Characterization of evoked tactile sensation in forearm amputees with transcutaneous electrical nerve stimulation.

Abstract:

OBJECTIVE:The goal of this study is to characterize the phenomenon of evoked tactile sensation (ETS) on the stump skin of forearm amputees using transcutaneous electrical nerve stimulation (TENS). APPROACH:We identified the projected finger map (PFM) of ETS on the stump skin in 11 forearm amputees, and compared perceptual attributes of the ETS in nine forearm amputees and eight able-bodied subjects using TENS. The profile of perceptual thresholds at the most sensitive points (MSPs) in each finger-projected area was obtained by modulating current amplitude, pulse width, and frequency of the biphasic, rectangular current stimulus. The long-term stability of the PFM and the perceptual threshold of the ETS were monitored in five forearm amputees for a period of 11 months. MAIN RESULTS:Five finger-specific projection areas can be independently identified on the stump skin of forearm amputees with a relatively long residual stump length. The shape of the PFM was progressively similar to that of the hand with more distal amputation. Similar sensory modalities of touch, pressure, buzz, vibration, and numb below pain sensation could be evoked both in the PFM of the stump skin of amputees and in the normal skin of able-bodied subjects. Sensory thresholds in the normal skin of able-bodied subjects were generally lower than those in the stump skin of forearm amputees, however, both were linearly modulated by current amplitude and pulse width. The variation of the MSPs in the PFM was confined to a small elliptical area with 95% confidence. The perceptual thresholds of thumb-projected areas were found to vary less than 0.99 × 10(-2) mA cm(-2). SIGNIFICANCE:The stable PFM and sensory thresholds of ETS are desirable for a non-invasive neural interface that can feed back finger-specific tactile information from the prosthetic hand to forearm amputees.

journal_name

J Neural Eng

authors

Chai G,Sui X,Li S,He L,Lan N

doi

10.1088/1741-2560/12/6/066002

subject

Has Abstract

pub_date

2015-12-01 00:00:00

pages

066002

issue

6

eissn

1741-2560

issn

1741-2552

journal_volume

12

pub_type

杂志文章
  • Object stiffness recognition using haptic feedback delivered through transcutaneous proximal nerve stimulation.

    abstract:OBJECTIVE:Haptic feedback is crucial when we manipulate objects. Information pertaining to an object's stiffness in particular can help facilitate fine motor control. In this study, we seek to determine whether objects of different stiffness levels can be recognized using haptic feedback provided by transcutaneous elec...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab4d99

    authors: Vargas L,Shin H,Huang HH,Zhu Y,Hu X

    更新日期:2019-12-05 00:00:00

  • Classification and regression of spatio-temporal signals using NeuCube and its realization on SpiNNaker neuromorphic hardware.

    abstract:OBJECTIVE:The objective of this work is to use the capability of spiking neural networks to capture the spatio-temporal information encoded in time-series signals and decode them without the use of hand-crafted features and vector-based learning and the realization of the spiking model on low-power neuromorphic hardwar...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aafabc

    authors: Behrenbeck J,Tayeb Z,Bhiri C,Richter C,Rhodes O,Kasabov N,Espinosa-Ramos JI,Furber S,Cheng G,Conradt J

    更新日期:2019-04-01 00:00:00

  • Computationally inexpensive enhanced growing neural gas algorithm for real-time adaptive neural spike clustering.

    abstract:OBJECTIVE:Real-time closed-loop neural feedback control requires the analysis of action potential traces within several milliseconds after they have been recorded from the brain. The current generation of spike clustering algorithms were mostly designed for off-line use and also require a significant amount of computat...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab208c

    authors: Mohammadi Z,Kincaid JM,Pun SH,Klug A,Liu C,Lei TC

    更新日期:2019-07-30 00:00:00

  • Progress in artificial vision through suprachoroidal retinal implants.

    abstract::Retinal implants have proven their ability to restore visual sensation to people with degenerative retinopathy, characterized by photoreceptor cell death and the retina's inability to sense light. Retinal bionics operate by electrically stimulating the surviving neurons in the retina, thus triggering the transfer of v...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2552/aa6cbb

    authors: Bareket L,Barriga-Rivera A,Zapf MP,Lovell NH,Suaning GJ

    更新日期:2017-08-01 00:00:00

  • Force estimation from ensembles of Golgi tendon organs.

