Comparison of endocrowns made of lithium disilicate glass-ceramic or polymer-infiltrated ceramic networks and direct composite resin restorations: fatigue performance and stress distribution.

Abstract:

:This study compared the fatigue performance and the stress distribution of endodontically treated molars restored with endocrowns obtained with lithium disilicate glass-ceramic or a polymer-infiltrated ceramic network, both processed by CAD-CAM, and direct composite restorations. Forty-eight human mandibular molars were randomly assigned into 03 groups (n = 16) and restored with endocrowns (LD - lithium disilicate glass-ceramic or PICN - polymer-infiltrated ceramic network) or with direct composite restorations. Fatigue testing followed a step-stress approach (initial maximum load of 200 N and 5000 cycles, incremental step load of 200N and 10,000 cycles/step, being the specimens loaded until failure or to a maximum of 135,000 cycles at 2800 N). The fatigue failure load and number of cycles until failure were recorded and statistically analyzed. Fractographic and finite element (FEA) analyzes were conducted as well. There were no differences in fatigue failure load, number of cycles until fracture and mean survival probabilities among groups. However, indirect endocrowns had higher mechanical structural reliability, and LD restorations lasted more time before start to failing. FEA showed that the stress concentration in tooth tissues was higher for the resin composite, followed by PICN and LD in a decreasing order. Almost all fractures were restricted to the restorative material (without tooth involvement), and origins were identified at occlusal surface. The type of restoration did not influence the fatigue failure load, number of cycles until fracture and mean survival probabilities of the restorative strategies. Despite that, the mechanical structural reliability of endocrowns, especially those made of lithium disilicate, was higher and lasted more time before start to failing.

authors

Dartora G,Rocha Pereira GK,Varella de Carvalho R,Zucuni CP,Valandro LF,Cesar PF,Caldas RA,Bacchi A

doi

10.1016/j.jmbbm.2019.103401

subject

Has Abstract

pub_date

2019-12-01 00:00:00

pages

103401

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(19)30995-6

journal_volume

100

pub_type

杂志文章
  • Nanoscopic dynamic mechanical properties of intertubular and peritubular dentin.

    abstract::An experimental evaluation of intertubular and peritubular dentin was performed using nanoindentation and Dynamic Mechanical Analysis (DMA). The objective of the investigation was to evaluate the differences in dynamic mechanical behavior of these two constituents and to assess whether their response is frequency depe...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.08.010

    authors: Ryou H,Romberg E,Pashley DH,Tay FR,Arola D

    更新日期:2012-03-01 00:00:00

  • Effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading.

    abstract::This study evaluated the effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading. Disc-shaped zirconia specimens (Ø: 15mm, thickness: 1.2mm) (N=32) were submitted to one of the air-particle abrasion protocols (n=8 per...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.01.005

    authors: Ozcan M,Melo RM,Souza RO,Machado JP,Felipe Valandro L,Botttino MA

    更新日期:2013-04-01 00:00:00

  • Mechanical, bactericidal and osteogenic behaviours of hydrothermally synthesised TiO2 nanowire arrays.

    abstract::The application of orthopaedic implants is associated with risks of bacterial infection and long-term antibiotic therapy. This problem has led to the study of implants with nano-textured surfaces as a method of inhibiting bacterial adhesion and reducing implant failure due to infection. In this research, various nano-...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.02.011

    authors: Jaggessar A,Mathew A,Wang H,Tesfamichael T,Yan C,Yarlagadda PK

    更新日期:2018-04-01 00:00:00

  • The effect of Equal Channel Angular Pressing on the stress corrosion cracking susceptibility of AZ31 alloy in simulated body fluid.

    abstract::Despite the great potential of Mg and its alloys as material for biodegradable implants, their low resistance to the simultaneous action of corrosion and mechanical stresses in the human body have hampered their use. Stress Corrosion Cracking has been reported as one of the most critical failure modes to overcome to a...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103724

    authors: Peron M,Skaret PC,Fabrizi A,Varone A,Montanari R,Roven HJ,Ferro P,Berto F,Torgersen J

    更新日期:2020-06-01 00:00:00

  • Increased stiffness of collagen fibrils following cyclic tensile loading.

    abstract::Alterations in mechanical loading can induce growth and remodeling in soft connective tissues. Numerous studies have measured changes in the collagen structure and mechanical properties of cellularized native and engineered tissues in response to cyclic mechanical loading. However, a recent experimental study demonstr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.03.027

    authors: Chen ML,Ruberti JW,Nguyen TD

    更新日期:2018-06-01 00:00:00

  • Alternative processing methods of hybrid porous scaffolds based on gelatin and chitosan.

