SSFP-based MR thermometry.

Abstract:

:Of the various techniques employed to quantify temperature changes by MR, proton resonance frequency (PRF) shift-based phase-difference imaging (PDI) is the most accurate and widely used. However, PDI is associated with various artifacts. Motivated by these limitations, we developed a new method to monitor temperature changes by MRI using the balanced steady-state free precession (balanced-SSFP) pulse sequence. Magnitude images obtained with the SSFP pulse sequence were used to find the PRF shift, which is proportional to temperature change. Spatiotemporal temperature maps were successfully reconstructed with this technique in gel phantom experiments and a rabbit model. The results show that the balanced-SSFP-based method is a promising new technique for monitoring temperature.

journal_name

Magn Reson Med

authors

Paliwal V,El-Sharkawy AM,Du X,Yang X,Atalar E

doi

10.1002/mrm.20231

subject

Has Abstract

pub_date

2004-10-01 00:00:00

pages

704-8

issue

4

eissn

0740-3194

issn

1522-2594

journal_volume

52

pub_type

杂志文章
  • High-frequency subband compressed sensing MRI using quadruplet sampling.

    abstract:PURPOSE:To present and validate a new method that formalizes a direct link between k-space and wavelet domains to apply separate undersampling and reconstruction for high- and low-spatial-frequency k-space data. THEORY AND METHODS:High- and low-spatial-frequency regions are defined in k-space based on the separation o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.24592

    authors: Sung K,Hargreaves BA

    更新日期:2013-11-01 00:00:00

  • Validation of 13C NMR measurements of liver glycogen in vivo.

    abstract::The natural abundance 13C NMR intensity of the glycogen C1 resonance was measured in the surgically exposed liver of rabbits in vivo (n = 17) by integration from 98 to 104 ppm and compared double blindedly to the subsequent biochemical measurement. Coil loading was measured each time from a reference sphere at the coi...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910310602

    authors: Gruetter R,Magnusson I,Rothman DL,Avison MJ,Shulman RG,Shulman GI

    更新日期:1994-06-01 00:00:00

  • Unifying linear prior-information-driven methods for accelerated image acquisition.

    abstract::In the ongoing quest for faster imaging and higher spatial resolution, several methods have been developed to speed up data acquisition by incorporating prior information about the object being imaged. This study shows that many of these methods can be integrated into a single common equation. The unified framework pr...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1242

    authors: Tsao J,Behnia B,Webb AG

    更新日期:2001-10-01 00:00:00

  • Sensitivity of feedback-enhanced MRI contrast to macroscopic and microscopic field variations.

    abstract::Nonlinear feedback interactions have been shown to amplify contrast due to small differences in resonance frequency arising from microscopic susceptibility variations. Determining whether the selectivity of feedback-based contrast enhancement for small resonance frequency variations remains valid even in the presence ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21584

    authors: Huang SY,Yang SS,Lin YY

    更新日期:2009-04-01 00:00:00

  • Rigid-body motion correction with self-navigation MRI.

    abstract::The use of phase correlation to detect rigid-body translational motion is reviewed and applied to individual echotrains in turbo-spin-echo data acquisition. It is shown that when the same echotrain is acquired twice, the subsampled correlation provides an array of delta-functions, from which the motion that occurred b...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21883

    authors: Mendes J,Kholmovski E,Parker DL

    更新日期:2009-03-01 00:00:00

  • Evolution of the longitudinal magnetization for pulse sequences using a fast spin-echo readout: application to fluid-attenuated inversion-recovery and double inversion-recovery sequences.

    abstract::The fast spin-echo (FSE) sequence is frequently used as a fast data-readout technique in conjunction with other pulse sequence elements, such as in fluid-attenuated inversion-recovery (FLAIR) and double inversion-recovery (DIR) sequences. In order to implement those pulse sequences, an understanding is required of how...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20541

    authors: Meara SJ,Barker GJ

    更新日期:2005-07-01 00:00:00

  • A highly sensitive lactate editing technique for surface coil spectroscopic imaging in vivo.

    abstract::A lactate editing sequence based on the use of spin-locking pulses with surface coils is described. The sequence retains more than 90% of the available lactate magnetization and suppresses at least 95% of the lipid signal in a single scan and ca. 99.5% after a simple two step cycle. The technique allows simultaneous o...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290320

    authors: Bourgeois D,Kozlowski P

    更新日期:1993-03-01 00:00:00

  • Interactive coronary MRI.

