = nondiagnostic) followed by TWIST-MRA datasets for the calf using the same scale. Additional relevant findings only visible in the TWIST-MRA were documented. RESULTS:All datasets could be evaluated with a total of 397 assessable segments. CTM-MRA was diagnostic in 99% (393/397 segments) with image quality judged as excellent in 54% (213/397 segments), good in 42% (14/397), and moderate in 4% (14/397) of analyzed segments respectively. Nondiagnostic image quality was seen in 1% (4/397 segments). Venous overlay in the calf station was found in 27% (6/22 patients). TWIST-MRA was diagnostic in 100% (115/115 segments), throughout with good or excellent image quality. In 14 of 22 patients additional relevant findings were detected by TWIST-MRA. CONCLUSION:Single-dose gadobutrol CTM-MRA in combination with a high spatial and temporal resolution TWIST-MRA at 3.0 T is a reliable technique with good image quality. Despite the use of single dose contrast agent large field of view coverage and dynamic images can be acquired. Because of its robustness, this imaging approach of the vasculature has great potential for a broad clinical use.

journal_name

Invest Radiol

journal_title

Investigative radiology

authors

Voth M,Haneder S,Huck K,Gutfleisch A,Schönberg SO,Michaely HJ

doi

10.1097/RLI.0b013e3181b4c26c

subject

Has Abstract

pub_date

2009-09-01 00:00:00

pages

627-33

issue

9

eissn

0020-9996

issn

1536-0210

journal_volume

44

pub_type

杂志文章
  • Low-Dose Characterization of Kidney Stones Using Spectral Detector Computed Tomography: An Ex Vivo Study.

    abstract:OBJECTIVES:The aim of this study was to investigate the feasibility of kidney stone composition analysis using spectral detector computed tomography scanner (SDCT) with normal- and low-dose imaging protocols. METHODS:A total of 154 stones harvested from nephrolithotripsy or nephrolithotomy with a known monocrystalline...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000468

    authors: Große Hokamp N,Salem J,Hesse A,Holz JA,Ritter M,Heidenreich A,Maintz D,Haneder S

    更新日期:2018-08-01 00:00:00

  • Value of in vivo T2 measurement for myocardial fibrosis assessment in diabetic mice at 11.75 T.

    abstract:OBJECTIVE:The aim of the study was to assess the value of in vivo T2 measurements to noninvasively quantify myocardial fibrosis in diabetic mice at 11.75 T. Diabetic cardiomyopathy is characterized by extracellular matrix alteration and microcirculation impairment. These conditions might provide electrical heterogeneit...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e318243e062

    authors: Bun SS,Kober F,Jacquier A,Espinosa L,Kalifa J,Bonzi MF,Kopp F,Lalevee N,Zaffran S,Deharo JC,Cozzone PJ,Bernard M

    更新日期:2012-05-01 00:00:00

  • Dual-Energy Computed Tomography-Based Display of Bone Marrow Edema in Incidental Vertebral Compression Fractures: Diagnostic Accuracy and Characterization in Oncological Patients Undergoing Routine Staging Computed Tomography.

    abstract:PURPOSE:The aim of this study was to evaluate the diagnostic performance of virtual noncalcium (VNCa) dual-energy computed tomography (DECT) reconstructions enabling visualization of bone marrow edema for characterization of incidental thoracolumbar compression fractures in routine thoracoabdominal staging computed tom...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000458

    authors: Frellesen C,Azadegan M,Martin SS,Otani K,DʼAngelo T,Booz C,Eichler K,Panahi B,Kaup M,Bauer RW,Vogl TJ,Wichmann JL

    更新日期:2018-07-01 00:00:00

  • A direct comparison of noninvasive coronary angiography by electron beam tomography and navigator-echo-based magnetic resonance imaging for the detection of restenosis following coronary angioplasty.

    abstract:RATIONALE AND OBJECTIVES:To compare electron beam tomography (EBT) with MR imaging (MRI) for detection of restenosis after coronary angioplasty (PTCA). METHODS:One hundred eighteen patients after PTCA were investigated. By EBT, 50 axial images were acquired (3-mm slice thickness, 120-160 mL radiographic contrast agent...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200207000-00005

    authors: Ropers D,Regenfus M,Stilianakis N,Birke S,Kessler W,Moshage W,Laub G,Daniel WG,Achenbach S

    更新日期:2002-07-01 00:00:00

  • Magnetic resonance osteodensitometry in human heel bones: correlation with quantitative computed tomography using different measuring parameters.

    abstract:RATIONALE AND OBJECTIVES:Density of trabecular bone structures in human heel bones was assessed by 3D magnetic resonance (MR) gradient echo imaging (GEI) with multiple echoes. Different spatial resolutions were applied to investigate the influence of the pixel size on signal characteristics in GEI and to find suitable ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-200007000-00001

    authors: Machann J,Schnatterbeck P,Raible A,Lutz O,Claussen CD,Schick F

    更新日期:2000-07-01 00:00:00

  • Effect of additional cations on the twitching reaction to intracarotid, nonionic contrast media in rabbits.