    abstract::Golgi tendon organs (GTOs) located in the skeletal muscles provide the central nervous system with information about muscle tension. The ensemble firing of all GTO receptors in the muscle has been hypothesized to represent a reliable measure of the whole muscle force but the precision and accuracy of that information ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/6/3/036001

    authors: Mileusnic MP,Loeb GE

    更新日期:2009-06-01 00:00:00

  • Brain-actuated gait trainer with visual and proprioceptive feedback.

    abstract:OBJECTIVE:Brain-machine interfaces (BMIs) have been proposed in closed-loop applications for neuromodulation and neurorehabilitation. This study describes the impact of different feedback modalities on the performance of an EEG-based BMI that decodes motor imagery (MI) of leg flexion and extension. APPROACH:We execute...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa7df9

    authors: Liu D,Chen W,Lee K,Chavarriaga R,Bouri M,Pei Z,Del R Millán J

    更新日期:2017-10-01 00:00:00

  • Focused electrical stimulation using a single current source.

    abstract:OBJECTIVE:Cochlear implants, while providing significant benefits to recipients, remain limited due to broad neural activation. Focussed multipolar stimulation (FMP) is an advanced stimulation strategy that uses multiple current sources to produce highly focussed patterns of neural excitation in order to overcome these...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aad0a5

    authors: Senn P,Shepherd RK,Fallon JB

    更新日期:2018-10-01 00:00:00

  • Pavlovian control of intraspinal microstimulation to produce over-ground walking.

    abstract:OBJECTIVE:Neuromodulation technologies are increasingly used for improving function after neural injury. To achieve a symbiotic relationship between device and user, the device must augment remaining function, and independently adapt to day-to-day changes in function. The goal of this study was to develop predictive co...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab8e8e

    authors: Dalrymple AN,Roszko DA,Sutton RS,Mushahwar VK

    更新日期:2020-06-02 00:00:00

  • Amplitude versus spatially modulated electrotactile feedback for myoelectric control of two degrees of freedom.

    abstract:OBJECTIVE:Artificial proprioceptive feedback from a myoelectric prosthesis is an important aspect in enhancing embodiment and user satisfaction, possibly lowering the demand for visual attention while controlling a prosthesis in everyday tasks. Contemporary myoelectric prostheses are advanced mechatronic systems with m...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aba4fd

    authors: Garenfeld MA,Mortensen CK,Strbac M,Dideriksen JL,Dosen S

    更新日期:2020-08-14 00:00:00

  • Probabilistic co-adaptive brain-computer interfacing.

    abstract:OBJECTIVE:Brain-computer interfaces (BCIs) are confronted with two fundamental challenges: (a) the uncertainty associated with decoding noisy brain signals, and (b) the need for co-adaptation between the brain and the interface so as to cooperatively achieve a common goal in a task. We seek to mitigate these challenges...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/6/066008

    authors: Bryan MJ,Martin SA,Cheung W,Rao RP

    更新日期:2013-12-01 00:00:00

  • Natural language processing with dynamic classification improves P300 speller accuracy and bit rate.

    abstract::The P300 speller is an example of a brain-computer interface that can restore functionality to victims of neuromuscular disorders. Although the most common application of this system has been communicating language, the properties and constraints of the linguistic domain have not to date been exploited when decoding b...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/1/016004

    authors: Speier W,Arnold C,Lu J,Taira RK,Pouratian N

    更新日期:2012-02-01 00:00:00

  • Carbon nanotube composite coating of neural microelectrodes preferentially improves the multiunit signal-to-noise ratio.

    abstract::Extracellular metal microelectrodes are widely used to record single neuron activity in vivo. However, their signal-to-noise ratio (SNR) is often far from optimal due to their high impedance value. It has been recently reported that carbon nanotube (CNT) coatings may decrease microelectrode impedance, thus improving t...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/6/066013

    authors: Baranauskas G,Maggiolini E,Castagnola E,Ansaldo A,Mazzoni A,Angotzi GN,Vato A,Ricci D,Panzeri S,Fadiga L

    更新日期:2011-12-01 00:00:00

  • Lower layers in the motor cortex are more effective targets for penetrating microelectrodes in cortical prostheses.

    abstract::Improving cortical prostheses requires the development of recording neural interfaces that are efficient in terms of providing maximal control information with minimal interface complexity. While the typical approaches have targeted neurons in the motor cortex with multiple penetrating shanks, an alternative approach ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/6/2/026004

    authors: Parikh H,Marzullo TC,Kipke DR

    更新日期:2009-04-01 00:00:00

  • Influence of field of view in visual prostheses design: Analysis with a VR system.