    abstract::The acquisition of complete three-dimensional (3D), segmented gradient-echo data sets to visualize the coronary arteries can be both time consuming and sensitive to motion, even with use of multiple breath-holding or respiratory gating. An alternate hybrid approach is demonstrated here, in which real-time interactive ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910400115

    authors: Hardy CJ,Darrow RD,Pauly JM,Kerr AB,Dumoulin CL,Hu BS,Martin KM

    更新日期:1998-07-01 00:00:00

  • Quantitative framework for prospective motion correction evaluation.

    abstract:PURPOSE:Establishing a framework to evaluate performances of prospective motion correction (PMC) MRI considering motion variability between MRI scans. METHODS:A framework was developed to obtain quantitative comparisons between different motion correction setups, considering that varying intrinsic motion patterns betw...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25580

    authors: Pannetier NA,Stavrinos T,Ng P,Herbst M,Zaitsev M,Young K,Matson G,Schuff N

    更新日期:2016-02-01 00:00:00

  • A new steady-state imaging sequence for simultaneous acquisition of two MR images with clearly different contrasts.

    abstract::We present a new steady-state imaging sequence, which simultaneously allows in a single acquisition the formation of two MR images with clearly different contrasts. The contrast of the first image is FISP-like, whereas the second image is strongly T2-weighted. In principle the T2 values in the image can be calculated ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910070105

    authors: Bruder H,Fischer H,Graumann R,Deimling M

    更新日期:1988-05-01 00:00:00

  • Apparent propagator anisotropy from single-shell diffusion MRI acquisitions.

    abstract:PURPOSE:The apparent propagator anisotropy (APA) is a new diffusion MRI metric that, while drawing on the benefits of the ensemble averaged propagator anisotropy (PA) compared to the fractional anisotropy (FA), can be estimated from single-shell data. THEORY AND METHODS:Computation of the full PA requires acquisition ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28620

    authors: Aja-Fernández S,Tristán-Vega A,Jones DK

    更新日期:2020-12-13 00:00:00

  • Metabolic changes in activated T cells: an NMR study of human peripheral blood lymphocytes.

    abstract::Using NMR spectroscopy, we studied purified, human T lymphocytes in a serum-free medium. Purified cells were entrapped inside agarose beads and induced to proliferate by the mitogens phorbol-12-myristate-13-acetate and ionomycin. T lymphocytes in standard culture and inside agarose beads exhibit comparable viability, ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910290307

    authors: Bental M,Deutsch C

    更新日期:1993-03-01 00:00:00

  • Partial-volume effect on ischemic tissue-fate delineation using quantitative perfusion and diffusion imaging on a rat stroke model.

    abstract::Partial-volume effects (PVE) in stroke imaging could hinder proper delineation of normal, ischemic, and at-risk tissues. Cerebral-blood-flow (CBF) and apparent diffusion coefficient (ADC) were measured at high and low resolution (HR = 128 x 128, LR = 64 x 64) in focal ischemia in rats during the acute phase. The data ...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20299

    authors: Ren H,Shen Q,Bardutzky J,Fisher M,Duong TQ

    更新日期:2004-12-01 00:00:00

  • Deuterium magnetic resonance imaging of rabbit eye in vivo.

    abstract::We used deuterium magnetic resonance imaging (2H MRI) to visualize water movement in the rabbit eye. Dynamic 2H MRI was obtained every 3.5 min at 2 tesla by FLASH pulse sequence (TR, 300 ms; TE, 10 ms; alpha = 90 degrees) with a slice thickness of 10 mm using a surface coil (4 cm in diameter). After topical administra...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330417

    authors: Obata T,Ikehira H,Koga M,Yoshida K,Kimura F,Tateno Y

    更新日期:1995-04-01 00:00:00

  • Indirect 17(O)-magnetic resonance imaging of cerebral blood flow in the rat.

    abstract::Proton T(1rho)-dispersion MRI is demonstrated for indirect, in vivo detection of (17)O in the brain. This technique, which may be readily implemented on any clinical MRI scanner, is applied towards high-resolution, quantitative mapping of cerebral blood flow (CBF) in the rat by monitoring the clearance of (17)O-enrich...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.10403

    authors: Tailor DR,Roy A,Regatte RR,Charagundla SR,McLaughlin AC,Leigh JS,Reddy R

