Abstract:
OBJECTIVE:Filter bank canonical correlation analysis (FBCCA) is a widely-used classification approach implemented in steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs). However, conventional detection algorithms for SSVEP recognition problems, including the FBCCA, were usually based on 'fixed window' strategy. That's to say, these algorithms always analyze data with fixed length. This study devoted to enhance the performance of SSVEP-based BCIs by designing a new dynamic window strategy which automatically finds an optimal data length to achieve higher information transfer rate (ITR). APPROACH:The main purpose of 'dynamic window' is to minimize the required data length while maintaining high accuracy. This study projected the correlation coefficients of FBCCA into probability space by softmax function and built a hypothesis testing model, which took risk function as evaluation of classification result's 'credibility'. In order to evaluate the superiority of this approach, FBCCA with fixed data length (FBCCA-FW) and spatial temporal equalization dynamic window (STE-DW) were implemented for comparison. MAIN RESULTS:Fourteen healthy subjects' results were concluded by a 40-target online SSVEP-based BCI speller system. The results suggest that this proposed approach significantly outperforms STE-DW and FBCCA-FW in terms of accuracy and ITR. SIGNIFICANCE:By incorporating the fundamental ideas of FBCCA and dynamic window strategy, this study proposed a new training-free dynamical optimization algorithm, which significantly improved the performance of online SSVEP-based BCI systems.
journal_name
J Neural Engjournal_title
Journal of neural engineeringauthors
Chen Y,Yang C,Chen X,Wang Y,Gao Xdoi
10.1088/1741-2552/ab914esubject
Has Abstractpub_date
2020-05-07 00:00:00eissn
1741-2560issn
1741-2552pub_type
杂志文章abstract:OBJECTIVE:Medical implants made of non-biological materials provoke a chronic inflammatory response, resulting in the deposition of a collagenous scar tissue (ST) layer on their surface, that gradually thickens over time. This is a critical problem for neural interfaces. Scar build-up on electrodes results in a progres...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/13/2/026006
更新日期:2016-04-01 00:00:00
abstract:OBJECTIVE:The Subthalamic Nucleus (STN) is the most selected target for the placement of the Deep Brain Stimulation (DBS) electrode to treat Parkinson's disease. Its identification is a delicate and challenging task which is based on the interpretation of the STN functional activity acquired through microelectrode reco...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abcb15
更新日期:2020-11-17 00:00:00
abstract:OBJECTIVES:We aimed to develop a robotic interface capable of providing finely-tuned, multidirectional trunk assistance adjusted in real-time during unconstrained locomotion in rats and mice. APPROACH:We interfaced a large-scale robotic structure actuated in four degrees of freedom to exchangeable attachment modules e...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/13/2/026007
更新日期:2016-04-01 00:00:00
abstract::In a recent paper by Bradberry, Gentili and Contreras-Vidal published in Journal of Neural Engineering (2011, 8 036010), an interesting method for the control of a two-dimensional mouse cursor was proposed, which apparently attained excellent control and good speed with relatively simple techniques. We believe some of...
journal_title:Journal of neural engineering
pub_type: 评论,杂志文章
doi:10.1088/1741-2560/8/5/058001
更新日期:2011-10-01 00:00:00
abstract::To properly observe induced connectivity changes after training sessions, one needs a network model that describes individual relationships in sufficient detail to enable observation of induced changes and yet reveals some kind of stability in these relationships. We analyzed spontaneous firing activity in dissociated...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/4/2/006
更新日期:2007-06-01 00:00:00
abstract::Deep brain stimulation (DBS) of the subthalamic nucleus with periodic, high-frequency pulse trains is an increasingly standard therapy for advanced Parkinson's disease. Here, we propose that a closed-loop global optimization algorithm may identify novel DBS waveforms that could be more effective than their high-freque...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/4/2/L03
更新日期:2007-06-01 00:00:00
abstract::Human trials of prototype visual prostheses have successfully elicited visual percepts (phosphenes) in the visual field of implant recipients blinded through retinitis pigmentosa and age-related macular degeneration. Researchers are progressing rapidly towards a device that utilizes individual phosphenes as the elemen...