    abstract::The present work focuses on the development of scaffolds based on gelatin and chitosan using different protocols based on the general processing of phase separation, derived from the fabrication of hydrogels and freeze-drying. The scaffolds were produced with 1 wt% of two different biopolymers, i.e. gelatin (GE) and c...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103472

    authors: Perez-Puyana V,Rubio-Valle JF,Jiménez-Rosado M,Guerrero A,Romero A

    更新日期:2020-02-01 00:00:00

  • Mechano-rheological properties of the murine thrombus determined via nanoindentation and finite element modeling.

    abstract::Deep vein thrombosis, pulmonary embolism, and abdominal aortic aneurysms are blood-related diseases that represent a major public health problem. These diseases are characterized by the formation of a thrombus (i.e., blood clot) that either blocks a major artery or causes an aortic rupture. Identifying the mechanical ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.02.012

    authors: Slaboch CL,Alber MS,Rosen ED,Ovaert TC

    更新日期:2012-06-01 00:00:00

  • Evaluation of experimental, analytical, and computational methods to determine long-bone bending stiffness.

    abstract::Methods used to evaluate bone mechanical properties vary widely depending on the motivation and environment of individual researchers, clinicians, and industries. Further, the innate complexity of bone makes validation of each method difficult. Thus, the purpose of the present research was to quantify methodological e...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104253

    authors: Collins CJ,Yang B,Crenshaw TD,Ploeg HL

    更新日期:2021-03-01 00:00:00

  • Effect of Cu on microstructure, mechanical properties, corrosion resistance and cytotoxicity of CoCrW alloy fabricated by selective laser melting.

    abstract::In the study, CoCrWCu alloys with differing Cu content (2, 3, 4 wt%) were prepared by selective laser melting using mixture powders consisting of CoCrW and Cu, aiming at investigating the effect of Cu on the microstructures, mechanical properties, corrosion behavior and cytotoxicity. The SEM observations indicated tha...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.02.026

    authors: Lu Y,Ren L,Xu X,Yang Y,Wu S,Luo J,Yang M,Liu L,Zhuang D,Yang K,Lin J

    更新日期:2018-05-01 00:00:00

  • Periprosthetic wear particle migration and distribution modelling and the implication for osteolysis in cementless total hip replacement.

    abstract::In total hip replacement (THR), wear particles play a significant role in osteolysis and have been observed in locations as remote as the tip of femoral stem. However, there is no clear understanding of the factors and mechanisms causing, or contributing to particle migration to the periprosthetic tissue. Interfacial ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.01.005

    authors: Alidousti H,Taylor M,Bressloff NW

    更新日期:2014-04-01 00:00:00

  • Finite Element simulation of buckling-induced vein tortuosity and influence of the wall constitutive properties.

    abstract::The mechanisms giving rise to vein tortuosity, which is often associated with varicosis, are poorly understood. Recent works suggest that significant biological changes in the wall of varicose veins may precede the mechanical aspects of the disease. To test the hypothesis of tortuosity being a consequence of these cha...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.05.006

    authors: Badel P,Rohan CP,Avril S

    更新日期:2013-10-01 00:00:00

  • Looped ends versus open ends braided stent: A comparison of the mechanical behaviour using analytical and numerical methods.

    abstract::The present study has two major purposes: firstly, to investigate whether the analytical model proposed by Jedwab and Clerc for assessing the mechanical behaviour of an open ends metallic braided stent is applicable to the looped ends stent design and secondly, to compare the response of the two stent designs subjecte...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.025

    authors: Shanahan C,Tiernan P,Tofail SAM

    更新日期:2017-11-01 00:00:00

  • Two-piece zirconia oral implants withstand masticatory loads: An investigation in the artificial mouth.

    abstract:OBJECTIVE:To evaluate the fracture resistance of two-piece zirconia oral implants after long-term thermomechanical cycling in an aqueous environment. Non-loaded samples and a one-piece implant system served as control groups. METHODS:A total of 48 zirconia implants were evaluated: 16 one-piece implants (ATZ; Group A) ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.07.005

    authors: Spies BC,Nold J,Vach K,Kohal RJ

    更新日期:2016-01-01 00:00:00

  • Mechanical properties of bovine cortical bone based on the automated ball indentation technique and graphics processing method.

