Abstract:
OBJECTIVE:To evaluate the benefit of integrating thermal imaging into an artificial vision therapy system, the Argus II retinal prosthesis, in simplifying a complex scene and improving mobility performance in the presence of other persons. APPROACH:Four Argus II retinal implant users were evaluated on two tasks: to locate and approach target persons in a booth, and to navigate a hallway while avoiding people. They completed the tasks using both the original Argus II system (the 'Argus II camera') and a thermal-integrated Argus II system (the 'thermal camera'). The safety and efficiency of their navigation were evaluated by their walking speed, navigation errors, and the number of collisions. MAIN RESULTS:Navigation performance was significantly superior when using the thermal camera compared to using the Argus II camera, including 75% smaller angle of deviation (p < 0.001), 48% smaller error of distance (p < 0.05), and 30% fewer collisions (p < 0.05). The thermal camera also brought the additional benefit of allowing the participants to perform the task in the dark as efficiently as in the light. More importantly, these benefits did not come at a cost of reduced walking speed. SIGNIFICANCE:Using the thermal camera in the Argus II system, compared to a visible-light camera, could improve the wearers' navigation performance by helping them better approach or avoid other persons. Adding the thermal camera to future artificial vision therapy systems may complement the visible-light camera and improve the users' mobility safety and efficiency, enhancing their quality of life.
journal_name
J Neural Engjournal_title
Journal of neural engineeringauthors
He Y,Sun SY,Roy A,Caspi A,Montezuma SRdoi
10.1088/1741-2552/aba4fbsubject
Has Abstractpub_date
2020-08-04 00:00:00pages
045011issue
4eissn
1741-2560issn
1741-2552journal_volume
17pub_type
杂志文章abstract::Brain-computer interface (BCI) systems allow people with severe motor disabilities to communicate and interact with the external world. The P300 potential is one of the most used control signals for EEG-based BCIs. Classic P300-based BCIs work in a synchronous mode; the synchronous control assumes that the user is con...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/8/2/025025
更新日期:2011-04-01 00:00:00
abstract:OBJECTIVE:One of the main goals of brain-machine interface (BMI) research is to restore function to people with paralysis. Currently, multiple BMI design features are being investigated, based on various input modalities (externally applied and surgically implantable sensors) and output modalities (e.g. control of comp...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/12/4/043002
更新日期:2015-08-01 00:00:00
abstract:OBJECTIVE:Wireless control and power harvesting systems that operate injectable, cellular-scale optoelectronic components provide important demonstrated capabilities in neuromodulatory techniques such as optogenetics. Here, we report a radio frequency (RF) control/harvesting device that offers dramatically reduced size...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/12/5/056002
更新日期:2015-10-01 00:00:00
abstract:OBJECTIVE:Fractional calculus plays a key role in the analysis of neural dynamics. In particular, fractional calculus has been recently exploited for analyzing complex biological systems and capturing intrinsic phenomena. Also, artificial neural networks have been shown to have complex neuronal dynamics and characteris...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab8dd6
更新日期:2020-06-12 00:00:00
abstract:OBJECTIVE:Two-dimensional (2D) movement control is an important issue in brain-computer interfaces (BCIs) research because being able to move, for example, a cursor with the brain will enable patients with motor disabilities to control their environment. However, it is still a challenge to continuously control 2D movem...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/12/4/046021
更新日期:2015-08-01 00:00:00
abstract:OBJECTIVE:Patients with amyotrophic lateral sclerosis (ALS) may benefit from brain-computer interfaces (BCI), but the utility of such devices likely will have to account for the functional, cognitive, and behavioral heterogeneity of this neurodegenerative disorder. APPROACH:In this study, a heterogeneous group of pati...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/13/2/026002
更新日期:2016-04-01 00:00:00
abstract:OBJECTIVE:Low-intensity pulsed ultrasound stimulation (LIPUS) targeted to the mouse motor cortex can simultaneously induce local field potentials (LFPs) and electromyogram (EMG) responses. However, the functional coupling relationship between LFP and EMG signals has not been elucidated to date. This study aimed to inve...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab0879
更新日期:2019-04-01 00:00:00
