Scanning electron microscopy of chronically implanted intracortical microelectrode arrays in non-human primates.

Abstract:

OBJECTIVE:Signal attenuation is a major problem facing intracortical sensors for chronic neuroprosthetic applications. Many studies suggest that failure is due to gliosis around the electrode tips, however, mechanical and material causes of failure are often overlooked. The purpose of this study was to investigate the factors contributing to progressive signal decline by using scanning electron microscopy (SEM) to visualize structural changes in chronically implanted arrays and histology to examine the tissue response at corresponding implant sites. APPROACH:We examined eight chronically implanted intracortical microelectrode arrays (MEAs) explanted from non-human primates at times ranging from 37 to 1051 days post-implant. We used SEM, in vivo neural recordings, and histology (GFAP, Iba-1, NeuN). Three MEAs that were never implanted were also imaged as controls. MAIN RESULTS:SEM revealed progressive corrosion of the platinum electrode tips and changes to the underlying silicon. The parylene insulation was prone to cracking and delamination, and in some instances the silicone elastomer also delaminated from the edges of the MEA. Substantial tissue encapsulation was observed and was often seen growing into defects in the platinum and parylene. These material defects became more common as the time in vivo increased. Histology at 37 and 1051 days post-implant showed gliosis, disruption of normal cortical architecture with minimal neuronal loss, and high Iba-1 reactivity, especially within the arachnoid and dura. Electrode tracts were either absent or barely visible in the cortex at 1051 days, but were seen in the fibrotic encapsulation material suggesting that the MEAs were lifted out of the brain. Neural recordings showed a progressive drop in impedance, signal amplitude, and viable channels over time. SIGNIFICANCE:These results provide evidence that signal loss in MEAs is truly multifactorial. Gliosis occurs in the first few months after implantation but does not prevent useful recordings for several years. Progressive meningeal fibrosis encapsulates and lifts MEAs out of the cortex while ongoing foreign body reactions lead to progressive degradation of the materials. Long-term impedance drops are due to the corrosion of platinum, cracking and delamination of parylene, and delamination of silicone elastomer. Oxygen radicals released by cells of the immune system likely mediate the degradation of these materials. Future MEA designs must address these problems through more durable insulation materials, more inert electrode alloys, and pharmacologic suppression of fibroblasts and leukocytes.

journal_name

J Neural Eng

authors

Barrese JC,Aceros J,Donoghue JP

doi

10.1088/1741-2560/13/2/026003

subject

Has Abstract

pub_date

2016-04-01 00:00:00

pages

026003

issue

2

eissn

1741-2560

issn

1741-2552

journal_volume

13

pub_type

杂志文章
  • Corrigendum: Tissue-engineered nerve grafts using a scaffold-independent and injectable drug delivery system: a novel design with translational advantages (2019 J. Neural Eng. 16 036030).

    abstract:OBJECTIVE:Currently commercially available nerve conduits have demonstrated suboptimal clinical efficacy in repairing peripheral nerve defects. Although tissue-engineered nerve grafts (TENGs) with sustained release of neurotrophic factors (NTFs) are experimentally proved to be more effective than these blank conduits, ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd1ec

    authors: Liu Y,Yu S,Gu X,Cao R,Cui S

    更新日期:2020-12-09 00:00:00

  • Machine learning validation of EEG+tACS artefact removal.

    abstract:OBJECTIVE:Electroencephalography (EEG) recorded during transcranial alternating current simulation (tACS) is highly desirable in order to investigate brain dynamics during stimulation, but is corrupted by large amplitude stimulation artefacts. Artefact removal algorithms have been presented previously, but with substan...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab58a3

    authors: Kohli S,Casson AJ

    更新日期:2020-01-24 00:00:00

  • Human-inspired sound environment recognition system for assistive vehicles.

    abstract:OBJECTIVE:The human auditory system acquires environmental information under sound stimuli faster than visual or touch systems, which in turn, allows for faster human responses to such stimuli. It also complements senses such as sight, where direct line-of-view is necessary to identify objects, in the environment recog...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/1/016012

    authors: Vidal EG,Zarricueta EF,Cheein FA

    更新日期:2015-02-01 00:00:00

  • The statistical distribution of noisy transmission in human sensors.

    abstract:OBJECTIVE:Brains, like other physical devices, are inherently noisy. This source of variability is large, to the extent that internal noise often impacts human sensory processing more than externally induced (stimulus-driven) perturbations. Despite the fundamental nature of this phenomenon, its statistical distribution...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/1741-2560/10/1/016014

    authors: Neri P

    更新日期:2013-02-01 00:00:00

  • Neural engineering: the process, applications, and its role in the future of medicine.

