Myocardial T1 mapping using SMART1 Map and MOLLI mapping in asymptomatic patients with recent extracardiac sarcoidosis.

Abstract:

INTRODUCTION:Sarcoidosis is a systemic granulomatous disease affecting in particular the respiratory tract. Cardiac magnetic resonance (CMR), including a measurement of T1 relaxation time, could potentially detect early stadia of sarcoidosis of the heart. The study aims to assess T1 mapping in the detection of early cardiac involvement in asymptomatic patients with sarcoidosis. METHODS:One hundred and twenty patients with extracardiac sarcoidosis and without any heart disease history were included. One hundred and thirteen of them underwent a CMR examination. The mean time from the diagnosis of sarcoidosis was 0.8 (0.2-3.3) years. Cine images for the assessment of left ventricular (LV) functional parameters and pre- and post-contrast saturation method using adaptive recovery times for cardiac T1 mapping (SMART1 Map) and modified Look-Locker inversion recovery (MOLLI) images were acquired for the assessment of native T1 relaxation time and extracellular volume (ECV). The measured parameters were compared between sarcoidosis patients and 22 controls. RESULTS:The sarcoidosis patients had normal global and regional systolic LV function-LV ejection fraction 65 ± 5% versus 66 ± 7% (p NS). The mean native T1 relaxation times were not prolonged-1465 ± 93 ms versus 1480 ± 88 ms (p NS) measured by SMART1 Map and 1317 ± 60 ms versus 1313 ± 83 ms (p NS) measured using a MOLLI sequence. Similarly, the mean ECV values did not increase-16.9 ± 3.9% versus 17.9 ± 3.7% (p NS) measured by SMART1 Map and 30.9 ± 2.9% versus 31.6 ± 8.3% (p NS) measured using a MOLLI sequence. CONCLUSION:Myocardial native T1 relaxation times were not prolonged and ECV was not increased in asymptomatic patients with extracardiac sarcoidosis.

journal_name

NMR Biomed

journal_title

NMR in biomedicine

authors

Panovský R,Doubková M,Holeček T,Máchal J,Feitová V,Masárová L,Opatřil L,Mojica-Pisciotti ML,Kincl V

doi

10.1002/nbm.4388

subject

Has Abstract

pub_date

2020-11-01 00:00:00

pages

e4388

issue

11

eissn

0952-3480

issn

1099-1492

journal_volume

33

pub_type

杂志文章
  • A system for automated noise parameter measurements on MR preamplifiers and application to high B(0) fields.

    abstract::A noise figure and noise parameter measurement system was developed that consists of a combination spectrum and network analyzer, preamplifier, programmable power supply, noise source, tuning board, and desktop computer. The system uses the Y-factor method for noise figure calculation and allows calibrations to correc...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3138

    authors: Lagore RL,Roberts BR,Possanzini C,Saylor C,Fallone BG,De Zanche N

    更新日期:2014-08-01 00:00:00

  • Absolute quantification of metabolites in breast cancer cell extracts by quantitative 2D (1) H INADEQUATE NMR.

    abstract::Metabolomic studies by NMR spectroscopy are increasingly employed for a variety of biomedical applications. A very standardized 1D proton NMR protocol is generally employed for data acquisition, associated with multivariate statistical tests. Even if targeted approaches have been proposed to quantify metabolites from ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1816

    authors: Martineau E,Tea I,Akoka S,Giraudeau P

    更新日期:2012-08-01 00:00:00

  • The combined measurement of blood flow and metabolism in RIF-1 tumours in vivo. A study using H2 flow and 31P NMR spectroscopy.

    abstract::Blood flow and phosphorus metabolites have been measured simultaneously in the murine RIF-1 tumour in vivo. Blood flow was measured using the H2 washout technique and 31P NMR spectroscopy was used to measure high energy phosphates, inorganic phosphate and intracellular pH within the tumour. Following NMR and flow meas...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1940030406

    authors: Bhujwalla ZM,Tozer GM,Field SB,Proctor E,Busza A,Williams SR

    更新日期:1990-08-01 00:00:00

  • Image-based tissue engineering of a total intervertebral disc implant for restoration of function to the rat lumbar spine.

