Understanding hydration effects on mechanical and impacting properties of turtle shell.

Abstract:

:Study of the properties of natural biomaterials provides a reliable experimental basis for the design of biomimetic materials. The mechanical properties and impact wear behaviors of turtle shell with different soaking time were investigated on a micro-amplitude impact wear tester. The damage behavior of turtle shells with different soaking time and impact cycles were systematically analyzed, also the impact dynamics behavior was inspected during the impact wear progress. The results showed that the energy absorption and impact contact force were significantly different with varied soaking time. Under different impact cycles, the peak contact force of shell samples with same soaking time were approximate to each other in value and the values of impact contact time change in a small range. However, the damage extent of shells were distinct with varied impact cycles. It was found that impact worn scars of shells increase with impact cycles increasing. However, under the same impact cycles, energy absorption and contact time increased with the extending of soaking time, but the peak contact force decrease. Especially shell without soaking, the absorption rate is the lowest.

authors

Zhang X,Cai ZB,Li W,Zhu MH

doi

10.1016/j.jmbbm.2017.11.007

subject

Has Abstract

pub_date

2018-02-01 00:00:00

pages

116-123

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(17)30476-9

journal_volume

78

pub_type

杂志文章
  • Reliable measurement of elastic modulus of cells by nanoindentation in an atomic force microscope.

    abstract::The elastic modulus of an oral cancer cell line UM1 is investigated by nanoindentation in an atomic force microscope with a flat-ended tip. The commonly used Hertzian method gives apparent elastic modulus which increases with the loading rate, indicating strong effects of viscoelasticity. On the contrary, a rate-jump ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.11.010

    authors: Zhou ZL,Ngan AH,Tang B,Wang AX

    更新日期:2012-04-01 00:00:00

  • Bone healing response in cyclically loaded implants: Comparing zero, one, and two loading sessions per day.

    abstract::When bone implants are loaded, they are inevitably subjected to displacement relative to bone. Such micromotion generates stress/strain states at the interface that can cause beneficial or detrimental sequels. The objective of this study is to better understand the mechanobiology of bone healing at the tissue-implant ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.05.044

    authors: de Barros E Lima Bueno R,Dias AP,Ponce KJ,Wazen R,Brunski JB,Nanci A

    更新日期:2018-09-01 00:00:00

  • Prediction of cross section fracture path of cortical bone through nanoindentation array.

    abstract::Although great progresses in the fracture mechanisms and deformation behaviors of cortical bones have been achieved, the effective methods to predict the surface fracture path of cortical bones are still difficult. By using depth-sensing nanoindentation measurement technique, the hardness distribution map of cortical ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104303

    authors: Ma Z,Qiang Z,Zeng K,Xiao J,Zhou L,Zu L,Zhao H,Ren L

    更新日期:2021-01-20 00:00:00

  • Comparison of microsphere penetration with LC Bead LUMI™ versus other commercial microspheres.

    abstract::The purpose of this study was to evaluate LC Bead LUMI™ (40-90µm and 70-150µm) in order to determine if their increased resistance to compression influences microsphere penetration and distribution compared to more compressible commercial microspheres. LC Bead LUMI™ 40-90µm and 70-150µm, LC BeadM1® 70-150µm, Embozene™...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.10.034

    authors: Caine M,Zhang X,Hill M,Guo W,Ashrafi K,Bascal Z,Kilpatrick H,Dunn A,Grey D,Bushby R,Bushby A,Willis SL,Dreher MR,Lewis AL

    更新日期:2018-02-01 00:00:00

  • Two-piece zirconia oral implants withstand masticatory loads: An investigation in the artificial mouth.

    abstract:OBJECTIVE:To evaluate the fracture resistance of two-piece zirconia oral implants after long-term thermomechanical cycling in an aqueous environment. Non-loaded samples and a one-piece implant system served as control groups. METHODS:A total of 48 zirconia implants were evaluated: 16 one-piece implants (ATZ; Group A) ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.07.005

    authors: Spies BC,Nold J,Vach K,Kohal RJ

    更新日期:2016-01-01 00:00:00

  • Evaluation of four surface coating treatments for resin to zirconia bonding.

    abstract:OBJECTIVES:To compare the effects of four surface coating methods on resin to zirconia shear bond strength. MATERIAL AND METHODS:Eighty pre-sintered zirconia discs were prepared and randomly divided into five study groups according to the corresponding methods of surface treatments as follows: group C (control group, ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.12.011

    authors: Liu D,Pow EHN,Tsoi JK,Matinlinna JP

    更新日期:2014-04-01 00:00:00

  • Micromechanical modelling of oil palm empty fruit bunch fibres containing silica bodies.