    abstract:OBJECTIVE:Recent advances in neural engineering have restored mobility to people with paralysis, relieved symptoms of movement disorders, reduced chronic pain, restored the sense of hearing, and provided sensory perception to individuals with sensory deficits. APPROACH:This progress was enabled by the team-based, inte...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2552/ab4869

    authors: Ereifej ES,Shell CE,Schofield JS,Charkhkar H,Cuberovic I,Dorval AD,Graczyk EL,Kozai TDY,Otto KJ,Tyler DJ,Welle CG,Widge AS,Zariffa J,Moritz CT,Bourbeau DJ,Marasco PD

    更新日期:2019-11-12 00:00:00

  • Characterization of evoked tactile sensation in forearm amputees with transcutaneous electrical nerve stimulation.

    abstract:OBJECTIVE:The goal of this study is to characterize the phenomenon of evoked tactile sensation (ETS) on the stump skin of forearm amputees using transcutaneous electrical nerve stimulation (TENS). APPROACH:We identified the projected finger map (PFM) of ETS on the stump skin in 11 forearm amputees, and compared percep...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/6/066002

    authors: Chai G,Sui X,Li S,He L,Lan N

    更新日期:2015-12-01 00:00:00

  • Probabilistic co-adaptive brain-computer interfacing.

    abstract:OBJECTIVE:Brain-computer interfaces (BCIs) are confronted with two fundamental challenges: (a) the uncertainty associated with decoding noisy brain signals, and (b) the need for co-adaptation between the brain and the interface so as to cooperatively achieve a common goal in a task. We seek to mitigate these challenges...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/6/066008

    authors: Bryan MJ,Martin SA,Cheung W,Rao RP

    更新日期:2013-12-01 00:00:00

  • Consistency of quantitative electroencephalography features in a large clinical data set.

    abstract:OBJECTIVE:Despite their increasing use and public health importance, little is known about the consistency and variability of the quantitative features of baseline electroencephalography (EEG) measurements in healthy individuals and populations. This study aims to investigate population consistency of EEG features. AP...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab4af3

    authors: Nahmias DO,Kontson KL,Soltysik DA,Civillico EF

    更新日期:2019-11-12 00:00:00

  • CO2 sensitivity of the complexity of phrenic neurograms in the piglet during early maturation.

    abstract::In this paper, we investigate the influence of hypercapnia on the dynamics of the phrenic neurogram in the piglet in two different age groups: 3-7 days (n = 11) and 10-16 days (n = 9). The phrenic neurogram was recorded from 17 piglets (3-16 days old) during control (40% O(2) with 3-5% end-tidal CO(2)), mild hypercapn...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/2/2/004

    authors: Akay M

    更新日期:2005-06-01 00:00:00

  • Simulation of the effect of Na+ and Cl- on the velocity of a spreading depression wave using a simplified electrochemical model of synaptic terminals.

    abstract::In the study of the spreading depression (SD) wave phenomenon and its dynamics, it is necessary to describe the ionic movements along the extracellular space, as well as between this and the intracellular space. In both cases, the ionic movement includes a double coupling involving the concentration and the potential ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/1/2/007

    authors: Teixeira HZ,de Almeida AC,Infantosi AF,Vasconcelos MA,Duarte MA

    更新日期:2004-06-01 00:00:00

  • Inhibition of neuronal cell-cell adhesion measured by the microscopic aggregation assay and impedance sensing.

    abstract::Microscopic aggregation assay and impedance sensing (IS) were used to monitor a change in in vitro neuron-neuron adhesion in response to blocking of cell adhesion molecules. By blocking neuron-neuron adhesion, migration and aggregation of neuronal cells can be inhibited. This leads to better control of spatial arrange...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/7/5/056003

    authors: Wiertz RW,Marani E,Rutten WL

    更新日期:2010-10-01 00:00:00

  • A novel training-free recognition method for SSVEP-based BCIs using dynamic window strategy.

    abstract:OBJECTIVE:Filter bank canonical correlation analysis (FBCCA) is a widely-used classification approach implemented in steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs). However, conventional detection algorithms for SSVEP recognition problems, including the FBCCA, were usually based on ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab914e

    authors: Chen Y,Yang C,Chen X,Wang Y,Gao X

    更新日期:2020-05-07 00:00:00

  • Toward the development of a color visual prosthesis.

    abstract::All of the human prosthetic visual systems implanted so far have been achromatic. Schmidt et al. (1996) reported that at low stimulation intensities their subject reported that phosphenes usually had a specific hue, but when the stimulus intensity was increased, they desaturated to white. We speculate here that previo...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd520

    authors: Towle V,Pham T,McCaffrey M,Allen D,Troyk PR

    更新日期:2020-12-18 00:00:00

  • Symbolic time series analysis of fNIRS signals in brain development assessment.

