Bioactive Ti + Mg composites fabricated by powder metallurgy: The relation between the microstructure and mechanical properties.

Abstract:

:Metallic implant materials are biomaterials that have experienced major development over the last fifty years, yet some demands posed to them have not been addressed. For the osseointegration process and the outcome of endosseous implantation, it is crucial to reduce the stress shielding effect and achieve sufficient biocompatibility. Powder metallurgy (PM) was utilized in this study to fabricate a new type of titanium (Ti) + magnesium (Mg) bioactive composite to enable stress-shielding reduction and obtain better biocompatibility compared with that of the traditional Ti and Ti alloys used for dental implants. Such composites are produced by well-known cost-effective and widely used PM methods, which eliminate the need for complex and costly Ti casting used in traditional implant production. The relation between the microstructure and mechanical properties of as-extruded Ti + (0-24) vol% Mg composites was investigated with respect to the Mg content. The microstructure of the composites consisted of a biodegradable Mg component in the form of filaments, elongated along the direction of extrusion, which were embedded within a permanent, bioinert Ti matrix. As the Mg content was increased, the discrete filaments became interconnected with each other and formed a continuous Mg network. Young's modulus (E) of the composites was reduced to 81 GPa, while other tensile mechanical properties were maintained at the values required for a dental implant material. The corrosion behavior of the Ti + Mg composites was studied during immersion in a Hank's balanced salt solution (HBSS) for up to 21 days. The elution of Mg pores formed at former Mg sites led to a further decrease of E to 74 GPa. The studied compositions showed that a new Ti + Mg metallic composite should be promising for load-bearing applications in endosseous dental implants in the future.

authors

Balog M,Ibrahim AMH,Krizik P,Bajana O,Klimova A,Catic A,Schauperl Z

doi

10.1016/j.jmbbm.2018.10.008

subject

Has Abstract

pub_date

2019-02-01 00:00:00

pages

45-53

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(18)31171-8

journal_volume

90

pub_type

杂志文章
  • Mechanical properties and electrochemical behavior of porous Ti-Nb biomaterials.

    abstract::Ti-Nb-based alloys - with their superior mechanical properties and biocompatibility - are attractive biomaterials for orthopedic implants. By producing this alloys with a porous structure, it is possible to achieve mechanical properties similar to that of bone and to facilitate cellular activities. In this study, Ti16...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.018

    authors: Yılmaz E,Gökçe A,Findik F,Gulsoy HO,İyibilgin O

    更新日期:2018-11-01 00:00:00

  • Surface integrity and corrosion performance of biomedical magnesium-calcium alloy processed by hybrid dry cutting-finish burnishing.

    abstract::Biodegradable magnesium-calcium (MgCa) alloy is a very attractive orthopedic biomaterial compared to permanent metallic alloys. However, the critical issue is that MgCa alloy corrodes too fast in the human organism. Compared to dry cutting, the synergistic dry cutting-finish burnishing can significantly improve corros...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.026

    authors: Salahshoor M,Li C,Liu ZY,Fang XY,Guo YB

    更新日期:2018-02-01 00:00:00

  • Mechanical response of human abdominal walls ex vivo: Effect of an incisional hernia and a mesh repair.

    abstract::The design of meshes for the treatment of incisional hernias could benefit from better knowledge of the mechanical response of the abdominal wall and how this response is affected by the implant. The aim of this study was to characterise the mechanical behaviour of the human abdominal wall. Abdominal walls were tested...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.002

    authors: Podwojewski F,Otténio M,Beillas P,Guérin G,Turquier F,Mitton D

    更新日期:2014-10-01 00:00:00

  • On the tension-compression switch hypothesis in arterial mechanics.

    abstract::The tension-compression switch hypothesis for soft tissue proposes that when collagen fibres are compressed they do not contribute to the mechanical response which is then assumed to be the isotropic response of the extra-cellular matrix in which they are embedded. Such an assumption would seem reasonable. However, th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103558

    authors: Horgan CO,Murphy JG

    更新日期:2020-03-01 00:00:00

  • A constitutive law for degrading bioresorbable polymers.

    abstract::This paper presents a constitutive law that predicts the changes in elastic moduli, Poisson's ratio and ultimate tensile strength of bioresorbable polymers due to biodegradation. During biodegradation, long polymer chains are cleaved by hydrolysis reaction. For semi-crystalline polymers, the chain scissions also lead ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.02.026

    authors: Samami H,Pan J

    更新日期:2016-06-01 00:00:00

  • Prediction of cross section fracture path of cortical bone through nanoindentation array.

