Inferring spatial variations of microstructural properties from macroscopic mechanical response.

Abstract:

:Disease alters tissue microstructure, which in turn affects the macroscopic mechanical properties of tissue. In elasticity imaging, the macroscopic response is measured and is used to infer the spatial distribution of the elastic constitutive parameters. When an empirical constitutive model is used, these parameters cannot be linked to the microstructure. However, when the constitutive model is derived from a microstructural representation of the material, it allows for the possibility of inferring the local averages of the spatial distribution of the microstructural parameters. This idea forms the basis of this study. In particular, we first derive a constitutive model by homogenizing the mechanical response of a network of elastic, tortuous fibers. Thereafter, we use this model in an inverse problem to determine the spatial distribution of the microstructural parameters. We solve the inverse problem as a constrained minimization problem and develop efficient methods for solving it. We apply these methods to displacement fields obtained by deforming gelatin-agar co-gels and determine the spatial distribution of agar concentration and fiber tortuosity, thereby demonstrating that it is possible to image local averages of microstructural parameters from macroscopic measurements of deformation.

authors

Liu T,Hall TJ,Barbone PE,Oberai AA

doi

10.1007/s10237-016-0831-0

subject

Has Abstract

pub_date

2017-04-01 00:00:00

pages

479-496

issue

2

eissn

1617-7959

issn

1617-7940

pii

10.1007/s10237-016-0831-0

journal_volume

16

pub_type

杂志文章
  • Modeling active muscle contraction in mitral valve leaflets during systole: a first approach.

    abstract::The present study addresses the effect of muscle activation contributions to mitral valve leaflet response during systole. State-of-art passive hyperelastic material modeling is employed in combination with a simple active stress part. Fiber families are assumed in the leaflets: one defined by the collagen and one def...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-010-0215-9

    authors: Skallerud B,Prot V,Nordrum IS

    更新日期:2011-02-01 00:00:00

  • A computational thrombus formation model: application to an idealized two-dimensional aneurysm treated with bare metal coils.

    abstract::Cardiovascular implantable devices alter the biofluid dynamics and biochemistry of the blood in which they are placed. These perturbations can lead to thrombus formation which may or may not be desired, depending on the application. In this work, a computational model is developed that couples biofluid dynamics and bi...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-018-1059-y

    authors: Horn JD,Maitland DJ,Hartman J,Ortega JM

    更新日期:2018-12-01 00:00:00

  • A chemo-mechanical constitutive model for transiently cross-linked actin networks and a theoretical assessment of their viscoelastic behaviour.

    abstract::Biological materials can undergo large deformations and also show viscoelastic behaviour. One such material is the network of actin filaments found in biological cells, giving the cell much of its mechanical stiffness. A theory for predicting the relaxation behaviour of actin networks cross-linked with the cross-linke...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-012-0406-7

    authors: Fallqvist B,Kroon M

    更新日期:2013-04-01 00:00:00

  • Infant brain subjected to oscillatory loading: material differentiation, properties, and interface conditions.

    abstract::Past research into brain injury biomechanics has focussed on short duration impulsive events as opposed to the oscillatory loadings associated with Shaken Baby Syndrome (SBS). A series of 2D finite element models of an axial slice of the infant head were created to provide qualitative information on the behaviour of t...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-007-0079-9

    authors: Couper Z,Albermani F

    更新日期:2008-04-01 00:00:00

  • An orthotropic electro-viscoelastic model for the heart with stress-assisted diffusion.

    abstract::We propose and analyse the properties of a new class of models for the electromechanics of cardiac tissue. The set of governing equations consists of nonlinear elasticity using a viscoelastic and orthotropic exponential constitutive law, for both active stress and active strain formulations of active mechanics, couple...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-019-01237-y

    authors: Propp A,Gizzi A,Levrero-Florencio F,Ruiz-Baier R

    更新日期:2020-04-01 00:00:00

  • A model for arterial adaptation combining microstructural collagen remodeling and 3D tissue growth.