    abstract:OBJECTIVE:Assessing an infant's brain development remains a challenge for neuroscientists and pediatricians despite great technological advances. As a non-invasive neuroimaging tool, functional near-infrared spectroscopy (fNIRS) has great advantages in monitoring an infant's brain activity. To explore the dynamic featu...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aae0c9

    authors: Liang Z,Minagawa Y,Yang HC,Tian H,Cheng L,Arimitsu T,Takahashi T,Tong Y

    更新日期:2018-12-01 00:00:00

  • Applying dynamic data collection to improve dry electrode system performance for a P300-based brain-computer interface.

    abstract:OBJECTIVE:Dry electrodes have an advantage over gel-based 'wet' electrodes by providing quicker set-up time for electroencephalography recording; however, the potentially poorer contact can result in noisier recordings. We examine the impact that this may have on brain-computer interface communication and potential app...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/6/066018

    authors: Clements JM,Sellers EW,Ryan DB,Caves K,Collins LM,Throckmorton CS

    更新日期:2016-12-01 00:00:00

  • Coarse behavioral context decoding.

    abstract:OBJECTIVE:Current brain-computer interface (BCI) studies demonstrate the potential to decode neural signals obtained from structured and trial-based tasks to drive actuators with high performance within the context of these tasks. Ideally, to maximize utility, such systems will be applied to a wide range of behavioral ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaee9c

    authors: Alasfour A,Gabriel P,Jiang X,Shamie I,Melloni L,Thesen T,Dugan P,Friedman D,Doyle W,Devinsky O,Gonda D,Sattar S,Wang S,Halgren E,Gilja V

    更新日期:2019-02-01 00:00:00

  • Pattern separation and completion of distinct axonal inputs transmitted via micro-tunnels between co-cultured hippocampal dentate, CA3, CA1 and entorhinal cortex networks.

    abstract:OBJECTIVE:Functions ascribed to the hippocampal sub-regions for encoding episodic memories include the separation of activity patterns propagated from the entorhinal cortex (EC) into the dentate gyrus (DG) and pattern completion in CA3 region. Since a direct assessment of these functions is lacking at the level of spec...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aabc20

    authors: Poli D,Wheeler BC,DeMarse TB,Brewer GJ

    更新日期:2018-08-01 00:00:00

  • Decoding natural reach-and-grasp actions from human EEG.

    abstract:OBJECTIVE:Despite the high number of degrees of freedom of the human hand, most actions of daily life can be executed incorporating only palmar, pincer and lateral grasp. In this study we attempt to discriminate these three different executed reach-and-grasp actions utilizing their EEG neural correlates. APPROACH:In a...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa8911

    authors: Schwarz A,Ofner P,Pereira J,Sburlea AI,Müller-Putz GR

    更新日期:2018-02-01 00:00:00

  • Influence of field of view in visual prostheses design: Analysis with a VR system.

    abstract:OBJECTIVE:Visual prostheses are designed to restore partial functional vision in patients with total vision loss. Retinal visual prostheses provide limited capabilities as a result of low resolution, limited field of view and poor dynamic range. Understanding the influence of these parameters in the perception results ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abb9be

    authors: Sanchez-Garcia M,Martinez-Cantin R,Bermudez-Cameo J,Guerrero JJ

    更新日期:2020-10-08 00:00:00

  • Improving an open-source commercial system to reliably perform activity-dependent stimulation.

    abstract:OBJECTIVE:Activity-dependent stimulation (ADS) is designed to strengthen the connections between neuronal circuits and therefore may be a promising tool for promoting neurophysiological reorganization following a brain injury. To successfully perform this technique, two criteria must be met: (1) spikes in the extracell...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab3319

    authors: Murphy M,Buccelli S,Bornat Y,Bundy D,Nudo R,Guggenmos D,Chiappalone M

    更新日期:2019-10-29 00:00:00

  • In vitro and in vivo stability of black-platinum coatings on flexible, polymer microECoG arrays.

    abstract:OBJECTIVE:Intracranial EEG (iEEG) or micro-electrocorticography (µECoG) microelectrodes offer high spatial resolution in recordings of neuronal activity from the exposed brain surface. Reliability of dielectric substrates and conductive materials of these devices are under intensive research in terms of functional stab...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aacf71

    authors: Zátonyi A,Fedor F,Borhegyi Z,Fekete Z

    更新日期:2018-10-01 00:00:00

  • A robust two-stage sleep spindle detection approach using single-channel EEG.