    abstract::Although great progresses in the fracture mechanisms and deformation behaviors of cortical bones have been achieved, the effective methods to predict the surface fracture path of cortical bones are still difficult. By using depth-sensing nanoindentation measurement technique, the hardness distribution map of cortical ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104303

    authors: Ma Z,Qiang Z,Zeng K,Xiao J,Zhou L,Zu L,Zhao H,Ren L

    更新日期:2021-01-20 00:00:00

  • Monotonic and cyclic loading behavior of porous scaffolds made from poly(para-phenylene) for orthopedic applications.

    abstract::Porous poly(para-phenylene) (PPP) scaffolds have tremendous potential as an orthopedic biomaterial; however, the underlying mechanisms controlling the monotonic and cyclic behavior are poorly understood. The purpose of this study was to develop a method to integrate micro-computed tomography (μCT), finite-element anal...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.10.004

    authors: Hoyt AJ,Yakacki CM,Fertig RS 3rd,Dana Carpenter R,Frick CP

    更新日期:2015-01-01 00:00:00

  • Influence of cold rolling and ageing treatment on microstructure and mechanical properties of Ti-30Nb-5Ta-6Zr alloy.

    abstract::In this study, the relationship between deformation mechanism and rolling reductions was investigated, and the effects of deformation reductions on the microstructure and mechanical properties of the alloys both cold rolled and aged were revealed. It was found that the equiaxed β grains of the Ti-30Nb-5Ta-6Zr alloy ha...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.06.006

    authors: Wang Y,Zhao J,Dai S,Chen F,Yu X,Zhang Y

    更新日期:2013-11-01 00:00:00

  • Integrated experimental and theoretical approach for corrosion and wear evaluation of laser surface nitrided, Ti-6Al-4V biomaterial in physiological solution.

    abstract::A laser based surface nitriding process was adopted to further enhance the osseo-integration, corrosion resistance, and tribological properties of the commonly used bioimplant alloy, Ti-6Al-4V. Earlier preliminary osteoblast, electrochemical, and corrosive wear studies of laser nitrided titanium in simulated body flui...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.05.017

    authors: Vora HD,Shanker Rajamure R,Dahotre SN,Ho YH,Banerjee R,Dahotre NB

    更新日期:2014-09-01 00:00:00

  • Mechanical characterization of bio composite films as a novel drug carrier platform for sustained release of 5-fluorouracil for colon cancer: Methodological investigation.

    abstract::In this study, we employed Pectin (PC) as a matrix that is hybridized with three different nucleobase (NB) units (cytosine, thymine, uracil) to generate pectin-nucleobase(PC-NB) biocomposite films stabilized through bio-multiple hydrogen bonds (BMHBs) as drug carrier for anticancer 5-Fluorouracil (5-FU). Prepared bioc...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104266

    authors: Tamilselvi S,Kavitha R,Usharani M,Mumjitha M,Mohanapriya S,MohanaPriya S

    更新日期:2021-03-01 00:00:00

  • Hybrid micro/nanostructural surface offering improved stress distribution and enhanced osseointegration properties of the biomedical titanium implant.

    abstract:OBJECTIVES:The aim of the present study was to investigate the surface characteristic, biomechanical behavior, hemocompatibility, bone tissue response and osseointegration of the optimal micro-arc oxidation surface-treated titanium (MST-Ti) dental implant. MATERIALS AND METHODS:The surface characteristic, biomechanica...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.042

    authors: Hou PJ,Ou KL,Wang CC,Huang CF,Ruslin M,Sugiatno E,Yang TS,Chou HH

    更新日期:2018-03-01 00:00:00

  • A method for investigating the cellular response to cyclic tension or compression in three-dimensional culture.

    abstract::We have an interest in the cellular response to mechanical stimuli, and here describe an in-vitro method to examine the response of cells cultured in a three-dimensional matrix to mechanical compressive and tensile stress. Synthetic aliphatic polyester scaffolds coated with 45S5 bioactive glass were seeded with human ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.08.006

    authors: Sarrafpour B,Boughton P,Farahani RM,Cox SC,Denyer G,Kelly E,Zoellner H

    更新日期:2018-12-01 00:00:00

  • Bite force mechanics and allometry of piranha (Serrasalmidae).

    abstract::The bite force of the piranha (Serrasalmidae) has drawn considerable attention due to its ability to effectively capture and masticate prey. Herein, we analyze theoretical anterior bite forces using a lever approach and compare them to in-vivo maximum bite forces. We provide a mechanics analysis that explains the scal...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104296

    authors: Velasco-Hogan A,Meyers MA

    更新日期:2021-03-01 00:00:00

  • Designing vascular supportive albumen-rich composite bioink for organ 3D printing.

