A hierarchical approach in the diagnostic workflow of chronic myelomonocytic leukemia: Pivotal role of the "Mono-dysplasia-score" combined with flow cytometric quantification of monocyte subsets.

Abstract:

INTRODUCTION:Monocytosis is a frequent trigger for blood smear review in a routine hematology laboratory whereas chronic myelomonocytic leukemia (CMML) is infrequent and arises mostly in elderly patients. In order to define the best workflow for monocytosis, we studied three diagnostic approaches: the classical morphology approach (blood smear review), the flow cytometry assay (quantification of monocyte subsets as described by Selimoglu-Buet et al in 2015), and the "mono-dysplasia-score" also referred to as "Monoscore (as described by our team in 2018 using the structural parameters of the Sysmex XN™ analyzers). METHODS:Studying a multicentric cohort of 196 nonclonal monocytoses and CMML patients aged over 50 years, we compared the diagnostic performance of the three approaches alone and in combination to propose a diagnostic decision tree. RESULTS:In patients presenting with additional criteria for slide review to monocytosis (37% of our cohort), we propose to sequentially combine morphology, Monoscore, and flow cytometry. On the contrary, for patients with isolated monocytosis (63%), slide review is not mandatory and we suggest performing flow cytometry depending on the Monoscore value. Using the proposed algorithm, 98% of CMML patients would have been correctly identified, slide review rate drastically reduced, and flow cytometry would have been carried out in 44% of patients. CONCLUSION:We have shown that implementation of Monoscore is a useful input filter to significantly reduce slide reviews without losing sensitivity and that flow cytometry is a performant technique in the second step of the diagnostic workup of CMML.

journal_name

Int J Lab Hematol

authors

Zhu J,Sourdeau E,Aubert H,Clauser S,Maillon A,Capron C,Jondeau K,Ronez E,Schillinger F,Garnache-Ottou F,Cornet E,Bardet V

doi

10.1111/ijlh.13115

subject

Has Abstract

pub_date

2019-12-01 00:00:00

pages

782-790

issue

6

eissn

1751-5521

issn

1751-553X

journal_volume

41

pub_type

杂志文章
  • The impact of long-haul air travel on variables of the athlete's biological passport.

    abstract:INTRODUCTION:Dehydration, fluid shifts or changes in coagulation occurring during air travel can trigger distinct reactions in the haematological system. Athletes are concerned that these effects might impair sporting performance, increase the risk of thrombosis or cause abnormalities in blood values that might be mist...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01450.x

    authors: Schumacher YO,Klodt F,Nonis D,Pottgiesser T,Alsayrafi M,Bourdon PC,Voss SC

    更新日期:2012-12-01 00:00:00

  • Current and emerging approaches for evaluating platelet disorders.

    abstract::Platelets play a central role in physiological hemostasis and also in pathological thrombosis. It is well established that congenital or acquired abnormalities of platelet function are associated with a heightened risk of bleeding of variable severity and excessive hemorrhage after surgery or trauma. Several kinds of ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12539

    authors: Podda G,Femia EA,Cattaneo M

    更新日期:2016-05-01 00:00:00

  • The immature platelet fraction is a useful marker for predicting the timing of platelet recovery in patients with cancer after chemotherapy and hematopoietic stem cell transplantation.

    abstract::Prediction of the timing of platelet recovery after chemotherapy and hematopoietic stem cell transplantation (HSCT) allows for optimal platelet transfusion. We assessed the clinical utility of the percentage value of the immature platelet fraction (IPF%) monitored using an XE-2100 automated hematology analyzer to pred...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01232.x

    authors: Yamaoka G,Kubota Y,Nomura T,Inage T,Arai T,Kitanaka A,Saigo K,Iseki K,Baba N,Taminato T

    更新日期:2010-12-01 00:00:00

  • Inappropriate use of protein C, protein S, and antithrombin testing for hereditary thrombophilia screening: an experience from a large university hospital.