    abstract::Previous investigations in this laboratory have confirmed the observation of facial muscle twitching during intracarotid injections of nonionic contrast media (CM) in rabbits. The reaction appears to be a locally mediated effect. To further investigate this reaction, cortical electroencephalogram (EEG) and facial elec...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199009000-00010

    authors: Whisson CC,Evill CA,Sage MR,Wilson AJ

    更新日期:1990-09-01 00:00:00

  • In vivo and in vitro evaluation of Gd-DTPA-polylysine as a macromolecular contrast agent for magnetic resonance imaging.

    abstract::Polylysine covalently linked to moieties of gadopentetate (Gd-DTPA), for use as a macromolecular blood pool marker for contrast material-enhanced magnetic resonance imaging (MRI), was characterized by means of physicochemical measurements and pharmacokinetics in rats and rabbits and compared with Gd-DTPA. Gd-DTPA-poly...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199111000-00008

    authors: Schuhmann-Giampieri G,Schmitt-Willich H,Frenzel T,Press WR,Weinmann HJ

    更新日期:1991-11-01 00:00:00

  • Cerebral computed tomography angiography using a low tube voltage (80 kVp) and a moderate concentration of iodine contrast material: a quantitative and qualitative comparison with conventional computed tomography angiography.

    abstract:OBJECTIVE:To investigate the feasibility of an 80-kVp protocol using a moderate concentration contrast material (MC-CM) for cerebral computed tomography angiography by comparison with a conventional 120-kVp protocol using a high concentration contrast material (HC-CM). MATERIALS AND METHODS:Attenuation values and sign...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e31823076a4

    authors: Cho ES,Chung TS,Oh DK,Choi HS,Suh SH,Lee HK,Lee KH

    更新日期:2012-02-01 00:00:00

  • Magnetic resonance angiography. Application to the peripheral circulation.

    abstract::Magnetic resonance angiography (MRA) for application in the musculoskeletal system is progressing at a rapid pace. The clinical role of this new technique is still being developed, although a number of uses have already become well recognized, and MRA is diffusing into clinical practice. This article describes the bas...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199212002-00014

    authors: Harms SE,Flamig DP

    更新日期:1992-12-01 00:00:00

  • Contrast-to-noise-ratio measurements in three-dimensional magnetic resonance angiography.

    abstract:RATIONALE AND OBJECTIVES:The authors report on the development and preliminary validation of a technique for measuring contrast-to-noise ratio (CNR) at all points along selected vessel segments in the original three-dimensional magnetic resonance angiography (MRA) dataset. METHODS:Contrast-to-noise ratio dependencies ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199311000-00005

    authors: Du Y,Parker DL,Davis WL,Blatter DD

    更新日期:1993-11-01 00:00:00

  • Preliminary evaluation of Hexabrix for temporomandibular joint arthrography.

    abstract::A double-blind randomized study of ten patients compared Hexabrix 32% to Renografin-60 in TMJ arthrography. Equivalent volumes of contrast material were injected under fluoroscopic observation, with film quality and patient subjective response graded independently by three radiologists. In immediate arthrogram quality...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-198411001-00032

    authors: Katzberg RW

    更新日期:1984-11-01 00:00:00

  • Activities of the Conjoint Committee. Enhancement of diagnostic radiologic research and education.

    abstract::Even though we have made much progress over the last decade, much still needs to be done. I am personally very pleased with the excellent management and authority of my coauthor, Joe Frank, in assuming the Acting Directorship of our DRRP. You will be hearing more from him in the immediate future about this research pr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199304001-00014

    authors: Putman CE,Frank JA

    更新日期:1993-04-01 00:00:00

  • Searching for lung nodules. Visual dwell indicates locations of false-positive and false-negative decisions.

    abstract::Eye position recordings made while radiologists searched chest images for lung nodules showed that regions falsely reported positive or suspicious received prolonged visual attention. Correlation of regional fixation dwell time with independent ratings of image features indicated that more than 90% of false-positive d...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:

    authors: Kundel HL,Nodine CF,Krupinski EA

    更新日期:1989-06-01 00:00:00

  • Evaluation and validation of ureteric jet index by glomerular filtration rate.

    abstract:RATIONALE AND OBJECTIVES:Ureteric jet index (UJI), a newly developed technique derived from color Doppler ultrasonography, may hold promise in evaluating renal function because of its ability to evaluate individual renal function and the use of nonionizing radiation. To assess the usefulness of UJI, the authors in this...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199908000-00001

    authors: Chiu NT,Wu CC,Yao WJ,Tu DG,Lee BF,Tong YC,Pan CC

    更新日期:1999-08-01 00:00:00

  • Inhibition of restenosis in stented porcine coronary arteries: uptake of Paclitaxel from angiographic contrast media.

