Flow cytometry in the diagnosis of mature B-cell lymphoproliferative disorders.

Abstract:

:B-lineage lymphoproliferative disorders (LPD) are rather frequent diseases, associated with specific clinical or biological features but also sometimes of fortuitous discovery. Multiparameter flow cytometry plays a major role for a rapid diagnostic indication, on peripheral blood or bone marrow samples in most instances, guiding complementary analyses and allowing for the proper therapeutic management of patients. After describing the important pre-analytical precautions required for an adequate assessment, the immunophenotypic features of small-cell and large-cell lymphomas are described in this review. The ubiquitous expression of CD19 is a first mandatory gating step. A possible clonal proliferation is then suspected by the demonstration of surface immunoglobulin light chain restriction. The aberrant presence of CD5 allows to segregate chronic lymphocytic leukemia and mantle cell lymphoma in most cases. Other LPD exhibit specific immunophenotypic features. A table of useful markers and a decision tree are provided. Of note, immunophenotypic data should as much as possible be interpreted in an integrated manner, involving the patient's clinical and other biological features, and be completed by further chromosomal and/or molecular investigations.

journal_name

Int J Lab Hematol

authors

Debord C,Wuillème S,Eveillard M,Theisen O,Godon C,Le Bris Y,Béné MC

doi

10.1111/ijlh.13170

subject

Has Abstract

pub_date

2020-06-01 00:00:00

pages

113-120

eissn

1751-5521

issn

1751-553X

journal_volume

42 Suppl 1

pub_type

杂志文章,评审
  • Association of mean platelet volume and platelet count with the development and prognosis of ischemic and hemorrhagic stroke.

    abstract:INTRODUCTION:Mean platelet volume (MPV) and platelet (PLT) count are the two major parameters that reflect the functions and activities of PLTs. The associations of MPV and PLT count with the occurrence and prognosis of stroke have not been fully clarified. This study aimed to investigate the association of MPV and PLT...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章

    doi:10.1111/ijlh.12474

    authors: Du J,Wang Q,He B,Liu P,Chen JY,Quan H,Ma X

    更新日期:2016-06-01 00:00:00

  • The impact of long-haul air travel on variables of the athlete's biological passport.

    abstract:INTRODUCTION:Dehydration, fluid shifts or changes in coagulation occurring during air travel can trigger distinct reactions in the haematological system. Athletes are concerned that these effects might impair sporting performance, increase the risk of thrombosis or cause abnormalities in blood values that might be mist...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01450.x

    authors: Schumacher YO,Klodt F,Nonis D,Pottgiesser T,Alsayrafi M,Bourdon PC,Voss SC

    更新日期:2012-12-01 00:00:00

  • Morphologic identification of atypical chronic lymphocytic leukemia by digital microscopy.

    abstract:INTRODUCTION:Atypical chronic lymphocytic leukemia (aCLL) is a morphologic variant found in approximately 25% of patients with chronic lymphocytic leukemia (CLL). Although aCLL has a more aggressive course compared to typical CLL (tCLL), it is not usually reported. This retrospective study used digital microscopy to mo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12167

    authors: Marionneaux S,Maslak P,Keohane EM

    更新日期:2014-08-01 00:00:00

  • The importance of β globin deletion analysis in the evaluation of patients with β thalassemia.

    abstract:INTRODUCTION:Beta globin deletion/duplication analysis may serve as a useful adjunct to sequence analysis. Our purpose was to develop a robust assay for beta globin deletion/duplication analysis and determine its role in evaluating patients with beta thalassemia. METHODS:A single tube semi-quantitative fluorescent PCR...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01287.x

    authors: Mikula M,Buller-Burckle A,Gallivan M,Sun W,Franklin CR,Strom CM

    更新日期:2011-06-01 00:00:00

  • Case report of HbC/beta(0)-thalassemia from India.