    abstract::Cortical bone provides the main form of support in humans and other vertebrates against various forces. Thus, capturing its mechanical properties is important. In this study, the mechanical properties of cortical bone were investigated by using automated ball indentation and graphics processing at both the macroscopic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.039

    authors: Zhang A,Zhang S,Bian C

    更新日期:2018-02-01 00:00:00

  • Electromyography activity of triceps surae and tibialis anterior muscles related to various sports shoes.

    abstract::Triceps surae (TS) and tibialis anterior (TA) activation patterns have not yet been studied under different types of sport shoes. We hypothesized that sports shoes may reduce the activity patterns of these muscles in relation to barefoot condition. Thus, our main aim was to evaluate the activity patterns of TS and TA ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.05.039

    authors: Roca-Dols A,Elena Losa-Iglesias M,Sánchez-Gómez R,Becerro-de-Bengoa-Vallejo R,López-López D,Palomo-López P,Rodríguez-Sanz D,Calvo-Lobo C

    更新日期:2018-10-01 00:00:00

  • Comparison of splinted and non-splinted superstructures of three implants placed in a mandibular distal extension model with missing teeth using modal analysis.

    abstract::This study evaluated the effects of two types of superstructures (splinted crown and non-splinted crown) on four vibration characteristics (natural frequency, damping ratio (DAR), vectors in antiphase, maximum displacement (MDP)) by using modal analysis. These structures were fabricated on three implants placed in the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104050

    authors: Sasaki T,Nakata H,Suzuki A,Hada T,Kasugai S,Kuroda S

    更新日期:2020-12-01 00:00:00

  • Study of indentation of a sample equine bone using finite element simulation and single cycle reference point indentation.

    abstract::In an attempt to study the mechanical behavior of bone under indentation, methods of analyses and experimental validations have been developed, with a selected test material. The test material chosen is from an equine cortical bone. Stress-strain relationships are first obtained from conventional mechanical property t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.11.020

    authors: Hoffseth K,Randall C,Hansma P,Yang HT

    更新日期:2015-02-01 00:00:00

  • A discrete network model to represent the deformation behavior of human amnion.

    abstract::A discrete network model (DNM) to represent the mechanical behavior of the human amnion is proposed. The amnion is modeled as randomly distributed points interconnected with connector elements representing collagen crosslinks and fiber segments, respectively. This DNM is computationally efficient and allows simulation...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.11.009

    authors: Mauri A,Hopf R,Ehret AE,Picu CR,Mazza E

    更新日期:2016-05-01 00:00:00

  • Fracture mechanics of hydroxyapatite single crystals under geometric confinement.

    abstract::Geometric confinement to the nanoscale, a concept that refers to the characteristic dimensions of structural features of materials at this length scale, has been shown to control the mechanical behavior of many biological materials or their building blocks, and such effects have also been suggested to play a crucial r...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.12.005

    authors: Libonati F,Nair AK,Vergani L,Buehler MJ

    更新日期:2013-04-01 00:00:00

  • Mechanical characterization of bio composite films as a novel drug carrier platform for sustained release of 5-fluorouracil for colon cancer: Methodological investigation.

    abstract::In this study, we employed Pectin (PC) as a matrix that is hybridized with three different nucleobase (NB) units (cytosine, thymine, uracil) to generate pectin-nucleobase(PC-NB) biocomposite films stabilized through bio-multiple hydrogen bonds (BMHBs) as drug carrier for anticancer 5-Fluorouracil (5-FU). Prepared bioc...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104266

    authors: Tamilselvi S,Kavitha R,Usharani M,Mumjitha M,Mohanapriya S,MohanaPriya S

    更新日期:2021-03-01 00:00:00

  • Statistics in experimental studies on the human spine: Theoretical basics and review of applications.

    abstract::Proper statistical analysis is essential in the research studies. In particular, as regards the in vitro testing of the lumbar spine, the criteria for the standardization have been extensively discussed but the use of statistics has not been reviewed. Unfortunately, cadaveric testing is a very difficult and complex ex...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103862

    authors: Bassani T,Galbusera F

    更新日期:2020-10-01 00:00:00

  • Mechanical response of human abdominal walls ex vivo: Effect of an incisional hernia and a mesh repair.

    abstract::The design of meshes for the treatment of incisional hernias could benefit from better knowledge of the mechanical response of the abdominal wall and how this response is affected by the implant. The aim of this study was to characterise the mechanical behaviour of the human abdominal wall. Abdominal walls were tested...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.002

    authors: Podwojewski F,Otténio M,Beillas P,Guérin G,Turquier F,Mitton D

    更新日期:2014-10-01 00:00:00

  • Influence of the fabrication process and fluoride content on the tribocorrosion behaviour of Ti6Al4V biomedical alloy in artificial saliva.

