Designing vascular supportive albumen-rich composite bioink for organ 3D printing.

Abstract:

:Bioink plays a major role in 3D printing of tissues and organs. Alginate is a widely used component for bioinks but its cellular responses are limited, which limits its clinical translation. In this study, we demonstrate the printability and cellular compatibility of composite bioink consists of sodium alginate (NaAlg) and egg white, also called albumen. The experimental conditions necessary for 3D printing composite bioink were optimized by changing different concentration ratios of Albumen/NaAlg and their various physicochemical properties were studied. The structural characteristics of the 3D printed scaffold was also investigated. In vitro experiments showed that human umbilical vein endothelial cells can successfully attach to the printed scaffold and maintain high viability during the course of study. Interestingly, vascular sprouting and neovascular network formation was observed inbetween fibers within the printed scaffold. In conclusion, the results of this study demonstrate that 3D printed Albumen/NaAlg composite bioinks with favorable biological functionality hold a great potential in tissue and organ engineering.

authors

Liu S,Zhang H,Hu Q,Shen Z,Rana D,Ramalingam M

doi

10.1016/j.jmbbm.2020.103642

subject

Has Abstract

pub_date

2020-04-01 00:00:00

pages

103642

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(19)31362-1

journal_volume

104

pub_type

杂志文章
  • Prediction of cross section fracture path of cortical bone through nanoindentation array.

    abstract::Although great progresses in the fracture mechanisms and deformation behaviors of cortical bones have been achieved, the effective methods to predict the surface fracture path of cortical bones are still difficult. By using depth-sensing nanoindentation measurement technique, the hardness distribution map of cortical ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104303

    authors: Ma Z,Qiang Z,Zeng K,Xiao J,Zhou L,Zu L,Zhao H,Ren L

    更新日期:2021-01-20 00:00:00

  • On the mechanical characterization and modeling of polymer gel brain substitute under dynamic rotational loading.

    abstract::The use of highly sensitive soft materials has become increasingly apparent in the last few years in numerous industrial fields, due to their viscous and damping nature. Unfortunately these materials remain difficult to characterize using conventional techniques, mainly because of the very low internal forces supporte...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.06.008

    authors: Fontenier B,Hault-Dubrulle A,Drazetic P,Fontaine C,Naceur H

    更新日期:2016-10-01 00:00:00

  • Impaired mechanics and matrix metalloproteinases/inhibitors expression in female ascending thoracic aortic aneurysms.

    abstract::We hypothesized that female gender may have a specific negative impact on the mechanical characteristics, composition, and expression of matrix metalloproteinases/tissue inhibitors (MMPs/TIMPs) in the wall of ascending thoracic aortic aneurysms (ATAAs). Degenerative ATAAs were resected from 35 patients (age: 67±2 year...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.02.015

    authors: Sokolis DP,Iliopoulos DC

    更新日期:2014-06-01 00:00:00

  • Nano-indentation on amorphous calcium phosphate splats: effect of droplet size on mechanical properties.

    abstract::Droplet processing technologies and many biological processes use disk-like or hemispherical shapes for construction or the design of surfaces. The ability to tune the characteristics and properties of a surface is important at the micro- and nano-scale. The influence of size on the mechanical properties is presently ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.07.014

    authors: Saber-Samandari S,Gross KA

    更新日期:2012-12-01 00:00:00

  • Simulating damage onset and evolution in fully bio-resorbable composite under three-point bending.

    abstract::This paper presents a strain-based damage model to predict the stress-strain relationship and investigate the damage onset and evolution of the fibre and matrix of a fully bio-resorbable phosphate glass fibre reinforced composite under three-point bending. The flexural properties of the composite are crucial, particul...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.02.022

    authors: Gao X,Chen M,Yang X,Harper L,Ahmed I,Lu J

    更新日期:2018-05-01 00:00:00

  • Evaluating thoracolumbar spine response during simulated underbody blast impact using a total human body finite element model.

    abstract::In a study of spine injuries in Operation Iraqi Freedom (OIF) and Operation Enduring Freedom (OEF) from 2001-09, spinal fractures sustained by mounted soldiers accounted for 26% of all injuries, and of that, 43% were caused by explosions [1]. The thoracolumbar region is the most vulnerable area of the spine [2], and i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103398

    authors: Somasundaram K,Zhang L,Sherman D,Begeman P,Lyu D,Cavanaugh JM

    更新日期:2019-12-01 00:00:00

  • Biomechanical properties of an advanced new carbon/flax/epoxy composite material for bone plate applications.