    abstract::Bioink plays a major role in 3D printing of tissues and organs. Alginate is a widely used component for bioinks but its cellular responses are limited, which limits its clinical translation. In this study, we demonstrate the printability and cellular compatibility of composite bioink consists of sodium alginate (NaAlg...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103642

    authors: Liu S,Zhang H,Hu Q,Shen Z,Rana D,Ramalingam M

    更新日期:2020-04-01 00:00:00

  • The effect of equiaxial stretching on the osteogenic differentiation and mechanical properties of human adipose stem cells.

    abstract::Although mechanical cues are known to affect stem cell fate and mechanobiology, the significance of such stimuli on the osteogenic differentiation of human adipose stem cells (hASCs) remains unclear. In this study, we investigated the effect of long-term mechanical stimulation on the attachment, osteogenic differentia...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.04.016

    authors: Virjula S,Zhao F,Leivo J,Vanhatupa S,Kreutzer J,Vaughan TJ,Honkala AM,Viehrig M,Mullen CA,Kallio P,McNamara LM,Miettinen S

    更新日期:2017-08-01 00:00:00

  • Biocompatibility evaluation of a thermoplastic rubber for wireless telemetric intracranial pressure sensor coating.

    abstract::This study investigated the biocompatibility of the experimental thermoplastic rubber Arbomatrix(™) that will be used as the protective coating on a novel intracranial pressure (ICP) sensor silicon chip. Arbomatrix(™) was benchmarked against biocompatible commercial silicone rubber shunt tubing in the brain via a rat ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.01.018

    authors: Yang J,Charif AC,Puskas JE,Phillips H,Shanahan KJ,Garsed J,Fleischman A,Goldman K,Roy S,Luebbers MT,Dombrowski SM,Luciano MG

    更新日期:2015-05-01 00:00:00

  • Within subject heterogeneity in tissue-level post-yield mechanical and material properties in human trabecular bone.

    abstract::The ability to determine patient-specific mechanical properties of trabecular bone is needed for a reliable estimation of fracture risks. Tissue mechanics and material composition are important factors that contribute to trabecular bone performance, but only a few studies have investigated the post-yield behaviour of ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.04.014

    authors: Carretta R,Stüssi E,Müller R,Lorenzetti S

    更新日期:2013-08-01 00:00:00

  • An adaptive finite element simulation of fretting wear damage at the head-neck taper junction of total hip replacement: The role of taper angle mismatch.

    abstract::An adaptive finite element simulation was developed to predict fretting wear in a head-neck taper junction of hip joint implant through a two dimensional (2D) model and based on the Archard wear equation. This model represents the most critical section of the head-neck junction which was identified from a 3D model of ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.003

    authors: Fallahnezhad K,Oskouei RH,Badnava H,Taylor M

    更新日期:2017-11-01 00:00:00

  • Improved tribocorrosion performance of bio-functionalized TiO2 nanotubes under two-cycle sliding actions in artificial saliva.

    abstract::After insertion into bone, dental implants may be subjected to tribocorrosive conditions resulting in the release of metallic ions and solid wear debris, which can induce to peri-implant inflammatory reactions accompanied by bone loss, and ultimately implant loosening. Despite the promising ability of TiO2 nanotubes (...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.01.038

    authors: Alves SA,Rossi AL,Ribeiro AR,Toptan F,Pinto AM,Shokuhfar T,Celis JP,Rocha LA

    更新日期:2018-04-01 00:00:00

  • Simulations of skin and subcutaneous tissue loading in the buttocks while regaining weight-bearing after a push-up in wheelchair users.

    abstract::Pressure ulcers (PUs) are common in patients who chronically depend on a wheelchair for mobility, such as those with a spinal cord injury (SCI). In attempt to prevent the formation of PUs, pressure relieving maneuvers, such as push-ups, are commonly recommended for individuals with SCI. However, very little is known a...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.04.015

    authors: Levy A,Kopplin K,Gefen A

    更新日期:2013-12-01 00:00:00

  • Wear characteristics of WSU total ankle replacement devices under shear and torsion loads.

    abstract:BACKGROUND:There are several factors that contribute to the failure of total ankle replacement (TAR). Aseptic loosening is one of the primary mechanisms of failure in TAR. Since a cross-linked ultrahigh molecular weight polyethylene (UHMWPE) is used as liner material, there is a need to quantify and develop methods to ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.12.010

    authors: Gundapaneni D,Tsatalis JT,Laughlin RT,Goswami T

    更新日期:2015-04-01 00:00:00

  • A method to develop mock arteries suitable for cell seeding and in-vitro cell culture experiments.

