Machine learning validation of EEG+tACS artefact removal.

Abstract:

OBJECTIVE:Electroencephalography (EEG) recorded during transcranial alternating current simulation (tACS) is highly desirable in order to investigate brain dynamics during stimulation, but is corrupted by large amplitude stimulation artefacts. Artefact removal algorithms have been presented previously, but with substantial debates on their performance, utility, and the presence of any residual artefacts. This paper investigates whether machine learning can be used to validate artefact removal algorithms. The postulation is that residual artefacts in the EEG after cleaning would be independent of the experiment performed, making it impossible to differentiate between different parts of an EEG+tACS experiment, or between different behavioural tasks performed. APPROACH:Ten participates undertook two tasks (nBack and backwards digital recall) during simultaneous EEG+tACS, exercising different aspects of working memory. Stimulations during no task and sham conditions were also performed. A previously reported tACS artefact removal algorithm from our group was used to clean the EEG and a linear discriminant analysis was trained on the cleaned EEG to differentiate different parts of the experiment. MAIN RESULTS:Baseline, baseline during tACS, working memory task without tACS, and working memory task with tACS data segments could be differentiated with accuracies ranging from 65%-94%, far exceeding chance levels. EEG from the nBack and backwards digital recall tasks could be separated during stimulation, with an accuracy exceeding 72%. If residual tACS artefacts remained after the EEG cleaning these did not dominate the classification process. SIGNIFICANCE:This helps in building confidence that true EEG information is present after artefact removal. Our methodology presents a new approach to validating tACS artefact removal approaches.

journal_name

J Neural Eng

authors

Kohli S,Casson AJ

doi

10.1088/1741-2552/ab58a3

subject

Has Abstract

pub_date

2020-01-24 00:00:00

pages

016034

issue

1

eissn

1741-2560

issn

1741-2552

journal_volume

17

pub_type

杂志文章
  • Autoencoders for learning template spectrograms in electrocorticographic signals.

    abstract:OBJECTIVE:Electrocorticography (ECoG) based studies generally analyze features from specific frequency bands selected by manual evaluation of spectral power. However, the definition of these features can vary across subjects, cortical areas, tasks and across time for a given subject. We propose an autoencoder based app...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaf13f

    authors: Pailla T,Miller KJ,Gilja V

    更新日期:2019-02-01 00:00:00

  • Brain-computer interface based on intermodulation frequency.

    abstract:OBJECTIVE:Most recent steady-state visual evoked potential (SSVEP)-based brain-computer interface (BCI) systems have used a single frequency for each target, so that a large number of targets require a large number of stimulus frequencies and therefore a wider frequency band. However, human beings show good SSVEP respo...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/10/6/066009

    authors: Chen X,Chen Z,Gao S,Gao X

    更新日期:2013-12-01 00:00:00

  • Electrode modifications to lower electrode impedance and improve neural signal recording sensitivity.

    abstract:OBJECTIVE:Although electrode size should be miniaturized to provide higher selectivity for neural signal recording and to avoid tissue damage, small sized electrodes induce high impedance, which decreases recording quality. In this work, the electrode surface was modified to increase the effective surface area to lower...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/5/056018

    authors: Chung T,Wang JQ,Wang J,Cao B,Li Y,Pang SW

    更新日期:2015-10-01 00:00:00

  • Within-socket myoelectric prediction of continuous ankle kinematics for control of a powered transtibial prosthesis.

    abstract:OBJECTIVE:Powered robotic prostheses create a need for natural-feeling user interfaces and robust control schemes. Here, we examined the ability of a nonlinear autoregressive model to continuously map the kinematics of a transtibial prosthesis and electromyographic (EMG) activity recorded within socket to the future es...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/5/056027

    authors: Farmer S,Silver-Thorn S,Voglewede P,Beardsley SA

    更新日期:2014-10-01 00:00:00

  • Design of optimal multi-site brain stimulation protocols via neuro-inspired epilepsy models for abatement of interictal discharges.

    abstract:BACKGROUND:Electrical brain stimulation is recognized as a promising therapeutic approach for treating brain disorders such as epilepsy. However, the use of this technique is still largely empirical, since stimulation parameters and targets are chosen using a trial-and-error approach. Therefore, there is a pressing nee...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd049

    authors: Arrais M,Modolo J,Mogul D,Wendling F

    更新日期:2020-12-03 00:00:00

  • Towards a symbiotic brain-computer interface: exploring the application-decoder interaction.

