Abstract:
:The biomechanical behavior of human corneal stroma under uniaxial tension was investigated by the experimental analysis of cornea stromal lenticules taken out by corneal refractive surgery. Uniaxial tests were conducted to determine their stress-strain relationship and tensile strength. The Gasser-Ogden-Holzapfel (GOH) model was used to describe biomechanical behavior of the corneal stroma. The theoretical stress-strain relationship of the GOH model in the uniaxial tensile test was deduced. The corneal specimens were collected from ten patients (4 male and 6 female), aged from 17 to 36. The differences between corneal stress-strain relationship in the horizontal and vertical direction were compared. The constitutive parameters C10, k1 and k2 were evaluated through least squares curve-fitting of experimental data.
journal_name
J Mech Behav Biomed Materauthors
Xiang Y,Shen M,Xue C,Wu D,Wang Ydoi
10.1016/j.jmbbm.2018.05.042subject
Has Abstractpub_date
2018-09-01 00:00:00pages
102-108eissn
1751-6161issn
1878-0180pii
S1751-6161(18)30316-3journal_volume
85pub_type
杂志文章abstract:STATEMENT OF PROBLEM:The surface hardness and roughness of different glaze materials for denture base acrylic resins have not been well reported. PURPOSE:The purpose of the study was to measure the surfaces hardness, elastic modulus and surface roughness of 5 different light-polymerized glaze materials for poly methyl...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.103601
更新日期:2020-03-01 00:00:00
abstract::Fibrin and hyaluronic acid are important components of the provisional wound matrix. Through interactions with fibroblasts, they provide biophysical cues that regulate the viscoelastic properties of the extracellular matrix. To understand the roles of fibrin and hyaluronic acid in a collagenous environment, we used fi...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.03.042
更新日期:2018-06-01 00:00:00
abstract::During an underbody blast (UBB) event, mounted occupants are exposed to high rate loading of the spine via the pelvis. The objective of this study was to simulate UBB loading conditions and examine mechanisms of injury in the thoracic, lumbar and sacral spine. Fourteen instrumented, whole-body, postmortem human subjec...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.104271
更新日期:2020-12-24 00:00:00
abstract::With the emergence of new biomaterials and elastography imaging techniques, there is a need for innovative instruments dedicated to viscoelasticity measurements. In this work, we introduce a novel hyper-frequency viscoelastic spectroscopy (HFVS) technique dedicated to characterize soft media subjected to mid-to-very-h...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.03.020
更新日期:2011-10-01 00:00:00
abstract::Ni-free Co-Cr-Mo alloys are some of the most difficult-to-work metallic materials used commonly in biomedical applications. Since the difficulty in plastically deforming them limits their use, an in-depth understanding of their plastic deformability is of crucial importance for both academic and practical purposes. In...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.10.021
更新日期:2015-03-01 00:00:00
abstract::Methods used to evaluate bone mechanical properties vary widely depending on the motivation and environment of individual researchers, clinicians, and industries. Further, the innate complexity of bone makes validation of each method difficult. Thus, the purpose of the present research was to quantify methodological e...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.104253
更新日期:2021-03-01 00:00:00
abstract::The adhesion of bovine chondrocytes and human osteoblasts to three titania-based coatings, formed by plasma electrolytic oxidation (PEO), was compared to that on uncoated Ti-6Al-4V substrates, and some comparisons were also made with plasma sprayed hydroxyapatite (HA) coatings. This was done using a centrifuge, with a...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.07.009
更新日期:2011-11-01 00:00:00
abstract::Fish scales from modern teleost fish are high-performance materials made of cross-plies of collagen type I fibrils reinforced with hydroxyapatite. Recent studies on this material have demonstrated the remarkable performance of this material in tension and against sharp puncture. Although it is known that teleost fish ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2014.09.025
更新日期:2015-12-01 00:00:00
abstract::Experimental investigations for anatomic variation in the magnitude and anisotropy of elastic constants in human femoral cortical bone tissue have typically focused on a limited number of convenient sites near the mid-diaphysis. However, the proximal and distal ends of the diaphysis are more clinically relevant to com...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2008.08.005
更新日期:2009-07-01 00:00:00
abstract::This study aimed at investigating articular cartilage rupture by investigating the response of healthy and degenerate cartilage through altering the osmotic swelling environment of surface-intact, cartilage-on-bone specimens. The osmotic environment in healthy and degenerate bovine cartilage was varied by soaking tiss...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.04.018
更新日期:2011-10-01 00:00:00
abstract::Intervertebral discs (IVDs) maintain flexibility of the spine and bear mechanical load. Annulus fibrosus (AF) defects are associated with IVD degeneration and herniation which disrupt biomechanical function and can cause pain. AF puncture injuries can induce IVD degeneration but are needed to inject therapies. Identif...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.03.024
更新日期:2019-07-01 00:00:00
abstract:OBJECTIVES:The causes of in vivo fractures of all-ceramic dental crowns are not yet fully understood. The fracture origins often occur in the cervical margin in the approximal area, but the reason for this is unclear. The aim of this study was to evaluate the fracture origin of 22 of clinically-failed alumina crowns. ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.08.006
更新日期:2016-01-01 00:00:00
abstract::Previous studies on knee biomechanics have mainly focused on the joint structure itself, largely neglecting the material properties of the muscles and connective tissues around the knee joint. Therefore, this study was purposed to conduct a systematic in vivo examination of the material properties of muscles, tendons,...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.103829
更新日期:2020-09-01 00:00:00
abstract::A discrete network model (DNM) to represent the mechanical behavior of the human amnion is proposed. The amnion is modeled as randomly distributed points interconnected with connector elements representing collagen crosslinks and fiber segments, respectively. This DNM is computationally efficient and allows simulation...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.11.009