    更新日期:2003-03-01 00:00:00

  • Continuously moving table MRI with golden angle radial sampling.

    abstract:PURPOSE:Continuously moving table (CMT) MRI is a high throughput technique that has multiple applications in whole-body imaging. In this work, CMT MRI based on golden angle (GA, 111.246° azimuthal step) radial sampling is developed at 3 Tesla (T), with the goal of increased flexibility in image reconstruction using arb...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25531

    authors: Sengupta S,Smith DS,Welch EB

    更新日期:2015-12-01 00:00:00

  • Combined T2 -preparation and multidimensional outer volume suppression for coronary artery imaging with 3D cones trajectories.

    abstract:PURPOSE:To develop a modular magnetization preparation sequence for combined T2 -preparation and multidimensional outer volume suppression (OVS) for coronary artery imaging. METHODS:A combined T2 -prepared 1D OVS sequence with fat saturation was defined to contain a 90°-60 180°60 composite nonselective tip-down pulse,...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.28057

    authors: Zeng DY,Baron CA,Malavé MO,Kerr AB,Yang PC,Hu BS,Nishimura DG

    更新日期:2020-06-01 00:00:00

  • Radiofrequency pulse design for the selective excitation of dissolved 129Xe.

    abstract:PURPOSE:To optimize radiofrequency (RF) pulses for the selective excitation of dissolved phase (129)Xe that take into account the very short T2*, while simultaneously, minimally exciting the much larger gas signal. METHODS:Numerical simulations of Shinnar le-Roux pulses and binomial coefficient composite-element pulse...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25089

    authors: Leung G,Norquay G,Schulte RF,Wild JM

    更新日期:2015-01-01 00:00:00

  • Nuclear magnetic resonance parameters for monitoring coagulation of liver tissue.

    abstract::A new NMR parameter is suggested as a sensitive tool for monitoring thermal coagulation of liver tissue. That parameter is the proton magnetization exchange time (tau(MEX)) between water and the proteins. tau(MEX) was very sensitive to coagulation and insensitive to temperature, therefore representing only damage to t...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.20693

    authors: Carasso D,Eliav U,Navon G

    更新日期:2005-11-01 00:00:00

  • T2 measurement in articular cartilage: impact of the fitting method on accuracy and precision at low SNR.

    abstract::T2 relaxation time is a promising MRI parameter for the detection of cartilage degeneration in osteoarthritis. However, the accuracy and precision of the measured T2 may be substantially impaired by the low signal-to-noise ratio of images available from clinical examinations. The purpose of this work was to assess the...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22178

    authors: Raya JG,Dietrich O,Horng A,Weber J,Reiser MF,Glaser C

    更新日期:2010-01-01 00:00:00

  • Pattern recognition analysis of 1H NMR spectra from perchloric acid extracts of human brain tumor biopsies.

    abstract::Pattern recognition techniques (factor analysis and neural networks) were used to investigate and classify human brain tumors based on the 1H NMR spectra of chemically extracted biopsies (n = 118). After removing information from lactate (because of variable ischemia times), unsupervised learning suggested that the sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910390604

    authors: Maxwell RJ,Martínez-Pérez I,Cerdán S,Cabañas ME,Arús C,Moreno A,Capdevila A,Ferrer E,Bartomeus F,Aparicio A,Conesa G,Roda JM,Carceller F,Pascual JM,Howells SL,Mazucco R,Griffiths JR

    更新日期:1998-06-01 00:00:00

  • Separation and quantification of lactate and lipid at 1.3 ppm by diffusion-weighted magnetic resonance spectroscopy.

    abstract:PURPOSE:To separate the spectrally overlapped lactate and lipid signals at 1.3 ppm using diffusion-weighted magnetic resonance spectroscopy (DW-MRS) based on their large diffusivity difference. METHODS:DW-MRS was applied to the gel phantoms containing lactate and lipid droplets, and to the rat brain tumors. Lactate an...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26144

    authors: Wang AM,Leung GK,Kiang KM,Chan D,Cao P,Wu EX

    更新日期:2017-02-01 00:00:00

  • Improved sensitivity to overlapping multiplet signals in in vivo proton spectroscopy using a multiecho volume selective (CPRESS) experiment.

