Progress in artificial vision through suprachoroidal retinal implants.

Abstract:

:Retinal implants have proven their ability to restore visual sensation to people with degenerative retinopathy, characterized by photoreceptor cell death and the retina's inability to sense light. Retinal bionics operate by electrically stimulating the surviving neurons in the retina, thus triggering the transfer of visual sensory information to the brain. Suprachoroidal implants were first investigated in Australia in the 1950s. In this approach, the neuromodulation hardware is positioned between the sclera and the choroid, thus providing significant surgical and safety benefits for patients, with the potential to maintain residual vision combined with the artificial input from the device. Here we review the latest advances and state of the art devices for suprachoroidal prostheses, highlight future technologies and discuss challenges and perspectives towards improved rehabilitation of vision.

journal_name

J Neural Eng

authors

Bareket L,Barriga-Rivera A,Zapf MP,Lovell NH,Suaning GJ

doi

10.1088/1741-2552/aa6cbb

subject

Has Abstract

pub_date

2017-08-01 00:00:00

pages

045002

issue

4

eissn

1741-2560

issn

1741-2552

journal_volume

14

pub_type

杂志文章,评审
  • Influence of proprioceptive feedback on the firing rate and recruitment of motoneurons.

    abstract::We investigated the relationships of the firing rate and maximal recruitment threshold of motoneurons recorded during isometric contraction with the number of spindles in individual muscles. At force levels above 10% of maximal voluntary contraction, the firing rate was inversely related to the number of spindles in a...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/1/016007

    authors: De Luca CJ,Kline JC

    更新日期:2012-02-01 00:00:00

  • Brain-computer interfacing under distraction: an evaluation study.

    abstract:OBJECTIVE:While motor-imagery based brain-computer interfaces (BCIs) have been studied over many years by now, most of these studies have taken place in controlled lab settings. Bringing BCI technology into everyday life is still one of the main challenges in this field of research. APPROACH:This paper systematically ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/5/056012

    authors: Brandl S,Frølich L,Höhne J,Müller KR,Samek W

    更新日期:2016-10-01 00:00:00

  • A framework for designing data-driven optimization systems for neural modulation.

    abstract:OBJECTIVE:Neural modulation is a fundamental tool for understanding and treating neurological and psychiatric diseases. However, due to the high-dimensional space, subject-specific responses, and variability within each subject, it is a major challenge to select the stimulation parameters that have the desired effect. ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd048

    authors: Connolly MJ,Park SE,Laxpati NG,Zaidi SA,Ghetiya M,Fernandez A,Gutekunst CA,Gross RE

    更新日期:2020-12-03 00:00:00

  • Low-intensity pulsed ultrasound modulates multi-frequency band phase synchronization between LFPs and EMG in mice.

    abstract:OBJECTIVE:Low-intensity pulsed ultrasound stimulation (LIPUS) targeted to the mouse motor cortex can simultaneously induce local field potentials (LFPs) and electromyogram (EMG) responses. However, the functional coupling relationship between LFP and EMG signals has not been elucidated to date. This study aimed to inve...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab0879

    authors: Wang Y,Xie P,Zhou S,Wang X,Yuan Y

    更新日期:2019-04-01 00:00:00

  • Pattern separation and completion of distinct axonal inputs transmitted via micro-tunnels between co-cultured hippocampal dentate, CA3, CA1 and entorhinal cortex networks.

    abstract:OBJECTIVE:Functions ascribed to the hippocampal sub-regions for encoding episodic memories include the separation of activity patterns propagated from the entorhinal cortex (EC) into the dentate gyrus (DG) and pattern completion in CA3 region. Since a direct assessment of these functions is lacking at the level of spec...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aabc20

    authors: Poli D,Wheeler BC,DeMarse TB,Brewer GJ

    更新日期:2018-08-01 00:00:00

  • In vivo two-photon microscopy reveals immediate microglial reaction to implantation of microelectrode through extension of processes.

    abstract:OBJECTIVE:Penetrating cortical neural probe technologies allow investigators to record electrical signals in the brain. Implantation of probes results in acute tissue damage, and microglia density increases around implanted devices over weeks. However, the mechanisms underlying this encapsulation are not well understoo...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/6/066001

    authors: Kozai TD,Vazquez AL,Weaver CL,Kim SG,Cui XT

    更新日期:2012-12-01 00:00:00

  • In vivo polymerization of poly(3,4-ethylenedioxythiophene) in the living rat hippocampus does not cause a significant loss of performance in a delayed alternation task.

