Abstract:
:Determination of correlations between transmural mechanical and morphological properties of aorta would provide a quantitative baseline for assessment of preventive and therapeutic strategies for aortic injuries and diseases. A multimodal and multidisciplinary approach was adopted to characterize the transmural morphological properties of descending porcine aorta. Histology and multi-photon microscopy were used for describing the media layer micro-architecture in the circumferential-radial plane, and Fourier Transform infrared imaging spectroscopy was utilized for determining structural protein, and total protein content. The distributions of these quantified properties across the media thickness were characterized and their relationship with the mechanical properties from a previous study was determined. Our findings indicate that there is an increasing trend in the instantaneous Young׳s modulus (E), elastic lamella density (ELD), structural protein (SPR), total protein (TPR), and elastin and collagen circumferential percentage (ECP and CCP) from the inner towards the outer layers. Two regions with equal thickness (inner and outer halves) were determined with significantly different morphological and material properties. The results of this study represent a substantial step toward anatomical characterization of the aortic wall building blocks and establishment of a foundation for quantifying the role of microstructural components on the functionality of aorta.
journal_name
J Mech Behav Biomed Materauthors
Hemmasizadeh A,Tsamis A,Cheheltani R,Assari S,D'Amore A,Autieri M,Kiani MF,Pleshko N,Wagner WR,Watkins SC,Vorp D,Darvish Kdoi
10.1016/j.jmbbm.2015.03.004subject
Has Abstractpub_date
2015-07-01 00:00:00pages
12-20eissn
1751-6161issn
1878-0180pii
S1751-6161(15)00084-3journal_volume
47pub_type
杂志文章abstract::A mixture of water/carbon dioxide is a "green" perspective solvent from the viewpoint of biomedical applications. Clathrate hydrates are formed this solvent under certain conditions and a very interesting question is the impact of clathrates hydrates on the structure and properties of bovine pericardium, which is used...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.11.015
更新日期:2017-03-01 00:00:00
abstract::Success of tissue engineering relies on the architecture and properties of porous scaffolds. Electrospun nonwoven scaffolds in the form of mats are unique materials due to large surface area to volume ratio, high porosity, versatility in surface functionalities and excellent mechanical properties. Maneuvering the mech...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.04.013
更新日期:2017-08-01 00:00:00
abstract::A common design constraint in functional tissue engineering is that scaffolds intended for use in load-bearing sites possess similar mechanical properties to the replaced tissue. Here, we tested the hypothesis that in vivo loading would enhance bone morphogenetic protein-2 (BMP-2)-mediated bone regeneration in the pre...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.05.010
更新日期:2016-09-01 00:00:00
abstract::The aim of the presented study was to estimate the material properties of human patellar ligaments from the elderly population by means of tensile tests. The experimental part was conducted on a custom tensile-testing device, with a built-in enclosure to simulate in-vivo conditions, using 25 (15 female, 10 male) bone-...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.103994
更新日期:2020-10-01 00:00:00
abstract::Pressure-induced deep tissue injury is a form of pressure ulcer which is difficult to detect and diagnose at an early stage, before the wound has severely progressed and becomes visible at the skin surface. At the present time, no such detection technique is available. To test the hypothesis that muscle damage biomark...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.12.026
更新日期:2019-04-01 00:00:00
abstract::With the emergence of new biomaterials and elastography imaging techniques, there is a need for innovative instruments dedicated to viscoelasticity measurements. In this work, we introduce a novel hyper-frequency viscoelastic spectroscopy (HFVS) technique dedicated to characterize soft media subjected to mid-to-very-h...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.03.020
更新日期:2011-10-01 00:00:00
abstract::In this study, Acid Soluble Collagen-g-P(methyl methacrylate-co-ethyl acrylate) (CME) was synthesized to take advantage of the flexibility of the resulted branched polymer chains and the high density of their chain entanglement. The coaxial electrospinning technique was applied to study the effect of electrically and ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.07.002
更新日期:2018-11-01 00:00:00
abstract::Infection incidence for total hip and knee arthroplasty (THA and TKA, respectively) is between 0.2% and 5% and results in approximately 100,000 device failures per year in the United States. Treatment requires prolonged systemic antibiotic therapy with additional surgical revisions. As a prophylactic measure against i...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.06.033
更新日期:2018-11-01 00:00:00