    abstract::This 22-year-old women presented to the ante-natal clinic of this hospital for prenatal screening for beta-thalassemia. Cation exchange high performance liquid chromatography (HPLC) using 'Beta Thalassemia Short Program' on Bio-Rad 'Variant' system revealed HbC value of 81.6%. The CBC showed microcytic hypochromic ane...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1365-2257.2006.00850.x

    authors: Kumar S,Rana M,Handoo A,Saxena R,Verma IC,Bhargava M,Sood SK

    更新日期:2007-10-01 00:00:00

  • ICSH recommendations for the measurement of haemoglobin F.

    abstract::Measurement of the Haemoglobin F in red cell haemolysates is important in the diagnosis of δβ thalassaemia, hereditary persistence of fetal haemoglobin (HPFH) and in the diagnosis and management of sickle cell disease. The distribution of Hb F in red cells is useful in the diagnosis of HPFH and in the assessment of fe...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,实务指引

    doi:10.1111/j.1751-553X.2011.01367.x

    authors: Stephens AD,Angastiniotis M,Baysal E,Chan V,Davis B,Fucharoen S,Giordano PC,Hoyer JD,Mosca A,Wild B,International Council for The Standardisation of Haematology (ICSH).

    更新日期:2012-02-01 00:00:00

  • Entonox as a sedative for bone marrow aspiration and biopsy.

    abstract::Bone marrow aspiration and biopsy can be a painful procedure. Sedation techniques may make this investigation more acceptable to patients, but have the potential to cause life-threatening complications, as well as requiring additional staff and equipment for safe administration. We assessed the use of Entonox, a 50 : ...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章

    doi:10.1111/j.1751-553X.2007.00905.x

    authors: Gudgin EJ,Besser MW,Craig JI

    更新日期:2008-02-01 00:00:00

  • Abrogation of red blood cell G6PD enzyme activity through Heat treatment: development of survey material for the UK NEQAS G6PD scheme.

    abstract:INTRODUCTION:Participation in external quality assessment (EQA) is central to the maintenance of high-quality laboratory results in patient diagnosis and clinical trials. Laboratories in the TAF112582 DETECTIVE study (ClinicalTrials.gov identifier: NCT01376167) are enrolled in the United Kingdom National Quality Assess...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/ijlh.12627

    authors: Roper DR,De la Salle B,Soni V,Fletcher K,Green JA

    更新日期:2017-06-01 00:00:00

  • How I investigate for bleeding disorders.

    abstract:INTRODUCTION:Laboratory investigations for bleeding disorders are warranted when an individual has a personal and/or family history of bleeding, and/or laboratory findings that suggest the possibility of an inherited or acquired bleeding disorder. METHODS:This review summarizes author's experience with ordering and re...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12822

    authors: Hayward CPM

    更新日期:2018-05-01 00:00:00

  • Upregulation of long noncoding RNA Lnc-IRF2-3 and Lnc-ZNF667-AS1 is associated with poor survival in B-chronic lymphocytic leukemia.

    abstract:BACKGROUND:Lnc-IRF2-3 and Lnc-ZNF667-AS1 were recently studied as a positive biomarker for many tumor cells. However, experimental studies found that they are associated with worse outcomes in B-CLL. METHODS:A prospective case study was conducted on 135 B-CLL patients that were compared to thirty healthy controls. The...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13167

    authors: El-Khazragy N,Esmaiel MA,Mohamed MM,Hassan NS

    更新日期:2020-06-01 00:00:00

  • ADAMTS13 activity to von Willebrand factor antigen ratio predicts acute kidney injury in patients with COVID-19: Evidence of SARS-CoV-2 induced secondary thrombotic microangiopathy.

    abstract:INTRODUCTION:Severe COVID-19 is often compounded by a prothrombotic state that is associated with poor outcomes. In this investigation, we aimed to evaluate ADAMTS13 activity, von Willebrand factor level (VWF:Ag), and the corresponding ADAMTS13 activity/VWF:Ag ratio, in patients with COVID-19 and for associations with ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13415

    authors: Henry BM,Benoit SW,de Oliveira MHS,Lippi G,Favaloro EJ,Benoit JL

    更新日期:2020-12-03 00:00:00

  • Optimal wavelength for the clot waveform analysis: Determination of the best resolution with minimal interference of the reagents.