    abstract:RATIONALE AND OBJECTIVES:Paclitaxel added to angiographic contrast medium (CM) has been shown to inhibit restenosis in the porcine coronary overstretch model. This study determined early local tissue concentrations after the administration of different paclitaxel doses and preparations. MATERIALS AND METHODS:Fifteen p...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/01.rli.0000116125.96544.64

    authors: Speck U,Scheller B,Abramjuk C,Grossmann S,Mahnkopf D,Simon O

    更新日期:2004-03-01 00:00:00

  • Evaluation of postprocessing dual-energy methods in quantitative computed tomography. Part 2. Practical aspects.

    abstract::Three facets of dual-energy quantitative computed tomography are studied: (1) the algorithm for postprocessing data (the methods of Cann, Laval-Jeantet et al, Goodsitt et al [two methods], and Nickoloff et al); (2) the influence of choice of tissue-equivalent materials for calibration; and (3) the difference between c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199008000-00003

    authors: van Kuijk C,Grashuis JL,Steenbeek JC,Schütte HE,Trouerbach WT

    更新日期:1990-08-01 00:00:00

  • Image Quality and Geometric Distortion of Modern Diffusion-Weighted Imaging Sequences in Magnetic Resonance Imaging of the Prostate.

    abstract:PURPOSE:The aim of this study was to compare qualitative and quantitative image quality and geometric distortion of 4 magnetic resonance diffusion-weighted imaging (DWI) sequences of the prostate using comparable imaging parameters and similar acquisition times. METHODS AND MATERIALS:Axial T2-weighted turbo spin echo ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0000000000000429

    authors: Stocker D,Manoliu A,Becker AS,Barth BK,Nanz D,Klarhöfer M,Donati OF

    更新日期:2018-04-01 00:00:00

  • Opacification phase effects of angiographic contrast medium on left ventricular size and function: influence of initial ventricular volume and the pericardium.

    abstract::Prior studies of the opacification-phase effects of left ventricular (LV) injection of angiographic contrast medium (CM) on LV size and function have yielded discrepant results. A sensitive ultrasonic technique was used to measure LV dimension (Di) in 10 open-chest dogs with physiologic heart rates, and injection of s...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198209000-00009

    authors: LeWinter MM,Pavelec RS

    更新日期:1982-09-01 00:00:00

  • Experimental nephrotoxicity of the radiocontrast agents iohexol, ioxaglate, and iothalamate. An in vitro and in vivo study.

    abstract::The authors compared the renal toxicity of the low osmolality radiocontrast agents, iohexol and ioxaglate, and the ionic agent, iothalamate, at equivalent iodine dose, using experimental models in vitro and in vivo. In isolated perfused rat kidneys, all agents induced comparable biphasic hemodynamic changes, associate...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199104000-00008

    authors: Brezis M,Greenfeld Z,Herman M,Meyer JJ,Heyman SN,Rosen S

    更新日期:1991-04-01 00:00:00

  • Acute systemic and renal hemodynamic effects of meglumine/sodium diatrizoate 76% and iopamidol in euvolemic and dehydrated dogs.

    abstract::We examined the acute systemic and renal hemodynamic effects of intravenous meglumine/sodium diatrizoate-76% and iopamidol in euvolemic and dehydrated dogs. The physiologic responses were compared with acute changes in the level of an endogenous heparin-like material (EHM). One of eight dehydrated dogs receiving diatr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198610000-00005

    authors: Katzberg RW,Morris TW,Lasser EC,DiMarco PL,Merguerian PA,Ventura JA,Pabico RC,McKenna BA

    更新日期:1986-10-01 00:00:00

  • Validation of ultrafast computed tomographic left ventricular volume measurement.

    abstract::Left ventricular volume has been measured with ultrafast computed tomography. However, the accuracy with which this can be done is unknown. We therefore imaged with ultrafast computed tomography 11 rectangular phantoms, 20 to 225 ml, and 17 left ventricular casts, 15 to 112 ml. Two observers planimetered serial tomogr...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199101000-00006

    authors: Pietras RJ,Wolfkiel CJ,Veselik K,Roig E,Chomka EV,Brundage BH

    更新日期:1991-01-01 00:00:00

  • Magnetic resonance imaging in a spinal abscess model. Preliminary report.

    abstract:RATIONAL AND OBJECTIVES:Magnetic resonance (MR) scan technique and lesion detectability were evaluated using a newly developed spinal abscess model in the New Zealand White rabbit. METHODS:To create the lesion, an epidural needle was inserted under fluoroscopic guidance in the lumbar region and advanced to penetrate t...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199804000-00008

    authors: Runge VM,Williams NM,Lee C,Timoney JF

    更新日期:1998-04-01 00:00:00

  • Renal blood oxygenation level-dependent imaging: contribution of R2 to R2* values.

