Cell adhesion to plasma electrolytic oxidation (PEO) titania coatings, assessed using a centrifuging technique.

Abstract:

:The adhesion of bovine chondrocytes and human osteoblasts to three titania-based coatings, formed by plasma electrolytic oxidation (PEO), was compared to that on uncoated Ti-6Al-4V substrates, and some comparisons were also made with plasma sprayed hydroxyapatite (HA) coatings. This was done using a centrifuge, with accelerations of up to 160,000 g, so as to induce buoyancy forces that created normal or shear stresses at the interface. It is shown that, on all surfaces, it was easier to remove cells under normal loading than under shear loading. Cell adhesion to the PEO coatings was stronger than that on Ti-6Al-4V and similar to that on HA. Cell proliferation rates were relatively high on one of the PEO coatings, which was virtually free of aluminium, but low on the other two, which contained significant levels of aluminium. It is concluded that the Al-free PEO coating offers promise for application to prosthetic implants.

authors

Robinson HJ,Markaki AE,Collier CA,Clyne TW

doi

10.1016/j.jmbbm.2011.07.009

subject

Has Abstract

pub_date

2011-11-01 00:00:00

pages

2103-12

issue

8

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(11)00196-2

journal_volume

4

pub_type

杂志文章
  • Adhesion of ligand-conjugated biosynthesized magnetite nanoparticles to triple negative breast cancer cells.

    abstract::This paper presents the results of an experimental study of the adhesion forces between components of model conjugated magnetite nanoparticle systems for improved selectivity in the specific targeting of triple negative breast cancer. Adhesion forces between chemically synthesized magnetite nanoparticles (CMNPs), bios...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.02.004

    authors: Obayemi JD,Hu J,Uzonwanne VO,Odusanya OS,Malatesta K,Anuku N,Soboyejo WO

    更新日期:2017-04-01 00:00:00

  • A mesoscale study of the degradation of bone structural properties in modeled microgravity conditions.

    abstract::One of the most important alterations that occur in man and experimental animals during spaceflight concerns the skeletal system, and entails important bone loss and degradation of mechanical properties. In the present work we investigate ex vivo the long-term effects of weightlessness (simulated microgravity) on bone...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.01.002

    authors: Cosmi F,Steimberg N,Mazzoleni G

    更新日期:2015-04-01 00:00:00

  • Influence of biocorrosion on microstructure and mechanical properties of deformed Mg-Y-Er-Zn biomaterial containing 18R-LPSO phase.

    abstract::The microstructure and mechanical properties of as-extruded Mg-8Y-1Er-2Zn (wt%) alloy containing long period stacking ordered (LPSO) phase are comparatively investigated before and after corrosion in a simulated body fluid (SBF) at 37°C. The as-extruded alloy consists of a long strip-like 18R-LPSO phase and some fine ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.012

    authors: Leng Z,Zhang J,Yin T,Zhang L,Guo X,Peng Q,Zhang M,Wu R

    更新日期:2013-12-01 00:00:00

  • Biocompatibility and compressive properties of Ti-6Al-4V scaffolds having Mg element.

    abstract::Porous scaffolds of Ti-6Al-4V were produced by mixing of this alloy with different amount of magnesium (Mg) powders. The mixtures were compacted in steel die by applying uniaxial pressure of 500 MPa before sintering the compacts in sealed quartz tubes at 900 °C for 2 h. Employing Archimedes׳ principle and Image Tool s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.04.015

    authors: Kalantari SM,Arabi H,Mirdamadi S,Mirsalehi SA

    更新日期:2015-08-01 00:00:00

  • "Force-from-lipids" gating of mechanosensitive channels modulated by PUFAs.

    abstract::The level of fatty acid saturation in phospholipids is a crucial determinant of the biophysical properties of the lipid bilayer. Integral membrane proteins are sensitive to changes of their bilayer environment such that their activities and localization can be profoundly affected. When incorporated into phospholipids ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.12.026

    authors: Ridone P,Grage SL,Patkunarajah A,Battle AR,Ulrich AS,Martinac B

    更新日期:2018-03-01 00:00:00

  • Mechanical performance of Y-TZP monolithic ceramic after grinding and aging: Survival estimates and fatigue strength.