    abstract:INTRODUCTION:Clot waveform analysis (CWA), a new methodology to assess coagulation process, can be usefully applied in various clinical settings. However, its clinical use is limited mainly because of the absence of standardization. No consensus exists regarding the wavelengths at which CWA has to be performed what is ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12975

    authors: Evrard J,Siriez R,Morimont L,Thémans P,Laloy J,Bouvy C,Gheldof D,Mullier F,Dogné JM,Douxfils J

    更新日期:2019-06-01 00:00:00

  • A level-headed approach to measuring direct oral anticoagulants: A 2-year retrospective analysis of DOAC levels from a tertiary UK centre.

    abstract:INTRODUCTION:Direct oral anticoagulants (DOAC) are commonly prescribed and measuring drug levels may be useful in a number of contexts. However, data on DOAC level measurement and their clinical utility in real-world studies are limited. METHODS:We carried out a 2-year retrospective cohort study of DOAC levels measure...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12944

    authors: Denny NDR,Keighley L,Siganporia Z,Thachil J,Nash MJ

    更新日期:2019-04-01 00:00:00

  • Assessing maternal clotting function with novel global coagulation assays: A prospective pilot study.

    abstract:INTRODUCTION:Women are at higher risk of venous thromboembolism (VTE) during pregnancy and the puerperium. Global coagulation assays (GCAs), including thromboelastography (TEG), thrombin generation using the calibrated automated thrombogram (CAT) and fibrin generation using the overall haemostatic potential assay (OHP)...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13389

    authors: O'Keefe D,Lim HY,Tham J,Ho P,Hui L

    更新日期:2020-11-10 00:00:00

  • Different kinetic patterns of BCR-ABL transcript levels in imatinib-treated chronic myeloid leukemia patients after achieving complete cytogenetic response.

    abstract::Bone marrow BCR-ABL transcript levels were monitored serially by real-time quantitative PCR in 46 imatinib-treated chronic myeloid leukemia patients after achieving complete cytogenetic response (CCyR) for a median of 42 months (range: 9-53). Of 41 patients in continuous CCyR, 32 and nine could achieve a >/=3-log (MMo...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.00962.x

    authors: Qin YZ,Liu YR,Zhu HH,Li JL,Ruan GR,Zhang Y,Jiang Q,Jiang H,Li LD,Chang Y,Huang XJ,Chen SS

    更新日期:2008-08-01 00:00:00

  • The presence of leukaemia-associated phenotypes is an independent predictor of induction failure in acute myeloid leukaemia.

    abstract::Immunophenotyping of acute myeloid leukaemia (AML) has controversial implications with regards to prognosis. The aims of the present study were to determine the frequency of leukaemia-associated phenotypes (LAP) in AML and to correlate their presence with response to induction chemotherapy. We analysed bone marrow sam...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2007.01003.x

    authors: Al-Mawali A,To LB,Gillis D,Hissaria P,Mundy J,Lewis I

    更新日期:2009-02-01 00:00:00

  • 2016 WHO Classification update-What's new in lymphoid neoplasms.

    abstract::In the 8 years since the publication of the 4th edition of the WHO Classification of Hematopoietic and Lymphoid Tumours in 2008, there has been rapid accumulation of knowledge in the molecular genetics, biology, clinical behavior of many hematologic malignancies. Concepts and models have advanced to the point at which...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.12650

    authors: Hsi ED

    更新日期:2017-05-01 00:00:00

  • Gene expression risk signatures maintain prognostic power in multiple myeloma despite microarray probe set translation.