    abstract:INTRODUCTION:Deficiencies of protein C, protein S, and antithrombin are the main inherited risk factors in Thai patients with venous thromboembolism, although the prevalence is not high. METHODS:To evaluate the appropriate use of the testing for these proteins, the test orders of 503 patients were retrospectively revi...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01332.x

    authors: Tientadakul P,Chinthammitr Y,Sanpakit K,Wongwanit C,Nilanont Y

    更新日期:2011-12-01 00:00:00

  • Multicentric evaluation of the new HemosIL Acustar® chemiluminescence ADAMTS13 activity assay.

    abstract:INTRODUCTION:Thrombotic thrombocytopenic purpura (TTP) is a rare life-threatening thrombotic microangiopathy (TMA) characterized by the severe deficiency of ADAMTS13 activity (<10%). Rapid ADAMTS13 testing is crucial for early diagnosis and optimal management of TTP patients and other TMAs. The objective of this study ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13414

    authors: Pascual C,Nieto JM,Fidalgo T,Seguí IG,Díaz-Ricart M,Docampo MF,Del Rio J,Salinas R

    更新日期:2020-12-02 00:00:00

  • The evaluation of the relevance of thrombin generation and procoagulant activity in thrombotic risk assessment in BCR-ABL-negative myeloproliferative neoplasm patients.

    abstract:INTRODUCTION:It has been recently suggested that microparticles (MP) play a role in the pathogenesis of thrombotic complications. This study aimed to assess the contribution of procoagulant activity expressed by circulating MP in thrombotic events in MPN patients. METHODS:Seventy-four MPN patients were enrolled in a t...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12676

    authors: Baccouche H,Ben Jemaa M,Chakroun A,Chadi S,Mahjoub S,Sfar I,Gorgi Y,Ben Romdhane N

    更新日期:2017-10-01 00:00:00

  • CD34, RAB20, PU.1 and GFI1 mRNA expression in myelodysplastic syndrome.

    abstract::Myelodysplastic syndrome (MDS) with hypocellular bone marrow (BM) is often difficult to distinguish from aplastic anemia (AA). Furthermore, the diagnosis of MDS with low blast counts and normal karyotype may be problematic. These issues highlight the need for a reliable marker for the diagnosis of MDS. This study was ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2008.01056.x

    authors: Huh HJ,Chae SL,Lee M,Hong KS,Mun YC,Seong CM,Chung WS,Huh JW

    更新日期:2009-06-01 00:00:00

  • Validation of reflex testing rules and establishment of a new workflow for body fluid cell analysis using a Sysmex XN-550 automatic hematology analyzer.

    abstract:INTRODUCTION:We developed and validated reflex testing rules for the microscopic examination (ME) of body fluids (BFs) on the Sysmex XN-550 (Sysmex Corporation) instrument. METHODS:We assessed the detection limits, precision, linearity, and carryover. To develop the reflex testing rules (derivation arm), we tested 515...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12774

    authors: Cho YU,You E,Jang S,Park CJ

    更新日期:2018-06-01 00:00:00

  • Factor XIII-A subunit Val34Leu polymorphism in fatal hemorrhagic stroke.

    abstract::Blood coagulation factor XIII (FXIII) plays a key role in the protection of fibrin clot against fibrinolysis, in the cross-linking of fibrin and its mechanical strength. The role of the FXIII-A subunit Val34Leu polymorphism with fatal primary intracerebral hemorrhages (PICH) has not been studied. We evaluated retrospe...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01465.x

    authors: Antalfi B,Pongrácz E,Csiki Z,Mezei ZA,Shemirani AH

    更新日期:2013-02-01 00:00:00

  • Optimal wavelength for the clot waveform analysis: Determination of the best resolution with minimal interference of the reagents.

