Etoricoxib-induced immune hemolytic anemia: first case presenting acute kidney failure.

Abstract:

BACKGROUND:Etoricoxib is a selective inhibitor of cyclooxygenase 2 used mainly to treat osteoarticular pain. Here, we report the case of a patient who developed acute kidney failure and immune hemolytic anemia after the use of etoricoxib. STUDY DESIGN AND METHODS:An 83-year-old female patient developed immune hemolytic anemia and acute kidney failure after treatment with etoricoxib for articular pain. Given the acute kidney failure, she required five hemodialysis sessions. She was discharged after 17 days. The case of immune hemolytic anemia and kidney failure was fully resolved. RESULTS:The direct antiglobulin test was not only positive for IgG but also for C3b and C3d, showing a very intense reactivity (++++). The eluate's reactivity was weaker (++) and showed no defined specificity. The investigation of unexpected antibodies in the serum of the patient showed a reactivity pattern similar to the eluate's: weak reactivity without specificity. The serum of the patient was compared to urine and plasma samples of two groups of volunteers. The indirect antiglobulin test showed only a very strong reactivity with the urine samples of the volunteers who had received etoricoxib. DISCUSSION:Considering that positive eluate is not the typical serologic profile of drug-induced immune hemolytic anemia, developing in-house techniques to show the causal link between them may be of interest to guide the treatment and avoid the empirical use of drugs. CONCLUSION:Etoricoxib must be considered as a possible cause of acute kidney failure in cases of immune hemolytic anemia.

journal_name

Transfusion

journal_title

Transfusion

authors

Burgos Pratx L,Santoro D,Coca Mogro B,Valiente VL,Camino P,Scordo W,Salamone H

doi

10.1111/trf.15226

subject

Has Abstract

pub_date

2019-05-01 00:00:00

pages

1657-1660

issue

5

eissn

0041-1132

issn

1537-2995

journal_volume

59

pub_type

  • The influence of irradiation on stored platelets.

    abstract::Platelet concentrates intended for transfusion to immunosuppressed patients are irradiated to minimize transfusion-induced graft-versus-host disease. Because few reports describe how irradiation influences stored platelets, the authors studied whether 5000 rad of gamma irradiation, the maximum dose currently used clin...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1986.26587020124.x

    authors: Moroff G,George VM,Siegl AM,Luban NL

    更新日期:1986-09-01 00:00:00

  • Radiation-induced red cell damage: role of reactive oxygen species.

    abstract:BACKGROUND:Cellular blood components are irradiated to prevent graft-versus-host disease in transfusion recipients at risk for this syndrome. Because gamma radiation can result in the production of reactive oxygen species, the role of reactive oxygen species was investigated in radiation-induced red cell damage. STUDY...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1997.37297203518.x

    authors: Anand AJ,Dzik WH,Imam A,Sadrzadeh SM

    更新日期:1997-02-01 00:00:00

  • Red blood cell minor antigen mismatches during chronic transfusion therapy for sickle cell anemia.

    abstract:BACKGROUND:Red blood cell (RBC) alloimmunization occurs at a high frequency in sickle cell anemia (SCA) despite serologic matching for Rh (C/c, E/e) and K antigens. RBC minor antigen genotyping allows for prediction of antigens and RH variants that may lead to alloimmunization. STUDY DESIGN AND METHODS:RBC antigen gen...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.14282

    authors: Yee MEM,Josephson CD,Winkler AM,Webb J,Luban NLC,Leong T,Stowell SR,Fasano RM

    更新日期:2017-11-01 00:00:00

  • Evaluation of a new whole-blood filter that allows preparation of platelet concentrates by platelet-rich plasma methods.

    abstract:BACKGROUND:A novel WBC-reduction in-line whole-blood (WB) filter that does not retain platelets was evaluated to assess the filtration performance and, after processing WB by the platelet-rich plasma (PRP) method, to analyze the storage quality of filtered platelet concentrate (PC) units. STUDY DESIGN AND METHODS:To a...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.0041-1132.2003.00587.x

    authors: Lozano ML,Pérez-Ceballos E,Rivera J,Paunovic D,Candela MJ,Vicente V

    更新日期:2003-12-01 00:00:00

  • Immune-mediated agglutination of cytoskeleton-free RBC microvesicles.

