Robust hyperpolarized (13)C metabolic imaging with selective non-excitation of pyruvate (SNEP).

Abstract:

:In vivo metabolic imaging using hyperpolarized [1-(13)C]pyruvate provides localized biochemical information and is particularly useful in detecting early disease changes, as well as monitoring disease progression and treatment response. However, a major limitation of hyperpolarized magnetization is its unrecoverable decay, due not only to T1 relaxation but also to radio-frequency (RF) excitation. RF excitation schemes used in metabolic imaging must therefore be able to utilize available hyperpolarized magnetization efficiently and robustly for the optimal detection of substrate and metabolite activities. In this work, a novel RF excitation scheme called selective non-excitation of pyruvate (SNEP) is presented. This excitation scheme involves the use of a spectral selective RF pulse to specifically exclude the excitation of [1-(13)C]pyruvate, while uniformly exciting the key metabolites of interest (namely [1-(13)C]lactate and [1-(13)C]alanine) and [1-(13)C]pyruvate-hydrate. By eliminating the loss of hyperpolarized [1-(13)C]pyruvate magnetization due to RF excitation, the signal from downstream metabolite pools is increased together with enhanced dynamic range. Simulation results, together with phantom measurements and in vivo experiments, demonstrated the improvement in signal-to-noise ratio (SNR) and the extension of the lifetime of the [1-(13)C]lactate and [1-(13)C]alanine pools when compared with conventional non-spectral selective (NS) excitation. SNEP has also been shown to perform comparably well with multi-band (MB) excitation, yet SNEP possesses distinct advantages, including ease of implementation, less stringent demands on gradient performance, increased robustness to frequency drifts and B0 inhomogeneity as well as easier quantification involving the use of [1-(13)C]pyruvate-hydrate as a proxy for the actual [1-(13)C] pyruvate signal. SNEP is therefore a promising alternative for robust hyperpolarized [1-(13)C]pyruvate metabolic imaging with high fidelity.

journal_name

NMR Biomed

journal_title

NMR in biomedicine

authors

Chen WC,Teo XQ,Lee MY,Radda GK,Lee P

doi

10.1002/nbm.3346

subject

Has Abstract

pub_date

2015-08-01 00:00:00

pages

1021-30

issue

8

eissn

0952-3480

issn

1099-1492

journal_volume

28

pub_type

杂志文章
  • Combined proton MR spectroscopy and dynamic contrast enhanced MR imaging of human intracranial tumours in vivo.

    abstract::A study was undertaken to determine if the vascular characteristics measured by dynamic contrast-enhanced magnetic resonance imaging (primarily permeability surface area product and extracellular-extravascular tissue volume fraction) would be beneficial in explaining the inter-lesion metabolic heterogeneity displayed ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.675

    authors: Manton DJ,Lowry M,Rowland-Hill C,Crooks D,Mathew B,Turnbull LW

    更新日期:2000-12-01 00:00:00

  • Simultaneous assessment of both lung morphometry and gas exchange function within a single breath-hold by hyperpolarized 129 Xe MRI.

    abstract::During the measurement of hyperpolarized 129 Xe magnetic resonance imaging (MRI), the diffusion-weighted imaging (DWI) technique provides valuable information for the assessment of lung morphometry at the alveolar level, whereas the chemical shift saturation recovery (CSSR) technique can evaluate the gas exchange func...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3730

    authors: Zhong J,Zhang H,Ruan W,Xie J,Li H,Deng H,Han Y,Sun X,Ye C,Zhou X

    更新日期:2017-08-01 00:00:00

  • Studies of metabolic compartmentation and glucose transport using in vivo MRS.

    abstract::Organs consist of several types of cells with specialized functions. This cellular localization of function is often referred to as compartmentation. Due to the intrinsic low sensitivity of MR methods it is generally not possible in vivo to obtain images or spectra of single cells. Instead the MRS signal is the sum of...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.692

    authors: Rothman DL

    更新日期:2001-04-01 00:00:00

  • Measuring SPIO and Gd contrast agent magnetization using 3 T MRI.