    abstract::This work is part of an ongoing program to develop a new carbon fiber/flax/epoxy (CF/flax/epoxy) hybrid composite material for use as an orthopaedic long bone fracture plate, instead of a metal plate. The purpose of this study was to evaluate the mechanical properties of this new novel composite material. The composit...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.12.013

    authors: Bagheri ZS,El Sawi I,Schemitsch EH,Zdero R,Bougherara H

    更新日期:2013-04-01 00:00:00

  • Modeling failure of soft anisotropic materials with application to arteries.

    abstract::The arterial wall is a composite where the preferred orientation of collagen fibers induces anisotropy. Though the hyperelastic theories of fiber-reinforced composites reached a high level of sophistication and showed a reasonable correspondence with the available experimental data they are short of the failure descri...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.01.002

    authors: Volokh KY

    更新日期:2011-11-01 00:00:00

  • Intrafibrillar plasticity through mineral/collagen sliding is the dominant mechanism for the extreme toughness of antler bone.

    abstract::The inelastic deformability of the mineralised matrix in bones is critical to their high toughness, but the nanoscale mechanisms are incompletely understood. Antler is a tough bone type, with a nanostructure composed of mineralised collagen fibrils ∼100nm diameter. We track the fibrillar deformation of antler tissue d...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.03.020

    authors: Gupta HS,Krauss S,Kerschnitzki M,Karunaratne A,Dunlop JW,Barber AH,Boesecke P,Funari SS,Fratzl P

    更新日期:2013-12-01 00:00:00

  • Fatigue and durability of Nitinol stents.

    abstract::Nitinol self-expanding stents are effective in treating peripheral artery disease, including the superficial femoral, carotid, and renal arteries. However, fracture occurrences of up to 50% have been reported in some stents after one year. These stent fractures are likely due to in vivo cyclic displacements. As such, ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2007.08.001

    authors: Pelton AR,Schroeder V,Mitchell MR,Gong XY,Barney M,Robertson SW

    更新日期:2008-04-01 00:00:00

  • Reliable measurement of elastic modulus of cells by nanoindentation in an atomic force microscope.

    abstract::The elastic modulus of an oral cancer cell line UM1 is investigated by nanoindentation in an atomic force microscope with a flat-ended tip. The commonly used Hertzian method gives apparent elastic modulus which increases with the loading rate, indicating strong effects of viscoelasticity. On the contrary, a rate-jump ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.11.010

    authors: Zhou ZL,Ngan AH,Tang B,Wang AX

    更新日期:2012-04-01 00:00:00

  • Planar biaxial extension of the lumbar facet capsular ligament reveals significant in-plane shear forces.

    abstract::The lumbar facet capsular ligament (FCL) articulates with six degrees of freedom during spinal motions of flexion/extension, lateral bending, and axial rotation. The lumbar FCL is composed of highly aligned collagen fiber bundles on the posterior surface (oriented primarily laterally between the rigid articular facets...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.08.019

    authors: Claeson AA,Barocas VH

    更新日期:2017-01-01 00:00:00

  • Characterization and fatigue damage of plasma sprayed HAp top coat with Ti and HAp/Ti bond coat layers on commercially pure titanium substrate.

    abstract::The surface of commercially pure Ti (cp-Ti) substrate was grit-blasted with Al(2)O(3) powders and then wet-blasted with HAp/Ti mixed powders at room temperature. Then plasma spraying with Ti powders or HAp/Ti mixed powders on the blasted surface was carried out to form a bond coat layer, denoted as T50 and T100 bond c...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.11.001

    authors: Rakngarm A,Mutoh Y

    更新日期:2009-10-01 00:00:00

  • An experimental study to investigate biomechanical aspects of the initial stability of press-fit implants.

    abstract::Initial fixation of press-fit implants depends on interference fit, surface morphology, and bone material properties. To understand the biomechanical effect of each factor and their interactions, the pull-out strength of seven types of CoCrMo tapered implants, with four different interference fits, three different sur...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.11.014

    authors: Berahmani S,Janssen D,van Kessel S,Wolfson D,de Waal Malefijt M,Buma P,Verdonschot N