journal_title:Journal of neural engineering
pub_type: 杂志文章,评审
doi:10.1088/1741-2560/6/3/035009
更新日期:2009-06-01 00:00:00
abstract:OBJECTIVE:We have previously demonstrated a brain-machine interface neuroprosthetic system that provided continuous control of functional electrical stimulation (FES) and restoration of grasp in a primate model of spinal cord injury (SCI). Predicting intended EMG directly from cortical recordings provides a flexible hi...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/13/4/046009
更新日期:2016-08-01 00:00:00
abstract::A motor imagery based brain-computer interface (BCI) provides a non-muscular communication channel that enables people with paralysis to control external devices using their motor imagination. Reducing the number of electrodes is critical to improving the portability and practicability of the BCI system. A novel metho...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/5/3/007
更新日期:2008-09-01 00:00:00
abstract:OBJECTIVE:High-fidelity vibrokinetic (HFVK) technology is widely used to enhance the immersiveness of audiovisual (AV) entertainment experiences. However, despite evidence that HFVK technology does subjectively enhance AV immersion, the underlying mechanism has not been clarified. Neurophysiological studies could provi...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abaca2
更新日期:2020-09-26 00:00:00
abstract:OBJECTIVE:There has recently been an increasing interest in local field potential (LFP) for brain-machine interface (BMI) applications due to its desirable properties (signal stability and low bandwidth). LFP is typically recorded with respect to a single unipolar reference which is susceptible to common noise. Several...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abce3c
更新日期:2020-11-26 00:00:00
abstract::In this work, we proposed a novel architecture for real-time quantitative characterization of functional brain connectivity networks derived from Electroencephalogram (EEG). It consists of two main parts - calculation of Phase Lag Index (PLI) to form the functional connectivity networks and the extraction of a set of ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abd462
更新日期:2020-12-16 00:00:00
abstract::Electrical stimulation of peripheral nerve activates large-diameter fibers before small ones. A physiological recruitment order, from small to large-diameter axons, is desirable in many applications. Previous studies using computer simulations showed that selective activation of small fibers could be achieved by resha...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/1/4/003
更新日期:2004-12-01 00:00:00
abstract:OBJECTIVE:This study employs a human head model with real skull to demonstrate the feasibility of transcranial acoustoelectric brain imaging (tABI) as a new modality for electrical mapping of deep dipole sources during treatment of epilepsy with much better resolution and accuracy than conventional mapping methods. AP...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abb63a
更新日期:2020-10-30 00:00:00
abstract::This paper describes the technological developments underlying the realization of a reliable and reproducible microchip-based stimulator with a large number of stimulus electrodes. A microchip-based stimulator with over 500 electrodes for suprachoroidal transretinal stimulation (STS) is proposed in this paper, and an ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/4/1/S10
更新日期:2007-03-01 00:00:00
abstract:OBJECTIVE:Rhythmic brain stimulation has emerged as a powerful tool to modulate cognition and to target pathological oscillations related to neurological and psychiatric disorders. However, we lack a systematic understanding of how periodic stimulation interacts with endogenous neural activity as a function of the brai...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aaeb03
更新日期:2019-02-01 00:00:00
abstract::Corrosion is a prime concern for active implantable devices. In this paper we review the principles underlying the concepts of hermetic packages and encapsulation, used to protect implanted electronics, some of which remain widely overlooked. We discuss how technological advances have created a need to update the way ...
journal_title:Journal of neural engineering
pub_type: 杂志文章,评审
doi:10.1088/1741-2560/10/3/031002
更新日期:2013-06-01 00:00:00
abstract::Alzheimer's disease (AD) is the most common cause of dementia. Over the last few years, a considerable effort has been devoted to exploring new biomarkers. Nevertheless, a better understanding of brain dynamics is still required to optimize therapeutic strategies. In this regard, the characterization of mild cognitive...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/9/3/036007
更新日期:2012-06-01 00:00:00
abstract:OBJECTIVE:To evaluate the potential of intracortical electrode array signals for brain-computer interfaces (BCIs) to restore lost speech, we measured the performance of decoders trained to discriminate a comprehensive basis set of 39 English phonemes and to synthesize speech sounds via a neural pattern matching method....