    abstract::After extended implantation times, traditional intracortical neural probes exhibit a foreign-body reaction characterized by a reactive glial sheath that has been associated with increased system impedance and signal deterioration. Previously, we have proposed that the local in vivo polymerization of an electronically ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/2/026005

    authors: Ouyang L,Shaw CL,Kuo CC,Griffin AL,Martin DC

    更新日期:2014-04-01 00:00:00

  • Interleaved intramuscular stimulation with minimally overlapping electrodes evokes smooth and fatigue resistant forces.

    abstract:OBJECTIVE:It is known that multi-site interleaved stimulation generates less muscle fatigue compared to single-site synchronous stimulation. However, in the limited number of studies in which intramuscular electrodes were used, the fatigue reduction associated with interleaved stimulation could not consistently be achi...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aba99e

    authors: Eladly A,Del Valle J,Minguillon J,Mercadal B,Becerra-Fajardo L,Navarro X,Ivorra A

    更新日期:2020-08-25 00:00:00

  • Rehabilitation regimes based upon psychophysical studies of prosthetic vision.

    abstract::Human trials of prototype visual prostheses have successfully elicited visual percepts (phosphenes) in the visual field of implant recipients blinded through retinitis pigmentosa and age-related macular degeneration. Researchers are progressing rapidly towards a device that utilizes individual phosphenes as the elemen...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2560/6/3/035009

    authors: Chen SC,Suaning GJ,Morley JW,Lovell NH

    更新日期:2009-06-01 00:00:00

  • Integrated circuit amplifiers for multi-electrode intracortical recording.

    abstract::Significant progress has been made in systems that interpret the electrical signals of the brain in order to control an actuator. One version of these systems senses neuronal extracellular action potentials with an array of up to 100 miniature probes inserted into the cortex. The impedance of each probe is high, so en...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2560/6/1/012001

    authors: Jochum T,Denison T,Wolf P

    更新日期:2009-02-01 00:00:00

  • Electroencephalographic (EEG) control of three-dimensional movement.

    abstract::Brain-computer interfaces (BCIs) can use brain signals from the scalp (EEG), the cortical surface (ECoG), or within the cortex to restore movement control to people who are paralyzed. Like muscle-based skills, BCIs' use requires activity-dependent adaptations in the brain that maintain stable relationships between the...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/7/3/036007

    authors: McFarland DJ,Sarnacki WA,Wolpaw JR

    更新日期:2010-06-01 00:00:00

  • Object stiffness recognition using haptic feedback delivered through transcutaneous proximal nerve stimulation.

    abstract:OBJECTIVE:Haptic feedback is crucial when we manipulate objects. Information pertaining to an object's stiffness in particular can help facilitate fine motor control. In this study, we seek to determine whether objects of different stiffness levels can be recognized using haptic feedback provided by transcutaneous elec...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab4d99

    authors: Vargas L,Shin H,Huang HH,Zhu Y,Hu X

    更新日期:2019-12-05 00:00:00

  • Constant pressure fluid infusion into rat neocortex from implantable microfluidic devices.

    abstract::Implantable electrode arrays capable of recording and stimulating neural activity with high spatial and temporal resolution will provide a foundation for future brain computer interface technology. Currently, their clinical impact has been curtailed by a general lack of functional stability, which can be attributed to...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/5/4/003

    authors: Retterer ST,Smith KL,Bjornsson CS,Turner JN,Isaacson MS,Shain W

    更新日期:2008-12-01 00:00:00

  • Amplitude versus spatially modulated electrotactile feedback for myoelectric control of two degrees of freedom.

    abstract:OBJECTIVE:Artificial proprioceptive feedback from a myoelectric prosthesis is an important aspect in enhancing embodiment and user satisfaction, possibly lowering the demand for visual attention while controlling a prosthesis in everyday tasks. Contemporary myoelectric prostheses are advanced mechatronic systems with m...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aba4fd

    authors: Garenfeld MA,Mortensen CK,Strbac M,Dideriksen JL,Dosen S

    更新日期:2020-08-14 00:00:00

  • Multiband tangent space mapping and feature selection for classification of EEG during motor imagery.