    abstract:OBJECTIVE:State of the art brain-computer interface (BCI) research focuses on improving individual components such as the application or the decoder that converts the user's brain activity to control signals. In this study, we investigate the interaction between these components in the P300 speller, a BCI for communica...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/6/066027

    authors: Verhoeven T,Buteneers P,Wiersema JR,Dambre J,Kindermans PJ

    更新日期:2015-12-01 00:00:00

  • Stability and selectivity of a chronic, multi-contact cuff electrode for sensory stimulation in human amputees.

    abstract:OBJECTIVE:Stability and selectivity are important when restoring long-term, functional sensory feedback in individuals with limb-loss. Our objective is to demonstrate a chronic, clinical neural stimulation system for providing selective sensory response in two upper-limb amputees. APPROACH:Multi-contact cuff electrode...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/2/026002

    authors: Tan DW,Schiefer MA,Keith MW,Anderson JR,Tyler DJ

    更新日期:2015-04-01 00:00:00

  • Myoelectric control with abstract decoders.

    abstract:OBJECTIVE:The objective of this study was to compare the use of muscles appropriate for partial-hand prostheses with those typically used for complete hand devices and to determine whether differences in their underlying neural substrates translate to different levels of myoelectric control. APPROACH:We developed a no...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aacbfe

    authors: Dyson M,Barnes J,Nazarpour K

    更新日期:2018-10-01 00:00:00

  • In vivo polymerization of poly(3,4-ethylenedioxythiophene) in the living rat hippocampus does not cause a significant loss of performance in a delayed alternation task.

    abstract::After extended implantation times, traditional intracortical neural probes exhibit a foreign-body reaction characterized by a reactive glial sheath that has been associated with increased system impedance and signal deterioration. Previously, we have proposed that the local in vivo polymerization of an electronically ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/11/2/026005

    authors: Ouyang L,Shaw CL,Kuo CC,Griffin AL,Martin DC

    更新日期:2014-04-01 00:00:00

  • Corrigendum: Tissue-engineered nerve grafts using a scaffold-independent and injectable drug delivery system: a novel design with translational advantages (2019 J. Neural Eng. 16 036030).

    abstract:OBJECTIVE:Currently commercially available nerve conduits have demonstrated suboptimal clinical efficacy in repairing peripheral nerve defects. Although tissue-engineered nerve grafts (TENGs) with sustained release of neurotrophic factors (NTFs) are experimentally proved to be more effective than these blank conduits, ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd1ec

    authors: Liu Y,Yu S,Gu X,Cao R,Cui S

    更新日期:2020-12-09 00:00:00

  • Functional consequences of model complexity in rhythmic systems: II. Systems performance of model and hybrid oscillators.

    abstract::Neural models are increasingly being used as design components of physical systems. In order to best use models in these novel contexts, we must develop design rules that describe how decisions in model construction relate to the functional performance of the resulting system. In the accompanying paper, we described a...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/4/3/003

    authors: Sorensen ME,DeWeerth SP

    更新日期:2007-09-01 00:00:00

  • Brain-actuated gait trainer with visual and proprioceptive feedback.

    abstract:OBJECTIVE:Brain-machine interfaces (BMIs) have been proposed in closed-loop applications for neuromodulation and neurorehabilitation. This study describes the impact of different feedback modalities on the performance of an EEG-based BMI that decodes motor imagery (MI) of leg flexion and extension. APPROACH:We execute...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa7df9

    authors: Liu D,Chen W,Lee K,Chavarriaga R,Bouri M,Pei Z,Del R Millán J

    更新日期:2017-10-01 00:00:00

  • In vivo feasibility of epiretinal stimulation using ultrananocrystalline diamond electrodes.

    abstract:OBJECTIVE:Due to their increased proximity to retinal ganglion cells (RGCs), epiretinal visual prostheses present the opportunity for eliciting phosphenes with low thresholds through direct RGC activation. This study characterised the in vivo performance of a novel prototype monolithic epiretinal prosthesis, containing...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aba560

    authors: Shivdasani MN,Evans M,Burns O,Yeoh J,Allen PJ,Nayagam DAX,Villalobos J,Abbott CJ,Luu CD,Opie NL,Sabu A,Saunders AL,McPhedran M,Cardamone L,McGowan C,Maxim V,Williams RA,Fox KE,Cicione R,Garrett DJ,Ahnood A,Ganes

    更新日期:2020-08-05 00:00:00

  • Analysis of the quasi-static approximation for calculating potentials generated by neural stimulation.