    abstract:OBJECTIVE:Visual prostheses are designed to restore partial functional vision in patients with total vision loss. Retinal visual prostheses provide limited capabilities as a result of low resolution, limited field of view and poor dynamic range. Understanding the influence of these parameters in the perception results ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abb9be

    authors: Sanchez-Garcia M,Martinez-Cantin R,Bermudez-Cameo J,Guerrero JJ

    更新日期:2020-10-08 00:00:00

  • Evoked haptic sensations in the hand via non-invasive proximal nerve stimulation.

    abstract:OBJECTIVE:Haptic perception of a prosthetic limb or hand is a crucial, but often unmet, need which impacts the utility of the prostheses. In this study, we seek to evaluate the feasibility of a non-invasive transcutaneous nerve stimulation method in generating haptic feedback in a transradial amputee subject as well as...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aabd5d

    authors: Shin H,Watkins Z,Huang HH,Zhu Y,Hu X

    更新日期:2018-08-01 00:00:00

  • Exploring non-stationarity patterns in schizophrenia: neural reorganization abnormalities in the alpha band.

    abstract:OBJECTIVE:The aim of this paper was to characterize brain non-stationarity during an auditory oddball task in schizophrenia (SCH). The level of non-stationarity was measured in the baseline and response windows of relevant tones in SCH patients and healthy controls. APPROACH:Event-related potentials were recorded from...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa6e05

    authors: Núñez P,Poza J,Bachiller A,Gomez-Pilar J,Lubeiro A,Molina V,Hornero R

    更新日期:2017-08-01 00:00:00

  • Applying dynamic data collection to improve dry electrode system performance for a P300-based brain-computer interface.

    abstract:OBJECTIVE:Dry electrodes have an advantage over gel-based 'wet' electrodes by providing quicker set-up time for electroencephalography recording; however, the potentially poorer contact can result in noisier recordings. We examine the impact that this may have on brain-computer interface communication and potential app...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/6/066018

    authors: Clements JM,Sellers EW,Ryan DB,Caves K,Collins LM,Throckmorton CS

    更新日期:2016-12-01 00:00:00

  • Control of a humanoid robot by a noninvasive brain-computer interface in humans.

    abstract::We describe a brain-computer interface for controlling a humanoid robot directly using brain signals obtained non-invasively from the scalp through electroencephalography (EEG). EEG has previously been used for tasks such as controlling a cursor and spelling a word, but it has been regarded as an unlikely candidate fo...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/5/2/012

    authors: Bell CJ,Shenoy P,Chalodhorn R,Rao RP

    更新日期:2008-06-01 00:00:00

  • Functional vagotopy in the cervical vagus nerve of the domestic pig: implications for the study of vagus nerve stimulation.

    abstract:OBJECTIVE:Given current clinical interest in vagus nerve stimulation (VNS), there are surprisingly few studies characterizing the anatomy of the vagus nerve in large animal models as it pertains to on-and off-target engagement of local fibers. We sought to address this gap by evaluating vagal anatomy in the pig, whose ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab7ad4

    authors: Settell ML,Pelot NA,Knudsen BE,Dingle AM,McConico AL,Nicolai EN,Trevathan JK,Ezzell JA,Ross EK,Gustafson KJ,Shoffstall AJ,Williams JC,Zeng W,Poore SO,Populin LC,Suminski AJ,Grill WM,Ludwig KA

    更新日期:2020-04-09 00:00:00

  • Altered electroencephalography functional connectivity in depression during the emotional face-word Stroop task.

    abstract:OBJECTIVE:Depression is a severe mental disorder. However, the neural mechanisms underlying affective interference (difficulties in directing attention away from negative distractors) in depression patients are still not well-understood. In particular, the connections between brain regions remain unclear. Using the emo...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aacdbb

    authors: Guo Z,Wu X,Liu J,Yao L,Hu B

    更新日期:2018-10-01 00:00:00

  • Stem cells from human exfoliated deciduous teeth differentiate toward neural cells in a medium dynamically cultured with Schwann cells in a series of polydimethylsiloxanes scaffolds.

    abstract:OBJECTIVE:Schwann cells (SCs) are primary structural and functional cells in the peripheral nervous system. These cells play a crucial role in peripheral nerve regeneration by releasing neurotrophic factors. This study evaluated the neural differentiation potential effects of stem cells from human exfoliated deciduous ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/4/046005

    authors: Su WT,Pan YJ

    更新日期:2016-08-01 00:00:00

  • Ultraminiaturized photovoltaic and radio frequency powered optoelectronic systems for wireless optogenetics.

