Effect of Cu on microstructure, mechanical properties, corrosion resistance and cytotoxicity of CoCrW alloy fabricated by selective laser melting.

Abstract:

:In the study, CoCrWCu alloys with differing Cu content (2, 3, 4 wt%) were prepared by selective laser melting using mixture powders consisting of CoCrW and Cu, aiming at investigating the effect of Cu on the microstructures, mechanical properties, corrosion behavior and cytotoxicity. The SEM observations indicated that the Cu content up to 3 wt% caused the Si-rich precipitates to segregate along grain boundaries and in the grains, and EBSD analysis suggested that the Cu addition decreased the recrystallization degree and increased the grain diameter and fraction of big grains. The tensile tests found that the increasing Cu content led to a decrease of mechanical properties compared with Cu-free CoCrW alloy. The electrochemical tests revealed that the addition of Cu shifted the corrosion potential toward nobler positive, but increased the corrosion current density. Also, a more protective passive film was formed when 2 wt% Cu content was added, but the higher Cu content up to 3 wt% was detrimental to the corrosion resistance. It was noted that there was no cytotoxicity for Cu-bearing CoCrW alloys to MG-63 cell and the cells could spread well on the surfaces of studied alloys. Meanwhile, the Cu-bearing CoCrW alloy exhibited an excellent antibacterial performance against E.coli when Cu content was up to 3 wt%. It is suggested that the feasible fabrication of Cu-bearing CoCrW alloy by SLM using mixed CoCrW and Cu powders is a promising candidate for use in antibacterial oral repair products. This current study also can aid in the further design of antibacterial Cu-containing CoCrW alloying powders.

authors

Lu Y,Ren L,Xu X,Yang Y,Wu S,Luo J,Yang M,Liu L,Zhuang D,Yang K,Lin J

doi

10.1016/j.jmbbm.2018.02.026

subject

Has Abstract

pub_date

2018-05-01 00:00:00

pages

130-141

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(18)30184-X

journal_volume

81

pub_type

杂志文章
  • Load-bearing in cortical bone microstructure: Selective stiffening and heterogeneous strain distribution at the lamellar level.

    abstract::An improved understanding of bone mechanics is vital in the development of evaluation strategies for patients at risk of bone fracture. The current evaluation approach based on bone mineral density (BMD) measurements lacks sensitivity, and it has become clear that as well as bone mass, bone quality should also be eval...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.08.016

    authors: Katsamenis OL,Chong HM,Andriotis OG,Thurner PJ

    更新日期:2013-01-01 00:00:00

  • Poroviscoelastic characterization of particle-reinforced gelatin gels using indentation and homogenization.

    abstract::Hydrogels are promising materials for bioengineering applications, and are good model materials for the study of hydrated biological tissues. As these materials often have a structural function, the measurement of their mechanical properties is of fundamental importance. In the present study gelatin gels reinforced wi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.01.009

    authors: Galli M,Fornasiere E,Cugnoni J,Oyen ML

    更新日期:2011-05-01 00:00:00

  • Tribology and hydrophobicity of a biocompatible GPTMS/PFPE coating on Ti6Al4V surfaces.

    abstract::Tribological properties of perfluoropolyether (PFPE) coated 3-glycidoxypropyltrimethoxy silane (GPTMS) SAMs (self-assembled monolayers) onto Ti6Al4V alloy substrate were studied using ball-on-disk experiments. GPTMS SAMs deposition onto a Ti6Al4V alloy surface was carried out using solution phase method. Ultra-thin la...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.06.016

    authors: Panjwani B,Sinha SK

    更新日期:2012-11-01 00:00:00

  • An experimental canine patent ductus arteriosus occlusion device based on shape memory polymer foam in a nitinol cage.

    abstract::Patent ductus arteriosus (PDA) is a congenital cardiovascular defect in which a fetal connection between the aorta and pulmonary artery does not spontaneously close shortly after birth. If left uncorrected serious complications and even death can occur. Surgical ligation is the traditional treatment method; however, i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.033

    authors: Wierzbicki MA,Raines SB,Gordon SG,Criscione JC,Saunders AB,Birch S,Due B,Keller B,Nash LD,Miller MW,Maitland DJ

    更新日期:2017-11-01 00:00:00

  • Study of indentation of a sample equine bone using finite element simulation and single cycle reference point indentation.

    abstract::In an attempt to study the mechanical behavior of bone under indentation, methods of analyses and experimental validations have been developed, with a selected test material. The test material chosen is from an equine cortical bone. Stress-strain relationships are first obtained from conventional mechanical property t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.11.020

    authors: Hoffseth K,Randall C,Hansma P,Yang HT

    更新日期:2015-02-01 00:00:00

  • Biomechanical evaluation of laser-etched Ti implant surfaces vs. chemically modified SLA Ti implant surfaces: Removal torque and resonance frequency analysis in rabbit tibias.