    abstract:INTRODUCTION:Gene expression profiling (GEP) risk models in multiple myeloma are based on 3'-end microarrays. We hypothesized that GEP risk signatures could retain prognostic power despite being translated and applied to whole-transcript microarray data. METHODS:We studied CD138-positive bone marrow plasma cells in a ...

    journal_title:International journal of laboratory hematology

    pub_type: 临床试验,杂志文章,多中心研究

    doi:10.1111/ijlh.12486

    authors: Hermansen NE,Borup R,Andersen MK,Vangsted AJ,Clausen NT,Kristensen DL,Nielsen FC,Gimsing P

    更新日期:2016-06-01 00:00:00

  • Live remote digital microscopy in peripheral blood smear evaluation: Intraobserver concordance and experience.

    abstract:INTRODUCTION:Peripheral blood smear (PBS) review is a routine laboratory test which requires pathologist's interpretation when abnormal indices, atypical cells, or critical findings are identified. Real-time remote digital microscopy (DM) can potentially facilitate rapid review when an on-site pathologist is not availa...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12914

    authors: Haninger DM,Nassiri M,Settembre ED,Zhang S,Zhou J

    更新日期:2018-12-01 00:00:00

  • The automation of routine light transmission platelet aggregation.

    abstract:INTRODUCTION:The investigation of platelet function by aggregometry requires specialist equipment and is labour intensive. We have developed an automated platelet aggregation method on a routine coagulation analyser. METHODS:We used a CS-2000i (Sysmex) with prototype software to perform aggregation in platelet-rich pl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12161

    authors: Lawrie AS,Kobayashi K,Lane PJ,Mackie IJ,Machin SJ

    更新日期:2014-08-01 00:00:00

  • Diagnostic and prognostic utility of WBC counts and cell population data in patients with COVID-19.

    abstract:INTRODUCTION:Early diagnosis and identification of potential critical cases for timely treatment are crucial for COVID-19 patients. The aim of this study was to analyze the diagnostic and prognostic implications of WBC and cell population data (CPD) abnormalities related to COVID-19 at disease onset. METHODS:Baseline ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13395

    authors: Naoum FA,Ruiz ALZ,Martin FHO,Brito THG,Hassem V,Oliveira MGL

    更新日期:2020-11-15 00:00:00

  • Molecular diagnosis of thrombocytopenia-absent radius syndrome using next-generation sequencing.

    abstract:INTRODUCTION:Thrombocytopenia-absent radius (TAR) syndrome is a rare autosomal recessive disease. Patients are compound heterozygotes for a loss-of-function allele, which in most cases is a large genomic deletion on chromosome 1q21.1 containing the RBM8A gene, and a noncoding variant located in the 5'UTR (rs139428292) ...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12516

    authors: Nicchia E,Giordano P,Greco C,De Rocco D,Savoia A

    更新日期:2016-08-01 00:00:00

  • Evaluation of an automated algorithm for interpretation of lupus anticoagulant testing.

    abstract:INTRODUCTION:Lupus anticoagulant (LAC) testing is a multistep procedure including screening, mixing, and confirmation tests. STA Coag Expert is a software module for STA R Max and STA Compact Max analyzers which includes an on-demand LAC algorithm, based on ISTH guidelines, for automatic interpretation, calculation, an...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13001

    authors: Florin L,Desloovere M,Devreese KMJ

    更新日期:2019-06-01 00:00:00

  • Paediatric reference intervals for common coagulation assays in Chinese children as performed on the STA-R coagulation analyzer.

    abstract:INTRODUCTION:In order to correctly manage the paediatric patients affected with haemostatic disorders, age-appropriate reference intervals should be used. The purpose of this study was to establish age-specific reference intervals for prothrombin time (PT), thrombin time (TT), activated partial thromboplastin time (aPT...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13098

    authors: Liu J,Dai Y,Yuan E,Li Y,Wang Q,Wang L,Su Y

    更新日期:2019-10-01 00:00:00

  • Limitation of the activated partial thromboplastin time as a monitoring method of the direct thrombin inhibitor argatroban.