    abstract::This study aims to evaluate the flexural fatigue strength and survival estimates of an Y-TZP monolithic ceramic after grinding and aging. Ceramic discs (1.2 mm thickness × 15.0 mm diameter - ISO, 6872, 2015) of zirconia (Zirlux FC2 - Ardent; Ivoclar Vivadent) were made and randomly allocated into 6 groups (n = 10), ac...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.041

    authors: Dapieve KS,Guilardi LSF,Silvestri T,Rippe MP,Pereira GKR,Valandro LF

    更新日期:2018-11-01 00:00:00

  • Periprosthetic wear particle migration and distribution modelling and the implication for osteolysis in cementless total hip replacement.

    abstract::In total hip replacement (THR), wear particles play a significant role in osteolysis and have been observed in locations as remote as the tip of femoral stem. However, there is no clear understanding of the factors and mechanisms causing, or contributing to particle migration to the periprosthetic tissue. Interfacial ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.01.005

    authors: Alidousti H,Taylor M,Bressloff NW

    更新日期:2014-04-01 00:00:00

  • Constitutive modeling of the passive inflation-extension behavior of the swine colon.

    abstract::In the present work, we propose the first structural constitutive model of the passive mechanical behavior of the swine colon that is validated against physiological inflation-extension tests, and accounts for residual strains. Sections from the spiral colon and the descending colon were considered to investigate pote...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.031

    authors: Patel B,Chen H,Ahuja A,Krieger JF,Noblet J,Chambers S,Kassab GS

    更新日期:2018-01-01 00:00:00

  • Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting.

    abstract::Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platele...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.05.010

    authors: Murr LE,Amato KN,Li SJ,Tian YX,Cheng XY,Gaytan SM,Martinez E,Shindo PW,Medina F,Wicker RB

    更新日期:2011-10-01 00:00:00

  • Biomechanical and biochemical protective effect of low-level laser therapy for Achilles tendinitis.

    abstract::For three decades, low level laser therapy (LLLT) has been used for treatment of tendinitis as well as other musculoskeletal diseases. Nevertheless, the biological mechanisms involved remain not completely understood. In this work, the effects of LLLT and of the widely used nonsteroidal anti-inflammatory drug, diclofe...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.028

    authors: Marcos RL,Arnold G,Magnenet V,Rahouadj R,Magdalou J,Lopes-Martins RÁ

    更新日期:2014-01-01 00:00:00

  • Strain-induced microstructural rearrangement in ultra-high molecular weight polyethylene for hip joints: A comparison between conventional and vitamin E-infused highly-crosslinked liners.

    abstract::Infusion of vitamin E (α-tocopherol) in highly crosslinked ultra-high molecular weight polyethylene (UHMWPE) liners has been conceived to achieve superior oxidation stability while preserving enhanced mechanical properties as compared to post-irradiation remelted liners. However, the presence of an antioxidant in the ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.12.009

    authors: Takahashi Y,Yamamoto K,Shishido T,Masaoka T,Tateiwa T,Puppulin L,Pezzotti G

    更新日期:2014-03-01 00:00:00

  • Layer-specific damage experiments and modeling of human thoracic and abdominal aortas with non-atherosclerotic intimal thickening.

    abstract::Many treatments for cardiovascular diseases include an endovascular insertion of stents or stent grafts into arteries, a procedure which may cause high tissue stresses and even damage in the arterial wall. In order to study such problems by using finite element methods, both appropriate constitutive models and experim...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.03.012

    authors: Weisbecker H,Pierce DM,Regitnig P,Holzapfel GA

    更新日期:2012-08-01 00:00:00

  • Nonlinear quasi-static finite element simulations predict in vitro strength of human proximal femora assessed in a dynamic sideways fall setup.

    abstract::Osteoporotic proximal femur fractures are caused by low energy trauma, typically when falling on the hip from standing height. Finite element simulations, widely used to predict the fracture load of femora in fall, usually include neither mass-related inertial effects, nor the viscous part of bone׳s material behavior....