    abstract:PURPOSE:To compare osseointegration and implant stability of two types of laser-etched (LE) Ti implants with a chemically-modified, sandblasted, large-grit and acid-etched (SLA) Ti implant (SLActive(®), Straumann, Basel, Switzerland), by evaluating removal torque and resonance frequency between the implant surface and ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.034

    authors: Lee JT,Cho SA

    更新日期:2016-08-01 00:00:00

  • The nonlinear flexural response of a whole teleost fish: Contribution of scales and skin.

    abstract::The scaled skin of fish is an intricate system that provides mechanical protection against hard and sharp puncture, while maintaining the high flexural compliance required for unhindered locomotion. This unusual combination of local hardness and global compliance makes fish skin an interesting model for bioinspired pr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.06.014

    authors: Szewciw L,Zhu D,Barthelat F

    更新日期:2017-12-01 00:00:00

  • Interfascicular matrix-mediated transverse deformation and sliding of discontinuous tendon subcomponents control the viscoelasticity and failure of tendons.

    abstract::In the present article, we investigated the sliding of discontinuous tendon subcomponents and the variation of nonhomogeneous deformation in the human Achilles tendon (AT) over time using uniaxial tensile and relaxation tests. The deformation and the resulting strain distribution under uniaxial tension are examined us...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.027

    authors: Obuchowicz R,Ekiert M,Kohut P,Holak K,Ambrozinski L,Tomaszewski KA,Uhl T,Mlyniec A

    更新日期:2019-09-01 00:00:00

  • Looped ends versus open ends braided stent: A comparison of the mechanical behaviour using analytical and numerical methods.

    abstract::The present study has two major purposes: firstly, to investigate whether the analytical model proposed by Jedwab and Clerc for assessing the mechanical behaviour of an open ends metallic braided stent is applicable to the looped ends stent design and secondly, to compare the response of the two stent designs subjecte...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.025

    authors: Shanahan C,Tiernan P,Tofail SAM

    更新日期:2017-11-01 00:00:00

  • Prevention of intestinal adhesion and regeneration of abdominal wall tissue with meshes containing an electrostatically spun acellular dermal matrix (ADM)/silk fibroin (SF) fiber composite polypropylene mesh.

    abstract::The repair of abdominal wall defects often requires the use of polypropylene (PP) as the main material. After a PP mesh is implanted in the body, contact with the intestine can cause adhesions between the intestine and the mesh, leading to serious complications such as intestinal fistula. In this study, we used electr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104087

    authors: Yang D,Song Z,Lin Y,Dong W,Fu S,Yang J,Zhang P,Gu Y

    更新日期:2020-12-01 00:00:00

  • Cytocompatibility, mechanical and dissolution properties of high strength boron and iron oxide phosphate glass fibre reinforced bioresorbable composites.

    abstract::In this study, Polylactic acid (PLA)/phosphate glass fibres (PGF) composites were prepared by compression moulding. Fibres produced from phosphate based glasses P2O5-CaO-MgO-Na2O (P45B0), P2O5-CaO-MgO-Na2O-B2O3 (P45B5), P2O5-CaO-MgO-Na2O-Fe2O3 (P45Fe3) and P2O5-CaO-MgO-Na2O-B2O3-Fe2O3 (P45B5Fe3) were used to reinforce...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.011

    authors: Sharmin N,Hasan MS,Parsons AJ,Rudd CD,Ahmed I

    更新日期:2016-06-01 00:00:00

  • Is short term intraoperative application of disinfectants harmful to breast implants in breast reconstruction? An experimental study and literature survey.

    abstract:OBJECTIVES:Bacterial contamination of breast implants and biofilm formation has been discussed as a major reason for implant loss and capsular contraction. Intra- and perioperative treatment of breast implants with disinfectants to prevent bacterial contamination has been frequently reported. Given the increasing aware...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.10.021

    authors: Schmitz M,Schubert DW,Kaschta J,Daenicke J,Walter BL,Horch RE

    更新日期:2019-02-01 00:00:00

  • Computational micromechanics of bioabsorbable magnesium stents.

    abstract::Magnesium alloys are a promising candidate material for an emerging generation of absorbable metal stents. Due to its hexagonal-close-packed lattice structure and tendency to undergo twinning, the deformation behaviour of magnesium is quite different to that of conventional stent materials, such as stainless steel 316...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.01.007

    authors: Grogan JA,Leen SB,McHugh PE

    更新日期:2014-06-01 00:00:00

  • An experimental analysis of shell failure in breast implants.