    abstract::Sylgard((R)) is a biocompatible elastomer which has been widely used in biomedical applications including in simulations of the mechanical response of soft tissues and mechanotransduction investigations. In this study the effect of fabrication parameters including base to curing agent ratio and curing time on the mech...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2010.04.003

    authors: Colombo A,Zahedmanesh H,Toner DM,Cahill PA,Lally C

    更新日期:2010-08-01 00:00:00

  • Understanding hydration effects on mechanical and impacting properties of turtle shell.

    abstract::Study of the properties of natural biomaterials provides a reliable experimental basis for the design of biomimetic materials. The mechanical properties and impact wear behaviors of turtle shell with different soaking time were investigated on a micro-amplitude impact wear tester. The damage behavior of turtle shells ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.007

    authors: Zhang X,Cai ZB,Li W,Zhu MH

    更新日期:2018-02-01 00:00:00

  • Modeling failure of soft anisotropic materials with application to arteries.

    abstract::The arterial wall is a composite where the preferred orientation of collagen fibers induces anisotropy. Though the hyperelastic theories of fiber-reinforced composites reached a high level of sophistication and showed a reasonable correspondence with the available experimental data they are short of the failure descri...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.01.002

    authors: Volokh KY

    更新日期:2011-11-01 00:00:00

  • The effect of aging on the mechanical behaviour of cuticle in the locust Schistocerca gregaria.

    abstract::Despite some previous work on the morphology and mechanical properties of parts of the insect exoskeleton, there is very little known about how these properties change over time during the life of the insect. We examined the hind tibia of the adult desert locust (Schistocerca gregaria) as a function of time up to 63 d...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.02.008

    authors: Parle E,Taylor D

    更新日期:2017-04-01 00:00:00

  • Tissue mechanics of piled critical size biomimetic and biominerizable nanocomposites: Formation of bioreactor-induced stem cell gradients under perfusion and compression.

    abstract:BACKGROUND:Perfusion bioreactors are used to solve problems in critical size bone tissue engineering. Biominerizable and biocompatible nanocomposites are suitable scaffold materials for this purpose because they offer mineral components in organic carriers. Human adipose derived stem cells (ASCs) can potentially be use...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.022

    authors: Baumgartner W,Welti M,Hild N,Hess SC,Stark WJ,Bürgisser GM,Giovanoli P,Buschmann J

    更新日期:2015-07-01 00:00:00

  • Effects of homogenization technique and introduction of interfaces in a multiscale approach to predict the elastic properties of arthropod cuticle.

    abstract::In this paper the mechanical response of the arthropod cuticle is evaluated by means of a multiscale approach including interface effects. The cuticle's elastic behavior is modeled at the nano and the micro scales by mean-field homogenization techniques. With respect to the work of Nikolov et al. (2011), the idea has ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.04.003

    authors: Lhadi S,Ahzi S,Rémond Y,Nikolov S,Fabritius H

    更新日期:2013-07-01 00:00:00

  • Effects of fibrin sealant and bone fragments on defect regeneration performed on rat tibiae: An experimental study.

    abstract::Fibrin sealant (FS) is a biomaterial that exhibits hemostatic and repairing properties. It has been successfully used as scaffolds and adhesives to improve repair and regeneration of tissues. The objective of this study was to evaluate the effect of FS in the regeneration process of bone defects in male rat tibias thr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103662

    authors: de Oliveira CTB,Leonel BC,de Oliveira AC,de Brito Paiva M,Ramos J,Barraviera B,Ferreira Junior RS,Shimano AC

    更新日期:2020-04-01 00:00:00

  • Stem cell therapy restores viscoelastic properties of myocardium in rat model of hypertension.

    abstract::Extensive remodeling of the myocardium is seen in a variety of cardiovascular diseases, including systemic hypertension. Stem cell therapy has been proposed to improve the clinical outcomes of hypertension, and we hypothesized that changes in mechanical properties of the myocardium would accompany the progression of d...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.11.041

    authors: Rubiano A,Qi Y,Guzzo D,Rathinasabapathy A,Rowe K,Pepine C,Simmons C

    更新日期:2016-06-01 00:00:00

  • Combination of a biodegradable three-dimensional (3D) - printed cage for mechanical support and nanofibrous membranes for sustainable release of antimicrobial agents for treating the femoral metaphyseal comminuted fracture.

    abstract::The aim of this study was to develop a biodegradable three-dimensional-printed polylactide (PLA) cage for promoting bony fixation and an antibiotics-embedded poly(d,l)-lactide-co-glycolide (PLGA) nanofibrous membrane for infectious prophylaxis during treating the comminuted metaphyseal fracture in a rabbit femoral mod...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.05.002

    authors: Chou YC,Lee D,Chang TM,Hsu YH,Yu YH,Chan EC,Liu SJ

    更新日期:2017-08-01 00:00:00