Abstract:
:Corrosion is a prime concern for active implantable devices. In this paper we review the principles underlying the concepts of hermetic packages and encapsulation, used to protect implanted electronics, some of which remain widely overlooked. We discuss how technological advances have created a need to update the way we evaluate the suitability of both protection methods. We demonstrate how lifetime predictability is lost for very small hermetic packages and introduce a single parameter to compare different packages, with an equation to calculate the minimum sensitivity required from a test method to guarantee a given lifetime. In the second part of this paper, we review the literature on the corrosion of encapsulated integrated circuits (ICs) and, following a new analysis of published data, we propose an equation for the pre-corrosion lifetime of implanted ICs, and discuss the influence of the temperature, relative humidity, encapsulation and field-strength. As any new protection will be tested under accelerated conditions, we demonstrate the sensitivity of acceleration factors to some inaccurately known parameters. These results are relevant for any application of electronics working in a moist environment. Our comparison of encapsulation and hermetic packages suggests that both concepts may be suitable for future implants.
journal_name
J Neural Engjournal_title
Journal of neural engineeringauthors
Vanhoestenberghe A,Donaldson Ndoi
10.1088/1741-2560/10/3/031002subject
Has Abstractpub_date
2013-06-01 00:00:00pages
031002issue
3eissn
1741-2560issn
1741-2552journal_volume
10pub_type
杂志文章,评审abstract:OBJECTIVE:Deep brain stimulation (DBS) of the internal segment of the globus pallidus (GPi) in patients with Parkinson's disease and dystonia improves motor symptoms and quality of life. Traditionally, pallidal borders have been demarcated by electrophysiological microelectrode recordings (MERs) during DBS surgery. How...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab53ac
更新日期:2020-01-06 00:00:00
abstract:OBJECTIVE:Brains, like other physical devices, are inherently noisy. This source of variability is large, to the extent that internal noise often impacts human sensory processing more than externally induced (stimulus-driven) perturbations. Despite the fundamental nature of this phenomenon, its statistical distribution...
journal_title:Journal of neural engineering
pub_type: 杂志文章,随机对照试验
doi:10.1088/1741-2560/10/1/016014
更新日期:2013-02-01 00:00:00
abstract::A clinically effective retinal prosthesis must evoke localized phosphenes in a retinotopic manner in response to stimulation of each of the retinal electrodes, evoke brightness cues over a wide dynamic range and function within safe stimulus limits. The effects of varying return configuration for retinal stimulation a...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/9/3/036009
更新日期:2012-06-01 00:00:00
abstract:OBJECTIVE:Electrocorticography (ECoG) based studies generally analyze features from specific frequency bands selected by manual evaluation of spectral power. However, the definition of these features can vary across subjects, cortical areas, tasks and across time for a given subject. We propose an autoencoder based app...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aaf13f
更新日期:2019-02-01 00:00:00
abstract:OBJECTIVE:The various parameters that define a hand movement such as its trajectory, speed, etc, are encoded in distinct brain activities. Decoding this information from neurophysiological recordings is a less explored area of brain-computer interface (BCI) research. Applying non-invasive recordings such as electroence...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/12/6/066019
更新日期:2015-12-01 00:00:00
abstract::In a recent paper by Bradberry, Gentili and Contreras-Vidal published in Journal of Neural Engineering (2011, 8 036010), an interesting method for the control of a two-dimensional mouse cursor was proposed, which apparently attained excellent control and good speed with relatively simple techniques. We believe some of...