更新日期:2016-05-01 00:00:00
abstract::In 3DP fabricating artificial bone scaffolds process, the interaction mechanism between binder and bioceramics power determines the microstructure and macro mechanical properties of Hydroxyapatite (HA) bone scaffold. In this study, we applied Molecular Dynamics (MD) methods to investigating the bonding mechanism and e...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.12.007
更新日期:2016-04-01 00:00:00
abstract:OBJECTIVES:To test whether the load-bearing capacity of occlusal veneers made of ceramic or hybrid materials bonded to dentin does differ from those of porcelain-fused-to metal or lithium disilicate glass ceramic crowns. MATERIAL AND METHODS:In 80 human molars, occlusal tooth substance was removed so that the defects ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.04.006
更新日期:2019-07-01 00:00:00
abstract::The AFM combined nanoindentation was performed to observe the ultrastructure of enamel rod from various section plans and positions while probing their mechanical and tribological properties of the area. The nanohardness and the elastic modulus of the head region of the enamel rods are significantly higher than that o...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2010.12.002
更新日期:2011-05-01 00:00:00
abstract::Severe plastic deformation (SPD) has recently been advanced as the main process for fabricating bulk ultrafine grained or nanocrystalline metallic materials, which present much higher strength and better bio-compatibility than coarse-grained counterparts. Medical devices, such as aneurysm clips and dental implants, re...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.02.002
更新日期:2017-04-01 00:00:00
abstract::This paper presents a strain-based damage model to predict the stress-strain relationship and investigate the damage onset and evolution of the fibre and matrix of a fully bio-resorbable phosphate glass fibre reinforced composite under three-point bending. The flexural properties of the composite are crucial, particul...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.02.022
更新日期:2018-05-01 00:00:00
abstract::Biocompatible polymers are commonly used to fabricate microfluidic channels for the study of biological flows such as blood microflows. The most common of these materials is polydimethylsiloxane (PDMS) which is very hydrophobic. Oxygenated plasma is advocated to treat the PDMS with reported decreases in contact angle ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.07.007
更新日期:2013-01-01 00:00:00
abstract::In the study, CoCrWCu alloys with differing Cu content (2, 3, 4 wt%) were prepared by selective laser melting using mixture powders consisting of CoCrW and Cu, aiming at investigating the effect of Cu on the microstructures, mechanical properties, corrosion behavior and cytotoxicity. The SEM observations indicated tha...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.02.026
更新日期:2018-05-01 00:00:00
abstract::Hydrogels are more and more attractive in biomedical fields, since they can be used as injectable scaffolds, drugs and gene carriers and smart sensors. The highly hydrated hydrogels, however, generally have low mechanical strength. In this work, a composite chitosan hydrogel was prepared by blending water soluble and ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2008.02.001
更新日期:2008-10-01 00:00:00
abstract::The incorporation of functional monomers and proteolytic inhibitors into adhesive systems have shown to be promising strategies to improve the longevity of adhesive restorations. The aim of this study was to evaluate the long-term bonding performance and anti-gelatinolytic effect of a 10-MDP-based universal adhesive s...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.103925
更新日期:2020-10-01 00:00:00
abstract::Numerical studies of the intervertebral disc (IVD) are important to better understand the load transfer and the mechanobiological processes within the disc. Among the relevant calculations, fluid-related outputs are critical to describe and explore accurately the tissue properties. Porohyperelastic finite element mode...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.05.012
更新日期:2013-10-01 00:00:00
abstract::Uniaxial tensile tests were performed to investigate the mechanical properties of the ultra-high molecular weight polyethylene (UHMWPE) with different modification conditions. It was found that the different modification conditions have great influence on the mechanical properties of the UHMWPE. Subsequently, the unia...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.08.022
更新日期:2018-12-01 00:00:00
abstract::This paper presents a numerical study on using vibration analysis to detect degradation in degrading polyesters. A numerical model of a degrading plate sample is considered. The plate is assumed to degrade following the typical behaviour of amorphous copolymers of polylactide and polyglycolide. Due to the well-known a...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.05.002
更新日期:2016-09-01 00:00:00
abstract::This study compared the fatigue performance and the stress distribution of endodontically treated molars restored with endocrowns obtained with lithium disilicate glass-ceramic or a polymer-infiltrated ceramic network, both processed by CAD-CAM, and direct composite restorations. Forty-eight human mandibular molars we...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.103401
更新日期:2019-12-01 00:00:00
abstract::Continuous fibre distribution models can be applied to a variety of biological tissues with both charged and neutral extracellular matrices. In particular, ellipsoidal models have been used to describe the complex material behaviour of tissues such as articular cartilage and their engineered tissue equivalents. The ch...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.01.006
更新日期:2012-05-01 00:00:00
abstract::The Zn-based alloys, alloyed with the elements of the 2nd group of the periodic table, are considered as potential biodegradable materials suitable for the fabrication of small orthopaedic implants or cardiovascular stents. Unfortunately, the as-cast Zn-based alloys do not fulfil the requirements for mechanical proper...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.103796
更新日期:2020-08-01 00:00:00
abstract::Characterization of the mechanical properties of biological materials is often complicated by small volume, irregular geometry, fragility, and environmental sensitivity. Pipette aspiration and nanoindentation testing deal well with these limitations and have seen increasing use in biomaterial characterization, but lit...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.07.022
更新日期:2015-11-01 00:00:00