    abstract::Nonbiological total disc replacement is currently being used for the treatment of intervertebral disc (IVD) disease and injury, but these implants are prone to mechanical wear, tear and possible dislodgement. Recently, tissue-engineered total disc replacement (TE-TDR) has been investigated as a possible alternative to...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1651

    authors: Bowles RD,Gebhard HH,Dyke JP,Ballon DJ,Tomasino A,Cunningham ME,Härtl R,Bonassar LJ

    更新日期:2012-03-01 00:00:00

  • Short- and long-term reproducibility of BOLD signal change induced by breath-holding at 1.5 and 3 T.

    abstract::Cerebrovascular reactivity (CVR) can give insight into the cerebrovascular function. CVR can be estimated by measuring a blood-oxygen-level-dependent (BOLD) response combined with breath-holding (BH). The reproducibility of this technique has been addressed and existing studies have focused on short-term reproducibili...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4195

    authors: Peng SL,Yang HC,Chen CM,Shih CT

    更新日期:2020-03-01 00:00:00

  • In vivo brain viscoelastic properties measured by magnetic resonance elastography.

    abstract::Magnetic resonance elastography (MRE) is a non-invasive imaging technique used to visualise and quantify mechanical properties of tissue, providing information beyond what can be currently achieved with standard MR sequences and could, for instance, provide new insight into pathological processes in the brain. This st...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1254

    authors: Green MA,Bilston LE,Sinkus R

    更新日期:2008-08-01 00:00:00

  • 31P NMR studies of human skin using a modified zig-zag surface coil.

    abstract::Results are presented from an in vivo study of human skin in which a zig-zag surface coil together with a three-pulse Fourier Series Window (FSW) protocol have been used to obtain minimally contaminated 31P skin spectra of the posterior calf. Phantom experiments indicate that while the fall-off in the B1 field profile...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/(SICI)1099-1492(199608)9:5<195::AID-NBM416

    authors: Cowie AG,Bastin ME,Manners DN,Hands LJ,Styles P,Radda GK

    更新日期:1996-08-01 00:00:00

  • Detection of endogenous iron deposits in the injured mouse spinal cord through high-resolution ex vivo and in vivo MRI.

    abstract::The main aim of this study was to employ high-resolution MRI to investigate the spatiotemporal development of pathological features associated with contusive spinal cord injury (SCI) in mice. Experimental mice were subjected to either sham surgery or moderate contusive SCI. A 16.4-T small-animal MR system was employed...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2829

    authors: Blomster LV,Cowin GJ,Kurniawan ND,Ruitenberg MJ

    更新日期:2013-02-01 00:00:00

  • Effect of ethanol on hepatic energy metabolism and intracellular pH in chronically ethanol-treated rats. A 31P NMR study of normoxic or hypoxic perfused liver.

    abstract::31P Nuclear magnetic resonance spectroscopy has been used to investigate the combined effect of 70 mM ethanol administration and hypoxia on the energetic metabolism and cytosolic pH of the perfused liver isolated from naive, fasted or chronically ethanol-treated rats. Ethanol-treatment or fasting induce a similar 25% ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1940030306

    authors: Desmoulin F,Canioni P,Masson S,Gérolami A,Cozzone PJ

    更新日期:1990-06-01 00:00:00

  • Reproducibility and effect of tissue composition on cerebellar γ-aminobutyric acid (GABA) MRS in an elderly population.