    更新日期:2015-02-01 00:00:00

  • Mechanical properties of Indonesian-made narrow dynamic compression plate.

    abstract::Osteosynthesis plates are clinically used to fixate and position a fractured bone. They should have the ability to withstand cyclic loads produced by muscle contractions and total body weight. The very high demand for osteosynthesis plates in developing countries in general and in Indonesia in particular necessitates ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.04.018

    authors: Dewo P,van der Houwen EB,Sharma PK,Magetsari R,Bor TC,Vargas-Llona LD,van Horn JR,Busscher HJ,Verkerke GJ

    更新日期:2012-09-01 00:00:00

  • Augmentation of core decompression with synthetic bone graft does not improve mechanical properties of the proximal femur.

    abstract::Core decompression is a minimally invasive surgical technique used to treat patients with avascular necrosis of the femoral head. The procedure requires an entry hole in the lateral cortex of the femur which potentially leaves patients susceptible to subtrochanteric fractures. The purpose of this study was to determin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104263

    authors: Hockett SA,Sherrill JT,Self M,Mears SC,Barnes CL,Mannen EM

    更新日期:2021-03-01 00:00:00

  • Different models for simulation of mechanical behaviour of porous materials.

    abstract::Commercially pure Titanium (cpTi) and its alloys are the most successful metallic biomaterials for bone replacement, due to its excellent biomechanical and biofunctional balance. However, these materials have higher elastic modulus when compared with bone, leading to the stress-shielding phenomenon and promoting bone ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.01.026

    authors: Muñoz S,Castillo SM,Torres Y

    更新日期:2018-04-01 00:00:00

  • The relevance of molecular weight in the design of amorphous biodegradable polymers with optimized shape memory effect.

    abstract::The shape memory effect (SME) has long been the focus of interest of many research groups that have studied many facets of it, yet to the authors' knowledge some molecular parameters, such as the molecular weight, have been skipped. Thus, the aim of this work is to offer further insight into the shape memory effect, b...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.04.027

    authors: Petisco-Ferrero S,Fernández J,Fernández San Martín MM,Santamaría Ibarburu PA,Sarasua Oiz JR

    更新日期:2016-08-01 00:00:00

  • Biomechanics of stomach tissues and structure in patients with obesity.

    abstract::Even though bariatric surgery is one of the most effective treatment option of obesity, post-surgical weight loss is not always ensured, especially in the long term, when many patients experience weight regain. Bariatric procedures are largely based on surgeon's expertise and intra-operative decisions, while an integr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103883

    authors: Carniel EL,Albanese A,Fontanella CG,Pavan PG,Prevedello L,Salmaso C,Todros S,Toniolo I,Foletto M

    更新日期:2020-10-01 00:00:00

  • Nonlinear quasi-static finite element simulations predict in vitro strength of human proximal femora assessed in a dynamic sideways fall setup.

    abstract::Osteoporotic proximal femur fractures are caused by low energy trauma, typically when falling on the hip from standing height. Finite element simulations, widely used to predict the fracture load of femora in fall, usually include neither mass-related inertial effects, nor the viscous part of bone׳s material behavior....

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.11.026

    authors: Varga P,Schwiedrzik J,Zysset PK,Fliri-Hofmann L,Widmer D,Gueorguiev B,Blauth M,Windolf M

    更新日期:2016-04-01 00:00:00

  • Increased stiffness of collagen fibrils following cyclic tensile loading.

    abstract::Alterations in mechanical loading can induce growth and remodeling in soft connective tissues. Numerous studies have measured changes in the collagen structure and mechanical properties of cellularized native and engineered tissues in response to cyclic mechanical loading. However, a recent experimental study demonstr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.03.027

    authors: Chen ML,Ruberti JW,Nguyen TD

    更新日期:2018-06-01 00:00:00

  • The effect of Equal Channel Angular Pressing on the stress corrosion cracking susceptibility of AZ31 alloy in simulated body fluid.

    abstract::Despite the great potential of Mg and its alloys as material for biodegradable implants, their low resistance to the simultaneous action of corrosion and mechanical stresses in the human body have hampered their use. Stress Corrosion Cracking has been reported as one of the most critical failure modes to overcome to a...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103724

    authors: Peron M,Skaret PC,Fabrizi A,Varone A,Montanari R,Roven HJ,Ferro P,Berto F,Torgersen J