    abstract:BACKGROUND:The factors contributing to RBC agglutination are complex. The RBC cytoskeleton's participation in and contribution to this phenomenon are difficult to separate from those of the plasma membrane. Immunoreactive, cytoskeleton-free, band 3-enriched microvesicles can be generated from normal RBCs. Band 3 has be...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.2000.40050566.x

    authors: Jaime JC

    更新日期:2000-05-01 00:00:00

  • Maternal human platelet antigen-1a antibody level correlates with the platelet count in the newborns: a retrospective study.

    abstract:BACKGROUND:Maternal plasma and/or serum levels of anti-HPA-1a at delivery were compared to neonatal platelet (PLT) counts. STUDY DESIGN AND METHODS:Samples from HPA-1bb women who gave birth to children with thrombocytopenia or had anamnestic information about a previous child with neonatal alloimmune thrombocytopenia ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2007.01063.x

    authors: Killie MK,Husebekk A,Kaplan C,Taaning E,Skogen B

    更新日期:2007-01-01 00:00:00

  • Complete or partial seroreversion in immunocompetent individuals after self-limited HCV infection: consequences for transfusion.

    abstract:BACKGROUND:The disappearance of anti-HCV antibodies over time, after a self-limited infection, also referenced seroreversion, has been observed. The frequency of this phenomenon remains controversial, especially in immunocompetent subjects. However, it has important implications in the context of transfusion inquiries,...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2004.00656.x

    authors: Lefrère JJ,Girot R,Lefrère F,Guillaume N,Lerable J,Le Marrec N,Bouchardeau F,Laperche S

    更新日期:2004-03-01 00:00:00

  • Blood screening nucleic acid amplification tests for human immunodeficiency virus Type 1 may require two different amplification targets.

    abstract:BACKGROUND:Five cases of human immunodeficiency virus Type 1 (HIV-1) RNA-positive blood donations are described that escaped detection by three different CE-marked nucleic acid amplification technique (NAT) screening assays. These events were associated with two HIV-1 transmissions to recipients of blood components. Th...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2011.03281.x

    authors: Chudy M,Weber-Schehl M,Pichl L,Jork C,Kress J,Heiden M,Funk MB,Nübling CM

    更新日期:2012-02-01 00:00:00

  • Direct HIV testing in blood donations: variation of the yield with detection threshold and pool size.

    abstract:BACKGROUND:This study was designed to evaluate the potential yield of introducing nucleic acid amplification testing (NAT) in blood donation, according to the detection threshold and the pool size. STUDY DESIGN AND METHODS:A mathematical model of early HIV-1 population dynamics in blood has been developed and is used ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1999.39101141.x

    authors: Le Corfec E,Le Pont F,Tuckwell HC,Rouzioux C,Costagliola D

    更新日期:1999-10-01 00:00:00

  • Effect of blood donation on the establishment of normal ranges of lymphocyte subsets.

    abstract:BACKGROUND:Absolute counts of CD4+ T-lymphocytes are used in the management of patients with human immunodeficiency virus infection. Low absolute counts of CD3+CD4+ cells have also been observed in healthy people--a phenomenon called idiopathic CD4 lymphocytopenia. It is common practice for normal ranges for lymphocyte...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1996.36696269517.x

    authors: Bryant JA,Wylie BR,Yuan FF,Ribeiro A,Thomson AR,Cooley MA,Fletcher A

    更新日期:1996-06-01 00:00:00

  • Roles of acetate and phosphate in the successful storage of platelet concentrates prepared with an acetate-containing additive solution.