    abstract::Experimental and numerical investigation was conducted to study the micromechanics of oil palm empty fruit bunch fibres containing silica bodies. The finite viscoelastic-plastic material model called Parallel Rheological Network model was proposed, that fitted well with cyclic and stress relaxation tensile tests of th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.04.043

    authors: Omar FN,Hanipah SH,Xiang LY,Mohammed MAP,Baharuddin AS,Abdullah J

    更新日期:2016-09-01 00:00:00

  • Study of indentation of a sample equine bone using finite element simulation and single cycle reference point indentation.

    abstract::In an attempt to study the mechanical behavior of bone under indentation, methods of analyses and experimental validations have been developed, with a selected test material. The test material chosen is from an equine cortical bone. Stress-strain relationships are first obtained from conventional mechanical property t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.11.020

    authors: Hoffseth K,Randall C,Hansma P,Yang HT

    更新日期:2015-02-01 00:00:00

  • Cutting mechanics of wood by beetle larval mandibles.

    abstract::Wood boring is a feature of several insect species and is a major cause of severe and irreparable damage to trees. Adult females typically deposit their eggs on the stem surface under bark scales. The emerging hatchlings live within wood during their larval phase, avoiding possible predation, whilst continually boring...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104027

    authors: Kundanati L,Chahare NR,Jaddivada S,Karkisaval AG,Sridhar R,Pugno NM,Gundiah N

    更新日期:2020-12-01 00:00:00

  • Effect of grinding with diamond-disc and -bur on the mechanical behavior of a Y-TZP ceramic.

    abstract::This study compared the effects of grinding on the surface micromorphology, phase transformation (t→m), biaxial flexural strength and structural reliability (Weibull analysis) of a Y-TZP (Lava) ceramic using diamond-discs and -burs. 170 discs (15×1.2mm) were produced and divided into 5 groups: without treatment (Ctrl,...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.05.010

    authors: Pereira GK,Amaral M,Simoneti R,Rocha GC,Cesar PF,Valandro LF

    更新日期:2014-09-01 00:00:00

  • Is short term intraoperative application of disinfectants harmful to breast implants in breast reconstruction? An experimental study and literature survey.

    abstract:OBJECTIVES:Bacterial contamination of breast implants and biofilm formation has been discussed as a major reason for implant loss and capsular contraction. Intra- and perioperative treatment of breast implants with disinfectants to prevent bacterial contamination has been frequently reported. Given the increasing aware...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.10.021

    authors: Schmitz M,Schubert DW,Kaschta J,Daenicke J,Walter BL,Horch RE

    更新日期:2019-02-01 00:00:00

  • The effect of ethanol on surface of semi-interpenetrating polymer network (IPN) polymer matrix of glass-fibre reinforced composite.

    abstract:AIM OF THE STUDY:The aim of this laboratory study was to evaluate the effect of ethanol treatment on the surface roughness (Sa), nano-mechanical properties (NMP) and surface characterization of dental fiber reinforced composite (FRC) with semi-interpenetrating polymer network (IPN). MATERIALS AND METHODS:A total of 24...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.030

    authors: Basavarajappa S,Perea-Lowery L,Aati S,Abdullah Al-Kheraif AA,Ramakrishnaiah R,Matinlinna JP,Vallittu PK

    更新日期:2019-10-01 00:00:00

  • Fatigue behavior of Ti6Al4V and 316 LVM blasted with ceramic particles of interest for medical devices.

    abstract::Grit blasting is used as a cost-effective method to increase the surface roughness of metallic biomaterials, as Ti6Al4V and 316 LVM, to enhance the osteointegration, fixation and stability of implants. Samples of these two alloys were blasted by using alumina and zirconia particles, yielding rough (up to Ra~8μm) and n...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.10.013

    authors: Barriuso S,Chao J,Jiménez JA,García S,González-Carrasco JL

    更新日期:2014-02-01 00:00:00

  • Deterioration of the mechanical properties of calcium phosphate cements with Poly (γ-glutamic acid) and its strontium salt after in vitro degradation.