journal_title:Journal of neural engineering
pub_type: 评论,杂志文章
doi:10.1088/1741-2560/8/5/058001
更新日期:2011-10-01 00:00:00
abstract:OBJECTIVE:Dry electrodes have an advantage over gel-based 'wet' electrodes by providing quicker set-up time for electroencephalography recording; however, the potentially poorer contact can result in noisier recordings. We examine the impact that this may have on brain-computer interface communication and potential app...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/13/6/066018
更新日期:2016-12-01 00:00:00
abstract:OBJECTIVE:Brain-computer interfaces (BCI) are becoming important tools for assistive technology, particularly through the use of motor imagery (MI) for aiding task completion. However, most existing methods of MI classification have been applied in a trial-wise fashion, with window sizes of approximately 2 s or more. A...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab57c0
更新日期:2020-01-31 00:00:00
abstract:OBJECTIVE:Neuromusculoskeletal models involve many subject-specific physiological parameters that need to be adjusted to adequately represent muscle properties. Traditionally, neuromusculoskeletal models have been calibrated with a forward-inverse dynamic optimization which is time-consuming and unfeasible for rehabili...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aa58f5
更新日期:2017-04-01 00:00:00
abstract::We investigated the relationships of the firing rate and maximal recruitment threshold of motoneurons recorded during isometric contraction with the number of spindles in individual muscles. At force levels above 10% of maximal voluntary contraction, the firing rate was inversely related to the number of spindles in a...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/9/1/016007
更新日期:2012-02-01 00:00:00
abstract:OBJECTIVE:Current brain-computer interface (BCI) studies demonstrate the potential to decode neural signals obtained from structured and trial-based tasks to drive actuators with high performance within the context of these tasks. Ideally, to maximize utility, such systems will be applied to a wide range of behavioral ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aaee9c
更新日期:2019-02-01 00:00:00
abstract:OBJECTIVE:Intracranial EEG (iEEG) or micro-electrocorticography (µECoG) microelectrodes offer high spatial resolution in recordings of neuronal activity from the exposed brain surface. Reliability of dielectric substrates and conductive materials of these devices are under intensive research in terms of functional stab...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aacf71
更新日期:2018-10-01 00:00:00
abstract::We conducted an experiment to determine whether the rhythm with which imagined syllables are produced may be decoded from EEG recordings. High density EEG data were recorded for seven subjects while they produced in imagination one of two syllables in one of three different rhythms. We used a modified second-order bli...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/7/4/046006
更新日期:2010-08-01 00:00:00
abstract:OBJECTIVE:Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aba560
更新日期:2020-08-05 00:00:00
abstract:OBJECTIVE:Assessing an infant's brain development remains a challenge for neuroscientists and pediatricians despite great technological advances. As a non-invasive neuroimaging tool, functional near-infrared spectroscopy (fNIRS) has great advantages in monitoring an infant's brain activity. To explore the dynamic featu...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aae0c9
更新日期:2018-12-01 00:00:00
abstract::The extraction of distinctly separable features from electroencephalogram (EEG) is one of the main challenges in designing a brain-computer interface (BCI). Existing feature extraction techniques for a BCI are mostly developed based on traditional signal processing techniques assuming that the signal is Gaussian and h...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/8/2/025014
更新日期:2011-04-01 00:00:00
abstract:OBJECTIVE:Recording of neural signals from intact peripheral nerves in patients with spinal cord injury or stroke survivors offers the possibility for the development of closed-loop sensorimotor prostheses. Nerve cuffs have been found to provide stable recordings from peripheral nerves for prolonged periods of time. Ho...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aabca0
更新日期:2018-08-01 00:00:00
abstract:OBJECTIVE:Filter bank canonical correlation analysis (FBCCA) is a widely-used classification approach implemented in steady-state visual evoked potential (SSVEP)-based brain-computer interfaces (BCIs). However, conventional detection algorithms for SSVEP recognition problems, including the FBCCA, were usually based on ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab914e
更新日期:2020-05-07 00:00:00
abstract:OBJECTIVE:Depression is a severe mental disorder. However, the neural mechanisms underlying affective interference (difficulties in directing attention away from negative distractors) in depression patients are still not well-understood. In particular, the connections between brain regions remain unclear. Using the emo...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aacdbb
更新日期:2018-10-01 00:00:00
abstract:OBJECTIVE:High-fidelity vibrokinetic (HFVK) technology is widely used to enhance the immersiveness of audiovisual (AV) entertainment experiences. However, despite evidence that HFVK technology does subjectively enhance AV immersion, the underlying mechanism has not been clarified. Neurophysiological studies could provi...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abaca2
更新日期:2020-09-26 00:00:00
abstract::The blood oxygenation level dependent (BOLD) contrast has been commonly used to detect fMRI signal. The majority of the BOLD signals are believed to arise from the venous and capillary networks. However, only those from the capillaries are spatially close to the neuronal activities, while the signals from large veins ...