    abstract::Traditional methods of measuring magnetization in magnetic fluid samples, such as vibrating sample magnetometry (VSM), are typically limited to maximum field strengths of about 1 T. This work demonstrates the ability of MRI to measure the magnetization associated with two commercial MRI contrast agents at 3 T by compa...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1412

    authors: Cantillon-Murphy P,Wald LL,Zahn M,Adalsteinsson E

    更新日期:2009-10-01 00:00:00

  • Acquisition of ³He ventilation images, ADC, T₂* and B₁ maps in a single scan with compressed sensing.

    abstract::In imaging of human lungs with hyperpolarised noble gases, measurements of apparent diffusion coefficient (ADC) and relaxation time provide valuable information for the assessment of lung microstructure. In this work, a sequence was developed for interleaved acquisition of ventilation images, ADC, T(2)* and flip angle...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1710

    authors: Ajraoui S,Parra-Robles J,Marshall H,Deppe MH,Clemence M,Wild JM

    更新日期:2012-01-01 00:00:00

  • Pattern recognition analysis of directional intravoxel incoherent motion MRI in ischemic rodent brains.

    abstract::This study aimed to demonstrate a reliable automatic segmentation method for independently separating reduced diffusion and decreased perfusion areas in ischemic stroke brains using constrained nonnegative matrix factorization (cNMF) pattern recognition in directional intravoxel incoherent motion MRI (IVIM-MRI). First...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4268

    authors: Jang M,Jin S,Kang M,Han S,Cho H

    更新日期:2020-05-01 00:00:00

  • DTI of human skeletal muscle: the effects of diffusion encoding parameters, signal-to-noise ratio and T2 on tensor indices and fiber tracts.

    abstract::In this study, we have performed simulations to address the effects of diffusion encoding parameters, signal-to-noise ratio (SNR) and T2 on skeletal muscle diffusion tensor indices and fiber tracts. Where appropriate, simulations were corroborated and validated by in vivo diffusion tensor imaging (DTI) of human skelet...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2959

    authors: Froeling M,Nederveen AJ,Nicolay K,Strijkers GJ

    更新日期:2013-11-01 00:00:00

  • MRI of lung parenchyma in rats and mice using a gradient-echo sequence.

    abstract::Signal of lung parenchymal tissue from the living rat and mouse lung was detected at 4.7 T with a good signal-to-noise ratio and motion-suppressed artifacts using a short TE gradient-echo sequence. Neither cardiac nor respiratory gating were applied, and animals respired freely during data collection. Mean T(2)* relax...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.706

    authors: Beckmann N,Tigani B,Mazzoni L,Fozard JR

    更新日期:2001-08-01 00:00:00

  • Metabolite-specific NMR spectroscopy in vivo.

    abstract::An outline is presented of metabolite-specific in vivo NMR spectroscopy (particularly in brain). It reviews from a physical spectroscopist's perspective, the need for and the methods of observation of, individual metabolite resonances. ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/(sici)1099-1492(199712)10:8<435::aid-nbm48

    authors: Allen PS,Thompson RB,Wilman AH

    更新日期:1997-12-01 00:00:00

  • 13C NMR spectroscopic analysis of phospholipid metabolism in adrenal chromaffin cells.

    abstract::Phosphatidylcholine (PC) metabolism in bovine adrenal chromaffin cells has been studied in vivo with 100 MHz 13C NMR spectroscopy. The incorporation of 13[CH3]choline was examined in cells embedded in 1% agarose strands and perfused at 37 degrees C. The pattern of 13C NMR spectroscopy. The incorporation of [13CH3]chol...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1940040304

    authors: Rivera CJ,Plishker GA,Morrisett JD,Moore J,Percy AK

    更新日期:1991-06-01 00:00:00

  • Altered functional brain networks in Prader-Willi syndrome.

