Characteristics of blood flow resistance under transverse vibration: red blood cell suspension in Dextran-40.

Abstract:

:Vibration under shear flow causes the reduction of flow resistance for shear-thinning fluids. The present study investigates the effect of vibration on the flow resistance of a nonaggregating red blood cell (RBC) suspension with a newly designed pressure-scanning capillary viscometer (PSCV). The PSCV was originally designed to measure non-Newtonian viscosity continuously over a range of shear rates at a time, which was slightly modified and used for the present study. Low-frequency vibration was applied perpendicular to the direction of the flow. The effect of the transverse vibration was investigated for both Newtonian fluids and nonaggregating RBC suspensions. The experimental results showed that the vibration had no effect on the flow resistance of the Newtonian fluids. However, the vibration caused a reduction of the flow resistance of the RBC suspension. The reduction of the flow resistance was strongly dependent on both frequency and amplitude of vibration.

journal_name

Ann Biomed Eng

authors

Shin S,Ku Y,Suh JS,Moon SY,Jang JY

doi

10.1114/1.1603751

subject

Has Abstract

pub_date

2003-10-01 00:00:00

pages

1077-83

issue

9

eissn

0090-6964

issn

1573-9686

journal_volume

31

pub_type

杂志文章
  • Rapid platelet accumulation leading to thrombotic occlusion.

    abstract::Platelet thrombosis under arterial conditions remains a large clinical problem. Previous in vitro experiments have concentrated on early adherence without thrombotic occlusion. We have developed a controllable hemodynamic system that creates intravascular thrombosis to occlusion. Lightly heparinized (3.5 USP units/mL)...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0296-3

    authors: Para A,Bark D,Lin A,Ku D

    更新日期:2011-07-01 00:00:00

  • Automatic Detection of Contracting Muscle Regions via the Deformation Field of Transverse Ultrasound Images: A Feasibility Study.

    abstract::Accurate identification of contracting muscles can help us to understand the muscle function in both physiological and pathological conditions. Conventional electromyography (EMG) have limited access to deep muscles, crosstalk, or instability in the recordings. Accordingly, a novel framework was developed to detect co...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02557-2

    authors: Zheng Y,Shin H,Kamper DG,Hu X

    更新日期:2021-01-01 00:00:00

  • Needle electrode-based electromechanical reshaping of cartilage.

    abstract::Electromechanical reshaping (EMR) of cartilage provides an alternative to the classic surgical techniques of modifying the shape of facial cartilages. The original embodiment of EMR required surface electrodes to be in direct contact with the entire cartilage region being reshaped. This study evaluates the feasibility...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-0088-1

    authors: Manuel CT,Foulad A,Protsenko DE,Sepehr A,Wong BJ

    更新日期:2010-11-01 00:00:00

  • Genetics of energetics: transcriptional responses in cardiac metabolism.

    abstract::Recent evidence suggests that energy substrate metabolism forms the link between gene expression and contractile function of the heart. This hypothesis draws on three seemingly unconnected observations, made in 1941 by three different investigators. The first gave rise to the concept of the dynamic nature of body cons...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章,评审

    doi:10.1114/1.1312187

    authors: Taegtmeyer H

    更新日期:2000-08-01 00:00:00

  • Development of a Three-Dimensional Adipose Tissue Model for Studying Embryonic Exposures to Obesogenic Chemicals.

    abstract::Obesity is a rising issue especially in the United States that can lead to heart problems, type II diabetes, and respiratory problems. Since the 1970s, obesity rates in the United States have more than doubled in adults and children. Recent evidence suggests that exposure to certain chemicals, termed "obesogens," in u...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1752-x

    authors: Wang RY,Abbott RD,Zieba A,Borowsky FE,Kaplan DL

    更新日期:2017-07-01 00:00:00

  • Prediction of hip fracture can be significantly improved by a single biomedical indicator.