    abstract:INTRODUCTION:Clot waveform analysis (CWA), a new methodology to assess coagulation process, can be usefully applied in various clinical settings. However, its clinical use is limited mainly because of the absence of standardization. No consensus exists regarding the wavelengths at which CWA has to be performed what is ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12975

    authors: Evrard J,Siriez R,Morimont L,Thémans P,Laloy J,Bouvy C,Gheldof D,Mullier F,Dogné JM,Douxfils J

    更新日期:2019-06-01 00:00:00

  • How I investigate Eosinophilia.

    abstract::Eosinophilia is typically secondary, that is, reactive, in nature and is associated with a wide variety of neoplastic and non-neoplastic disorders. Clonal eosinophilia is also seen in a wide variety of hematopoietic neoplasms, and sub-classification can be diagnostically challenging. A proper evaluation of persistent ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12955

    authors: Larsen RL,Savage NM

    更新日期:2019-04-01 00:00:00

  • The hematology laboratory's response to the COVID-19 pandemic: A scoping review.

    abstract::The ongoing COVID-19 pandemic has had a profound worldwide impact on the laboratory hematology community. Nevertheless, the pace of COVID-19 hematology-related research has continued to accelerate and has established the role of laboratory hematology data for many purposes including disease prognosis and outcome. The ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13381

    authors: Bell R,Zini G,d'Onofrio G,Rogers HJ,Lee YS,Frater JL

    更新日期:2020-11-12 00:00:00

  • Limitation of the activated partial thromboplastin time as a monitoring method of the direct thrombin inhibitor argatroban.

    abstract:BACKGROUND:Argatroban is licensed for patients with heparin-induced thrombocytopenia and monitoring is conventionally by activated partial thromboplastin time (APTT) ratio with a target of 1.5-3.0 and not exceeding 100 s. The APTT may be influenced by coagulopathies, lupus anticoagulant and raised FVIII levels. Variabl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12414

    authors: Guy S,Kitchen S,Maclean R,Van Veen JJ

    更新日期:2015-12-01 00:00:00

  • The role of automated measurement of red cell subpopulations on the Sysmex XE 5000 analyzer in the differential diagnosis of microcytic anemia.

    abstract::Cell counter-based formulae have been used in the differential diagnosis of microcytic anemia. The measurement of new red cell parameters is now available on the Sysmex XE 5000 analyzer. Derived from the percentages of microcytic and hypochromic red cells, the authors describe the new formula %microcytic-%hypochromic,...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01237.x

    authors: Urrechaga E,Borque L,Escanero JF

    更新日期:2011-02-01 00:00:00

  • Performance evaluation of the PENTRA 60C+ automated hematology analyzer and comparison with the ADVIA 2120.

    abstract::The PENTRA 60C(+) hematology analyzer provides a complete blood cell (CBC) count, including a five-part differential (5-DIFF) count and two leukocyte subpopulations, i.e. large immature cells (LIC's) and atypical lymphocytes (ALY's). We evaluated its analytical performance and assessed agreement with the ADVIA 2120, i...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.01011.x

    authors: Guerti K,Vertessen F,Daniëls L,Van Der Planken M

    更新日期:2009-04-01 00:00:00

  • Analytical comparison between two hematological analyzer systems: CAL-8000 vs. XN-9000.

    abstract:INTRODUCTION:This study was aimed to compare the analytical performance of traditional and new parameters and morphological flags of CAL-8000 and XN-9000. The automated differential leukocyte count (DIFF profile) and morphological flags were compared with optical microscopy (OM). METHODS:A total of 1025 peripheral blo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12597

    authors: Buoro S,Mecca T,Seghezzi M,Manenti B,Azzarà G,Dominoni P,Crippa A,Ottomano C,Lippi G

    更新日期:2017-04-01 00:00:00

  • Acute myeloid leukaemia: How to combine multiple tools.