abstract::Titanium alloys (Ti-6Al-4V) are promising materials as bone implants in clinical surgeries owing to their excellent performances. However, wear debris caused by the tribological behavior of the cortical bone and titanium alloy interface were found to be paramount for implant stability. The contact environment between ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.10.031
更新日期:2019-02-01 00:00:00
abstract::We have an interest in the cellular response to mechanical stimuli, and here describe an in-vitro method to examine the response of cells cultured in a three-dimensional matrix to mechanical compressive and tensile stress. Synthetic aliphatic polyester scaffolds coated with 45S5 bioactive glass were seeded with human ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.08.006
更新日期:2018-12-01 00:00:00
abstract::Previous physiological experiments and finite element modelling indicate that inter-synergistic epimuscular myofascial force transmission (EMFT) between co-activated muscles has a potential to affect healthy muscle's contribution to joint moment and joint range of movement. This is quite relevant for patients with cer...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.08.040
更新日期:2018-01-01 00:00:00
abstract:OBJECTIVE:To introduce an experimental non-carious cervical lesion (NCCL) model for studying the influence of presence and type of stress (tension or compression) on acid effects involved in NCCL formation on the enamel near the cement-enamel junction (CEJ). METHODS:108 bovine incisors were cut into 18 × 3×3 mm3 beams...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.11.003
更新日期:2017-02-01 00:00:00
abstract::The bite force of the piranha (Serrasalmidae) has drawn considerable attention due to its ability to effectively capture and masticate prey. Herein, we analyze theoretical anterior bite forces using a lever approach and compare them to in-vivo maximum bite forces. We provide a mechanics analysis that explains the scal...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.104296
更新日期:2021-03-01 00:00:00
abstract::Porous poly(para-phenylene) (PPP) scaffolds have tremendous potential as an orthopedic biomaterial; however, the underlying mechanisms controlling the monotonic and cyclic behavior are poorly understood. The purpose of this study was to develop a method to integrate micro-computed tomography (μCT), finite-element anal...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.10.004
更新日期:2015-01-01 00:00:00
abstract::Superelastic wires and diamond-shaped stent surrogates were manufactured from Nitinol rods and tubing, respectively, from five different mill product suppliers - Standard VAR, Standard VIM, Standard VIM+VAR, Process-Optimized VIM+VAR, and High-Purity VAR. High-cycle fatigue tests up to 10(7) cycles were conducted unde...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.07.003
更新日期:2015-11-01 00:00:00
abstract::Titanium and its alloys are widely used as dental implants due to their low density, excellent biocompatibility, mechanical properties and corrosion resistance. However, during their lifetime Ti6Al4V biomedical alloys are subjected to different mechanical actions (i.e., sliding or fretting), thus resulting in a triboc...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.01.019
更新日期:2013-04-01 00:00:00
abstract::Cosserat models of cancellous bone are constructed, relying on micromechanical approaches in order to investigate microstructure-related scale effects on the macroscopic properties of bone. The derivation of the effective mechanical properties of cancellous bone considered as a cellular solid modeled as two-dimensiona...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.07.012
更新日期:2012-12-01 00:00:00
abstract::The surface of commercially pure Ti (cp-Ti) substrate was grit-blasted with Al(2)O(3) powders and then wet-blasted with HAp/Ti mixed powders at room temperature. Then plasma spraying with Ti powders or HAp/Ti mixed powders on the blasted surface was carried out to form a bond coat layer, denoted as T50 and T100 bond c...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2008.11.001
更新日期:2009-10-01 00:00:00
abstract::As a substitute for 2,2-bis[4-(2-hydroxy-3- methacryloxypropoxy)phenyl] propane (Bis-GMA) in dental materials, a new dimethacrylate monomer TDDMMA without bisphenol-A structure was synthesized through the reaction between tricyclo[5.2.1.0(2,6)]- decanedimethanol and 2-isocyanatoethyl methacrylate. The TDDMMA was mixed...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.11.020
更新日期:2016-04-01 00:00:00
abstract:OBJECTIVES:To test whether the load-bearing capacity of occlusal veneers made of ceramic or hybrid materials bonded to dentin does differ from those of porcelain-fused-to metal or lithium disilicate glass ceramic crowns. MATERIAL AND METHODS:In 80 human molars, occlusal tooth substance was removed so that the defects ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.04.006
更新日期:2019-07-01 00:00:00
abstract::The aim of the present work was twofold: to prepare biphasic magnesium fluorapatite (MFA) composites with different amounts of alumina using a two-step sintering process, and to evaluate the effects of various amounts of alumina on the mechanical properties, phase stability, and densification of the composite samples....