    abstract::The mechanical reliability of calcium phosphate cements has restricted their clinical application in load-bearing locations. Although their mechanical strength can be improved using a variety of strategies, their fatigue properties are still unclear, especially after degradation. The evolutions of uniaxial compressive...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.026

    authors: Liang T,Gao CX,Yang L,Saijilafu,Yang HL,Luo ZP

    更新日期:2017-11-01 00:00:00

  • Mechanical properties, electrochemical corrosion and in-vitro bioactivity of yttria stabilized zirconia reinforced hydroxyapatite coatings prepared by gas tunnel type plasma spraying.

    abstract::Yttria stabilized zirconia reinforced hydroxyapatite coatings were deposited by a gas tunnel type plasma spray torch under optimum spraying conditions. For this purpose, 10, 20 and 30 wt% of yttria stabilized zirconia (YSZ) powders were premixed individually with hydroxyapatite (HA) powder and were used as the feedsto...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.11.002

    authors: Yugeswaran S,Yoganand CP,Kobayashi A,Paraskevopoulos KM,Subramanian B

    更新日期:2012-05-01 00:00:00

  • Cell adhesion to plasma electrolytic oxidation (PEO) titania coatings, assessed using a centrifuging technique.

    abstract::The adhesion of bovine chondrocytes and human osteoblasts to three titania-based coatings, formed by plasma electrolytic oxidation (PEO), was compared to that on uncoated Ti-6Al-4V substrates, and some comparisons were also made with plasma sprayed hydroxyapatite (HA) coatings. This was done using a centrifuge, with a...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.07.009

    authors: Robinson HJ,Markaki AE,Collier CA,Clyne TW

    更新日期:2011-11-01 00:00:00

  • Relationship between various deformation-induced products and mechanical properties in metastable Ti-30Zr-Mo alloys for biomedical applications.

    abstract::Nowadays, there is a significant research focus on the development of bio-implant materials that have not only a low Young's modulus but also other unique characteristics such as a changeable Young's modulus and the ability to prevent calcium phosphate formation. Taking advantage of deformation-induced phases is an ef...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.06.020

    authors: Zhao X,Niinomi M,Nakai M

    更新日期:2011-11-01 00:00:00

  • Damage initiation and progression in the cartilage surface probed by nonlinear optical microscopy.

    abstract::With increasing interest in treating osteoarthritis at its earliest stages, it has become important to understand the mechanisms by which the disease progresses across a joint. Here, second harmonic generation (SHG) microscopy, coupled with a two-dimensional spring-mass network model, was used to image and investigate...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.08.004

    authors: Brown CP,Houle MA,Chen M,Price AJ,Légaré F,Gill HS

    更新日期:2012-01-01 00:00:00

  • Design of a remote-control drug delivery implantable chip for cancer local on demand therapy using ionic polymer metal composite actuator.

    abstract::Since the local, on demand, cancer therapy is a challenging clinical issue today, this paper presents the design, fabrication and characterization of a remotely controlled single reservoir drug delivery chip using Ionic Polymer Metal Composite (IPMC) actuator. Here, Drug release was externally programmed and controlle...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.06.034

    authors: Saneei Mousavi MS,Karami AH,Ghasemnejad M,Kolahdouz M,Manteghi F,Ataei F

    更新日期:2018-10-01 00:00:00

  • Fatigue life of bovine meniscus under longitudinal and transverse tensile loading.

    abstract::The knee meniscus is composed of a fibrous extracellular matrix that is subjected to large and repeated loads. Consequently, the meniscus is frequently torn, and a potential mechanism for failure is fatigue. The objective of this study was to measure the fatigue life of bovine meniscus when applying cyclic tensile loa...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.12.020

    authors: Creechley JJ,Krentz ME,Lujan TJ

    更新日期:2017-05-01 00:00:00

  • Interfacial indentations in biological composites.

    abstract::Biocomposites comprise highly stiff reinforcement elements connected by a compliant matrix material. While the interfacial elastic properties of these biocomposites play a key role in determining the mechanical properties of the entire biocomposite, these properties cannot be measured directly from standard nanomechan...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104209

    authors: Shelef Y,Bar-On B

    更新日期:2021-02-01 00:00:00

  • A novel prime-&-rinse mode using MDP and MMPs inhibitors improves the dentin bond durability of self-etch adhesive.