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.11.026

    authors: Varga P,Schwiedrzik J,Zysset PK,Fliri-Hofmann L,Widmer D,Gueorguiev B,Blauth M,Windolf M

    更新日期:2016-04-01 00:00:00

  • Anatomic variation in the elastic anisotropy of cortical bone tissue in the human femur.

    abstract::Experimental investigations for anatomic variation in the magnitude and anisotropy of elastic constants in human femoral cortical bone tissue have typically focused on a limited number of convenient sites near the mid-diaphysis. However, the proximal and distal ends of the diaphysis are more clinically relevant to com...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.08.005

    authors: Espinoza Orías AA,Deuerling JM,Landrigan MD,Renaud JE,Roeder RK

    更新日期:2009-07-01 00:00:00

  • Correlations between transmural mechanical and morphological properties in porcine thoracic descending aorta.

    abstract::Determination of correlations between transmural mechanical and morphological properties of aorta would provide a quantitative baseline for assessment of preventive and therapeutic strategies for aortic injuries and diseases. A multimodal and multidisciplinary approach was adopted to characterize the transmural morpho...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.004

    authors: Hemmasizadeh A,Tsamis A,Cheheltani R,Assari S,D'Amore A,Autieri M,Kiani MF,Pleshko N,Wagner WR,Watkins SC,Vorp D,Darvish K

    更新日期:2015-07-01 00:00:00

  • Microstructural features influencing the mechanical performance of the Brazil nut (Bertholletia excelsa) mesocarp.

    abstract::Brazil nut (Bertholletia excelsa) fruits are capable of resisting high mechanical forces when released from trees as tall as 50 m, as well as during animal dispersal by sharp-teethed rodents. Thick mesocarp plays a crucial part in seed protection. We investigated the role of microstructure and how sclereids, fibers, a...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104306

    authors: Sonego M,Madia M,Eder M,Fleck C,Pessan LA

    更新日期:2021-01-07 00:00:00

  • The effect of aging on the mechanical behaviour of cuticle in the locust Schistocerca gregaria.

    abstract::Despite some previous work on the morphology and mechanical properties of parts of the insect exoskeleton, there is very little known about how these properties change over time during the life of the insect. We examined the hind tibia of the adult desert locust (Schistocerca gregaria) as a function of time up to 63 d...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.02.008

    authors: Parle E,Taylor D

    更新日期:2017-04-01 00:00:00

  • Fibroblast populated collagen lattices exhibit opposite biophysical conditions by fibrin or hyaluronic acid supplementation.

    abstract::Fibrin and hyaluronic acid are important components of the provisional wound matrix. Through interactions with fibroblasts, they provide biophysical cues that regulate the viscoelastic properties of the extracellular matrix. To understand the roles of fibrin and hyaluronic acid in a collagenous environment, we used fi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.03.042

    authors: Chopin-Doroteo M,Salgado-Curiel RM,Pérez-González J,Marín-Santibáñez BM,Krötzsch E

    更新日期:2018-06-01 00:00:00

  • Looped ends versus open ends braided stent: A comparison of the mechanical behaviour using analytical and numerical methods.

    abstract::The present study has two major purposes: firstly, to investigate whether the analytical model proposed by Jedwab and Clerc for assessing the mechanical behaviour of an open ends metallic braided stent is applicable to the looped ends stent design and secondly, to compare the response of the two stent designs subjecte...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.025

    authors: Shanahan C,Tiernan P,Tofail SAM

    更新日期:2017-11-01 00:00:00

  • Preparation and properties of an injectable scaffold of poly(lactic-co-glycolic acid) microparticles/chitosan hydrogel.

    abstract::Hydrogels are more and more attractive in biomedical fields, since they can be used as injectable scaffolds, drugs and gene carriers and smart sensors. The highly hydrated hydrogels, however, generally have low mechanical strength. In this work, a composite chitosan hydrogel was prepared by blending water soluble and ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.02.001

    authors: Hu X,Zhou J,Zhang N,Tan H,Gao C

    更新日期:2008-10-01 00:00:00

  • Reinforcing effect of graphene oxide reinforcement on the properties of poly (vinyl alcohol) and carboxymethyl tamarind gum based phase-separated film.

    abstract::The current study deals with the preparation and the characterization of the PVA-CMT-GO films. The PVA-CMT film was translucent in nature and smooth to touch. The addition of GO resulted in the formation of agglomerated structures. XRD studies suggested that the incorporation of GO increased the average crystallite si...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.02.021

    authors: Yadav I,Nayak SK,Rathnam VSS,Banerjee I,Ray SS,Anis A,Pal K

    更新日期:2018-05-01 00:00:00

  • Bending behaviors of fully covered biodegradable polydioxanone biliary stent for human body by finite element method.