    abstract::Femoral neck fractures are a relevant clinical and social problem. The aim of this study was to improve the prediction of patients at-risk of femoral neck fracture with respect to the current densitometric-based methods. In particular, finite element models were used to assess the prediction accuracy obtained by combi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1495866

    authors: Testi D,Viceconti M,Cappello A,Gnudi S

    更新日期:2002-06-01 00:00:00

  • Estimation of Reynolds shear stresses during pulsatile flow in the region of aortic valves.

    abstract::Some investigators have attempted to estimate the Reynolds shear stress on the basis of a single component of velocity. The purpose of this investigation is to determine the validity of such estimates in a complex flow field, such as occurs in the cardiovascular system in the region of the aortic valve. Turbulent velo...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02371247

    authors: Walburn FJ,Sabbah HN,Stein PD

    更新日期:1985-01-01 00:00:00

  • 3D Printed Vascular Networks Enhance Viability in High-Volume Perfusion Bioreactor.

    abstract::There is a significant clinical need for engineered bone graft substitutes that can quickly, effectively, and safely repair large segmental bone defects. One emerging field of interest involves the growth of engineered bone tissue in vitro within bioreactors, the most promising of which are perfusion bioreactors. Usin...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-016-1662-y

    authors: Ball O,Nguyen BB,Placone JK,Fisher JP

    更新日期:2016-12-01 00:00:00

  • Mathematical models of the spatial distribution of retinal oxygen tension and consumption, including changes upon illumination.

    abstract::To better understand oxygen utilization by the retina, a mathematical model of oxygen diffusion and consumption in the cat outer, avascular retina was developed by analyzing previously recorded profiles of oxygen tension (PO2) as a function of retinal depth. Simple diffusion modelling of the oxygen distribution throug...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368415

    authors: Haugh LM,Linsenmeier RA,Goldstick TK

    更新日期:1990-01-01 00:00:00

  • Length-Change Patterns of the Collateral Ligaments During Functional Activities After Total Knee Arthroplasty.

    abstract::This study aimed to quantify the elongation patterns of the collateral ligaments following TKA during functional activities of daily living. Using mobile video-fluoroscopy to capture radiographic images of the knee in a group of six patients, each with an ultra-congruent knee implant, tibiofemoral kinematics were reco...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-020-02459-3

    authors: Hosseini Nasab SH,Smith CR,Schütz P,Damm P,Trepczynski A,List R,Taylor WR

    更新日期:2020-04-01 00:00:00

  • Pulmonary vascular resistance and impedance in isolated mouse lungs: effects of pulmonary emboli.

    abstract::To study pulsatile pressure-flow rate relationships in the intact pulmonary vascular network of mice, we developed a protocol for measuring pulmonary vascular resistance and impedance in isolated, ventilated, and perfused mouse lungs. We used pulmonary emboli to validate the effect of vascular obstruction on resistanc...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-005-9050-z

    authors: Tuchscherer HA,Webster EB,Chesler NC

    更新日期:2006-04-01 00:00:00

  • The pressure-volume relation in the left ventricle and the pump function of the heart.

    abstract::The concept of body force (force per unit volume) is introduced to account for the effect of the force generated in the radial direction by the active state of the myocardium in an elastic model of the left ventricle represented as a thick-walled cylinder contracting symmetrically. Experimental evidence for the validi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368077

    authors: Shoucri RM

    更新日期:1991-01-01 00:00:00

  • Reinforcement of Mono- and Bi-layer Poly(Ethylene Glycol) Hydrogels with a Fibrous Collagen Scaffold.

    abstract::Biomaterial-based tissue engineering strategies hold great promise for osteochondral tissue repair. Yet significant challenges remain in joining highly dissimilar materials to achieve a biomimetic, mechanically robust design for repairing interfaces between soft tissue and bone. This study sought to improve interfacia...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-015-1337-0

    authors: Kinneberg KR,Nelson A,Stender ME,Aziz AH,Mozdzen LC,Harley BA,Bryant SJ,Ferguson VL

    更新日期:2015-11-01 00:00:00

  • Intelligent multichannel stimulator for the study of cardiac arrhythmias.