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.08.004
更新日期:2014-12-01 00:00:00
abstract::The knee meniscus is composed of a fibrous extracellular matrix that is subjected to large and repeated loads. Consequently, the meniscus is frequently torn, and a potential mechanism for failure is fatigue. The objective of this study was to measure the fatigue life of bovine meniscus when applying cyclic tensile loa...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.12.020
更新日期:2017-05-01 00:00:00
abstract::In this study, the relationship between deformation mechanism and rolling reductions was investigated, and the effects of deformation reductions on the microstructure and mechanical properties of the alloys both cold rolled and aged were revealed. It was found that the equiaxed β grains of the Ti-30Nb-5Ta-6Zr alloy ha...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.06.006
更新日期:2013-11-01 00:00:00
abstract::Nickel and carbides free Co-28Cr-6Mo alloy was fabricated by combination of mechanical alloying and warm pressing. The microstructure, mechanical properties, pin-on-disk dry sliding wear and corrosion behavior in simulated physiological solution were investigated. The produced Co-28Cr-6Mo alloy has elongated ultra-fin...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.12.039
更新日期:2016-07-01 00:00:00
abstract::We aimed to investigate the fatigue strength of Co-Cr-Mo clasps for removable partial dentures prepared by selective laser melting (SLM). The Co-Cr-Mo alloy specimens for tensile tests (dumbbell specimens) and fatigue tests (clasp specimens) were prepared by SLM with varying angles between the building and longitudina...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.02.032
更新日期:2016-06-01 00:00:00
abstract::The shape memory effect (SME) has long been the focus of interest of many research groups that have studied many facets of it, yet to the authors' knowledge some molecular parameters, such as the molecular weight, have been skipped. Thus, the aim of this work is to offer further insight into the shape memory effect, b...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.04.027
更新日期:2016-08-01 00:00:00
abstract::The mechanical reliability of calcium phosphate cements has restricted their clinical application in load-bearing locations. Although their mechanical strength can be improved using a variety of strategies, their fatigue properties are still unclear, especially after degradation. The evolutions of uniaxial compressive...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.07.026
更新日期:2017-11-01 00:00:00
abstract::Isolated and packed muscles (e.g. in the calf) exhibit different three-dimensional muscle shapes. In packed muscles, cross-sections are more angular compared to the more elliptical ones in isolated muscles. As far as we know, it has not been examined yet, whether the shape of the muscle in its packed condition influen...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.04.006
更新日期:2018-07-01 00:00:00
abstract::In the present work, the releasing heat, scaffold apatite formation, and magnetic behavior of a novel diopside-magnetite nanocomposite with various contents of magnetite (Fe3O4) were evaluated. The N´eel and Brown relaxations did not have a significant effect on the specific absorption rate (SAR) of the composite samp...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.10.015
更新日期:2018-01-01 00:00:00
abstract::The biomechanical behavior of human corneal stroma under uniaxial tension was investigated by the experimental analysis of cornea stromal lenticules taken out by corneal refractive surgery. Uniaxial tests were conducted to determine their stress-strain relationship and tensile strength. The Gasser-Ogden-Holzapfel (GOH...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.05.042
更新日期:2018-09-01 00:00:00