Corrigendum: Tissue-engineered nerve grafts using a scaffold-independent and injectable drug delivery system: a novel design with translational advantages (2019 J. Neural Eng. 16 036030).

Abstract:

OBJECTIVE:Currently commercially available nerve conduits have demonstrated suboptimal clinical efficacy in repairing peripheral nerve defects. Although tissue-engineered nerve grafts (TENGs) with sustained release of neurotrophic factors (NTFs) are experimentally proved to be more effective than these blank conduits, there remains a lack of clinical translation. NTFs are typically immobilized onto scaffold materials of the conduit via adsorption, specific binding or other incorporation techniques. These scaffold-based delivery strategies increase complexity and cost of conduit fabrication and lack flexibility in choosing different drugs. Therefore, to facilitate clinical translation and commercialization, we construct a TENG using a scaffold-independent drug delivery system (DDS). APPROACH:This study adopted a scaffold-independent DDS based on methoxy-poly (ethylene glycol)-b-poly(γ-ethyl-Lglutamate) (mPEG-PELG) thermosensitive hydrogels that undergo sol-to-gel transition at body temperature. In addition, TENG, a chitosan scaffold filled with nerve growth factor (NGF)-loaded mPEG-PELG that gel in the lumen upon injection during surgery and function as a drug-releasing conduit-filler, was designed. Subsequently, the efficacy of DDS and therapeutic effects of TENG were assessed. MAIN RESULTS:The results demonstrated that NGFloaded mPEG-PELG controllably and sustainably released bioactive NGF for 28 d. When bridging a 10 mm rat sciatic nerve gap, the morphological, electrophysiological, and functional analyses revealed that NGF-releasing TENG (Scaffold + NGF/mPEG-PELG) achieved superior regenerative outcomes compared to plain scaffolds and those combined with systemic delivery of NGF (daily intramuscular injection (IM)), and its effects were relatively similar to autografts. SIGNIFICANCE:This study has proposed a TENG using thermosensitive hydrogels as an injectable implant to controllably release NGF, which has promising therapeutic potential and translatability. Such TENGs obviate the need for conduit modification, complex preloading or binding mediators, therefore they allow the ease of drug switching in clinical practice and greatly simplify the manufacturing process due to the independent preparation of drug delivery system.

journal_name

J Neural Eng

authors

Liu Y,Yu S,Gu X,Cao R,Cui S

doi

10.1088/1741-2552/abd1ec

subject

Has Abstract

pub_date

2020-12-09 00:00:00

eissn

1741-2560

issn

1741-2552

pub_type

杂志文章
  • Integrated circuit amplifiers for multi-electrode intracortical recording.

    abstract::Significant progress has been made in systems that interpret the electrical signals of the brain in order to control an actuator. One version of these systems senses neuronal extracellular action potentials with an array of up to 100 miniature probes inserted into the cortex. The impedance of each probe is high, so en...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2560/6/1/012001

    authors: Jochum T,Denison T,Wolf P

    更新日期:2009-02-01 00:00:00

  • Progress in artificial vision through suprachoroidal retinal implants.

    abstract::Retinal implants have proven their ability to restore visual sensation to people with degenerative retinopathy, characterized by photoreceptor cell death and the retina's inability to sense light. Retinal bionics operate by electrically stimulating the surviving neurons in the retina, thus triggering the transfer of v...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2552/aa6cbb

    authors: Bareket L,Barriga-Rivera A,Zapf MP,Lovell NH,Suaning GJ

    更新日期:2017-08-01 00:00:00

  • DataHigh: graphical user interface for visualizing and interacting with high-dimensional neural activity.

    abstract:OBJECTIVE:Analyzing and interpreting the activity of a heterogeneous population of neurons can be challenging, especially as the number of neurons, experimental trials, and experimental conditions increases. One approach is to extract a set of latent variables that succinctly captures the prominent co-fluctuation patte...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/6/066012

    authors: Cowley BR,Kaufman MT,Butler ZS,Churchland MM,Ryu SI,Shenoy KV,Yu BM

    更新日期:2013-12-01 00:00:00

  • Spatial channel interactions in cochlear implants.

    abstract::The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies g...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/4/046029

    authors: Tang Q,Benítez R,Zeng FG

    更新日期:2011-08-01 00:00:00

  • Evaluation of probabilistic methods to predict muscle activity: implications for neuroprosthetics.

