Red cell membrane disorders.

Abstract:

:Significant advances have been made in our understanding of the structural basis for altered cell function in various inherited red cell membrane disorders with reduced red cell survival and resulting hemolytic anemia. The current review summarizes these advances as they relate to defining the molecular and structural basis for disorders involving altered membrane structural organization (hereditary spherocytosis [HS] and hereditary elliptocytosis [HE]) and altered membrane transport function (hereditary overhydrated stomatocytosis and hereditary xerocytosis). Mutations in genes encoding membrane proteins that account for these distinct red cell phenotypes have been identified. These molecular insights have led to improved understanding of the structural basis for altered membrane function in these disorders. Weakening of vertical linkage between the lipid bilayer and spectrin-based membrane skeleton leads to membrane loss in HS. In contrast, weakening of lateral linkages among different skeletal proteins leads to membrane fragmentation and decreased surface area in HE. The degrees of membrane loss and resultant increases in cell sphericity determine the severity of anemia in these two disorders. Splenectomy leads to amelioration of anemia by increasing the circulatory red cell life span of spherocytic red cells that are normally sequestered by the spleen. Disordered membrane cation permeability and resultant increase or decrease in red cell volume account for altered cellular deformability of hereditary overhydrated stomatocytosis and hereditary xerocytosis, respectively. Importantly, splenectomy is not beneficial in these two membrane transport disorders and in fact contraindicated due to severe postsplenectomy thrombotic complications.

journal_name

Int J Lab Hematol

authors

Narla J,Mohandas N

doi

10.1111/ijlh.12657

subject

Has Abstract

pub_date

2017-05-01 00:00:00

pages

47-52

eissn

1751-5521

issn

1751-553X

journal_volume

39 Suppl 1

pub_type

杂志文章,评审
  • Usefulness of automated fragmented red blood cell percentage in the diagnosis of paediatric haemolytic uraemic syndrome.

    abstract:INTRODUCTION:Presence of schistocytes in peripheral blood smear supporting haemolysis is important for diagnosis and decision-making in paediatric haemolytic uraemic syndrome (HUS). High observer dependency and requirement of expertise for peripheral smear evaluation propels us to think of other modalities to overcome ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13324

    authors: Govindarajan S,Bhatia P,Dawman L,Tiewsoh K

    更新日期:2021-02-01 00:00:00

  • Iron status determination in pregnancy using the Thomas plot.

    abstract:INTRODUCTION:Physiological changes during pregnancy affect routine tests for iron deficiency. The reticulocyte haemoglobin equivalent (RET-He) and serum-soluble transferrin receptor (sTfR) assay are newer diagnostic parameters for the detection of iron deficiency, combined in the Thomas diagnostic plot. We used this pl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12448

    authors: Weyers R,Coetzee MJ,Nel M

    更新日期:2016-04-01 00:00:00

  • Clinical performance evaluation of the new hematology analyzer Mindray BC-6000.

    abstract:INTRODUCTION:With the progression of blood analysis technology, hematology analyzers become more complex and diverse. How to choose a superb instrument is a challenge for the laboratories. In the essay, we studied whether the newest BC-6000 hematology analyzer meets the needs of a clinical hematology laboratory. METHO...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13075

    authors: Shen Y,Cao J,Zhou Z,Wang Y,Shen Y,He J

    更新日期:2019-10-01 00:00:00

  • Validation of reflex testing rules and establishment of a new workflow for body fluid cell analysis using a Sysmex XN-550 automatic hematology analyzer.

    abstract:INTRODUCTION:We developed and validated reflex testing rules for the microscopic examination (ME) of body fluids (BFs) on the Sysmex XN-550 (Sysmex Corporation) instrument. METHODS:We assessed the detection limits, precision, linearity, and carryover. To develop the reflex testing rules (derivation arm), we tested 515...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12774

    authors: Cho YU,You E,Jang S,Park CJ

    更新日期:2018-06-01 00:00:00

  • Novel chromosomal translocations in multiple myeloma: t(13;16)(q14;q24) and t(1;15)(q10;q26).

    abstract::Multiple myeloma (MM) is a malignant plasma cell disorder that involves multiple genetic abnormalities. Chimeric transcription factors, created by gene fusion as a result of chromosomal translocations, have been implicated in the pathogenesis of the disease. Here, we report the conventional cytogenetic analysis of a M...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2006.00837.x

    authors: Akalin I,Kutlay NY,Ilhan O,Tukun A

    更新日期:2007-06-01 00:00:00

  • The diagnostic and clinical impact of genetics and epigenetics in acute myeloid leukemia.