    abstract::The development of a synthetic medium for platelet storage is an important goal in transfusion medicine. Its use would make large volumes of plasma available for fractionation and might improve the quality of platelets after storage. Several investigators have described successful storage in media containing acetate. ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1993.33493242637.x

    authors: Shimizu T,Murphy S

    更新日期:1993-04-01 00:00:00

  • Hemolytic markers following the transfusion of uncrossmatched, cold-stored, low-titer, group O+ whole blood in civilian trauma patients.

    abstract:BACKGROUND:Low-titer group O whole blood (LTOWB) is increasingly being used in the civilian trauma setting, although there is a risk of hemolysis. This study evaluated the impact on hemolytic markers following the transfusion of 4 or more units of uncrossmatched LTOWB. METHODS:Civilian adult trauma patients who receiv...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.15629

    authors: Harrold IM,Seheult JN,Alarcon LH,Corcos A,Sperry JL,Triulzi DJ,Yazer MH

    更新日期:2020-06-01 00:00:00

  • Compatibility testing without a centrifuge: the slide Polybrene method.

    abstract:BACKGROUND:A simple and rapid slide Polybrene method (SP) for pretransfusion compatibility testing is described. SP is particularly suitable for use in developing countries where, due to limited resources, centrifuges and biologic reagents may not be readily available. STUDY DESIGN AND METHODS:The original manual Poly...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2004.00659.x

    authors: Lin M

    更新日期:2004-03-01 00:00:00

  • Increased risk of a positive test for antibody to hepatitis B core antigen (anti-HBC) in autologous blood donors.

    abstract::Controversy exists about the suitability of blood from autologous donors for homologous use. We compared the infectious disease test results of 426 autologous donors, designated by donor history as suitable for homologous use, to those of 86,138 volunteer donations collected over the same 5 month period. Although dono...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1988.28388219162.x

    authors: Grossman BJ,Stewart NC,Grindon AJ

    更新日期:1988-05-01 00:00:00

  • Storage of aliquots of apheresis platelets for neonatal use in syringes with and without agitation.

    abstract:BACKGROUND:To facilitate volume control in neonates, platelets (PLTs) are aliquoted and stored for short periods in non-gas-permeable syringes before infusion. Although agitation of PLTs during storage in gas-permeable bags is performed to maintain their quality, the effect of syringe agitation during storage is unknow...

    journal_title:Transfusion

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1537-2995.2011.03230.x

    authors: Diab Y,Wong E,Criss VR,Moroff G,Wagner SJ,Luban NL

    更新日期:2011-12-01 00:00:00

  • Leukocyte depletion of red cell units at the bedside by transfusion through a new filter.

    abstract::Standard packed red cell (PRC) units can be depleted of leukocytes and platelets if they are transfused through a blood administration set in which the usual 170-mu filter has been replaced by a leukocyte removal filter (Sepacell R-500). During a 6-month period, 1550 PRC units were transfused through this filter in 61...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1987.27587320533.x

    authors: Sirchia G,Rebulla P,Parravicini A,Carnelli V,Gianotti GA,Bertolini F

    更新日期:1987-09-01 00:00:00

  • Multiple pH measurement during storage may detect bacterially contaminated platelet concentrates.

    abstract:BACKGROUND:Bacterial contamination or platelet (PLT) metabolism can change the pH of stored PLT concentrates (PCs). Measurement of pH for quality control is currently done on a limited basis. An easy noninvasive method was developed to obtain sequential pH measurements over time, without risking contamination and/or co...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2010.02727.x

    authors: Barker LM,Nanassy OZ,Reed MW,Geelhood SJ,Pfalzgraf RD,Cangelosi GA,De Korte D

    更新日期:2010-12-01 00:00:00

  • Genetic diversity of KELnull and KELel: a nationwide Austrian survey.

    abstract:BACKGROUND:Besides ABO and RH, the KEL blood group system, including the two antithetical antigens KEL1 and KEL2, is the most important owing to the frequent appearance of anti-KEL alloantibodies and their considerable clinical significance. So far, only limited information was available on KEL variant alleles determin...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2007.01174.x

    authors: Körmöczi GF,Wagner T,Jungbauer C,Vadon M,Ahrens N,Moll W,Mühlbacher A,Ozgül-Gülce S,Kleinrath T,Kilga-Nogler S,Schönitzer D,Gassner C