    abstract::Prader-Willi syndrome (PWS) is a genetic imprinting disorder characterized mainly by hyperphagia and early childhood obesity. Previous functional neuroimaging studies used visual stimuli to examine abnormal activities in the eating-related neural circuitry of patients with PWS. It was found that patients with PWS exhi...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.2900

    authors: Zhang Y,Zhao H,Qiu S,Tian J,Wen X,Miller JL,von Deneen KM,Zhou Z,Gold MS,Liu Y

    更新日期:2013-06-01 00:00:00

  • 1H NMR spin-echo spectroscopy of human erythrocytes. Transformation of exogenous compounds.

    abstract::1H NMR spin-echo spectroscopy has been used to study the metabolism of exogenous compounds in human erythrocytes. The non-invasive nature of the technique and the continuous monitoring makes it ideal to investigate both the conversion of substrates and the occurrence and the nature of the products. Hydrolysis rates ma...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1940030603

    authors: Skibsted U,Hansen PE

    更新日期:1990-12-01 00:00:00

  • Structural and resting-state MRI detects regional brain differences in young and mid-age healthy APOE-e4 carriers compared with non-APOE-e4 carriers.

    abstract::The presence of the e4 allele of the apolipoprotein E (APOE) gene is the best-known genetic risk factor for Alzheimer's disease. In this study, we investigated the link between functional and behavioural differences and regional brain volume and cortical thickness differences in those who carry the e4 allele (e4+) and...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3502

    authors: Dowell NG,Evans SL,Tofts PS,King SL,Tabet N,Rusted JM

    更新日期:2016-05-01 00:00:00

  • Signal-to-noise ratio of a mouse brain (13) C CryoProbe™ system in comparison with room temperature coils: spectroscopic phantom and in vivo results.

    abstract::MRI and MRS in small rodents demand very high sensitivity. Cryogenic transmit/receive radiofrequency probes (CryoProbes) designed for (1) H MRI of mouse brain provide an attractive option for increasing the performance of small-animal MR systems. As the Larmor frequency of (13) C nuclei is four times lower than that f...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3110

    authors: Sack M,Wetterling F,Sartorius A,Ende G,Weber-Fahr W

    更新日期:2014-06-01 00:00:00

  • Quantification of disease progression in spinal muscular atrophy with muscle MRI-a pilot study.

    abstract:OBJECTIVES:Quantitative MRI (qMRI) of muscles is a promising tool to measure disease progression or to assess therapeutic effects in neuromuscular diseases. Longitudinal imaging studies are needed to show sensitivity of qMRI in detecting disease progression in spinal muscular atrophy (SMA). In this pilot study we there...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4473

    authors: Otto LAM,Froeling M,van Eijk RPA,Asselman FL,Wadman R,Cuppen I,Hendrikse J,van der Pol WL

    更新日期:2021-01-22 00:00:00

  • Glioma grading using apparent diffusion coefficient map: application of histogram analysis based on automatic segmentation.

    abstract::The accurate diagnosis of glioma subtypes is critical for appropriate treatment, but conventional histopathologic diagnosis often exhibits significant intra-observer variability and sampling error. The aim of this study was to investigate whether histogram analysis using an automatically segmented region of interest (...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3153

    authors: Lee J,Choi SH,Kim JH,Sohn CH,Lee S,Jeong J

    更新日期:2014-09-01 00:00:00

  • Dynamic 2D and 3D mapping of hyperpolarized pyruvate to lactate conversion in vivo with efficient multi-echo balanced steady-state free precession at 3 T.

    abstract::The aim of this study was to acquire the transient MRI signal of hyperpolarized tracers and their metabolites efficiently, for which specialized imaging sequences are required. In this work, a multi-echo balanced steady-state free precession (me-bSSFP) sequence with Iterative Decomposition with Echo Asymmetry and Leas...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4291

    authors: Müller CA,Hundshammer C,Braeuer M,Skinner JG,Berner S,Leupold J,Düwel S,Nekolla SG,Månsson S,Hansen AE,von Elverfeldt D,Ardenkjaer-Larsen JH,Schilling F,Schwaiger M,Hennig J,Hövener JB