    abstract::Breast implant durability and the mechanisms of rupture are important topics in the medical community, for patients, manufactures and regulatory medical agencies. After concerns about the Poly Implant Prosthesis (PIP) implants, the need for understanding the adverse outcomes and the failure mode to improve the breast ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.04.005

    authors: Ramião NG,Martins PS,Barroso ML,Santos DC,Fernandes AA

    更新日期:2017-08-01 00:00:00

  • Tribological behavior of Ti-6Al-4V against cortical bone in different biolubricants.

    abstract::Titanium alloys (Ti-6Al-4V) are promising materials as bone implants in clinical surgeries owing to their excellent performances. However, wear debris caused by the tribological behavior of the cortical bone and titanium alloy interface were found to be paramount for implant stability. The contact environment between ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.10.031

    authors: Wang C,Zhang G,Li Z,Zeng X,Xu Y,Zhao S,Hu H,Zhang Y,Ren T

    更新日期:2019-02-01 00:00:00

  • Effect of solid distribution on elastic properties of open-cell cellular solids using numerical and experimental methods.

    abstract::Effect of solid distribution between edges and vertices of three-dimensional cellular solid with an open-cell structure was investigated both numerically and experimentally. Finite element analysis (FEA) with continuum elements and appropriate periodic boundary condition was employed to calculate the elastic propertie...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.05.018

    authors: Zargarian A,Esfahanian M,Kadkhodapour J,Ziaei-Rad S

    更新日期:2014-09-01 00:00:00

  • Profile of a 10-MDP-based universal adhesive system associated with chlorhexidine: Dentin bond strength and in situ zymography performance.

    abstract::The incorporation of functional monomers and proteolytic inhibitors into adhesive systems have shown to be promising strategies to improve the longevity of adhesive restorations. The aim of this study was to evaluate the long-term bonding performance and anti-gelatinolytic effect of a 10-MDP-based universal adhesive s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103925

    authors: Giacomini MC,Scaffa PMC,Gonçalves RS,Zabeu GS,Vidal CMP,Carrilho MRO,Honório HM,Wang L

    更新日期:2020-10-01 00:00:00

  • Effect of immediate dentine sealing on the fracture strength of lithium disilicate and multiphase resin composite inlay restorations.

    abstract:PURPOSE:Limited information is available on the effect of Immediate Dentin Sealing (IDS) on the fracture strength of indirect partial posterior restorations. This study evaluated the effect of IDS on the fracture strength and failure types of two indirect restorative materials. MATERIALS AND METHODS:Standard MOD inlay...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.04.002

    authors: van den Breemer CRG,Özcan M,Cune MS,van der Giezen R,Kerdijk W,Gresnigt MMM

    更新日期:2017-08-01 00:00:00

  • Influence of Si addition on the microstructure and mechanical properties of Ti-35Nb alloy for applications in orthopedic implants.

    abstract::In the development of new materials for orthopedic implants, special attention has been given to Ti alloys that show biocompatible alloy elements and that are capable of reducing the elastic modulus. Accordingly, Ti-Nb-Si alloys show great potential for application. Thus, this is a study on the microstructures and pro...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.06.035

    authors: Tavares AM,Ramos WS,de Blas JC,Lopes ES,Caram R,Batista WW,Souza SA

    更新日期:2015-11-01 00:00:00

  • UV damage and sun care: deciphering mechanics of skin to develop next generation therapies.

    abstract::Some ultraviolet radiation (UV) is essential to the body as it stimulates the production of vitamin D, yet overexposure has deleterious consequences for the skin. UV induces structural and cellular changes across the different layers of skin tissue leading to mechanical and oxidative stress. Both are critical paramete...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.02.008

    authors: Levi K

    更新日期:2013-12-01 00:00:00

  • Sensing inhomogeneous mechanical properties of human corneal Descemet's membrane with AFM nano-indentation.

    abstract::The paper describes a highly space-resolved characterization of the surface mechanical properties of the posterior human corneal layer (Descemet's membrane). This has been accomplished with Atomic Force Microscopy (AFM) nano-indentation by using a probe with a sharp tip geometry. Results indicate that the contact with...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.05.019

    authors: Di Mundo R,Recchia G,Parekh M,Ruzza A,Ferrari S,Carbone G

    更新日期:2017-10-01 00:00:00

  • Measurement of the shear modulus in thin-layered tissues using numerical simulations and shear wave elastography.

    abstract::Measurement of mechanical properties of thin-layered tissues has broad applications in the diagnosis of several pathologies. Ultrasound shear wave elastography (SWE) measures the shear wave speed as a means of estimating the mechanical properties of tissues. However, the wave speed in thin-layered tissues is affected ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103502

    authors: Sadeghi S,Cortes DH

    更新日期:2020-02-01 00:00:00

  • Biomechanical test protocols to detect minor injury effects in intervertebral discs.