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abbfef
更新日期:2020-11-25 00:00:00
abstract:OBJECTIVE:Assessing an infant's brain development remains a challenge for neuroscientists and pediatricians despite great technological advances. As a non-invasive neuroimaging tool, functional near-infrared spectroscopy (fNIRS) has great advantages in monitoring an infant's brain activity. To explore the dynamic featu...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aae0c9
更新日期:2018-12-01 00:00:00
abstract:OBJECTIVE:Penetrating cortical neural probe technologies allow investigators to record electrical signals in the brain. Implantation of probes results in acute tissue damage, and microglia density increases around implanted devices over weeks. However, the mechanisms underlying this encapsulation are not well understoo...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/9/6/066001
更新日期:2012-12-01 00:00:00
abstract:OBJECTIVE:While motor-imagery based brain-computer interfaces (BCIs) have been studied over many years by now, most of these studies have taken place in controlled lab settings. Bringing BCI technology into everyday life is still one of the main challenges in this field of research. APPROACH:This paper systematically ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/13/5/056012
更新日期:2016-10-01 00:00:00
abstract:OBJECTIVE:The use of natural sounds in auditory Brain-Computer Interfaces (BCI) has been shown to improve classification results and usability. Some auditory BCIs are based on stream segregation, in which the subjects must attend one audio stream and ignore the other(s); these streams include some kind of stimuli to be...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abdd44
更新日期:2021-01-19 00:00:00
abstract::We present the results of a 5-year patient follow-up after implantation of an original neuroprosthesis. The system is able to stimulate both epimysial and neural electrodes in such a way that the complete flexor-extensor chain of the lower limb can be activated without using the withdrawal reflex. We demonstrate that ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/3/4/003
更新日期:2006-12-01 00:00:00
abstract:OBJECTIVE:Low-intensity focused ultrasound stimulation (LIFUS) emerges as an attracting technology for noninvasive modulation of neural circuits, yet the underlying action mechanisms remain unclear. The neuronal intramembrane cavitation excitation (NICE) model suggests that LIFUS excites neurons through a complex inter...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab1685
更新日期:2019-08-01 00:00:00
abstract:OBJECTIVE:Retinal prosthetic implants restore partial vision to patients blinded due to outer retinal degeneration, using a camera-guided multielectrode array (MEA) that electrically stimulates surviving retinal neurons. Commercial epi-retinal prostheses use millisecond-scale charge-balanced, symmetric, cathodic-first ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aaf92b
更新日期:2019-04-01 00:00:00
abstract:OBJECTIVE:By means of subjective psychophysical methods, quality of transmitted speech has been decomposed into three perceptual dimensions named 'discontinuity' (F), 'noisiness' (N) and 'coloration' (C). Previous studies using electroencephalography (EEG) already reported effects of perceived intensity of single quali...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aaf122
更新日期:2019-06-01 00:00:00
abstract:OBJECTIVE:The goal of this study is to characterize the phenomenon of evoked tactile sensation (ETS) on the stump skin of forearm amputees using transcutaneous electrical nerve stimulation (TENS). APPROACH:We identified the projected finger map (PFM) of ETS on the stump skin in 11 forearm amputees, and compared percep...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/12/6/066002
更新日期:2015-12-01 00:00:00
abstract::The functional effects of selective hypoglossal nerve (HG) stimulation with a multi-contact peripheral nerve electrode were assessed using images of the upper airways and the tongue in anesthetized beagles. A biphasic pulse train of 50 Hz frequency and 2 s duration was applied through each one of the tripolar contact ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/2/4/002
更新日期:2005-12-01 00:00:00
abstract::We describe a brain-computer interface for controlling a humanoid robot directly using brain signals obtained non-invasively from the scalp through electroencephalography (EEG). EEG has previously been used for tasks such as controlling a cursor and spelling a word, but it has been regarded as an unlikely candidate fo...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/5/2/012
更新日期:2008-06-01 00:00:00