    abstract::MRS provides a valuable tool for the non-invasive detection of brain γ-aminobutyric acid (GABA) in vivo. GABAergic dysfunction has been observed in the aging cerebellum. The study of cerebellar GABA changes is of considerable interest in understanding certain age-related motor disorders. However, little is known about...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3381

    authors: Long Z,Dyke JP,Ma R,Huang CC,Louis ED,Dydak U

    更新日期:2015-10-01 00:00:00

  • Measurement of creatine kinase reaction rate in human brain using magnetization transfer image-selected in vivo spectroscopy (MT-ISIS) and a volume ³¹P/¹H radiofrequency coil in a clinical 3-T MRI system.

    abstract::High-energy phosphate metabolism, which allows the synthesis and regeneration of adenosine triphosphate (ATP), is a vital process for neuronal survival and activity. In particular, creatine kinase (CK) serves as an energy reservoir for the rapid buffering of ATP levels. Altered CK enzyme activity, reflecting compromis...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1636

    authors: Jeong EK,Sung YH,Kim SE,Zuo C,Shi X,Mellon EA,Renshaw PF

    更新日期:2011-08-01 00:00:00

  • Continuous noninvasive monitoring of transcutaneous blood gases for a stable and persistent BOLD contrast in fMRI studies in the rat.

    abstract::The physiological status of anesthetized rats greatly influences blood oxygenation level dependent (BOLD) functional magnetic resonance imaging (fMRI). Monitoring of physiological parameters, particularly partial pressure of carbon dioxide (pCO(2)) levels in the blood, is therefore an important part in the design and ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.978

    authors: Ramos-Cabrer P,Weber R,Wiedermann D,Hoehn M

    更新日期:2005-11-01 00:00:00

  • MRI of lung parenchyma in rats and mice using a gradient-echo sequence.

    abstract::Signal of lung parenchymal tissue from the living rat and mouse lung was detected at 4.7 T with a good signal-to-noise ratio and motion-suppressed artifacts using a short TE gradient-echo sequence. Neither cardiac nor respiratory gating were applied, and animals respired freely during data collection. Mean T(2)* relax...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.706

    authors: Beckmann N,Tigani B,Mazzoni L,Fozard JR

    更新日期:2001-08-01 00:00:00

  • Quantitation of proton NMR spectra of the human brain using tissue water as an internal concentration reference.

    abstract::The use of cerebral water as an internal intensity standard for the quantitation of spatially localized proton spectra of the human brain is investigated. The method is validated on standard samples of N-acetyl aspartate (NAA) and lactate, and possible sources of error are discussed. Using the STEAM pulse sequence, co...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1940060114

    authors: Barker PB,Soher BJ,Blackband SJ,Chatham JC,Mathews VP,Bryan RN

    更新日期:1993-01-01 00:00:00

  • Regional neurochemical profiles in the human brain measured by ¹H MRS at 7 T using local B₁ shimming.

    abstract::Increased sensitivity and chemical shift dispersion at ultra-high magnetic fields enable the precise quantification of an extended range of brain metabolites from (1)H MRS. However, all previous neurochemical profiling studies using single-voxel MRS at 7 T have been limited to data acquired from the occipital lobe wit...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1727

    authors: Emir UE,Auerbach EJ,Van De Moortele PF,Marjańska M,Uğurbil K,Terpstra M,Tkáč I,Oz G

    更新日期:2012-01-01 00:00:00

  • In vivo assessment of free magnesium concentration in human brain by 31P MRS. A new calibration curve based on a mathematical algorithm.

    abstract::Free cytosolic [Mg2+] can be assessed in vivo by 31P MRS from the chemical shift of beta-ATP which in turn depends on the fraction of total ATP complexed to Mg2+ ions. The reliability of these in vivo measurements depends on the availability of an appropriate in vitro calibration to determine the limits of chemical sh...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/(SICI)1099-1492(199602)9:1<24::AID-NBM392>

    authors: Iotti S,Frassineti C,Alderighi L,Sabatini A,Vacca A,Barbiroli B

    更新日期:1996-02-01 00:00:00

  • NMR spectroscopy of aminoacylase 1 deficiency, a novel inborn error of metabolism.