    abstract:OBJECTIVE:Wireless control and power harvesting systems that operate injectable, cellular-scale optoelectronic components provide important demonstrated capabilities in neuromodulatory techniques such as optogenetics. Here, we report a radio frequency (RF) control/harvesting device that offers dramatically reduced size...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/5/056002

    authors: Park SI,Shin G,Banks A,McCall JG,Siuda ER,Schmidt MJ,Chung HU,Noh KN,Mun JG,Rhodes J,Bruchas MR,Rogers JA

    更新日期:2015-10-01 00:00:00

  • Adaptive optimal input design and parametric estimation of nonlinear dynamical systems: application to neuronal modeling.

    abstract:OBJECTIVE:Many physical models of biological processes including neural systems are characterized by parametric nonlinear dynamical relations between driving inputs, internal states, and measured outputs of the process. Fitting such models using experimental data (data assimilation) is a challenging task since the phys...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aac3f7

    authors: Madi MK,Karameh FN

    更新日期:2018-08-01 00:00:00

  • P300-based brain-computer interface for environmental control: an asynchronous approach.

    abstract::Brain-computer interface (BCI) systems allow people with severe motor disabilities to communicate and interact with the external world. The P300 potential is one of the most used control signals for EEG-based BCIs. Classic P300-based BCIs work in a synchronous mode; the synchronous control assumes that the user is con...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/2/025025

    authors: Aloise F,Schettini F,Aricò P,Leotta F,Salinari S,Mattia D,Babiloni F,Cincotti F

    更新日期:2011-04-01 00:00:00

  • Informed consent in implantable BCI research: identification of research risks and recommendations for development of best practices.

    abstract:OBJECTIVE:Implantable brain-computer interface (BCI) research promises improvements in human health and enhancements in quality of life. Informed consent of subjects is a central tenet of this research. Rapid advances in neuroscience, and the intimate connection between functioning of the brain and conceptions of the s...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2560/13/4/043001

    authors: Klein E,Ojemann J

    更新日期:2016-08-01 00:00:00

  • Tissue-engineered nerve grafts using a scaffold-independent and injectable drug delivery system: a novel design with translational advantages.

    abstract:OBJECTIVE:Currently commercially available nerve conduits have demonstrated suboptimal clinical efficacy in repairing peripheral nerve defects. Although tissue-engineered nerve grafts (TENGs) with sustained release of neurotrophic factors (NTFs) are experimentally proved to be more effective than these blank conduits, ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab17a0

    authors: Liu Y,Yu S,Gu X,Cao R,Cui S

    更新日期:2019-06-01 00:00:00

  • Rehabilitation regimes based upon psychophysical studies of prosthetic vision.

    abstract::Human trials of prototype visual prostheses have successfully elicited visual percepts (phosphenes) in the visual field of implant recipients blinded through retinitis pigmentosa and age-related macular degeneration. Researchers are progressing rapidly towards a device that utilizes individual phosphenes as the elemen...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2560/6/3/035009

    authors: Chen SC,Suaning GJ,Morley JW,Lovell NH

    更新日期:2009-06-01 00:00:00

  • Real-time cerebellar neuroprosthetic system based on a spiking neural network model of motor learning.

    abstract:OBJECTIVE:Damage to the brain, as a result of various medical conditions, impacts the everyday life of patients and there is still no complete cure to neurological disorders. Neuroprostheses that can functionally replace the damaged neural circuit have recently emerged as a possible solution to these problems. Here we ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa98e9

    authors: Xu T,Xiao N,Zhai X,Kwan Chan P,Tin C

    更新日期:2018-02-01 00:00:00

  • Improved mobility performance with an artificial vision therapy system using a thermal sensor.

    abstract:OBJECTIVE:To evaluate the benefit of integrating thermal imaging into an artificial vision therapy system, the Argus II retinal prosthesis, in simplifying a complex scene and improving mobility performance in the presence of other persons. APPROACH:Four Argus II retinal implant users were evaluated on two tasks: to lo...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aba4fb

    authors: He Y,Sun SY,Roy A,Caspi A,Montezuma SR

    更新日期:2020-08-04 00:00:00

  • Neurite outgrowth at the interface of 2D and 3D growth environments.

    abstract::Growing neurons navigate complex environments, but in vitro systems for studying neuronal growth typically limit the cues to flat surfaces or a single type of cue, thereby limiting the resulting growth. Here we examined the growth of neurons presented with two-dimensional (2D) substrate-bound cues when these cues were...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/6/1/016002

    authors: Kofron CM,Fong VJ,Hoffman-Kim D

    更新日期:2009-02-01 00:00:00