    abstract::Long-term adaptation of soft tissues is realized through growth and remodeling (G&R). Mathematical models are powerful tools in testing hypotheses on G&R and supporting the design and interpretation of experiments. Most theoretical G&R studies concentrate on description of either growth or remodeling. Our model combin...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-010-0204-z

    authors: Machyshyn IM,Bovendeerd PH,van de Ven AA,Rongen PM,van de Vosse FN

    更新日期:2010-12-01 00:00:00

  • A hybrid bioregulatory model of angiogenesis during bone fracture healing.

    abstract::Bone fracture healing is a complex process in which angiogenesis or the development of a blood vessel network plays a crucial role. In this paper, a mathematical model is presented that simulates the biological aspects of fracture healing including the formation of individual blood vessels. The model consists of parti...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-010-0241-7

    authors: Peiffer V,Gerisch A,Vandepitte D,Van Oosterwyck H,Geris L

    更新日期:2011-06-01 00:00:00

  • An elasto-viscoplastic model to describe the ratcheting behavior of articular cartilage.

    abstract::In the present work, a constitutive model for articular cartilage is proposed in finite elasto-viscoplasticity. For simplification, articular cartilage is supposed to be a typical composite composed of a soft basis and a fiber assembly. The stress tensor and free energy function are hence accordingly divided into two ...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-018-1062-3

    authors: Zhu Y

    更新日期:2018-12-01 00:00:00

  • Tortuosity of the superficial femoral artery and its influence on blood flow patterns and risk of atherosclerosis.

    abstract::The superficial femoral artery (SFA) is a typical atherosclerosis-prone site. We aimed to explore whether the tortuosity of the SFA associates with the occurrence of atherosclerosis and investigate how vascular tortuosity influences the characteristics of blood flow. Ten patients diagnosed with atherosclerotic disease...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-019-01118-4

    authors: Li X,Liu X,Li X,Xu L,Chen X,Liang F

    更新日期:2019-08-01 00:00:00

  • Simulation of multi-stage nonlinear bone remodeling induced by fixed partial dentures of different configurations: a comparative clinical and numerical study.

    abstract::This paper aimed to develop a clinically validated bone remodeling algorithm by integrating bone's dynamic properties in a multi-stage fashion based on a four-year clinical follow-up of implant treatment. The configurational effects of fixed partial dentures (FPDs) were explored using a multi-stage remodeling rule. Th...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-016-0826-x

    authors: Liao Z,Yoda N,Chen J,Zheng K,Sasaki K,Swain MV,Li Q

    更新日期:2017-04-01 00:00:00

  • Contraction of collecting lymphatics: organization of pressure-dependent rate for multiple lymphangions.

    abstract::The paper describes the extension of a previously developed model of pressure-dependent contraction rate to the case of multiple lymphangions. Mechanical factors are key modulators of active lymphatic pumping. As part of the evolution of our lumped-parameter model to match experimental findings, we have designed an al...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-018-1042-7

    authors: Bertram CD,Macaskill C,Davis MJ,Moore JE Jr

    更新日期:2018-10-01 00:00:00

  • A two-muscle, continuum-mechanical forward simulation of the upper limb.

    abstract::By following the common definition of forward-dynamics simulations, i.e. predicting movement based on (neural) muscle activity, this work describes, for the first time, a forward-dynamics simulation framework of a musculoskeletal system, in which all components are represented as continuous, three-dimensional, volumet...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-016-0850-x

    authors: Röhrle O,Sprenger M,Schmitt S

    更新日期:2017-06-01 00:00:00

  • Peristaltic biofluids flow through vertical porous human vessels using third-grade non-Newtonian fluids model.

    abstract::In this paper, the heat and flow characteristic of third-grade non-Newtonian biofluids flow through a vertical porous human vessel due to peristaltic wall motion are studied. The third-grade model can describe shear thinning (or shear thickening) and normal stress differences, which is acceptable for biofluids modelin...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-017-0945-z

    authors: Akbarzadeh P

    更新日期:2018-02-01 00:00:00

  • Determining constitutive behavior of the brain tissue using digital image correlation and finite element modeling.