    abstract::Functional electrical stimulation (FES) involves artificial activation of muscles with surface or implanted electrodes to restore motor function in paralyzed individuals. Currently, FES-based prostheses produce only a limited range of movements due to the difficulty associated with identifying patterns of muscle activ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/6/5/055008

    authors: Johnson LA,Fuglevand AJ

    更新日期:2009-10-01 00:00:00

  • Responses of rabbit retinal ganglion cells to electrical stimulation with an epiretinal electrode.

    abstract::Rational selection of electrical stimulus parameters for an electronic retinal prosthesis requires knowledge of the electrophysiological responses of retinal neurons to electrical stimuli. In this study, we examined the effects of cathodal and anodal current pulses on the extracellularly recorded responses of OFF and ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/2/1/003

    authors: Jensen RJ,Ziv OR,Rizzo JF

    更新日期:2005-03-01 00:00:00

  • Towards a hemodynamic BCI using transcranial Doppler without user-specific training data.

    abstract:UNLABELLED:Transcranial Doppler (TCD) was recently introduced as a new brain-computer interface (BCI) modality for detecting task-induced hemispheric lateralization. To date, single-trial discrimination between a lateralized mental activity and a rest state has been demonstrated with long (45 s) activation time periods...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/1/016005

    authors: Aleem I,Chau T

    更新日期:2013-02-01 00:00:00

  • Ensembles of adaptive spatial filters increase BCI performance: an online evaluation.

    abstract:OBJECTIVE:In electroencephalographic (EEG) data, signals from distinct sources within the brain are widely spread by volume conduction and superimposed such that sensors receive mixtures of a multitude of signals. This reduction of spatial information strongly hampers single-trial analysis of EEG data as, for example, ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/4/046003

    authors: Sannelli C,Vidaurre C,Müller KR,Blankertz B

    更新日期:2016-08-01 00:00:00

  • Control of a humanoid robot by a noninvasive brain-computer interface in humans.

    abstract::We describe a brain-computer interface for controlling a humanoid robot directly using brain signals obtained non-invasively from the scalp through electroencephalography (EEG). EEG has previously been used for tasks such as controlling a cursor and spelling a word, but it has been regarded as an unlikely candidate fo...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/5/2/012

    authors: Bell CJ,Shenoy P,Chalodhorn R,Rao RP

    更新日期:2008-06-01 00:00:00

  • Applying dynamic data collection to improve dry electrode system performance for a P300-based brain-computer interface.

    abstract:OBJECTIVE:Dry electrodes have an advantage over gel-based 'wet' electrodes by providing quicker set-up time for electroencephalography recording; however, the potentially poorer contact can result in noisier recordings. We examine the impact that this may have on brain-computer interface communication and potential app...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/6/066018

    authors: Clements JM,Sellers EW,Ryan DB,Caves K,Collins LM,Throckmorton CS

    更新日期:2016-12-01 00:00:00

  • Chronic cortical and electromyographic recordings from a fully implantable device: preclinical experience in a nonhuman primate.

    abstract:OBJECTIVE:Analysis of intra- and perioperatively recorded cortical and basal ganglia local field potentials in human movement disorders has provided great insight into the pathophysiology of diseases such as Parkinson's, dystonia, and essential tremor. However, in order to better understand the network abnormalities an...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/1/016009

    authors: Ryapolova-Webb E,Afshar P,Stanslaski S,Denison T,de Hemptinne C,Bankiewicz K,Starr PA

    更新日期:2014-02-01 00:00:00

  • Adaptive neuron-to-EMG decoder training for FES neuroprostheses.

    abstract:OBJECTIVE:We have previously demonstrated a brain-machine interface neuroprosthetic system that provided continuous control of functional electrical stimulation (FES) and restoration of grasp in a primate model of spinal cord injury (SCI). Predicting intended EMG directly from cortical recordings provides a flexible hi...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/13/4/046009

    authors: Ethier C,Acuna D,Solla SA,Miller LE

    更新日期:2016-08-01 00:00:00

  • EEG classification of imagined syllable rhythm using Hilbert spectrum methods.

    abstract::We conducted an experiment to determine whether the rhythm with which imagined syllables are produced may be decoded from EEG recordings. High density EEG data were recorded for seven subjects while they produced in imagination one of two syllables in one of three different rhythms. We used a modified second-order bli...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/7/4/046006

    authors: Deng S,Srinivasan R,Lappas T,D'Zmura M

    更新日期:2010-08-01 00:00:00

  • EEG representation using multi-instance framework on the manifold of symmetric positive definite matrices.