    abstract::This paper presents a study of the bending flexibility of fully covered biodegradable polydioxanone biliary stents (FCBPBs) developed for human body. To investigate the relationship between the bending load and structure parameter (monofilament diameter and braid-pin number), biodegradable polydioxanone biliary stents...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.023

    authors: Liu Y,Zhu G,Yang H,Wang C,Zhang P,Han G

    更新日期:2018-01-01 00:00:00

  • Administration of PTH and ibandronate increases ovariectomized rat compact bone viscoelasticity.

    abstract::In this study, the bone mineral density (BMD), geometry, macroscopic viscoelastic properties and mechanical strength in five different groups of Sprague-Dawley rats (sham operated, ovariectomized with vehicle, parathyroid hormone and/or ibandronate administration) were examined by peripheral quantitative computed tomo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.03.009

    authors: Yang X,Teoh SH,DasDe S,Lee T

    更新日期:2013-06-01 00:00:00

  • Bioactive composite for keratoprosthesis skirt.

    abstract::In this study, the fabrication and properties of a synthetic keratoprosthesis skirt for use in osteo-odonto-keratoprosthesis (OOKP) surgery are discussed. In the search for a new material concept, bioactive glass and polymethyl methacrylate (PMMA)-based composites were prepared. Three different bioactive glasses (i.e....

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.05.025

    authors: Laattala K,Huhtinen R,Puska M,Arstila H,Hupa L,Kellomäki M,Vallittu PK

    更新日期:2011-11-01 00:00:00

  • Statistics in experimental studies on the human spine: Theoretical basics and review of applications.

    abstract::Proper statistical analysis is essential in the research studies. In particular, as regards the in vitro testing of the lumbar spine, the criteria for the standardization have been extensively discussed but the use of statistics has not been reviewed. Unfortunately, cadaveric testing is a very difficult and complex ex...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103862

    authors: Bassani T,Galbusera F

    更新日期:2020-10-01 00:00:00

  • Fabrication of tissue-engineered tympanic membrane patches using 3D-Printing technology.

    abstract::In recent years, scaffolds produced in 3D printing technology have become more widespread tool due to providing more advantages than traditional methods in tissue engineering applications. In this research, it was aimed to produce patches for the treatment of tympanic membrane perforations which caused significant hea...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104219

    authors: Ilhan E,Ulag S,Sahin A,Yilmaz BK,Ekren N,Kilic O,Sengor M,Kalaskar DM,Oktar FN,Gunduz O

    更新日期:2021-02-01 00:00:00

  • Calibration of colloidal probes with atomic force microscopy for micromechanical assessment.

    abstract::Mechanical assessment of biological materials and tissue-engineered scaffolds is increasingly focusing at lower length scale levels. Amongst other techniques, atomic force microscopy (AFM) has gained popularity as an instrument to interrogate material properties, such as the indentation modulus, at the microscale via ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.05.026

    authors: Kain L,Andriotis OG,Gruber P,Frank M,Markovic M,Grech D,Nedelkovski V,Stolz M,Ovsianikov A,Thurner PJ

    更新日期:2018-09-01 00:00:00

  • A micropolar anisotropic constitutive model of cancellous bone from discrete homogenization.

    abstract::Cosserat models of cancellous bone are constructed, relying on micromechanical approaches in order to investigate microstructure-related scale effects on the macroscopic properties of bone. The derivation of the effective mechanical properties of cancellous bone considered as a cellular solid modeled as two-dimensiona...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.07.012

    authors: Goda I,Assidi M,Belouettar S,Ganghoffer JF

    更新日期:2012-12-01 00:00:00

  • Bone healing response in cyclically loaded implants: Comparing zero, one, and two loading sessions per day.

    abstract::When bone implants are loaded, they are inevitably subjected to displacement relative to bone. Such micromotion generates stress/strain states at the interface that can cause beneficial or detrimental sequels. The objective of this study is to better understand the mechanobiology of bone healing at the tissue-implant ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.05.044

    authors: de Barros E Lima Bueno R,Dias AP,Ponce KJ,Wazen R,Brunski JB,Nanci A

    更新日期:2018-09-01 00:00:00

  • Simultaneous microstructural and mechanical characterization of human corneas at increasing pressure.

    abstract::The cornea, through its shape, is the main contributor to the eye׳s focusing power. Pathological alterations of the cornea strongly affect the eye power. To improve treatments, complex biomechanical models have been developed based on the architecture and mechanical properties of the collagen network in the stroma, th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.031

    authors: Benoit A,Latour G,Marie-Claire SK,Allain JM

    更新日期:2016-07-01 00:00:00