    abstract:OBJECTIVE:Sleep spindles in the electroencephalogram (EEG) are significant in sleep analysis related to cognitive functions and neurological diseases, and thus are of great clinical interests. An automatic sleep spindle detection algorithm could help decrease the workload of visual inspection by sleep clinicians. APPR...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd463

    authors: Jiang D,Ma Y,Wang Y

    更新日期:2020-12-16 00:00:00

  • Force estimation from ensembles of Golgi tendon organs.

    abstract::Golgi tendon organs (GTOs) located in the skeletal muscles provide the central nervous system with information about muscle tension. The ensemble firing of all GTO receptors in the muscle has been hypothesized to represent a reliable measure of the whole muscle force but the precision and accuracy of that information ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/6/3/036001

    authors: Mileusnic MP,Loeb GE

    更新日期:2009-06-01 00:00:00

  • EEG classification of imagined syllable rhythm using Hilbert spectrum methods.

    abstract::We conducted an experiment to determine whether the rhythm with which imagined syllables are produced may be decoded from EEG recordings. High density EEG data were recorded for seven subjects while they produced in imagination one of two syllables in one of three different rhythms. We used a modified second-order bli...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/7/4/046006

    authors: Deng S,Srinivasan R,Lappas T,D'Zmura M

    更新日期:2010-08-01 00:00:00

  • Understanding ultrasound neuromodulation using a computationally efficient and interpretable model of intramembrane cavitation.

    abstract:OBJECTIVE:Low-intensity focused ultrasound stimulation (LIFUS) emerges as an attracting technology for noninvasive modulation of neural circuits, yet the underlying action mechanisms remain unclear. The neuronal intramembrane cavitation excitation (NICE) model suggests that LIFUS excites neurons through a complex inter...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab1685

    authors: Lemaire T,Neufeld E,Kuster N,Micera S

    更新日期:2019-08-01 00:00:00

  • Evaluation of windowing techniques for intramuscular EMG-based diagnostic, rehabilitative and assistive devices.

    abstract:OBJECTIVE:Intramuscular electromyography (iEMG) signals, non-invasively recorded, directly from the muscles are used to diagnose various neuromuscular disorders/diseases, also to control rehabilitative and assistive robotic devices. iEMG signals are being potentially used in neurology, kinesiology, rehabilitation, and ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abcc7f

    authors: Ashraf H,Waris A,Gilani SO,Kashif AS,Jamil M,Jochumsen M,Niazi IK

    更新日期:2020-11-20 00:00:00

  • In vivo polymerization of poly(3,4-ethylenedioxythiophene) in the living rat hippocampus does not cause a significant loss of performance in a delayed alternation task.

    abstract::After extended implantation times, traditional intracortical neural probes exhibit a foreign-body reaction characterized by a reactive glial sheath that has been associated with increased system impedance and signal deterioration. Previously, we have proposed that the local in vivo polymerization of an electronically ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/2/026005

    authors: Ouyang L,Shaw CL,Kuo CC,Griffin AL,Martin DC

    更新日期:2014-04-01 00:00:00

  • Exploring non-stationarity patterns in schizophrenia: neural reorganization abnormalities in the alpha band.

    abstract:OBJECTIVE:The aim of this paper was to characterize brain non-stationarity during an auditory oddball task in schizophrenia (SCH). The level of non-stationarity was measured in the baseline and response windows of relevant tones in SCH patients and healthy controls. APPROACH:Event-related potentials were recorded from...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa6e05

    authors: Núñez P,Poza J,Bachiller A,Gomez-Pilar J,Lubeiro A,Molina V,Hornero R

    更新日期:2017-08-01 00:00:00

  • The response of retinal neurons to high-frequency stimulation.

    abstract:OBJECTIVE:High-rate pulse trains have proven to be effective in cochlear prosthetics and, more recently, have been shown to elicit a wide range of interesting response properties in axons of the peripheral nervous system. Surprisingly, the effectiveness of such trains for use in retinal prostheses has not been explored...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/3/036009

    authors: Cai C,Twyford P,Fried S

    更新日期:2013-06-01 00:00:00

  • Influence of nerve cuff channel count and implantation site on the separability of afferent ENG.

    abstract:OBJECTIVE:Recording of neural signals from intact peripheral nerves in patients with spinal cord injury or stroke survivors offers the possibility for the development of closed-loop sensorimotor prostheses. Nerve cuffs have been found to provide stable recordings from peripheral nerves for prolonged periods of time. Ho...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aabca0

    authors: Silveira C,Brunton E,Spendiff S,Nazarpour K

    更新日期:2018-08-01 00:00:00