    abstract:BACKGROUND:Argatroban is licensed for patients with heparin-induced thrombocytopenia and monitoring is conventionally by activated partial thromboplastin time (APTT) ratio with a target of 1.5-3.0 and not exceeding 100 s. The APTT may be influenced by coagulopathies, lupus anticoagulant and raised FVIII levels. Variabl...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12414

    authors: Guy S,Kitchen S,Maclean R,Van Veen JJ

    更新日期:2015-12-01 00:00:00

  • International Council for Standardization in Haematology (ICSH) laboratory guidance for the evaluation of haemostasis analyser-reagent test systems. Part 1: Instrument-specific issues and commonly used coagulation screening tests.

    abstract::Before a new method is used for clinical testing, it is essential that it is evaluated for suitability for its intended purpose. This document gives guidance for the performance of verification, validation and implementation processes required by regulatory and accreditation bodies. It covers the planning and executio...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章,评审

    doi:10.1111/ijlh.13411

    authors: Gardiner C,Coleman R,de Maat MPM,Dorgalaleh A,Echenagucia M,Gosselin RC,Ieko M,Kitchen S

    更新日期:2020-11-29 00:00:00

  • Expression analysis of BECN1 in acute myeloid leukemia: association with distinct cytogenetic and molecular abnormalities.

    abstract:INTRODUCTION:In acute myeloid leukemia (AML), it has been shown that AML-derived cells often remain sensitive to autophagy-inducing stimuli, leading to the idea that harnessing the autophagy can be pertinent to AML cytotoxic therapy. Despite this promising notion, to date, there is no comprehensive study addressing aut...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.12454

    authors: Zare-Abdollahi D,Safari S,Movafagh A,Ghadiani M,Tabarraee M,Riazi-Isfahani S,Gorji S,Keyvan L,Gachkar L

    更新日期:2016-04-01 00:00:00

  • Analysis of polymorphisms of TNF-α, LT-α, IL-10, IL-12 and CTLA-4 in patients with warm autoimmune haemolytic anaemia.

    abstract:INTRODUCTION:Autoimmune haemolytic anaemia (AIHA) is defined as the increased destruction of red blood cells (RBCs) in the presence of anti-RBC autoantibodies and/or complement. Its pathogenesis is multifactorial and includes changes in mechanisms of cytokine production and functionality. A number of recent studies hav...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2012.01400.x

    authors: D'Abronzo LS,Barros MM,Bordin JO,Figueiredo MS

    更新日期:2012-08-01 00:00:00

  • The role of automated measurement of red cell subpopulations on the Sysmex XE 5000 analyzer in the differential diagnosis of microcytic anemia.

    abstract::Cell counter-based formulae have been used in the differential diagnosis of microcytic anemia. The measurement of new red cell parameters is now available on the Sysmex XE 5000 analyzer. Derived from the percentages of microcytic and hypochromic red cells, the authors describe the new formula %microcytic-%hypochromic,...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/j.1751-553X.2010.01237.x

    authors: Urrechaga E,Borque L,Escanero JF

    更新日期:2011-02-01 00:00:00

  • The applicability of multiparameter flow cytometry for the detection of minimal residual disease using different-from-normal panels to predict relapse in patients with acute myeloid leukemia after allogeneic transplantation.

    abstract:BACKGROUND:The MRD status detected using multiparameter flow cytometry (MFC) before allogeneic hematopoietic stem cell transplantation (allo-HSCT) has crucial prognostic value for patients with acute myeloid leukemia (AML) in morphologic complete remission (CR). We designed a novel panel of antibodies to identify aberr...

    journal_title:International journal of laboratory hematology

    pub_type: 杂志文章

    doi:10.1111/ijlh.13070

    authors: Wang Z,Guo M,Zhang Y,Xu S,Cheng H,Wu J,Zhang W,Hu X,Yang J,Wang J,Tang G

    更新日期:2019-10-01 00:00:00