    abstract::Acute myeloid leukemia (AML) is a complex disease, for which our understanding of the role of genetic and epigenetic changes has undergone significant advancements. Newer diagnostic and prognostic classifications have increasingly incorporated such information, and novel therapies have been developed to target specifi...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12367

    authors: Ohgami RS,Arber DA

    更新日期:2015-05-01 00:00:00

  • JAK2V617F mutation in patients with thrombosis: to screen or not to screen?

    abstract:INTRODUCTION:Thrombotic complications are a main concern in patients with myeloproliferative neoplasms. Recently, a gain-of-function mutation of the gene encoding the JAK2 tyrosine kinase that results in a valine-to-phenylalanine substitution at position 617 (V617F) has been described. Since the description of the JAK2...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/j.1751-553X.2010.01275.x

    authors: Xavier SG,Gadelha T,Rezende SM,Zalcberg IR,Spector N

    更新日期:2011-04-01 00:00:00

  • Performance evaluation of a new Stago® automated haemostasis analyser: The STA R Max® 2.

    abstract:INTRODUCTION:The STA R Max® 2 is a new coagulation analyser developed by Diagnostica Stago, able to perform clotting, chromogenic and immuno-turbidimetric tests. A pre-analytical module build into the cap-piercing needle performs the sample integrity verification (sample tube filling and measurement of haemolysis, icte...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13100

    authors: Cupaiolo R,Govaerts D,Blauwaert M,Cauchie P

    更新日期:2019-12-01 00:00:00

  • How I investigate for bleeding disorders.

    abstract:INTRODUCTION:Laboratory investigations for bleeding disorders are warranted when an individual has a personal and/or family history of bleeding, and/or laboratory findings that suggest the possibility of an inherited or acquired bleeding disorder. METHODS:This review summarizes author's experience with ordering and re...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12822

    authors: Hayward CPM

    更新日期:2018-05-01 00:00:00

  • The mutual control of iron and erythropoiesis.

    abstract:BACKGROUND:Iron is essential for hemoglobin synthesis during terminal erythropoiesis. To supply adequate iron the carrier transferrin is required together with transferrin receptor endosomal cycle and normal mitochondrial iron utilization. Iron and iron protein deficiencies result in different types of anemia. Iron-def...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12505

    authors: Camaschella C,Pagani A,Nai A,Silvestri L

    更新日期:2016-05-01 00:00:00

  • Proteasome inhibitor bortezomib overcomes P-gp-mediated multidrug resistance in resistant leukemic cell lines.

    abstract:INTRODUCTION:To study the effect of bortezomib alone or in combination with daunorubicin (DNR) on an mdr1 single-factor drug-resistant leukemia cell line K562/MDR1, a multifactor-resistant cell line K562/A02, a drug-sensitive cell line K562, and primary cells from acute myeloid leukemia patients. METHODS:The cell line...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2011.01384.x

    authors: Zheng B,Zhou R,Gong Y,Yang X,Shan Q

    更新日期:2012-06-01 00:00:00

  • Strategies for basic laboratory diagnostics of the hemoglobinopathies in multi-ethnic societies: interpretation of results and pitfalls.

    abstract::The consistent multi-ethnic migrations of the last decades have considerably changed the epidemiology of the hemoglobinopathies. Healthy carriers of these conditions are present today in many nonendemic parts of the world, and severely affected children are now born where these diseases were previously rare or unknown...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12037

    authors: Giordano PC

    更新日期:2013-10-01 00:00:00

  • Real-world assay variability between laboratories in monitoring of recombinant factor IX Fc fusion protein activity in plasma samples.

    abstract:INTRODUCTION:Monitoring of factor IX (FIX) replacement therapy in haemophilia B relies on accurate coagulation assays. However, considerable interlaboratory variability has been reported for one-stage clotting (OSC) assays. This study aimed to evaluate the real-world, interlaboratory variability of routine FIX activity...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,多中心研究

    doi:10.1111/ijlh.13189

    authors: Sommer JM,Sadeghi-Khomami A,Barnowski C,Wikén M,Willemze AJ

    更新日期:2020-06-01 00:00:00

  • Abrogation of red blood cell G6PD enzyme activity through Heat treatment: development of survey material for the UK NEQAS G6PD scheme.

    abstract:INTRODUCTION:Participation in external quality assessment (EQA) is central to the maintenance of high-quality laboratory results in patient diagnosis and clinical trials. Laboratories in the TAF112582 DETECTIVE study (ClinicalTrials.gov identifier: NCT01376167) are enrolled in the United Kingdom National Quality Assess...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/ijlh.12627

    authors: Roper DR,De la Salle B,Soni V,Fletcher K,Green JA

    更新日期:2017-06-01 00:00:00

  • Performance evaluation of the PENTRA 60C+ automated hematology analyzer and comparison with the ADVIA 2120.