    abstract::Titanium and its alloys are widely used as dental implants due to their low density, excellent biocompatibility, mechanical properties and corrosion resistance. However, during their lifetime Ti6Al4V biomedical alloys are subjected to different mechanical actions (i.e., sliding or fretting), thus resulting in a triboc...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.01.019

    authors: Licausi MP,Igual Muñoz A,Amigó Borrás V

    更新日期:2013-04-01 00:00:00

  • Fatigue properties of removable partial denture clasps fabricated by selective laser melting followed by heat treatment.

    abstract::The aim of the study was to investigate the effect of post-heat treatment on the microstructures and fatigue strengths of Co-Cr-Mo (CCM) clasps prepared by selective laser melting (SLM). Clasp specimens and rod-shaped specimens were fabricated by SLM using CCM powders with different angulations (0°, 45°, and 90°). Two...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.06.010

    authors: Kittikundecha N,Kajima Y,Takaichi A,Wai Cho HH,Htat HL,Doi H,Takahashi H,Hanawa T,Wakabayashi N

    更新日期:2019-10-01 00:00:00

  • Effect of size and dimensional tolerance of reverse total shoulder arthroplasty on wear: An in-silico study.

    abstract::Although huge research efforts have been devoted to wear analysis of ultra-high molecular weight polyethylene (UHMWPE) in hip and knee implants, shoulder prostheses have been studied only marginally. Recently, the authors presented a numerical wear model of reverse total shoulder arthroplasties (RTSAs), and its applic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.033

    authors: Mattei L,Di Puccio F,Joyce TJ,Ciulli E

    更新日期:2016-08-01 00:00:00

  • Development of novel zirconia implant's materials gradated design with improved bioactive surface.

    abstract::Zirconia implants are becoming a preference choice for different applications such as knee, dental, among others. In order to improve osseointegration, implant's surfaces are usually coated with bioactive materials like hydroxyapatite (HAp) and beta-tricalcium phosphate (β-TCP) that are very similar to the calcium pho...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.02.022

    authors: Faria D,Pires JM,Boccaccini AR,Carvalho O,Silva FS,Mesquita-Guimarães J

    更新日期:2019-06-01 00:00:00

  • A low-shrinkage dental composite with epoxy-polyhedral oligomeric silsesquioxane.

    abstract::Polymerization shrinkage and mechanical properties affect the service life of dental restorative composites. Polyhedral oligomeric silsesquioxanes (POSS) can be an efficient strategy to improve the shrinkage properties and mechanical properties simultaneously. In this work, epoxycyclohexyl POSS (E-POSS) was used to mo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103515

    authors: Li Z,Zhang H,Xiong G,Zhang J,Guo R,Li L,Zhou H,Chen G,Zhou Z,Li Q

    更新日期:2020-03-01 00:00:00

  • An interface finite element model can be used to predict healing outcome of bone fractures.

    abstract::After fractures, bone can experience different potential outcomes: successful bone consolidation, non-union and bone failure. Although, there are a lot of factors that influence fracture healing, experimental studies have shown that the interfragmentary movement (IFM) is one of the main regulators for the course of bo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.09.023

    authors: Alierta JA,Pérez MA,García-Aznar JM

    更新日期:2014-01-01 00:00:00

  • Adaptive responses of murine osteoblasts subjected to coupled mechanical stimuli.

    abstract::Restitution of the natural organization and orientation of cells is imperative for the construction of functional tissue scaffolds. While numerous studies have exploited mechanical methods to engineer tissues with the desired cellular architecture, fundamental knowledge is still lacking in understanding the manner in ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.09.018

    authors: Serrano JC,Cora-Cruz J,Diffoot-Carlo N,Sundaram PA

    更新日期:2018-01-01 00:00:00

  • Single and reciprocal friction testing of micropatterned surfaces for orthopedic device design.

    abstract::The use of micropatterning to create uniform surface morphologies has been cited as yielding improvements in the coefficient of friction during high velocity sliding contact. Studies have not been preformed to determine if these micropatterns could also be useful in biomedical applications, such as total joint replace...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.08.022

    authors: Mitchell N,Eljach C,Lodge B,Sharp JL,Desjardins JD,Kennedy MS

    更新日期:2012-03-01 00:00:00