    abstract:OBJECTIVE:When designing multiclass motor imagery-based brain-computer interface (MI-BCI), a so-called tangent space mapping (TSM) method utilizing the geometric structure of covariance matrices is an effective technique. This paper aims to introduce a method using TSM for finding accurate operational frequency bands r...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aac313

    authors: Islam MR,Tanaka T,Molla MKI

    更新日期:2018-08-01 00:00:00

  • Ultraminiaturized photovoltaic and radio frequency powered optoelectronic systems for wireless optogenetics.

    abstract:OBJECTIVE:Wireless control and power harvesting systems that operate injectable, cellular-scale optoelectronic components provide important demonstrated capabilities in neuromodulatory techniques such as optogenetics. Here, we report a radio frequency (RF) control/harvesting device that offers dramatically reduced size...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/5/056002

    authors: Park SI,Shin G,Banks A,McCall JG,Siuda ER,Schmidt MJ,Chung HU,Noh KN,Mun JG,Rhodes J,Bruchas MR,Rogers JA

    更新日期:2015-10-01 00:00:00

  • Within-socket myoelectric prediction of continuous ankle kinematics for control of a powered transtibial prosthesis.

    abstract:OBJECTIVE:Powered robotic prostheses create a need for natural-feeling user interfaces and robust control schemes. Here, we examined the ability of a nonlinear autoregressive model to continuously map the kinematics of a transtibial prosthesis and electromyographic (EMG) activity recorded within socket to the future es...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/5/056027

    authors: Farmer S,Silver-Thorn S,Voglewede P,Beardsley SA

    更新日期:2014-10-01 00:00:00

  • Consistency of quantitative electroencephalography features in a large clinical data set.

    abstract:OBJECTIVE:Despite their increasing use and public health importance, little is known about the consistency and variability of the quantitative features of baseline electroencephalography (EEG) measurements in healthy individuals and populations. This study aims to investigate population consistency of EEG features. AP...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab4af3

    authors: Nahmias DO,Kontson KL,Soltysik DA,Civillico EF

    更新日期:2019-11-12 00:00:00

  • Impact of referencing scheme on decoding performance of LFP-based brain-machine interface.

    abstract:OBJECTIVE:There has recently been an increasing interest in local field potential (LFP) for brain-machine interface (BMI) applications due to its desirable properties (signal stability and low bandwidth). LFP is typically recorded with respect to a single unipolar reference which is susceptible to common noise. Several...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abce3c

    authors: Ahmadi N,Constandinou T,Bouganis CS

    更新日期:2020-11-26 00:00:00

  • Transducer modeling for accurate acoustic simulations of transcranial focused ultrasound stimulation.

    abstract:OBJECTIVE:Low-intensity transcranial ultrasound stimulation (TUS) is emerging as a non-invasive brain stimulation technique with superior spatial resolution and the ability to reach deep brain areas. Medical image-based computational modeling could be an important tool for individualized TUS dose control and targeting ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab98dc

    authors: Pasquinelli C,Montanaro H,Lee HJ,Hanson LG,Kim H,Kuster N,Siebner HR,Neufeld E,Thielscher A

    更新日期:2020-07-13 00:00:00

  • Functional vagotopy in the cervical vagus nerve of the domestic pig: implications for the study of vagus nerve stimulation.

    abstract:OBJECTIVE:Given current clinical interest in vagus nerve stimulation (VNS), there are surprisingly few studies characterizing the anatomy of the vagus nerve in large animal models as it pertains to on-and off-target engagement of local fibers. We sought to address this gap by evaluating vagal anatomy in the pig, whose ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab7ad4

    authors: Settell ML,Pelot NA,Knudsen BE,Dingle AM,McConico AL,Nicolai EN,Trevathan JK,Ezzell JA,Ross EK,Gustafson KJ,Shoffstall AJ,Williams JC,Zeng W,Poore SO,Populin LC,Suminski AJ,Grill WM,Ludwig KA

    更新日期:2020-04-09 00:00:00

  • Force estimation from ensembles of Golgi tendon organs.

    abstract::Golgi tendon organs (GTOs) located in the skeletal muscles provide the central nervous system with information about muscle tension. The ensemble firing of all GTO receptors in the muscle has been hypothesized to represent a reliable measure of the whole muscle force but the precision and accuracy of that information ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/6/3/036001

    authors: Mileusnic MP,Loeb GE

    更新日期:2009-06-01 00:00:00

  • Autoencoders for learning template spectrograms in electrocorticographic signals.