    abstract:OBJECTIVES:The study investigated the effects of novel prime-&-rinse mode using MDP (10-methacryloyloxydecyl dihydrogenphosphate) and matrix metalloproteinase (MMPs) inhibitors on dentin microtensile bond strengths (MTBS) of self-etch adhesive, resin-dentin interface degradations, and activity of recombinant human (rh)...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103698

    authors: Xu J,Li M,Wang W,Wu Z,Wang C,Jin X,Zhang L,Jiang W,Fu B

    更新日期:2020-04-01 00:00:00

  • Statistics in experimental studies on the human spine: Theoretical basics and review of applications.

    abstract::Proper statistical analysis is essential in the research studies. In particular, as regards the in vitro testing of the lumbar spine, the criteria for the standardization have been extensively discussed but the use of statistics has not been reviewed. Unfortunately, cadaveric testing is a very difficult and complex ex...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103862

    authors: Bassani T,Galbusera F

    更新日期:2020-10-01 00:00:00

  • Development of a bite force transducer for measuring maximum voluntary bite forces between individual opposing tooth surfaces.

    abstract::Bite forces are studied in order to understand a wide range of factors pertaining to the mastication system. Various strain gauge transducers have been employed to measure bite forces, with several descriptions of these available in the literature; unfortunately, many reports provide insufficient detail to enable accu...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103846

    authors: Jansen van Vuuren L,Jansen van Vuuren WA,Broadbent JM,Duncan WJ,Waddell JN

    更新日期:2020-09-01 00:00:00

  • Hydrogels with differential and patterned mechanics to study stiffness-mediated myofibroblastic differentiation of hepatic stellate cells.

    abstract::The differentiation of hepatic stellate cells (HSCs) into myofibroblasts is a key event in liver fibrosis. Due to the local stiffening of the extracellular matrix (ECM) during fibrosis, it is of great interest to develop mimics that can be used to investigate the cellular response to changes in mechanics. Here, we use...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.11.008

    authors: Guvendiren M,Perepelyuk M,Wells RG,Burdick JA

    更新日期:2014-10-01 00:00:00

  • Structure and mechanical behaviors of protective armored pangolin scales and effects of hydration and orientation.

    abstract::As natural flexible dermal armor, pangolin scales provide effective protection against predatory threats and possess other notable properties such as anti-adhesion and wear-resistance. In this study, the structure, mechanical properties, deformation and damage behaviors of pangolin scales were systematically investiga...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.11.013

    authors: Liu ZQ,Jiao D,Weng ZY,Zhang ZF

    更新日期:2016-03-01 00:00:00

  • Comparison of biaxial mechanical properties of coronary sinus tissues from porcine, ovine and aged human species.

    abstract::Due to its proximity to the mitral valve, the coronary sinus (CS) vessel serves as a conduit for the deployment and implantation of the percutaneous transvenous mitral annuloplasty (PTMA) devices that can potentially reduce the mitral regurgitation. Because CS vessel is a venous tissue and seldom diseased, its mechani...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.09.001

    authors: Pham T,Sun W

    更新日期:2012-02-01 00:00:00

  • Sensing inhomogeneous mechanical properties of human corneal Descemet's membrane with AFM nano-indentation.

    abstract::The paper describes a highly space-resolved characterization of the surface mechanical properties of the posterior human corneal layer (Descemet's membrane). This has been accomplished with Atomic Force Microscopy (AFM) nano-indentation by using a probe with a sharp tip geometry. Results indicate that the contact with...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.05.019

    authors: Di Mundo R,Recchia G,Parekh M,Ruzza A,Ferrari S,Carbone G

    更新日期:2017-10-01 00:00:00

  • Influence of viscoelasticity of protein on the toughness of bone.

    abstract::Bone is an ultrafine composite of protein (collagen) and mineral (hydroxyapatite). An analysis to determine the influence of the viscoelasticity of protein on the toughness of bone at the ultrafine scale is conducted by developing a discrete lattice model appropriate for the ultrafine scale called the incremental cont...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2009.10.007

    authors: Anup S,Sivakumar SM,Suraishkumar GK

    更新日期:2010-04-01 00:00:00

  • Cold-rolling behavior of biomedical Ni-free Co-Cr-Mo alloys: Role of strain-induced ε martensite and its intersecting phenomena.

    abstract::Ni-free Co-Cr-Mo alloys are some of the most difficult-to-work metallic materials used commonly in biomedical applications. Since the difficulty in plastically deforming them limits their use, an in-depth understanding of their plastic deformability is of crucial importance for both academic and practical purposes. In...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.10.021

    authors: Mori M,Yamanaka K,Chiba A

    更新日期:2015-03-01 00:00:00