    更新日期:2020-06-01 00:00:00

  • Chemotherapy-associated changes in 31P MRS spectra of sera from patients with multiple myeloma.

    abstract::31P NMR spectra were obtained from sera of 22 healthy volunteers and 20 patients with multiple myeloma at the time of diagnosis and repeated up to five times during therapy. All spectra consisted of a Pi peak (used as a reference peak) and two peaks from phospholipids (PL): one peak due to phosphatidylethanolamine and...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1940080308

    authors: Kuliszkiewicz-Janus M,Baczyński S

    更新日期:1995-05-01 00:00:00

  • Differences in metabolism of 5-fluorouracil and 5-fluorouridine and regulation by glucosamine in human colon cancer multicell tumor spheroids.

    abstract::Glucosamine (GlcN) modulates fluoropyrimidine metabolism and enhances cytotoxicity of 5-fluorouridine (FUrd), but not of 5-fluorouracil (FUra), in human tumor models. To elucidate the underlying metabolic differences between FUra and FUrd, by the use of 19F and 31P NMR spectroscopy we studied these drugs in multicell ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/(sici)1099-1492(199905)12:3<157::aid-nbm55

    authors: Chen TB,Bajzer Z,Macura S,Vuk-Pavlovic S

    更新日期:1999-05-01 00:00:00

  • Effect of taxane-based neoadjuvant chemotherapy on fibroglandular tissue volume and percent breast density in the contralateral normal breast evaluated by 3T MR.

    abstract::The aim of this study was to evaluate the change of breast density in the normal breast of patients receiving neoadjuvant chemotherapy (NAC). Forty-four breast cancer patients were studied. MRI acquisition was performed before treatment (baseline), and 4 and 12 weeks after treatment. A computer-algorithm-based program...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3006

    authors: Chen JH,Pan WF,Kao J,Lu J,Chen LK,Kuo CC,Chang CK,Chen WP,McLaren CE,Bahri S,Mehta RS,Su MY

    更新日期:2013-12-01 00:00:00

  • Apparent diffusion coefficient of the prostate in men prior to biopsy: determination of a cut-off value to predict malignancy of the peripheral zone.

    abstract::Determination of the apparent diffusion coefficient (ADC) of the prostate in men (n = 60) with raised prostate-specific antigen (PSA) or an abnormal digital rectal examination (DRE) prior to transrectal ultrasound (TRUS) guided biopsy using endorectal DWI is reported. Patients were categorized into different groups ba...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1114

    authors: Kumar V,Jagannathan NR,Kumar R,Thulkar S,Gupta SD,Dwivedi SN,Hemal AK,Gupta NP

    更新日期:2007-08-01 00:00:00

  • Physiological variation of the vertebral bone marrow water T2 relaxation time.

    abstract::The aim of this study was to investigate physiological variations of the water T2 relaxation time in vertebral bone marrow with respect to age, body mass index (BMI), sex and proton density fat fraction (PDFF) based on single-voxel magnetic resonance spectroscopy (MRS) at 3 T. Multi-TE single-voxel STEAM MRS data of a...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.4439

    authors: Ruschke S,Syväri J,Dieckmeyer M,Junker D,Makowski MR,Baum T,Karampinos DC

    更新日期:2020-11-17 00:00:00

  • Regional neurochemical profiles in the human brain measured by ¹H MRS at 7 T using local B₁ shimming.

    abstract::Increased sensitivity and chemical shift dispersion at ultra-high magnetic fields enable the precise quantification of an extended range of brain metabolites from (1)H MRS. However, all previous neurochemical profiling studies using single-voxel MRS at 7 T have been limited to data acquired from the occipital lobe wit...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1727

    authors: Emir UE,Auerbach EJ,Van De Moortele PF,Marjańska M,Uğurbil K,Terpstra M,Tkáč I,Oz G

    更新日期:2012-01-01 00:00:00

  • Clinical experience with 13C MRS in vivo.