    abstract::Aminoacylase 1 deficiency is a novel inborn error of metabolism. The clinical significance of the deficiency is under discussion, as well as the possible consequences of the defect for brain metabolism and function. This study includes the five originally published cases as well as three novel ones. NMR spectroscopy o...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1170

    authors: Engelke UF,Sass JO,Van Coster RN,Gerlo E,Olbrich H,Krywawych S,Calvin J,Hart C,Omran H,Wevers RA

    更新日期:2008-02-01 00:00:00

  • 1 H NMRS of carnosine combined with 31 P NMRS to better characterize skeletal muscle pH dysregulation in Duchenne muscular dystrophy.

    abstract::In recent years, quantitative nuclear magnetic resonance imaging and spectroscopy (NMRI and NMRS) have been used more systematically as outcome measures in natural history and clinical trial studies for Duchenne muscular dystrophy (DMD). Whereas most of these studies have emphasized the evaluation of the fat fraction ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3839

    authors: Reyngoudt H,Turk S,Carlier PG

    更新日期:2018-01-01 00:00:00

  • Contrast-enhanced MRI of murine myocardial infarction - part II.

    abstract::Mouse models are increasingly used to study the pathophysiology of myocardial infarction in vivo. In this area, MRI has become the gold standard imaging modality, because it combines high spatial and temporal resolution functional imaging with a large variety of methods to generate soft tissue contrast. In addition, (...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.2767

    authors: Coolen BF,Paulis LE,Geelen T,Nicolay K,Strijkers GJ

    更新日期:2012-08-01 00:00:00

  • Reproducibility of quantitative dynamic MRI of normal human tissues.

    abstract::The aim of the study was to establish the normal range and to evaluate the reproducibility of dynamic contrast enhanced MRI (DCE-MRI) parameter estimates in normal human pelvic tissues. Nineteen patients with prostate cancer, undergoing androgen deprivation treatment, had paired DCE-MRI examinations of the pelvis usin...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.732

    authors: Padhani AR,Hayes C,Landau S,Leach MO

    更新日期:2002-04-01 00:00:00

  • Correlation of Choline/Creatine and Apparent Diffusion Coefficient values with the prognostic parameters of Head and Neck Squamous Cell Carcinoma.

    abstract::The aim of this study was to measure choline/creatine (Ch/Cr) levels through (1)H-MRS and apparent diffusion coefficient (ADC) values through diffusion-weighted MRI, and to correlate these values with the prognostic parameters of head and neck squamous cell carcinoma (HNSCC). The institutional review board approved th...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3472

    authors: Razek AA,Nada N

    更新日期:2016-04-01 00:00:00

  • Improvement of resolution for brain coupled metabolites by optimized (1)H MRS at 7T.

    abstract::Resolution enhancement for glutamate (Glu), glutamine (Gln) and glutathione (GSH) in the human brain by TE-optimized point-resolved spectroscopy (PRESS) at 7 T is reported. Sub-TE dependences of the multiplets of Glu, Gln, GSH, γ-aminobutyric acid (GABA) and N-acetylaspartate (NAA) at 2.2-2.6 ppm were investigated wit...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1529

    authors: Choi C,Dimitrov IE,Douglas D,Patel A,Kaiser LG,Amezcua CA,Maher EA

    更新日期:2010-11-01 00:00:00

  • Short-echo spectroscopic imaging combined with lactate editing in a single scan.

    abstract::A short-echo spectroscopic imaging sequence extended with a frequency-selective multiple-quantum- coherence technique (Sel-MQC) is presented. The method enables acquisition of a complete water-suppressed proton spectrum with a short echo time and filtering of the J-coupling metabolite, lactate, from co-resonant lipids...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1284

    authors: Melkus G,Mörchel P,Behr VC,Kotas M,Flentje M,Jakob PM

    更新日期:2008-11-01 00:00:00

  • 31P NMR of mammalian cells encapsulated in alginate gels utilizing a new phosphate-free perfusion medium.