    abstract::Intervertebral discs (IVDs) maintain flexibility of the spine and bear mechanical load. Annulus fibrosus (AF) defects are associated with IVD degeneration and herniation which disrupt biomechanical function and can cause pain. AF puncture injuries can induce IVD degeneration but are needed to inject therapies. Identif...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.024

    authors: Torre OM,Evashwick-Rogler TW,Nasser P,Iatridis JC

    更新日期:2019-07-01 00:00:00

  • Mechanical performance, corrosion and tribological evaluation of a Co-Cr-Mo alloy processed by MIM for biomedical applications.

    abstract::In this study, the processing parameters mechanical performance, corrosion and tribological evaluation of a low carbon content Co-Cr-Mo alloy are discussed. The production of parts using the Metal Injection Moulding (MIM) process is optimized, specifically concerning the rheological analysis of the prepared feedstocks...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103706

    authors: Herranz G,Berges C,Naranjo JA,García C,Garrido I

    更新日期:2020-05-01 00:00:00

  • Characterization of the mechanical behaviors and bioactivity of tetrapod ZnO whiskers reinforced bioactive glass/gelatin composite scaffolds.

    abstract::The purpose of this study is to construct bone tissue engineering scaffold with high porosity, good mechanical properties, and biological activities. Bioactive glass/gelatin composite scaffolds with different amounts of tetrapod zinc oxide whiskers were produced. The morphology, mechanical properties and in vitro bioa...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.01.032

    authors: Guo W,Zhao F,Wang Y,Tang J,Chen X

    更新日期:2017-04-01 00:00:00

  • Preparation of low shrinkage methacrylate-based resin system without Bisphenol A structure by using a synthesized dendritic macromer (G-IEMA).

    abstract::With the growing attention on estrogenic effect of Bisphenol A (BPA), the application of BPA derivatives like Bis-GMA in dental materials has also been doubted. In this research, new BPA free dental resin systems were prepared with synthesized dendritic macromer G-IEMA, UDMA, and TEGDMA. Physicochemical properties, su...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.03.012

    authors: Yu B,Liu F,He J

    更新日期:2014-07-01 00:00:00

  • Thermal-stress analysis of ceramic laminate veneer restorations with different incisal preparations using micro-computed tomography-based 3D finite element models.

    abstract::Main objective of this study is to investigate the thermal behavior of ceramic laminate veneer restorations of the maxillary central incisor with different incisal preparations such as butt joint and palatinal chamfer using finite element method. In addition, it is also aimed to understand the effect of different ther...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.039

    authors: Celebi AT,Icer E,Eren MM,Baykasoglu C,Mugan A,Yildiz E

    更新日期:2017-11-01 00:00:00

  • Load-bearing capacities of ultra-thin occlusal veneers bonded to dentin.

    abstract:OBJECTIVES:To test whether the load-bearing capacity of occlusal veneers made of ceramic or hybrid materials bonded to dentin does differ from those of porcelain-fused-to metal or lithium disilicate glass ceramic crowns. MATERIAL AND METHODS:In 80 human molars, occlusal tooth substance was removed so that the defects ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.04.006

    authors: Maeder M,Pasic P,Ender A,Özcan M,Benic GI,Ioannidis A

    更新日期:2019-07-01 00:00:00

  • Elastic softening of β-type Ti-Nb alloys by indium (In) additions.

    abstract::Recent developments showed that β-type Ti-Nb alloys are good candidates for hard tissue replacement and repair. However, their elastic moduli are still to be further reduced to match Young׳s modulus values of human bone, in order to avoid stress shielding. In the present study, the effect of indium (In) additions on t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.010

    authors: Calin M,Helth A,Gutierrez Moreno JJ,Bönisch M,Brackmann V,Giebeler L,Gemming T,Lekka CE,Gebert A,Schnettler R,Eckert J

    更新日期:2014-11-01 00:00:00

  • Reinforcing effect of graphene oxide reinforcement on the properties of poly (vinyl alcohol) and carboxymethyl tamarind gum based phase-separated film.

    abstract::The current study deals with the preparation and the characterization of the PVA-CMT-GO films. The PVA-CMT film was translucent in nature and smooth to touch. The addition of GO resulted in the formation of agglomerated structures. XRD studies suggested that the incorporation of GO increased the average crystallite si...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.02.021

    authors: Yadav I,Nayak SK,Rathnam VSS,Banerjee I,Ray SS,Anis A,Pal K

    更新日期:2018-05-01 00:00:00