    abstract::The pathogenesis of acute myeloid leukaemias (AML) frequently requires at least 3 mutations in different cellular pathways. In many cases, mutations in proliferation/survival mechanisms and differentiation pathways are involved. Genetic aberrations explain the pathogenesis of AML, provide prognostic criteria and guide...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12831

    authors: Merino A,Boldú L,Ermens A

    更新日期:2018-05-01 00:00:00

  • Assessing nonvitamin K antagonist oral anticoagulants (NOACs) in the laboratory.

    abstract::Nonvitamin K antagonist oral anticoagulants (NOACs) are being used with increasing frequency due to their safety profile, ease of use, and given that therapeutic monitoring is not required. As these agents have only recently been FDA approved, their effect on routine and specialty coagulation assays is not well apprec...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12350

    authors: Gosselin RC,Adcock DM

    更新日期:2015-05-01 00:00:00

  • Evaluation of the leukocyte differential on a new automated flow cytometry hematology analyzer.

    abstract:INTRODUCTION:The Hematoflow (Beckman Coulter, USA) is a new automated hematology analyzer, which provides a 16-part white blood cell count (WBC) differential. METHODS:We evaluated the differential WBC count performance of the Hematoflow. 101 blood samples from patients were selected for comparison analysis. RESULTS:T...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01432.x

    authors: Kim JE,Kim BR,Woo KS,Han JY

    更新日期:2012-10-01 00:00:00

  • DOAC plasma levels measured by chromogenic anti-Xa assays and HPLC-UV in apixaban- and rivaroxaban-treated patients from the START-Register.

    abstract:INTRODUCTION:To measure direct factor Xa inhibitor (apixaban, edoxaban, rivaroxaban) concentrations, dedicated chromogenic anti-Xa assays are recommended as suitable methods to provide rapid drug quantification. Moreover, the high-performance liquid chromatography with ultraviolet detection (HPLC-UV) is reported as a r...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13159

    authors: Cini M,Legnani C,Padrini R,Cosmi B,Dellanoce C,De Rosa G,Marcucci R,Pengo V,Poli D,Testa S,Palareti G

    更新日期:2020-04-01 00:00:00

  • ADAMTS13 activity to von Willebrand factor antigen ratio predicts acute kidney injury in patients with COVID-19: Evidence of SARS-CoV-2 induced secondary thrombotic microangiopathy.

    abstract:INTRODUCTION:Severe COVID-19 is often compounded by a prothrombotic state that is associated with poor outcomes. In this investigation, we aimed to evaluate ADAMTS13 activity, von Willebrand factor level (VWF:Ag), and the corresponding ADAMTS13 activity/VWF:Ag ratio, in patients with COVID-19 and for associations with ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13415

    authors: Henry BM,Benoit SW,de Oliveira MHS,Lippi G,Favaloro EJ,Benoit JL

    更新日期:2020-12-03 00:00:00

  • The mutual control of iron and erythropoiesis.

    abstract:BACKGROUND:Iron is essential for hemoglobin synthesis during terminal erythropoiesis. To supply adequate iron the carrier transferrin is required together with transferrin receptor endosomal cycle and normal mitochondrial iron utilization. Iron and iron protein deficiencies result in different types of anemia. Iron-def...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12505

    authors: Camaschella C,Pagani A,Nai A,Silvestri L

    更新日期:2016-05-01 00:00:00

  • Performance evaluation of a new Stago® automated haemostasis analyser: The STA R Max® 2.

    abstract:INTRODUCTION:The STA R Max® 2 is a new coagulation analyser developed by Diagnostica Stago, able to perform clotting, chromogenic and immuno-turbidimetric tests. A pre-analytical module build into the cap-piercing needle performs the sample integrity verification (sample tube filling and measurement of haemolysis, icte...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13100

    authors: Cupaiolo R,Govaerts D,Blauwaert M,Cauchie P

    更新日期:2019-12-01 00:00:00

  • Red cell membrane disorders.