    abstract::The PENTRA 60C(+) hematology analyzer provides a complete blood cell (CBC) count, including a five-part differential (5-DIFF) count and two leukocyte subpopulations, i.e. large immature cells (LIC's) and atypical lymphocytes (ALY's). We evaluated its analytical performance and assessed agreement with the ADVIA 2120, i...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.01011.x

    authors: Guerti K,Vertessen F,Daniëls L,Van Der Planken M

    更新日期:2009-04-01 00:00:00

  • Evaluation of the CellaVision DM automated microscope in pediatrics.

    abstract::The DM is an automated microscope, which performs WBC differential counts and monitors red cell morphology. The user either validates the cell recognition if the DM has correctly identified the WBCs or reclassifies the WBCs in the good category in case of a DM mis-assignment. Morphological anomalies of leukocytes, red...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2009.01219.x

    authors: Billard M,Lainey E,Armoogum P,Alberti C,Fenneteau O,Da Costa L

    更新日期:2010-10-01 00:00:00

  • Optimal wavelength for the clot waveform analysis: Determination of the best resolution with minimal interference of the reagents.

    abstract:INTRODUCTION:Clot waveform analysis (CWA), a new methodology to assess coagulation process, can be usefully applied in various clinical settings. However, its clinical use is limited mainly because of the absence of standardization. No consensus exists regarding the wavelengths at which CWA has to be performed what is ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12975

    authors: Evrard J,Siriez R,Morimont L,Thémans P,Laloy J,Bouvy C,Gheldof D,Mullier F,Dogné JM,Douxfils J

    更新日期:2019-06-01 00:00:00

  • Expression of CD4 is correlated with an unfavorable prognosis in wild-type NPM1, FLT3-ITD-negative cytogenetically normal adult acute myeloid leukemia.

    abstract:INTRODUCTION:In the cytogenetically normal population of AML (CN-AML), FLT3-ITD-positive and wild-type NPM1 is correlated with a worse outcome, and FLT3-ITD-negative with NPM1-mut is correlated with a better outcome. This leaves a large subpopulation of CN-AML patients without NPM1 or FLT3-ITD mutations with heterogene...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12649

    authors: Guo RJ,Atenafu EG,Schimmer AD,Minden MD,Chang H

    更新日期:2017-08-01 00:00:00

  • Low expression of TET2 gene in pediatric acute lymphoblastic leukemia is associated with poor clinical outcome.

    abstract:INTRODUCTION:TET2, a member of the Ten-Eleven translocation gene family, catalyzes the conversion of 5-methylcytosine to 5-hydroxymethylcytosine in DNA. Low expression of TET2 has been reported as a prognostic factor for several types of malignancies in adult patients. However, there have been few data on the effect of...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13099

    authors: Zhang P,Weng WW,Chen P,Zhang Y,Ruan JF,Ba DD,Xu WQ,Tang YM

    更新日期:2019-10-01 00:00:00

  • Toward routine detection of extracellular vesicles in clinical samples.

    abstract::The majority, if not all, of human cell types secrete extracellular vesicles (EVs) into their environment, at least partly as a means of intercellular communication. These secreted vesicles can be detected in most bodily fluids including blood, urine, and saliva. The number of secreted vesicles and their composition i...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12247

    authors: van der Meel R,Krawczyk-Durka M,van Solinge WW,Schiffelers RM

    更新日期:2014-06-01 00:00:00

  • DOAC plasma levels measured by chromogenic anti-Xa assays and HPLC-UV in apixaban- and rivaroxaban-treated patients from the START-Register.

    abstract:INTRODUCTION:To measure direct factor Xa inhibitor (apixaban, edoxaban, rivaroxaban) concentrations, dedicated chromogenic anti-Xa assays are recommended as suitable methods to provide rapid drug quantification. Moreover, the high-performance liquid chromatography with ultraviolet detection (HPLC-UV) is reported as a r...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13159

    authors: Cini M,Legnani C,Padrini R,Cosmi B,Dellanoce C,De Rosa G,Marcucci R,Pengo V,Poli D,Testa S,Palareti G

    更新日期:2020-04-01 00:00:00

  • The importance of β globin deletion analysis in the evaluation of patients with β thalassemia.

    abstract:INTRODUCTION:Beta globin deletion/duplication analysis may serve as a useful adjunct to sequence analysis. Our purpose was to develop a robust assay for beta globin deletion/duplication analysis and determine its role in evaluating patients with beta thalassemia. METHODS:A single tube semi-quantitative fluorescent PCR...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01287.x

    authors: Mikula M,Buller-Burckle A,Gallivan M,Sun W,Franklin CR,Strom CM

    更新日期:2011-06-01 00:00:00

  • High-throughput on-chip leukemia diagnosis.