journal_title:Journal of neural engineering
pub_type: 临床试验,杂志文章
doi:10.1088/1741-2560/1/1/005
更新日期:2004-03-01 00:00:00
abstract::With the advent of new designs of visual prostheses for the blind, FDA is faced with developing guidance for evaluating their engineering, safety and patient performance. Visual prostheses are considered significant risk medical devices, and their use in human clinical trials must be approved by FDA under an investiga...
journal_title:Journal of neural engineering
pub_type: 杂志文章,评审
doi:10.1088/1741-2560/4/1/S14
更新日期:2007-03-01 00:00:00
abstract:OBJECTIVE:Predicting how the brain can be driven to specific states by means of internal or external control requires a fundamental understanding of the relationship between neural connectivity and activity. Network control theory is a powerful tool from the physical and engineering sciences that can provide insights r...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab6e8b
更新日期:2020-04-09 00:00:00
abstract:OBJECTIVE:Neural reflexes regulate immune responses and homeostasis. Advances in bioelectronic medicine indicate that electrical stimulation of the vagus nerve can be used to treat inflammatory disease, yet the understanding of neural signals that regulate inflammation is incomplete. Current interfaces with the vagus n...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aa7a42
更新日期:2017-12-01 00:00:00
abstract:OBJECTIVE:A major difficulty of brain-computer interface (BCI) technology is dealing with the noise of EEG and its signal variations. Previous works studied time-dependent non-stationarities for BCIs in which the user's mental task was independent of the device operation (e.g., the mental task was motor imagery and the...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/10/2/026024
更新日期:2013-04-01 00:00:00
abstract:OBJECTIVE:The rapidly developing paradigm of closed-loop neuroscience has extensively employed brain rhythms as the signal forming real-time neurofeedback, triggering brain stimulation, or governing stimulus selection. However, the efficacy of brain rhythm contingent paradigms suffers from significant delays related to...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab890f
更新日期:2020-08-04 00:00:00
abstract:OBJECTIVE:This study employs a human head model with real skull to demonstrate the feasibility of transcranial acoustoelectric brain imaging (tABI) as a new modality for electrical mapping of deep dipole sources during treatment of epilepsy with much better resolution and accuracy than conventional mapping methods. AP...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abb63a
更新日期:2020-10-30 00:00:00
abstract::Brain-computer interface (BCI) systems allow people with severe motor disabilities to communicate and interact with the external world. The P300 potential is one of the most used control signals for EEG-based BCIs. Classic P300-based BCIs work in a synchronous mode; the synchronous control assumes that the user is con...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/8/2/025025
更新日期:2011-04-01 00:00:00
abstract:OBJECTIVE:In a previous study we demonstrated continuous translation, orientation and one-dimensional grasping control of a prosthetic limb (seven degrees of freedom) by a human subject with tetraplegia using a brain-machine interface (BMI). The current study, in the same subject, immediately followed the previous work...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/12/1/016011
更新日期:2015-02-01 00:00:00
abstract:OBJECTIVE:This paper discusses the invariance and variability in interaction error-related potentials (ErrPs), where a special focus is laid upon the factors of (1) the human mental processing required to assess interface actions (2) time (3) subjects. APPROACH:Three different experiments were designed as to vary prim...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aa8416
更新日期:2017-12-01 00:00:00