    abstract::Detailed knowledge about the mechanical properties of brain can improve numerical modeling of the brain under various loading conditions. The success of this modeling depends on constitutive model and reliable extraction of its material constants. The isotropy of the brain tissue is a key factor which affects the form...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-019-01186-6

    authors: Felfelian AM,Baradaran Najar A,Jafari Nedoushan R,Salehi H

    更新日期:2019-12-01 00:00:00

  • A coupled model of neovessel growth and matrix mechanics describes and predicts angiogenesis in vitro.

    abstract::During angiogenesis, sprouting microvessels interact with the extracellular matrix (ECM) by degrading and reorganizing the matrix, applying traction forces, and producing deformation. Morphometric features of the resulting microvascular network are affected by the interaction between the matrix and angiogenic microves...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-014-0635-z

    authors: Edgar LT,Maas SA,Guilkey JE,Weiss JA

    更新日期:2015-08-01 00:00:00

  • Time-dependent behavior of cartilage surrounding a metal implant for full-thickness cartilage defects of various sizes: a finite element study.

    abstract::Recently, physiological and biomechanical studies on animal models with metal implants filling full-thickness cartilage defects have resulted in good clinical outcomes. The knowledge of the time-dependent macroscopic behavior of cartilage surrounding the metal implant is essential for understanding the joint function ...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-011-0346-7

    authors: Manda K,Eriksson A

    更新日期:2012-05-01 00:00:00

  • Analysis of mechanical parameters on the thromboembolism using a patient-specific computational model.

    abstract::Ischemic stroke is a major cause of death and long-term disabilities worldwide. In this paper, we aim to represent a comprehensive simulation of the motion of emboli through cerebrovascular network within patient-specific computational model. The model consists of major arteries of the circle of Willis reconstructed f...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-016-0762-9

    authors: Khodaee F,Vahidi B,Fatouraee N

    更新日期:2016-10-01 00:00:00

  • The mechanical behaviour of chondrocytes predicted with a micro-structural model of articular cartilage.

    abstract::The integrity of articular cartilage depends on the proper functioning and mechanical stimulation of chondrocytes, the cells that synthesize extracellular matrix and maintain tissue health. The biosynthetic activity of chondrocytes is influenced by genetic factors, environmental influences, extracellular matrix compos...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-006-0016-3

    authors: Han SK,Federico S,Grillo A,Giaquinta G,Herzog W

    更新日期:2007-04-01 00:00:00

  • Dynamic modeling for shear stress induced ATP release from vascular endothelial cells.

    abstract::A dynamic model is proposed for shear stress induced adenosine triphosphate (ATP) release from endothelial cells (ECs). The dynamic behavior of the ATP/ADP concentration at the endothelial surface by viscous shear flow is investigated through simulation studies based on the dynamic ATP release model. The numerical res...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-007-0088-8

    authors: Qin KR,Xiang C,Xu Z,Cao LL,Ge SS,Jiang ZL

    更新日期:2008-10-01 00:00:00

  • A growth-based model for the prediction of fiber angle distribution in the intervertebral disc annulus fibrosus.

    abstract::There is a growing interest in the development of patient-specific finite element models of the human lumbar spine for both the assessment of injury risk and the development of treatment strategies. A current challenge in implementing these models is that the outer annulus fibrosus of the disc is composed of concentri...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-019-01150-4

    authors: Michalek AJ

    更新日期:2019-10-01 00:00:00

  • On the representation of effective stress for computing hemolysis.

    abstract::Hemolysis is a major concern in blood-circulating devices, which arises due to hydrodynamic loading on red blood cells from ambient flow environment. Hemolysis estimation models have often been used to aid hemocompatibility design. The preponderance of hemolysis models was formulated on the basis of laminar flows. How...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-018-01108-y

    authors: Wu P,Gao Q,Hsu PL

    更新日期:2019-06-01 00:00:00

  • A mathematical model for fluid shear-sensitive 3D tissue construct development.

    abstract::This research studies dynamic culture for 3D tissue construct development with computational fluid dynamics. It proposes a mathematical model to evaluate the impact of flow rates and flow shear stress on cell growth in 3D constructs under perfusion. The modeling results show that dynamic flow, even at flow rate as low...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-012-0378-7

    authors: Liu D,Chua CK,Leong KF

    更新日期:2013-01-01 00:00:00

  • Mean arterial pressure nonlinearity in an elastic circulatory system subjected to different hematocrits.