    abstract:OBJECTIVE:Electrocorticography (ECoG) based studies generally analyze features from specific frequency bands selected by manual evaluation of spectral power. However, the definition of these features can vary across subjects, cortical areas, tasks and across time for a given subject. We propose an autoencoder based app...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaf13f

    authors: Pailla T,Miller KJ,Gilja V

    更新日期:2019-02-01 00:00:00

  • Comment on 'fast attainment of computer cursor control with noninvasively acquired brain signals'.

    abstract::In a recent paper by Bradberry, Gentili and Contreras-Vidal published in Journal of Neural Engineering (2011, 8 036010), an interesting method for the control of a two-dimensional mouse cursor was proposed, which apparently attained excellent control and good speed with relatively simple techniques. We believe some of...

    journal_title:Journal of neural engineering

    pub_type: 评论,杂志文章

    doi:10.1088/1741-2560/8/5/058001

    authors: Poli R,Salvaris M

    更新日期:2011-10-01 00:00:00

  • Analysis of spontaneous MEG activity in mild cognitive impairment and Alzheimer's disease using spectral entropies and statistical complexity measures.

    abstract::Alzheimer's disease (AD) is the most common cause of dementia. Over the last few years, a considerable effort has been devoted to exploring new biomarkers. Nevertheless, a better understanding of brain dynamics is still required to optimize therapeutic strategies. In this regard, the characterization of mild cognitive...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/3/036007

    authors: Bruña R,Poza J,Gómez C,García M,Fernández A,Hornero R

    更新日期:2012-06-01 00:00:00

  • Different classification techniques considering brain computer interface applications.

    abstract::In this work the application of different machine learning techniques for classification of mental tasks from electroencephalograph (EEG) signals is investigated. The main application for this research is the improvement of brain computer interface (BCI) systems. For this purpose, Bayesian graphical network, neural ne...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/3/2/008

    authors: Rezaei S,Tavakolian K,Nasrabadi AM,Setarehdan SK

    更新日期:2006-06-01 00:00:00

  • Open Ephys electroencephalography (Open Ephys  +  EEG): a modular, low-cost, open-source solution to human neural recording.

    abstract:OBJECTIVE:Electroencephalography (EEG) offers a unique opportunity to study human neural activity non-invasively with millisecond resolution using minimal equipment in or outside of a lab setting. EEG can be combined with a number of techniques for closed-loop experiments, where external devices are driven by specific ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa651f

    authors: Black C,Voigts J,Agrawal U,Ladow M,Santoyo J,Moore C,Jones S

    更新日期:2017-06-01 00:00:00

  • Performance predictors of brain-computer interfaces in patients with amyotrophic lateral sclerosis.

    abstract:OBJECTIVE:Patients with amyotrophic lateral sclerosis (ALS) may benefit from brain-computer interfaces (BCI), but the utility of such devices likely will have to account for the functional, cognitive, and behavioral heterogeneity of this neurodegenerative disorder. APPROACH:In this study, a heterogeneous group of pati...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/2/026002

    authors: Geronimo A,Simmons Z,Schiff SJ

    更新日期:2016-04-01 00:00:00

  • Towards a ternary NIRS-BCI: single-trial classification of verbal fluency task, Stroop task and unconstrained rest.

    abstract:OBJECTIVE:The majority of near-infrared spectroscopy (NIRS) brain-computer interface (BCI) studies have investigated binary classification problems. Limited work has considered differentiation of more than two mental states, or multi-class differentiation of higher-level cognitive tasks using measurements outside of th...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/6/066008

    authors: C Schudlo L,Chau T

    更新日期:2015-12-01 00:00:00

  • Comparison of spike sorting and thresholding of voltage waveforms for intracortical brain-machine interface performance.

    abstract:OBJECTIVE:For intracortical brain-machine interfaces (BMIs), action potential voltage waveforms are often sorted to separate out individual neurons. If these neurons contain independent tuning information, this process could increase BMI performance. However, the sorting of action potentials ('spikes') requires high sa...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/1/016009

    authors: Christie BP,Tat DM,Irwin ZT,Gilja V,Nuyujukian P,Foster JD,Ryu SI,Shenoy KV,Thompson DE,Chestek CA

    更新日期:2015-02-01 00:00:00