    abstract::Advances in lab-on-a-chip technologies enabled programmable, reconfigurable, and scalable manipulation of a variety of laboratory procedures. Samples, reagents, and fluids can be precisely controlled; buffer temperature, pH, and concentration control systems as well as a variety of detection systems can be integrated ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12054

    authors: Park S,Moon HS,Lee DS,Kim HC,Chun H

    更新日期:2013-10-01 00:00:00

  • International Council for Standardization in Haematology (ICSH) laboratory guidance for the evaluation of haemostasis analyser-reagent test systems. Part 1: Instrument-specific issues and commonly used coagulation screening tests.

    abstract::Before a new method is used for clinical testing, it is essential that it is evaluated for suitability for its intended purpose. This document gives guidance for the performance of verification, validation and implementation processes required by regulatory and accreditation bodies. It covers the planning and executio...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13411

    authors: Gardiner C,Coleman R,de Maat MPM,Dorgalaleh A,Echenagucia M,Gosselin RC,Ieko M,Kitchen S

    更新日期:2020-11-29 00:00:00

  • Assessing maternal clotting function with novel global coagulation assays: A prospective pilot study.

    abstract:INTRODUCTION:Women are at higher risk of venous thromboembolism (VTE) during pregnancy and the puerperium. Global coagulation assays (GCAs), including thromboelastography (TEG), thrombin generation using the calibrated automated thrombogram (CAT) and fibrin generation using the overall haemostatic potential assay (OHP)...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13389

    authors: O'Keefe D,Lim HY,Tham J,Ho P,Hui L

    更新日期:2020-11-10 00:00:00

  • A level-headed approach to measuring direct oral anticoagulants: A 2-year retrospective analysis of DOAC levels from a tertiary UK centre.

    abstract:INTRODUCTION:Direct oral anticoagulants (DOAC) are commonly prescribed and measuring drug levels may be useful in a number of contexts. However, data on DOAC level measurement and their clinical utility in real-world studies are limited. METHODS:We carried out a 2-year retrospective cohort study of DOAC levels measure...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12944

    authors: Denny NDR,Keighley L,Siganporia Z,Thachil J,Nash MJ

    更新日期:2019-04-01 00:00:00

  • Discrepancies between APTT results determined with different evaluation modes on automated coagulation analyzers.

    abstract::Modern photo-optical coagulometers collect optical data in the form of reaction curves and offer a possibility to determine clotting times at different points of clot formation by using different evaluation modes. The objectives of this study were to determine the possible impact of an evaluation mode on activated par...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2008.01111.x

    authors: Milos M,Herak DC,Zadro R

    更新日期:2010-02-01 00:00:00

  • IgG subclasses of FVIII inhibitors in an argentine cohort of severe hemophilia A patients: Analysis by flow cytometry.

    abstract:INTRODUCTION:FVIII inhibitors consist of a polyclonal population of antibodies. Previous studies have demonstrated different distribution of IgG subclasses. IgG4 was associated to high level of FVIII inhibitors and failure of immune tolerance induction (ITI) treatment. This study monitored the relative distribution of ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12696

    authors: Irigoyen MB,Primiani L,Felippo M,Candela M,de Bracco MME,Galassi NV

    更新日期:2017-12-01 00:00:00

  • Use of Sysmex XN-10 red blood cell parameters for screening of hereditary red blood cell diseases and iron deficiency anaemia.

    abstract:INTRODUCTION:In daily practice in haematology laboratories, red blood cell (RBC) abnormalities are frequent and their management is a real challenge. The aim of this study is to establish a "decision tree" using RBC and reticulocyte parameters from the SYSMEX XN-10 analyser to distinguish between patients with a heredi...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13278

    authors: Nivaggioni V,Bouriche L,Coito S,Le Floch AS,Ibrahim-Kosta M,Leonnet C,Arnoux I,Loosveld M

    更新日期:2020-12-01 00:00:00

  • Live remote digital microscopy in peripheral blood smear evaluation: Intraobserver concordance and experience.

    abstract:INTRODUCTION:Peripheral blood smear (PBS) review is a routine laboratory test which requires pathologist's interpretation when abnormal indices, atypical cells, or critical findings are identified. Real-time remote digital microscopy (DM) can potentially facilitate rapid review when an on-site pathologist is not availa...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12914

    authors: Haninger DM,Nassiri M,Settembre ED,Zhang S,Zhou J

    更新日期:2018-12-01 00:00:00