    更新日期:2007-04-01 00:00:00

  • Large scale preparation of leukocyte concentrates and further purification of lymphocytes and granulocytes with the IBM 2991 cell processor.

    abstract::A procedure is described for the large-scale production of pure suspensions of human lymphocytes and granulocytes. Platelet-poor buffy-coats, obtained by centrifugation of six units of ABO-compatible ACD blood, were pooled and centrifuged again, resulting in a crude leukocyte concentrate containing approximately 60 pe...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1977.17578014593.x

    authors: de la Rivière AB,Verhoef-Karssen PR,de Wit JJ,Loos JA,Prins HK

    更新日期:1977-09-01 00:00:00

  • Postdonation iron replacement for maintaining iron stores in female whole blood donors in routine donor practice: results of two feasibility studies in Australia.

    abstract:BACKGROUND:Iron deficiency represents a risk to donor health and the blood supply. Efficacy trials indicate that postdonation iron replacement improves iron stores but they do not account for complexities of implementation in the routine collection context. We therefore conducted two prospective feasibility studies in ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.14173

    authors: Pasricha SR,Marks DC,Salvin H,Brama T,Keller AJ,Pink J,Speedy J

    更新日期:2017-08-01 00:00:00

  • Is placental blood a reliable source for the evaluation of neonatal hemostasis at birth?

    abstract:BACKGROUND:Phlebotomy is among the main determinants of anemia of prematurity. Blood sparing policies endorsed umbilical cord blood (here called placental) as an alternative source for laboratory testing. Little is known on the suitability of placental blood to evaluate neonatal hemostasis of newborn infants. We aimed ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.15785

    authors: Raffaeli G,Tripodi A,Manzoni F,Scalambrino E,Pesenti N,Amodeo I,Cavallaro G,Villamor E,Peyvandi F,Mosca F,Ghirardello S

    更新日期:2020-05-01 00:00:00

  • Heme-related molecules induce rapid production of neutrophil extracellular traps.

    abstract:BACKGROUND:Pulmonary endothelial cell damages caused by neutrophil overactivation could result in acute lung injuries including transfusion-related acute lung injury (TRALI). We previously reported that heme-related molecules derived from hemolysis induced the production of reactive oxygen species from neutrophils. Rec...

    journal_title:Transfusion

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/trf.12700

    authors: Kono M,Saigo K,Takagi Y,Takahashi T,Kawauchi S,Wada A,Hashimoto M,Minami Y,Imoto S,Takenokuchi M,Morikawa T,Funakoshi K

    更新日期:2014-11-01 00:00:00

  • Surveillance for Creutzfeldt-Jakob disease among persons with hemophilia.

    abstract:BACKGROUND:Although Creutzfeldt-Jakob disease (CJD) has been shown to be transmissible through blood components in rodent models, no human blood-to-blood transmission has been documented. If blood transmission were possible in humans, persons with hemophilia in the United States would be at higher risk of contracting C...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1998.38998409000.x

    authors: Evatt B,Austin H,Barnhart E,Schonberger L,Sharer L,Jones R,DeArmond S

    更新日期:1998-09-01 00:00:00

  • Sensitivity of hepatitis C virus core antigen and antibody combination assays in a global panel of window period samples.

    abstract:BACKGROUND:Hepatitis C virus (HCV) antigen and antibody combination assays have been launched as a cost-effective alternative to nucleic acid testing (NAT) for reducing the antibody-negative window period (WP). Later, a HCV antigen chemiluminescence immunoassay (CLIA) became available. STUDY DESIGN AND METHODS:A panel...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/trf.13179

    authors: Laperche S,Nübling CM,Stramer SL,Brojer E,Grabarczyk P,Yoshizawa H,Kalibatas V,El Elkyabi M,Moftah F,Girault A,van Drimmelen H,Busch MP,Lelie N