abstract:OBJECTIVE:High-rate pulse trains have proven to be effective in cochlear prosthetics and, more recently, have been shown to elicit a wide range of interesting response properties in axons of the peripheral nervous system. Surprisingly, the effectiveness of such trains for use in retinal prostheses has not been explored...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/10/3/036009
更新日期:2013-06-01 00:00:00
abstract:OBJECTIVE:The past two decades have seen dramatic progress in our ability to model brain signals recorded by electroencephalography, functional near-infrared spectroscopy, etc., and to derive real-time estimates of user cognitive state, response, or intent for a variety of purposes: to restore communication by the seve...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/10/5/056014
更新日期:2013-10-01 00:00:00
abstract::Repositioning microelectrodes post-implantation is emerging as a promising approach to achieve long-term reliability in single neuronal recordings. The main goal of this study was to (a) assess glial reaction in response to movement of microelectrodes in the brain post-implantation and (b) determine an optimal window ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/6/4/046004
更新日期:2009-08-01 00:00:00
abstract:OBJECTIVE:Brains, like other physical devices, are inherently noisy. This source of variability is large, to the extent that internal noise often impacts human sensory processing more than externally induced (stimulus-driven) perturbations. Despite the fundamental nature of this phenomenon, its statistical distribution...
journal_title:Journal of neural engineering
pub_type: 杂志文章,随机对照试验
doi:10.1088/1741-2560/10/1/016014
更新日期:2013-02-01 00:00:00
abstract::All of the human prosthetic visual systems implanted so far have been achromatic. Schmidt et al. (1996) reported that at low stimulation intensities their subject reported that phosphenes usually had a specific hue, but when the stimulus intensity was increased, they desaturated to white. We speculate here that previo...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abd520
更新日期:2020-12-18 00:00:00
abstract:OBJECTIVE:Stability and selectivity are important when restoring long-term, functional sensory feedback in individuals with limb-loss. Our objective is to demonstrate a chronic, clinical neural stimulation system for providing selective sensory response in two upper-limb amputees. APPROACH:Multi-contact cuff electrode...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/12/2/026002
更新日期:2015-04-01 00:00:00
abstract:OBJECTIVE:Studies have shown that low frequency components of brain recordings provide information on voluntary hand movement directions. However, non-invasive techniques face more challenges compared to invasive techniques. APPROACH:This study presents a novel signal processing technique to extract features from non-...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/10/5/056018
更新日期:2013-10-01 00:00:00
abstract::The peripheral nerves of an amputee's residual limb still carry the information required to provide the robust, natural control signals needed to command a dexterous prosthetic limb. However, these signals are mixed in the volume conductor of the body and extracting them is an unmet challenge. A beamforming algorithm ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/8/5/056005
更新日期:2011-10-01 00:00:00
abstract:OBJECTIVE:Functions ascribed to the hippocampal sub-regions for encoding episodic memories include the separation of activity patterns propagated from the entorhinal cortex (EC) into the dentate gyrus (DG) and pattern completion in CA3 region. Since a direct assessment of these functions is lacking at the level of spec...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aabc20
更新日期:2018-08-01 00:00:00
abstract::The extraction of distinctly separable features from electroencephalogram (EEG) is one of the main challenges in designing a brain-computer interface (BCI). Existing feature extraction techniques for a BCI are mostly developed based on traditional signal processing techniques assuming that the signal is Gaussian and h...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/8/2/025014
更新日期:2011-04-01 00:00:00
abstract:OBJECTIVE:Analyzing and interpreting the activity of a heterogeneous population of neurons can be challenging, especially as the number of neurons, experimental trials, and experimental conditions increases. One approach is to extract a set of latent variables that succinctly captures the prominent co-fluctuation patte...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/10/6/066012
更新日期:2013-12-01 00:00:00
abstract::In this paper, we investigate the influence of hypercapnia on the dynamics of the phrenic neurogram in the piglet in two different age groups: 3-7 days (n = 11) and 10-16 days (n = 9). The phrenic neurogram was recorded from 17 piglets (3-16 days old) during control (40% O(2) with 3-5% end-tidal CO(2)), mild hypercapn...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/2/2/004