    abstract::An intelligent multichannel stimulator (IMS) has been designed and built for use in a cardiac research environment. The device is capable of measuring and responding to cardiac electrophysiological phenomena in real time with carefully timed and placed electrical stimuli. The system consists of 16 channels of sense/st...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1451077

    authors: Johnson PL,Newton JC,Rollins DL,Knisley SB,Ideker RE,Smith WM

    更新日期:2002-02-01 00:00:00

  • An evaluation of population D-optimal designs via pharmacokinetic simulations.

    abstract::One goal of large scale clinical trials is to determine how a drug is processed by, and cleared from, the human body [i.e., its pharmacokinetic (PK) properties] and how these PK properties differ between individuals in a population (i.e., its population PK properties). Due to the high cost of these studies and the lim...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1533074

    authors: Hooker AC,Foracchia M,Dodds MG,Vicini P

    更新日期:2003-01-01 00:00:00

  • Measurement of signal and noise characteristics in ongoing auditory brainstem response averaging.

    abstract::Although diagnostic testing with auditory evoked potentials (EPs) has become routine, quantitative measurements of signal and noise are still lacking. In this study, current signal, power, noise power, and signal-to-noise ratio (SNR) estimation formulas are reviewed and applied to auditory brainstem response averaging...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684183

    authors: Ozdamar O,Delgado RE

    更新日期:1996-11-01 00:00:00

  • Real-Time linux dynamic clamp: a fast and flexible way to construct virtual ion channels in living cells.

    abstract::We describe a system for real-time control of biological and other experiments. This device, based around the Real-Time Linux operating system, was tested specifically in the context of dynamic clamping, a demanding real-time task in which a computational system mimics the effects of nonlinear membrane conductances in...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1408929

    authors: Dorval AD,Christini DJ,White JA

    更新日期:2001-10-01 00:00:00

  • Bymixer provides on-line calibration of measurement of CO2 volume exhaled per breath.

    abstract::The measurement of CO2 volume exhaled per breath (VCO2.br) can be determined during anesthesia by the multiplication and integration of tidal flow (V) and PCO2. During side-stream capnometry, PCO2 must be advanced in time by transport delay (TD), the time to suction gas through the sampling tube. During ventilation, T...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02738547

    authors: Breen PH,Serina ER

    更新日期:1997-01-01 00:00:00

  • An optimization-based simultaneous approach to the determination of muscular, ligamentous, and joint contact forces provides insight into musculoligamentous interaction.

    abstract::Typical inverse dynamics approaches to the calculation of muscle, ligament, and joint contact forces are based on a step-wise solution of the equations of motion. This approach is therefore limited in its ability to provide insight as to the muscular, ligamentous, and articular interactions that create joint stability...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-011-0303-8

    authors: Cleather DJ,Bull AM

    更新日期:2011-07-01 00:00:00

  • Interstitial stress and fluid pressure within a growing tumor.

    abstract::A solid tumor is composed of a population of cells that is expanding as a result of cell division. With dense cell packing, the solid matrix of the interstitial tissue is subject to residual stress. In addition, elevated interstitial fluid pressure (IFP) has been reported by researchers for a number of solid tumors. T...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1114/1.1554923

    authors: Sarntinoranont M,Rooney F,Ferrari M

    更新日期:2003-03-01 00:00:00

  • Two-dimensional dynamic simulation of platelet activation during mechanical heart valve closure.

    abstract::A major drawback in the operation of mechanical heart valve prostheses is thrombus formation in the near valve region. Detailed flow analysis in this region during the valve closure phase is of interest in understanding the relationship between shear stress and platelet activation. A fixed-grid Cartesian mesh flow sol...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9194-5

    authors: Krishnan S,Udaykumar HS,Marshall JS,Chandran KB

    更新日期:2006-10-01 00:00:00

  • Role of Rac and Rho-GDI alpha in the frequency-dependent expression of h1-calponin in vascular smooth muscle cells under cyclic mechanical strain.

    abstract::Phenotype transformation of vascular smooth muscle cells (VSMCs) has been reported to be directly influenced by the frequency of mechanical strain. This study explored the effects of different frequencies of mechanical strain on expression of phenotype marker h1-calponin and the possible mechanism. VSMCs were subjecte...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-008-9521-0

    authors: Qu MJ,Liu B,Qi YX,Jiang ZL

    更新日期:2008-09-01 00:00:00

  • Computational tools for quantitative breast morphometry based on 3D scans.