    更新日期:2015-10-01 00:00:00

  • Transfusion-acquired hepatitis C: the Danish lookback experience. The Danish HCV [hepatitis C virus] Lookback Group.

    abstract:BACKGROUND:In 1996, the Danish National Board of Health recommended hepatitis C virus (HCV) lookback to identify recipients of blood components from donors found to be positive since the implementation of anti-HCV screening in 1991. STUDY DESIGN AND METHODS:The aim was to accumulate results of the lookback at a nation...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1999.39299154734.x

    authors: Christensen PB,Groenbaek K,Krarup HB

    更新日期:1999-02-01 00:00:00

  • Evaluation of an individual-donation nucleic acid amplification testing algorithm for detecting hepatitis B virus infection in Chinese blood donors.

    abstract:BACKGROUND:This multicenter study was performed to evaluate the efficiency of a multiplex individual-donation nucleic acid amplification technology (ID-NAT) and discriminatory testing algorithm for detecting hepatitis B virus (HBV) infection in Chinese blood donors. STUDY DESIGN AND METHODS:A total of 1,205,796 hepati...

    journal_title:Transfusion

    pub_type: 杂志文章,多中心研究

    doi:10.1111/trf.13135

    authors: Gou H,Pan Y,Ge H,Zheng Y,Wu Y,Zeng J,Yang Z,Pan T,Cun W,Zhou G,Fang G,Zhang J,Zhang K,Zhang R,Sun Y,Xie J,Li J,Wang L

    更新日期:2015-09-01 00:00:00

  • Protein quality in Mirasol pathogen reduction technology-treated, apheresis-derived fresh-frozen plasma.

    abstract:BACKGROUND:The Mirasol pathogen reduction technology (PRT) system for plasma is based on a riboflavin (vitamin B(2)) and ultraviolet (UV) light treatment process resulting in pathogen inactivation due to irreversible photo-oxidative damage of nucleic acids. The purpose of this study was to evaluate the in vitro protein...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2009.02517.x

    authors: Smith J,Rock G

    更新日期:2010-04-01 00:00:00

  • Harmful effects of transfusion of older stored red blood cells: iron and inflammation.

    abstract::Retrospective studies suggest that the transfusion of older, stored red blood cells (RBCs) may be associated with increases in mortality, serious infections, multiorgan failure, thrombosis, and hospital length of stay. Our research is based on the overarching hypothesis that the adverse effects associated with transfu...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1111/j.1537-2995.2011.03096.x

    authors: Hod EA,Spitalnik SL

    更新日期:2011-04-01 00:00:00

  • WBC-reduced platelet concentrates from pooled buffy coats in additive solution: an evaluation of in vitro and in vivo measures.

    abstract:BACKGROUND:The use of a platelet additive solution (PAS-II, Baxter) may have benefits over plasma for storage of platelets. It was the aim of this study to develop a method to produce WBC-reduced platelet concentrates (PCs) in PAS-II with >240 x 10(9) platelets and <1 x 10(6) WBCs per unit, which can be stored for 5 da...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.2001.41070917.x

    authors: van der Meer PF,Pietersz RN,Tiekstra MJ,Huijgens PC,Dekker WJ,Reesink HW

    更新日期:2001-07-01 00:00:00

  • A Bombay individual lacking H and Le antigens but expressing normal levels of alpha-2- and alpha-4-fucosyltransferases.

    abstract:BACKGROUND:The rare Bombay phenotype is usually due to a primary genetic defect in an alpha-2- or alpha-4-fucosyltransferase. The present study was done to investigate a patient with normal transferases, who exhibits the Bombay phenotype. CASE REPORT:Red cells of the patient, his parents, and siblings were phenotyped ...

    journal_title:Transfusion

    pub_type: 杂志文章

    doi:10.1046/j.1537-2995.1995.35996029164.x

    authors: Shechter Y,Etzioni A,Levene C,Greenwell P

    更新日期:1995-09-01 00:00:00