    abstract:OBJECTIVE:The generalization and robustness of an electroencephalogram (EEG)-based system are crucial requirements in actual practices. APPROACH:To reach these goals, we propose a new EEG representation that provides a more realistic view of brain functionality by applying multi-instance (MI) framework to consider the...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab0dad

    authors: Sadatnejad K,Rahmati M,Rostami R,Kazemi R,Ghidary SS,Müller A,Alimardani F

    更新日期:2019-06-01 00:00:00

  • Improving an open-source commercial system to reliably perform activity-dependent stimulation.

    abstract:OBJECTIVE:Activity-dependent stimulation (ADS) is designed to strengthen the connections between neuronal circuits and therefore may be a promising tool for promoting neurophysiological reorganization following a brain injury. To successfully perform this technique, two criteria must be met: (1) spikes in the extracell...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab3319

    authors: Murphy M,Buccelli S,Bornat Y,Bundy D,Nudo R,Guggenmos D,Chiappalone M

    更新日期:2019-10-29 00:00:00

  • Autoencoders for learning template spectrograms in electrocorticographic signals.

    abstract:OBJECTIVE:Electrocorticography (ECoG) based studies generally analyze features from specific frequency bands selected by manual evaluation of spectral power. However, the definition of these features can vary across subjects, cortical areas, tasks and across time for a given subject. We propose an autoencoder based app...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaf13f

    authors: Pailla T,Miller KJ,Gilja V

    更新日期:2019-02-01 00:00:00

  • Modeling deep brain stimulation: point source approximation versus realistic representation of the electrode.

    abstract::Deep brain stimulation (DBS) has emerged as an effective treatment for movement disorders; however, the fundamental mechanisms by which DBS works are not well understood. Computational models of DBS can provide insights into these fundamental mechanisms and typically require two steps: calculation of the electrical po...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/7/6/066009

    authors: Zhang TC,Grill WM

    更新日期:2010-12-01 00:00:00

  • Corrosion of silicon integrated circuits and lifetime predictions in implantable electronic devices.

    abstract::Corrosion is a prime concern for active implantable devices. In this paper we review the principles underlying the concepts of hermetic packages and encapsulation, used to protect implanted electronics, some of which remain widely overlooked. We discuss how technological advances have created a need to update the way ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2560/10/3/031002

    authors: Vanhoestenberghe A,Donaldson N

    更新日期:2013-06-01 00:00:00

  • Seizure entrainment with polarizing low-frequency electric fields in a chronic animal epilepsy model.

    abstract::Neural activity can be modulated by applying a polarizing low-frequency (<100 Hz) electric field (PLEF). Unlike conventional pulsed stimulation, PLEF stimulation has a graded, modulatory effect on neuronal excitability, and permits the simultaneous recording of neuronal activity during stimulation suitable for continu...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/6/4/046009

    authors: Sunderam S,Chernyy N,Peixoto N,Mason JP,Weinstein SL,Schiff SJ,Gluckman BJ

    更新日期:2009-08-01 00:00:00

  • A framework for designing data-driven optimization systems for neural modulation.

    abstract:OBJECTIVE:Neural modulation is a fundamental tool for understanding and treating neurological and psychiatric diseases. However, due to the high-dimensional space, subject-specific responses, and variability within each subject, it is a major challenge to select the stimulation parameters that have the desired effect. ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd048

    authors: Connolly MJ,Park SE,Laxpati NG,Zaidi SA,Ghetiya M,Fernandez A,Gutekunst CA,Gross RE

    更新日期:2020-12-03 00:00:00

  • Ultraminiaturized photovoltaic and radio frequency powered optoelectronic systems for wireless optogenetics.

    abstract:OBJECTIVE:Wireless control and power harvesting systems that operate injectable, cellular-scale optoelectronic components provide important demonstrated capabilities in neuromodulatory techniques such as optogenetics. Here, we report a radio frequency (RF) control/harvesting device that offers dramatically reduced size...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/5/056002

    authors: Park SI,Shin G,Banks A,McCall JG,Siuda ER,Schmidt MJ,Chung HU,Noh KN,Mun JG,Rhodes J,Bruchas MR,Rogers JA

    更新日期:2015-10-01 00:00:00

  • The response of retinal neurons to high-frequency stimulation.