    abstract::A method for volume selective proton spectroscopy is presented based on a multiecho sequence with short refocusing interval tcp. It is demonstrated, that by appropriate choice of tcp on the order of 4-6 ms, signals from overlapping multiplets like the glutamine and glutamate (Glu/Gln) resonances in spectra of the huma...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910370603

    authors: Hennig J,Thiel T,Speck O

    更新日期:1997-06-01 00:00:00

  • Slow magic-angle coil spinning: a high-sensitivity and high-resolution NMR strategy for microscopic biological specimens.

    abstract::High-resolution magic-angle spinning has become a valuable tool to study biologic samples; however, there are only a few high-resolution magic-angle spinning methodologies that have been explored specifically to deal with small semisolid biomaterials such as tissues. Here, we report a novel high-resolution (1)H NMR sp...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.22231

    authors: Wong A,Aguiar PM,Sakellariou D

    更新日期:2010-02-01 00:00:00

  • Echo-time reduction for submillimeter resolution imaging with a 3D phase encode time reduced acquisition method.

    abstract::To achieve optimal image quality and highest spatial resolution for inner ear imaging with a 3D gradient echo sequence, it is necessary to minimize susceptibility dephasing effects by using very short TE. Fractional RF pulses and echoes can yield short TE for moderate spatial resolution; however, for voxel size of les...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330112

    authors: Ying K,Schmalbrock P,Clymer B

    更新日期:1995-01-01 00:00:00

  • Self-navigated 4D cartesian imaging of periodic motion in the body trunk using partial k-space compressed sensing.

    abstract:PURPOSE:To enable fast and flexible high-resolution four-dimensional (4D) MRI of periodic thoracic/abdominal motion for motion visualization or motion-corrected imaging. METHODS:We proposed a Cartesian three-dimensional k-space sampling scheme that acquires a random combination of k-space lines in the ky/kz plane. A p...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.26406

    authors: Küstner T,Würslin C,Schwartz M,Martirosian P,Gatidis S,Brendle C,Seith F,Schick F,Schwenzer NF,Yang B,Schmidt H

    更新日期:2017-08-01 00:00:00

  • In vivo dynamic MRI tracking of rat T-cells labeled with superparamagnetic iron-oxide particles.

    abstract::Dynamic MRI tracking of rat T-cells in vivo is performed in rat testicles after labeling isolated rat T-cells in vitro with superparamagnetic dextran-coated iron-oxide particles, BMS180549. Tissue inflammation induced by the local injection of the calcium ionophore, A23187, is used to attract labeled T-cells. Gradient...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910330209

    authors: Yeh TC,Zhang W,Ildstad ST,Ho C

    更新日期:1995-02-01 00:00:00

  • Assessing transneuronal dysfunction utilizing manganese-enhanced MRI (MEMRI).

    abstract::In this study we utilized manganese-enhanced MRI (MEMRI) to evaluate the in vivo transneuronal efficiency of manganese ion (Mn(2+)) movement as a means to assess overall changes in neuronal function. We designated this extension the manganese transfer index (MTI) value. To evaluate the MTI value as an index of transne...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.21648

    authors: Serrano F,Deshazer M,Smith KD,Ananta JS,Wilson LJ,Pautler RG

    更新日期:2008-07-01 00:00:00

  • Simple measurement of scanner stability for functional NMR imaging of activation in the brain.

    abstract::Functional MR imaging (fMRI) of activation in the brain is one of the more demanding applications required of an NMR imaging instrument. Since the signal changes in activation imaging are quite small, any instrumental variations can easily compromise the fMRI contrast. The authors describe a simple method for measurin...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.1910360422

    authors: Weisskoff RM

    更新日期:1996-10-01 00:00:00

  • Characterizing the limits of MRI near metallic prostheses.

    abstract:PURPOSE:To characterize the fundamental limits of MRI near metallic implants on RF excitation, frequency encoding, and chemical shift-encoding water-fat separation. METHODS:Multicomponent three-dimensional (3D) digital models of a total hip and a total knee replacement were used to construct material-specific suscepti...

    journal_title:Magnetic resonance in medicine

    pub_type: 杂志文章

    doi:10.1002/mrm.25540

    authors: Smith MR,Artz NS,Wiens C,Hernando D,Reeder SB

    更新日期:2015-12-01 00:00:00