    abstract::Quantitative analysis of breast morphometry is critical to breast plastic surgery. Recently, three-dimensional (3D) photography has emerged as a strong new alternative for breast morphometry analysis in comparison to other existing techniques. 3D photography enables the capture of the entire breast surface topology vi...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-010-9971-z

    authors: Chen D,Chittajallu DR,Passalis G,Kakadiaris IA

    更新日期:2010-05-01 00:00:00

  • A small angle light scattering device for planar connective tissue microstructural analysis.

    abstract::The planar fibrous connective tissues of the body are composed of a dense extracellular network of collagen and elastin fibers embedded in a ground matrix, and thus can be thought of as biocomposites. Thus, the quantification of fiber architecture is an important step in developing an understanding of the mechanics of...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02684845

    authors: Sacks MS,Smith DB,Hiester ED

    更新日期:1997-07-01 00:00:00

  • Continuous blood density measurement for hemodynamic monitoring: an analysis of its accuracy and sensitivity.

    abstract::Continuous measurement of arterial blood density after bolus injection of fluids of different density into the right atrium has been used to measure cardiac output and mean transit time through the central circulation. The transit time distribution for density, however, differs from that for plasma-phase tracers such ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02368628

    authors: Ligas JR,Moslehi F,Epstein MA

    更新日期:1993-07-01 00:00:00

  • Supraphysiological thermal injury in different human bladder carcinoma cell lines.

    abstract::Depending on the duration of exposure to supraphysiological temperatures, cellular proteins and organelles can suffer from structural alternations and irreversible denaturation, which may induce cell death. The thermotolerance of three human urinary bladder carcinoma cell lines, TSGH-8301, J82 and TCC-SUP (cytological...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-009-9773-3

    authors: Jen CP,Huang CT,Tsai CH

    更新日期:2009-11-01 00:00:00

  • A computerized mass spectrometer and flowmeter system for respiratory gas measurements.

    abstract::Instrumentation systems for breath-to-breath analysis of respiratory gas exchange have been faulted by phase lags between various flow and composition signals and by difficulties in gathering and processing large amounts of data. The system described here represents an attempt to overcome these problems. Phase delays ...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/BF02367493

    authors: Sodal IE,Swanson GD,Micco AJ,Sprague F,Ellis DG

    更新日期:1983-01-01 00:00:00

  • Preparation of chitosan/hydroxyapatite substrates with controllable osteoconductivity tracked by AFM.

    abstract::In this study, cell-material adhesive strength and cellular mechanical properties were measured using atomic force microscopy (AFM) to track cell attachment and osteogenic differentiation. First, chitosan substrates were treated with simulated body fluid (SBF) for various periods, resulting in substrates with differen...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-014-1162-x

    authors: Ho MH,Li CH,Hsiao SW,Thien DV

    更新日期:2015-04-01 00:00:00

  • Computational approach to estimating the effects of blood properties on changes in intra-stent flow.

    abstract::In this study various blood rheological assumptions are numerically investigated for the hemodynamic properties of intra-stent flow. Non-newtonian blood properties have never been implemented in blood coronary stented flow investigation, although its effects appear essential for a correct estimation and distribution o...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-006-9123-7

    authors: Benard N,Perrault R,Coisne D

    更新日期:2006-08-01 00:00:00

  • Constitutive modeling of pia-arachnoid complex.

    abstract::The pia-arachnoid complex (PAC) covering the brain plays an important role in the mechanical response of the brain during impact or inertial loading. Recent studies have revealed the complicated material behavior of the PAC. In this study, the nonlinear viscoelastic, transversely isotropic material properties of the P...

    journal_title:Annals of biomedical engineering

    pub_type: 杂志文章

    doi:10.1007/s10439-013-0948-6

    authors: Jin X,Mao H,Yang KH,King AI

    更新日期:2014-04-01 00:00:00