    abstract::In models of electrical stimulation of the nervous system, the electric potential is typically calculated using the quasi-static approximation. The quasi-static approximation allows Maxwell's equations to be simplified by ignoring capacitive, inductive and wave propagation contributions to the potential. While this si...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/5/1/005

    authors: Bossetti CA,Birdno MJ,Grill WM

    更新日期:2008-03-01 00:00:00

  • Interleaved intramuscular stimulation with minimally overlapping electrodes evokes smooth and fatigue resistant forces.

    abstract:OBJECTIVE:It is known that multi-site interleaved stimulation generates less muscle fatigue compared to single-site synchronous stimulation. However, in the limited number of studies in which intramuscular electrodes were used, the fatigue reduction associated with interleaved stimulation could not consistently be achi...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aba99e

    authors: Eladly A,Del Valle J,Minguillon J,Mercadal B,Becerra-Fajardo L,Navarro X,Ivorra A

    更新日期:2020-08-25 00:00:00

  • Neuromusculoskeletal model self-calibration for on-line sequential bayesian moment estimation.

    abstract:OBJECTIVE:Neuromusculoskeletal models involve many subject-specific physiological parameters that need to be adjusted to adequately represent muscle properties. Traditionally, neuromusculoskeletal models have been calibrated with a forward-inverse dynamic optimization which is time-consuming and unfeasible for rehabili...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa58f5

    authors: Bueno DR,Montano L

    更新日期:2017-04-01 00:00:00

  • Hardware architecture for real-time EEG-based functional brain connectivity parameter extraction.

    abstract::In this work, we proposed a novel architecture for real-time quantitative characterization of functional brain connectivity networks derived from Electroencephalogram (EEG). It consists of two main parts - calculation of Phase Lag Index (PLI) to form the functional connectivity networks and the extraction of a set of ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abd462

    authors: Gutierrez Nuno RA,Chung CHR,Maharatna K

    更新日期:2020-12-16 00:00:00

  • Rehabilitation regimes based upon psychophysical studies of prosthetic vision.

    abstract::Human trials of prototype visual prostheses have successfully elicited visual percepts (phosphenes) in the visual field of implant recipients blinded through retinitis pigmentosa and age-related macular degeneration. Researchers are progressing rapidly towards a device that utilizes individual phosphenes as the elemen...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,评审

    doi:10.1088/1741-2560/6/3/035009

    authors: Chen SC,Suaning GJ,Morley JW,Lovell NH

    更新日期:2009-06-01 00:00:00

  • Dynamics and coupling of fractional-order models of the motor cortex and central pattern generators.

    abstract:OBJECTIVE:Fractional calculus plays a key role in the analysis of neural dynamics. In particular, fractional calculus has been recently exploited for analyzing complex biological systems and capturing intrinsic phenomena. Also, artificial neural networks have been shown to have complex neuronal dynamics and characteris...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/ab8dd6

    authors: Lu Q

    更新日期:2020-06-12 00:00:00

  • An intra-operative feature-based classification of microelectrode recordings to support the subthalamic nucleus functional identification during deep brain stimulation surgery.

    abstract:OBJECTIVE:The Subthalamic Nucleus (STN) is the most selected target for the placement of the Deep Brain Stimulation (DBS) electrode to treat Parkinson's disease. Its identification is a delicate and challenging task which is based on the interpretation of the STN functional activity acquired through microelectrode reco...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abcb15

    authors: Coelli S,Levi V,Del Vecchio Del Vecchio J,Mailland E,Rinaldo S,Eleopra R,Bianchi AM

    更新日期:2020-11-17 00:00:00

  • The statistical distribution of noisy transmission in human sensors.

    abstract:OBJECTIVE:Brains, like other physical devices, are inherently noisy. This source of variability is large, to the extent that internal noise often impacts human sensory processing more than externally induced (stimulus-driven) perturbations. Despite the fundamental nature of this phenomenon, its statistical distribution...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章,随机对照试验

    doi:10.1088/1741-2560/10/1/016014

    authors: Neri P

    更新日期:2013-02-01 00:00:00

  • Coarse behavioral context decoding.

    abstract:OBJECTIVE:Current brain-computer interface (BCI) studies demonstrate the potential to decode neural signals obtained from structured and trial-based tasks to drive actuators with high performance within the context of these tasks. Ideally, to maximize utility, such systems will be applied to a wide range of behavioral ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aaee9c

    authors: Alasfour A,Gabriel P,Jiang X,Shamie I,Melloni L,Thesen T,Dugan P,Friedman D,Doyle W,Devinsky O,Gonda D,Sattar S,Wang S,Halgren E,Gilja V