    abstract::A simple technique permitting long term 31P magnetic resonance spectroscopy of cultured mammalian cells is described. Cells are encapsulated in calcium alginate gels and perfused with a new phosphate-fre medium designed for maintenance of high cell viability. Intracellular pH and beta-NTP/Pi ratios, studied in three c...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1940030104

    authors: Narayan KS,Moress EA,Chatham JC,Barker PB

    更新日期:1990-02-01 00:00:00

  • Inferring microstructural features and the physiological state of tissues from diffusion-weighted images.

    abstract::We review several methods that have been developed to infer microstructural and physiological information about isotropic and anisotropic tissues from diffusion weighted images (DWIs). These include Diffusion Imaging (DI), Diffusion Tensor Imaging (DTI), isotropically weighted imaging, and q-space imaging. Just as DI ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.1940080707

    authors: Basser PJ

    更新日期:1995-11-01 00:00:00

  • 4D MRI of polycystic kidneys from rapamycin-treated Glis3-deficient mice.

    abstract::Polycystic kidney disease (PKD) is a life-threatening disease that leads to a grotesque enlargement of the kidney and significant loss of function. Several imaging studies with MRI have demonstrated that cyst size in polycystic kidneys can determine disease severity and progression. In the present study, we found that...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3281

    authors: Xie L,Qi Y,Subashi E,Liao G,Miller-DeGraff L,Jetten AM,Johnson GA

    更新日期:2015-05-01 00:00:00

  • Lipid profiling of cancerous and benign gallbladder tissues by 1H NMR spectroscopy.

    abstract::Qualitative and quantitative (1) H NMR analysis of lipid extracts of gallbladder tissue in chronic cholecystitis (CC, benign) (n = 14), xanthogranulomatous cholecystitis (XGC, intermediate) (n = 9) and gallbladder cancer (GBC, malignant) (n = 8) was carried out to understand the mechanisms involved in the transformati...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1594

    authors: Jayalakshmi K,Sonkar K,Behari A,Kapoor VK,Sinha N

    更新日期:2011-05-01 00:00:00

  • Knee MRI under varying flexion angles utilizing a flexible flat cable antenna.

    abstract::The aim of this study is to fabricate and test a novel flexible flat cable antenna (FFCA) for MRI of the knee at different flexion angles. The FFCA was made of a flat cable, a tuning/matching circuit and a signal transmission line. To test its feasibility and validity, in vitro and in vivo experiments were carried out...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3264

    authors: Jia F,Yuan H,Zhou D,Zhang J,Wang X,Fang J

    更新日期:2015-04-01 00:00:00

  • Comparison of RF body coils for MRI at 3  T: a simulation study using parallel transmission on various anatomical targets.

    abstract::The performance of multichannel transmit coil layouts and parallel transmission (pTx) RF pulse design was evaluated with respect to transmit B1 (B1 (+)) homogeneity and specific absorption rate (SAR) at 3 T for a whole body coil. Five specific coils were modeled and compared: a 32-rung birdcage body coil (driven eithe...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3378

    authors: Wu X,Zhang X,Tian J,Schmitter S,Hanna B,Strupp J,Pfeuffer J,Hamm M,Wang D,Nistler J,He B,Vaughan TJ,Ugurbil K,Van de Moortele PF

    更新日期:2015-10-01 00:00:00

  • Cardiac lipid levels show diurnal changes and long-term variations in healthy human subjects.

    abstract::(1) H-MRS is regularly applied to determine lipid content in ectopic tissue - mostly skeletal muscle and liver - to investigate physiological and/or pathologic conditions, e.g. insulin resistance. Technical developments also allow non-invasive in vivo assessment of cardiac lipids; however, basic data about methodologi...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3186

    authors: Ith M,Stettler C,Xu J,Boesch C,Kreis R

    更新日期:2014-11-01 00:00:00