    更新日期:2020-06-01 00:00:00

  • An analytical solution for the stress state at stent-coating interfaces.

    abstract::In this paper an analytical solution for the stress state in a coated stent is presented, with a particular focus on the interface stresses between the coating and stent. As a first step a simplified stent architecture consisting of a bi-layered composite elastic arch is considered. The variations of normal and shear ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.02.009

    authors: Parry G,McGarry P

    更新日期:2012-06-01 00:00:00

  • A study of extracellular matrix remodeling in aortic heart valves using a novel biaxial stretch bioreactor.

    abstract::In aortic valves, biaxial cyclic stretch is known to modulate cell differentiation, extracellular matrix (ECM) synthesis and organization. We designed a novel bioreactor that can apply independent and precise stretch along radial and circumferential directions in a tissue culture environment. While this bioreactor can...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.041

    authors: Lei Y,Masjedi S,Ferdous Z

    更新日期:2017-11-01 00:00:00

  • The error of tensile strength tests and an approach for improvement.

    abstract:OBJECTIVES:The deviation and spread of values measured by tensile strength tests should be significantly reduced by optimized axially pull-off-device. MATERIAL AND METHODS:Factors like geometry, roughness, surface texture and fit of the specimens, the luting procedure (mixing ratio, compacting pressure) were standardi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.003

    authors: Behr M,Fuerst J,Rosentritt M

    更新日期:2018-11-01 00:00:00

  • Crack initiation from a clinically relevant notch in a highly-crosslinked UHMWPE subjected to static and cyclic loading.

    abstract::Crosslinked Ultra High Molecular Weight Polyethylene (UHMWPE), which is used as a bearing material in total joint replacement components, is subjected to static and cyclic loads in vivo. Resistance to crack initiation from a notch as a function of static and cyclic loads is not well understood for crosslinked UHMWPE. ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.12.032

    authors: Sirimamilla A,Rimnac CM

    更新日期:2019-03-01 00:00:00

  • Bayesian inference of constitutive model parameters from uncertain uniaxial experiments on murine tendons.

    abstract::Constitutive models for biological tissue are typically formulated as a mixture of constituents and the overall response is then assembled by superposition or compatibility. This ensures the stress response of the biological tissue to be in the range of a given constitutive relationship, guaranteeing that at least one...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.04.037

    authors: Akintunde AR,Miller KS,Schiavazzi DE

    更新日期:2019-08-01 00:00:00

  • Prevention of intestinal adhesion and regeneration of abdominal wall tissue with meshes containing an electrostatically spun acellular dermal matrix (ADM)/silk fibroin (SF) fiber composite polypropylene mesh.

    abstract::The repair of abdominal wall defects often requires the use of polypropylene (PP) as the main material. After a PP mesh is implanted in the body, contact with the intestine can cause adhesions between the intestine and the mesh, leading to serious complications such as intestinal fistula. In this study, we used electr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104087

    authors: Yang D,Song Z,Lin Y,Dong W,Fu S,Yang J,Zhang P,Gu Y

    更新日期:2020-12-01 00:00:00

  • Biomechanical evaluation of laser-etched Ti implant surfaces vs. chemically modified SLA Ti implant surfaces: Removal torque and resonance frequency analysis in rabbit tibias.

    abstract:PURPOSE:To compare osseointegration and implant stability of two types of laser-etched (LE) Ti implants with a chemically-modified, sandblasted, large-grit and acid-etched (SLA) Ti implant (SLActive(®), Straumann, Basel, Switzerland), by evaluating removal torque and resonance frequency between the implant surface and ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.034

    authors: Lee JT,Cho SA

    更新日期:2016-08-01 00:00:00

  • On the wear behavior and damage mechanism of bonded interface: Ceramic vs resin composite inlays.

    abstract::Advances in adhesive technologies have increased indications for the use of inlays. Decrease in the bonded interface integrity due to wear has been cited as the main cause of its failure. However, this process of interface degradation and the influence of inlay material on damage mechanism appear to be poorly understo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103430

    authors: Yu P,Xiong Y,Zhao P,Xu Z,Yu H,Arola D,Gao S

    更新日期:2020-01-01 00:00:00