    abstract::13C MRS was installed on a clinical scanner at 1.5 T in order to facilitate integrated MR examinations of human brain disorders. Using a simplified protocol, (1-(13)C) glucose and/or (1-(13)C) acetate were administered orally or by intravenous infusion. (13)C spectra of diagnostic quality were acquired in more than 10...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.852

    authors: Ross B,Lin A,Harris K,Bhattacharya P,Schweinsburg B

    更新日期:2003-10-01 00:00:00

  • Localized 1H NMR spectroscopy in different regions of human brain in vivo at 7 T: T2 relaxation times and concentrations of cerebral metabolites.

    abstract::At the high field strength of 7 T, in vivo spectra of the human brain with exceptional spectral quality sufficient to quantify 16 metabolites have been obtained previously only in the occipital lobe. However, neurochemical abnormalities associated with many brain disorders are expected to occur in brain structures oth...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1754

    authors: Marjańska M,Auerbach EJ,Valabrègue R,Van de Moortele PF,Adriany G,Garwood M

    更新日期:2012-02-01 00:00:00

  • Measurement of tumor blood flow by deuterium NMR and the effects of modifiers.

    abstract::Tumor metabolism is directly coupled to tumor blood flow (TBF) and both metabolism and blood flow may be determinants of tumor response to treatment. Since NMR has been used extensively to monitor tumor metabolism noninvasively, development of NMR-based methods for TBF measurement was motivated by the desire to examin...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章,评审

    doi:10.1002/nbm.1940050516

    authors: Evelhoch JL

    更新日期:1992-09-01 00:00:00

  • Concurrent recording of RF pulses and gradient fields - comprehensive field monitoring for MRI.

    abstract::Reconstruction of MRI data is based on exact knowledge of all magnetic field dynamics, since the interplay of RF and gradient pulses generates the signal, defines the contrast and forms the basis of resolution in spatial and spectral dimensions. Deviations caused by various sources, such as system imperfections, delay...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3359

    authors: Brunner DO,Dietrich BE,Çavuşoğlu M,Wilm BJ,Schmid T,Gross S,Barmet C,Pruessmann KP

    更新日期:2016-09-01 00:00:00

  • Monitoring response to chemotherapy of non-Hodgkin's lymphoma xenografts by T(2)-weighted and diffusion-weighted MRI.

    abstract::An effective method for in vivo detection of early therapeutic response of patients with non-Hodgkin's lymphoma would enable personalized clinical management of cancer therapy and facilitate the design of optimal treatment regimens. This study evaluates the feasibility of T(2)-weighted MRI (T2WI) and diffusion-weighte...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.1261

    authors: Huang MQ,Pickup S,Nelson DS,Qiao H,Xu HN,Li LZ,Zhou R,Delikatny EJ,Poptani H,Glickson JD

    更新日期:2008-11-01 00:00:00

  • Requirements for static and dynamic higher order B0 shimming of the human breast at 7 T.

    abstract::The increased magnetic susceptibility effects at higher magnetic fields increase the demands for shimming of the B0 field for in vivo MRI and MRS. Both static and dynamic techniques have been developed to compensate for susceptibility-induced field inhomogeneities. In this study, we investigate the impact of and need ...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3096

    authors: Boer VO,Luttje MP,Luijten PR,Klomp DW

    更新日期:2014-06-01 00:00:00

  • Characterization of a rat orthotopic pancreatic head tumor model using three-dimensional and quantitative multi-parametric MRI.

    abstract::The purpose of this study was to investigate the reliability of 3D isotropic MRI and quantitative multi-parametric MRI characterization on an orthotopic pancreatic head tumor model in rats. 3D isotropic T2 -weighted MRI was performed as a routine for tumor longitudinal follow-up and volume estimation. Common bile duct...

    journal_title:NMR in biomedicine

    pub_type: 杂志文章

    doi:10.1002/nbm.3676

    authors: Yin T,Peeters R,Feng Y,Liu Y,Yu J,Dymarkowski S,Himmelreich U,Oyen R,Ni Y

    更新日期:2017-02-01 00:00:00