    abstract:OBJECTIVES:The aim of this study was to assess the impact of oral water and intravenous furosemide challenges on blood oxygenation level-dependent magnetic resonance imaging measurements in the kidney and to examine the contribution of R2 (=1/T2) to changes in R2* (=1/T2*). MATERIALS AND METHODS:This Health Insurance ...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/RLI.0b013e3182823591

    authors: Vivier PH,Storey P,Chandarana H,Yamamoto A,Tantillo K,Khan U,Zhang JL,Sigmund EE,Rusinek H,Babb JS,Bubenheim M,Lee VS

    更新日期:2013-07-01 00:00:00

  • Binary nature and radiographic identifiability of craniosynostosis.

    abstract:RATIONALE AND OBJECTIVES:Two independent gold standards and diagnoses from three-dimensional computed tomography (CT) images were used to examine the possibility that craniosynostosis is a binary abnormality that potentially may be diagnosed without error. METHODS:Surgical reports, histology of excised sutures, and th...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199410000-00005

    authors: Pilgram TK,Vannier MW,Marsh JL,Kraemer BB,Rayne SC,Gado MH,Moran CJ,McAlister WH,Shackelford GD,Hardesty RA

    更新日期:1994-10-01 00:00:00

  • Computed tomography-pathologic assessment of laser-induced necrosis in rat liver.

    abstract:RATIONALE AND OBJECTIVES:Interstitial laser photocoagulation (ILP) causes localized tissue necrosis. This study was performed to determine 1) whether the changes seen on computed tomography (CT) correspond to the necrosis pathologically, and 2) which CT technique best shows the necrosis. METHODS:Eighteen Wistar rats h...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-199312000-00014

    authors: Amin Z,Thurrell W,Spencer GM,Harries SA,Grant WE,Bown SG,Lees WR

    更新日期:1993-12-01 00:00:00

  • Educational objectives for diagnostic radiology residency training.

    abstract::A method of teaching radiology residents by identification of general and specific objectives to be accomplished during each time segment of the four-year training program has been developed. The objectives are incorporated into an educational contract that is signed by the resident and rotation director at the beginn...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198612000-00009

    authors: Howland WJ,Marler D,Bosshart D

    更新日期:1986-12-01 00:00:00

  • Pharmacokinetics and safety of iomeprol in healthy volunteers and in patients with renal impairment or end-stage renal disease requiring hemodialysis.

    abstract:RATIONALE AND OBJECTIVES:To present the results of two studies conducted to evaluate the pharmacokinetics and safety of iomeprol in healthy volunteers and in patients with various degrees of renal impairment. METHODS:In these two open-label, single-dose, phase I studies, a 50-mL dose of iomeprol 400 was administered i...

    journal_title:Investigative radiology

    pub_type: 临床试验,杂志文章

    doi:10.1097/00004424-200106000-00002

    authors: Lorusso V,Taroni P,Alvino S,Spinazzi A

    更新日期:2001-06-01 00:00:00

  • Systemic absorption of gallbladder sclerosing agents in the rabbit. A preliminary study.

    abstract::The absorbed levels of ethanol or tetracycline, used as gallbladder sclerosing agents, were measured in the systemic blood circulation of 16 rabbits. The maximal systemic level of ethanol was 46 mg/dl and of tetracycline was 4.6 micrograms/ml after 30 minutes of gallbladder exposure. Comparable serum levels would be c...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198605000-00005

    authors: Remley KB,Cubberley DA,Watanabe AS,Nelson JA,Colby TV

    更新日期:1986-05-01 00:00:00

  • Evaluation of the dehydration-rehydration method for production of contrast-carrying liposomes.

    abstract::We measured the amounts of three types of radiographic contrast media (RCM) that could be entrapped in liposomes prepared by the dehydration-rehydration vesicle (DRV) technique. To make DRVs, one initially makes water-containing, small unilamellar vesicles, adds contrast media and lyophilizes the mixture. Upon rehydra...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198802000-00009

    authors: Seltzer SE,Gregoriadis G,Dick R

    更新日期:1988-02-01 00:00:00

  • Spatial resolution analysis of computed tomographic images.

    abstract::Methods are presented for the quantification of spatial resolution in x-ray computed tomographic (CT) images. Model-dependent methods are derived and compared with model independent methods for computation of the Modulation Transfer Function (MTF). These techniques are applied to phantom images of point, line, edge, a...

    journal_title:Investigative radiology

    pub_type: 杂志文章

    doi:10.1097/00004424-198603000-00012

    authors: Assimakopoulos PA,Boyd DP,Jaschke W,Lipton MJ

    更新日期:1986-03-01 00:00:00