    更新日期:2019-02-01 00:00:00

  • Spatial channel interactions in cochlear implants.

    abstract::The modern multi-channel cochlear implant is widely considered to be the most successful neural prosthesis owing to its ability to restore partial hearing to post-lingually deafened adults and to allow essentially normal language development in pre-lingually deafened children. However, the implant performance varies g...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/4/046029

    authors: Tang Q,Benítez R,Zeng FG

    更新日期:2011-08-01 00:00:00

  • Extracellular voltage profile for reversing the recruitment order of peripheral nerve stimulation: a simulation study.

    abstract::Electrical stimulation of peripheral nerve activates large-diameter fibers before small ones. A physiological recruitment order, from small to large-diameter axons, is desirable in many applications. Previous studies using computer simulations showed that selective activation of small fibers could be achieved by resha...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/1/4/003

    authors: Lertmanorat Z,Durand DM

    更新日期:2004-12-01 00:00:00

  • Ten-dimensional anthropomorphic arm control in a human brain-machine interface: difficulties, solutions, and limitations.

    abstract:OBJECTIVE:In a previous study we demonstrated continuous translation, orientation and one-dimensional grasping control of a prosthetic limb (seven degrees of freedom) by a human subject with tetraplegia using a brain-machine interface (BMI). The current study, in the same subject, immediately followed the previous work...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/12/1/016011

    authors: Wodlinger B,Downey JE,Tyler-Kabara EC,Schwartz AB,Boninger ML,Collinger JL

    更新日期:2015-02-01 00:00:00

  • Multiple factors may influence the performance of a visual prosthesis based on intracortical microstimulation: nonhuman primate behavioural experimentation.

    abstract::We hypothesize that a visual prosthesis capable of evoking high-resolution visual perceptions can be produced using high-electrode-count arrays of penetrating microelectrodes implanted into the primary visual cortex of a blind human subject. To explore this hypothesis, and as a prelude to human psychophysical experime...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/8/3/035001

    authors: Torab K,Davis TS,Warren DJ,House PA,Normann RA,Greger B

    更新日期:2011-06-01 00:00:00

  • A micro-scale printable nanoclip for electrical stimulation and recording in small nerves.

    abstract:OBJECTIVE:The vision of bioelectronic medicine is to treat disease by modulating the signaling of visceral nerves near various end organs. In small animal models, the nerves of interest can have small diameters and limited surgical access. New high-resolution methods for building nerve interfaces are desirable. In this...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aa5a5b

    authors: Lissandrello CA,Gillis WF,Shen J,Pearre BW,Vitale F,Pasquali M,Holinski BJ,Chew DJ,White AE,Gardner TJ

    更新日期:2017-06-01 00:00:00

  • Decoding multiclass motor imagery EEG from the same upper limb by combining Riemannian geometry features and partial least squares regression.

    abstract:OBJECTIVE:Due to low spatial resolution and poor signal-to-noise ratio of electroencephalogram (EEG), high accuracy classifications still suffer from lots of obstacles in the context of motor imagery (MI)-based brain-machine interface (BMI) systems. Particularly, it is extremely challenging to decode multiclass MI EEG ...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/aba7cd

    authors: Chu Y,Zhao X,Zou Y,Xu W,Song G,Han J,Zhao Y

    更新日期:2020-08-11 00:00:00

  • The analytic common spatial patterns method for EEG-based BCI data.

    abstract::One of the most important stages in a brain-computer interface (BCI) system is that of extracting features that can reliably discriminate data recorded during different user states. A popular technique used for feature extraction in BCIs is the common spatial patterns (CSP) method, which provides a set of spatial filt...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2560/9/4/045009

    authors: Falzon O,Camilleri KP,Muscat J

    更新日期:2012-08-01 00:00:00

  • Acoustoelectric imaging of deep dipoles in a human head phantom for guiding treatment of epilepsy.

    abstract:OBJECTIVE:This study employs a human head model with real skull to demonstrate the feasibility of transcranial acoustoelectric brain imaging (tABI) as a new modality for electrical mapping of deep dipole sources during treatment of epilepsy with much better resolution and accuracy than conventional mapping methods. AP...

    journal_title:Journal of neural engineering

    pub_type: 杂志文章

    doi:10.1088/1741-2552/abb63a

    authors: Barragan A,Preston C,Alvarez A,Bera T,Qin Y,Weinand M,Kasoff W,Witte RS