    abstract::Significant advances have been made in our understanding of the structural basis for altered cell function in various inherited red cell membrane disorders with reduced red cell survival and resulting hemolytic anemia. The current review summarizes these advances as they relate to defining the molecular and structural...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12657

    authors: Narla J,Mohandas N

    更新日期:2017-05-01 00:00:00

  • Establishment of reference interval for immature platelet fraction.

    abstract:INTRODUCTION:Immature platelet fraction (IPF) is a parameter for reticulated platelets. A high percentage IPF (%-IPF) is indicative of consumptive or recovering thrombocytopenic disorders in contrast to a low %-IPF seen in aplastic states. Absolute IPF (A-IPF) specifically reflects the number of immature platelets in c...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12049

    authors: Ko YJ,Kim H,Hur M,Choi SG,Moon HW,Yun YM,Hong SN

    更新日期:2013-10-01 00:00:00

  • Morphologic and cytogenetic variables affect the flow cytometric recovery of plasma cell myeloma cells in bone marrow aspirates.

    abstract:INTRODUCTION:It is widely recognized that plasma cells (PCs) are under-represented in flow cytometry (FC) studies, but the causes of this phenomenon are poorly understood. We sought to study potential variables that affect PC recovery by flow cytometry (FC) in the analysis of plasma cell myeloma (PCM). METHODS:We retr...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12411

    authors: Cogbill CH,Spears MD,Vantuinen P,Harrington AM,Olteanu H,Kroft SH

    更新日期:2015-12-01 00:00:00

  • Flow cytometry in the diagnosis of mature B-cell lymphoproliferative disorders.

    abstract::B-lineage lymphoproliferative disorders (LPD) are rather frequent diseases, associated with specific clinical or biological features but also sometimes of fortuitous discovery. Multiparameter flow cytometry plays a major role for a rapid diagnostic indication, on peripheral blood or bone marrow samples in most instanc...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13170

    authors: Debord C,Wuillème S,Eveillard M,Theisen O,Godon C,Le Bris Y,Béné MC

    更新日期:2020-06-01 00:00:00

  • Comparison of five point-of-care D-dimer assays with the standard laboratory method.

    abstract:INTRODUCTION:D-dimer (DD) assays are effective for the exclusion of deep-vein thrombosis (DVT), but point-of-care (POC) DD assays have not been fully evaluated. METHODS:We have compared five POC DD assays (Pathfast, Cardiac, Vidas, Stratus and NycoCard) with our routine DD method (Tinaquant), testing 60 samples from p...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01421.x

    authors: Antovic JP,Höög Hammarström K,Forslund G,Eintrei J,Sten-Linder M

    更新日期:2012-10-01 00:00:00

  • Morphologic identification of atypical chronic lymphocytic leukemia by digital microscopy.

    abstract:INTRODUCTION:Atypical chronic lymphocytic leukemia (aCLL) is a morphologic variant found in approximately 25% of patients with chronic lymphocytic leukemia (CLL). Although aCLL has a more aggressive course compared to typical CLL (tCLL), it is not usually reported. This retrospective study used digital microscopy to mo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12167

    authors: Marionneaux S,Maslak P,Keohane EM

    更新日期:2014-08-01 00:00:00

  • Osmotic gradient ektacytometry: A valuable screening test for hereditary spherocytosis and other red blood cell membrane disorders.

    abstract:INTRODUCTION:New generation osmotic gradient ektacytometry has become a powerful procedure for measuring red blood cell deformability and therefore for the diagnosis of red blood cell membrane disorders. In this study, we aim to provide further support to the usefulness of osmotic gradient ektacytometry for the differe...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章

    doi:10.1111/ijlh.12746

    authors: Llaudet-Planas E,Vives-Corrons JL,Rizzuto V,Gómez-Ramírez P,Sevilla Navarro J,Coll Sibina MT,García-Bernal M,Ruiz Llobet A,Badell I,Velasco-Puyó P,Dapena JL,Mañú-Pereira MM

    更新日期:2018-02-01 00:00:00