    abstract:OBJECTIVE:High-rate pulse trains have proven to be effective in cochlear prosthetics and, more recently, have been shown to elicit a wide range of interesting response properties in axons of the peripheral nervous system. Surprisingly, the effectiveness of such trains for use in retinal prostheses has not been explored...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/3/036009

    authors: Cai C,Twyford P,Fried S

    更新日期:2013-06-01 00:00:00

  • Impact of referencing scheme on decoding performance of LFP-based brain-machine interface.

    abstract:OBJECTIVE:There has recently been an increasing interest in local field potential (LFP) for brain-machine interface (BMI) applications due to its desirable properties (signal stability and low bandwidth). LFP is typically recorded with respect to a single unipolar reference which is susceptible to common noise. Several...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abce3c

    authors: Ahmadi N,Constandinou T,Bouganis CS

    更新日期:2020-11-26 00:00:00

  • A high-density carbon fiber neural recording array technology.

    abstract:OBJECTIVE:Microwire and Utah-style neural recording arrays are the predominant devices used for cortical neural recording, but the implanted electrodes cause a significant adverse biological response and suffer from well-studied performance degradation. Recent work has demonstrated that carbon fiber electrodes do not e...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aae8d9

    authors: Massey TL,Santacruz SR,Hou JF,Pister KSJ,Carmena JM,Maharbiz MM

    更新日期:2019-02-01 00:00:00

  • Dynamics and coupling of fractional-order models of the motor cortex and central pattern generators.

    abstract:OBJECTIVE:Fractional calculus plays a key role in the analysis of neural dynamics. In particular, fractional calculus has been recently exploited for analyzing complex biological systems and capturing intrinsic phenomena. Also, artificial neural networks have been shown to have complex neuronal dynamics and characteris...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab8dd6

    authors: Lu Q

    更新日期:2020-06-12 00:00:00

  • Evaluation of windowing techniques for intramuscular EMG-based diagnostic, rehabilitative and assistive devices.

    abstract:OBJECTIVE:Intramuscular electromyography (iEMG) signals, non-invasively recorded, directly from the muscles are used to diagnose various neuromuscular disorders/diseases, also to control rehabilitative and assistive robotic devices. iEMG signals are being potentially used in neurology, kinesiology, rehabilitation, and ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abcc7f

    authors: Ashraf H,Waris A,Gilani SO,Kashif AS,Jamil M,Jochumsen M,Niazi IK

    更新日期:2020-11-20 00:00:00

  • The noise and impedance of microelectrodes.

    abstract:OBJECTIVE:While the positive correlation between impedance and noise of microelectrodes is well known, their quantitative relationship is too rarely described. Knowledge of this relationship provides useful information for both microsystems engineers and electrophysiologists. APPROACH:We discuss the physical basis of ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abb3b4

    authors: Mierzejewski M,Steins H,Kshirsagar P,Jones PD

    更新日期:2020-10-15 00:00:00

  • Electrophysiology-based detection of emergency braking intention in real-world driving.

    abstract:OBJECTIVE:The fact that all human action is preceded by brain processes partially observable through neuroimaging devices such as electroencephalography (EEG) is currently being explored in a number of applications. A recent study by Haufe et al (2011 J. Neural Eng. 8 056001) demonstrates the possibility of performing ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/5/056011

    authors: Haufe S,Kim JW,Kim IH,Sonnleitner A,Schrauf M,Curio G,Blankertz B

    更新日期:2014-10-01 00:00:00

  • 3D Parylene sheath neural probe for chronic recordings.

    abstract:OBJECTIVE:Reliable chronic recordings from implanted neural probes remain a significant challenge; current silicon-based and microwire technologies experience a wide range of biotic and abiotic failure modes contributing to loss of signal quality. APPROACH:A multi-prong alternative strategy with potential to overcome ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/4/045002

    authors: Kim BJ,Kuo JT,Hara SA,Lee CD,Yu L,Gutierrez CA,Hoang TQ,Pikov V,Meng E

    更新日期:2013-08-01 00:00:00

  • Understanding ultrasound neuromodulation using a computationally efficient and interpretable model of intramembrane cavitation.

    abstract:OBJECTIVE:Low-intensity focused ultrasound stimulation (LIFUS) emerges as an attracting technology for noninvasive modulation of neural circuits, yet the underlying action mechanisms remain unclear. The neuronal intramembrane cavitation excitation (NICE) model suggests that LIFUS excites neurons through a complex inter...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab1685

    authors: Lemaire T,Neufeld E,Kuster N,Micera S

    更新日期:2019-08-01 00:00:00