    abstract::The level of hematocrit (Hct) is known to affect mean arterial pressure (MAP) by influencing blood viscosity. In the healthy population, an increase in Hct (and corresponding increase in viscosity) tends to raise MAP. However, data from a clinical study of type 2 diabetic patients indicate that this relationship is no...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-010-0258-y

    authors: Branigan T,Bolster D,Vázquez BY,Intaglietta M,Tartakovsky DM

    更新日期:2011-07-01 00:00:00

  • A novel method for non-invasively detecting the severity and location of aortic aneurysms.

    abstract::The influence of an aortic aneurysm on blood flow waveforms is well established, but how to exploit this link for diagnostic purposes still remains challenging. This work uses a combination of experimental and computational modelling to study how aneurysms of various size affect the waveforms. Experimental studies are...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-017-0884-8

    authors: Sazonov I,Khir AW,Hacham WS,Boileau E,Carson JM,van Loon R,Ferguson C,Nithiarasu P

    更新日期:2017-08-01 00:00:00

  • Deformation of human red blood cells in extensional flow through a hyperbolic contraction.

    abstract::Flow-induced damage to red blood cells has been an issue of considerable importance since the introduction of the first cardiovascular devices. Early blood damage prediction models were based on measurements of damage by shear stress only. Subsequently, these models were extrapolated to include other components of the...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-019-01208-3

    authors: Faghih MM,Sharp MK

    更新日期:2020-02-01 00:00:00

  • Contribution of postnatal collagen reorientation to depth-dependent mechanical properties of articular cartilage.

    abstract::The collagen fibril network is an important factor for the depth-dependent mechanical behaviour of adult articular cartilage (AC). Recent studies show that collagen orientation is parallel to the articular surface throughout the tissue depth in perinatal animals, and that the collagen orientations transform to a depth...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-010-0233-7

    authors: van Turnhout MC,Kranenbarg S,van Leeuwen JL

    更新日期:2011-04-01 00:00:00

  • Relationship between apical membrane elasticity and stress fiber organization in fibroblasts analyzed by fluorescence and atomic force microscopy.

    abstract::To investigate the relationship between cellular microelasticity and the structural features of cytoskeletons (CSKs), a microindentation test for apical cell membranes and observation of the spatio-distribution of actin CSKs of fibroblasts were performed by fluorescence and atomic force microscopy (FM/AFM). The indent...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-006-0048-8

    authors: Kidoaki S,Matsuda T,Yoshikawa K

    更新日期:2006-11-01 00:00:00

  • Creep and stress relaxation of human red cell membrane.

    abstract::In contrast to most mechanical properties of the red cell, experimental information on stress relaxation (SR) of the membrane skeleton is scarce. On the other hand, many postulates or assumptions as to the value of the characteristic time of SR [Formula: see text] can be found in the literature. Here, an experiment is...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-016-0813-2

    authors: Fischer TM

    更新日期:2017-02-01 00:00:00

  • Patient-specific predictions of aneurysm growth and remodeling in the ascending thoracic aorta using the homogenized constrained mixture model.

    abstract::In its permanent quest of mechanobiological homeostasis, our vasculature significantly adapts across multiple length and timescales in various physiological and pathological conditions. Computational modeling of vascular growth and remodeling (G&R) has significantly improved our insights into the mechanobiological pro...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-019-01184-8

    authors: Mousavi SJ,Farzaneh S,Avril S

    更新日期:2019-12-01 00:00:00

  • Arterial pulse attenuation prediction using the decaying rate of a pressure wave in a viscoelastic material model.

    abstract::The present study examines the possibility of attenuating blood pulses by means of introducing prosthetic viscoelastic materials able to absorb energy and damp such pulses. Vascular prostheses made of polymeric materials modify the mechanical properties of blood vessels. The effect of these materials on the blood puls...

    journal_title:Biomechanics and modeling in mechanobiology

    pub_type: 杂志文章

    doi:10.1007/s10237-017-0980-9

    authors: Menacho J,Rotllant L,Molins JJ,Reyes G,García-Granada AA,Balcells M,Martorell J

    更新日期:2018-04-01 00:00:00