更新日期:2005-06-01 00:00:00
abstract:OBJECTIVE:The Subthalamic Nucleus (STN) is the most selected target for the placement of the Deep Brain Stimulation (DBS) electrode to treat Parkinson's disease. Its identification is a delicate and challenging task which is based on the interpretation of the STN functional activity acquired through microelectrode reco...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/abcb15
更新日期:2020-11-17 00:00:00
abstract:OBJECTIVE:Somatic symptom disorder (SSD) is a reflection of medically unexplained physical symptoms that lead to distress and impairment in social and occupational functioning. SSD is phenomenologically diagnosed and its neurobiology remains unsolved. APPROACH:In this study, we performed hyper-parameter optimized clas...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab50b2
更新日期:2019-12-16 00:00:00
abstract:OBJECTIVE:Haptic perception of a prosthetic limb or hand is a crucial, but often unmet, need which impacts the utility of the prostheses. In this study, we seek to evaluate the feasibility of a non-invasive transcutaneous nerve stimulation method in generating haptic feedback in a transradial amputee subject as well as...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aabd5d
更新日期:2018-08-01 00:00:00
abstract:OBJECTIVE:Real-time closed-loop neural feedback control requires the analysis of action potential traces within several milliseconds after they have been recorded from the brain. The current generation of spike clustering algorithms were mostly designed for off-line use and also require a significant amount of computat...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab208c
更新日期:2019-07-30 00:00:00
abstract::Current treatment concepts for epilepsy are based on continuous drug delivery or electrical stimulation to prevent the occurrence of seizures, exposing the brain and body to a mostly unneeded risk of adverse effects. To address the infrequent occurrence and short duration of epileptic seizures, intelligent implantable...
journal_title:Journal of neural engineering
pub_type: 杂志文章,评审
doi:10.1088/1741-2552/ab094a
更新日期:2019-08-01 00:00:00
abstract:OBJECTIVE:Brain-computer interfaces (BCIs) implemented with real-time functional magnetic resonance imaging (rt-fMRI) use fMRI time-courses from predefined regions of interest (ROIs). To reach best performances, localizer experiments and on-site expert supervision are required for ROI definition. To automate this step,...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/14/1/016004
更新日期:2017-02-01 00:00:00
abstract:OBJECTIVE:We consider the problem of optimal probing to learn connections in an evoked dynamic network. Such a network, in which each edge measures an input-output relationship between sites in sensor/actuator-space, is relevant to emerging applications in neural mapping and neural connectivity estimation. APPROACH:We...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2560/12/6/066011
更新日期:2015-12-01 00:00:00
abstract:OBJECTIVE:Artificial proprioceptive feedback from a myoelectric prosthesis is an important aspect in enhancing embodiment and user satisfaction, possibly lowering the demand for visual attention while controlling a prosthesis in everyday tasks. Contemporary myoelectric prostheses are advanced mechatronic systems with m...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aba4fd
更新日期:2020-08-14 00:00:00
abstract:OBJECTIVE:Intracortical brain-machine interfaces (iBMIs) aim to restore efficient communication and movement ability for paralyzed patients. However, frequent recalibration is required for consistency and reliability, and every recalibration will require relatively large most current sample set. The aim in this study i...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/aaa8a4
更新日期:2018-04-01 00:00:00
abstract:OBJECTIVE:A visual stimulator plays a vital part in brain-computer interfaces (BCIs) based on steady-state visual evoked potential (SSVEP). The properties of visual stimulation, such as frequency, color, and waveform, will influence SSVEP-based BCI performance to some extent. Recently, the computer monitor serves as a ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab2b7d
更新日期:2019-10-10 00:00:00
abstract:OBJECTIVE:Low-intensity transcranial ultrasound stimulation (TUS) is emerging as a non-invasive brain stimulation technique with superior spatial resolution and the ability to reach deep brain areas. Medical image-based computational modeling could be an important tool for individualized TUS dose control and targeting ...
journal_title:Journal of neural engineering
pub_type: 杂志文章
doi:10.1088/1741-2552/ab98dc
更新日期:2020-07-13 00:00:00