Effect of immediate dentine sealing on the fracture strength of lithium disilicate and multiphase resin composite inlay restorations.

Abstract:

PURPOSE:Limited information is available on the effect of Immediate Dentin Sealing (IDS) on the fracture strength of indirect partial posterior restorations. This study evaluated the effect of IDS on the fracture strength and failure types of two indirect restorative materials. MATERIALS AND METHODS:Standard MOD inlay preparations were made on sound molars (N=40, n=10 per group) and randomly divided into four groups to receive the inlay materials with and without the application of IDS: Group L-IDS-: Li2Si2O5 (Lithium disilicate, IPS e.max) without IDS; Group L-IDS+: Li2Si2O5 with IDS; Group MR-IDS-: Multiphase resin composite (MR, Lava Ultimate) without IDS; MR-IDS+: MR with IDS. Inlays made of L were etched with 5% hydrofluoric acid, and MR inlays were silica coated. After silanization, they were cemented using adhesive resin cement (Variolink Esthetic DC). The specimens were thermo-mechanically aged (1.2×106 cycles, 1.7Hz, 8000 cycles, 5-55°C) and then subjected to load to failure (1 mm/min). Failure types and locations of debondings were classified. Data were statistically analyzed using ANOVA, Mann Whitney U-test and Chi-square tests (α=0.05). Two-parameter Weibull distribution values including the Weibull modulus, scale (m) and shape (0), values were calculated. RESULTS:After aging conditions, no apparent changes were observed in marginal integrity but occlusal wear facets were more common with MR than with L (p<0.001). Material type and the application of IDS significantly affected the results (p=0.013). While group L-IDS- showed the lowest mean fracture strength (1358±506N) among all groups (p<0.05), application of IDS significantly increased the results significantly (L-IDS+: 2035±403N) (p=0.006). MR groups with and without IDS, did not show significant difference (MR-IDS-: 1861±423, MR-IDS+: 1702±596 N) (p=0.498). When materials without IDS are compared, L showed significantly lower results than that of MR (p=0.035). With the application of IDS, no significant difference was noted between L and MR materials (p=0.160). Weibull distribution presented the highest shape (0) for L-IDS+ (5.66) compared to those of other groups (3.01-4.76). Neither the material type (p=0.830), nor the application of IDS (p=0.54) affected the severity of the failure types. In 95% of the cases, the IDS layer left adhered on the tooth surface after fracture tests. In groups where no IDS was used, resin cement remained on the tooth surface in 44% of the cases (p=0.001). No significant differences were observed between the materials with respect to cement remnants or IDS after fracture (p=0.880). The incidence of repairable failure types (83%) was more common with L than with MR (75%) material (p>0.05). CONCLUSION:Immediate dentin sealing improves adhesion, and thereby the fracture strength of inlays made of lithium disilicate but not that multiphase resin composite.

authors

van den Breemer CRG,Özcan M,Cune MS,van der Giezen R,Kerdijk W,Gresnigt MMM

doi

10.1016/j.jmbbm.2017.04.002

subject

Has Abstract

pub_date

2017-08-01 00:00:00

pages

102-109

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(17)30154-6

journal_volume

72

pub_type

杂志文章
  • An experimental analysis of shell failure in breast implants.

    abstract::Breast implant durability and the mechanisms of rupture are important topics in the medical community, for patients, manufactures and regulatory medical agencies. After concerns about the Poly Implant Prosthesis (PIP) implants, the need for understanding the adverse outcomes and the failure mode to improve the breast ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.04.005

    authors: Ramião NG,Martins PS,Barroso ML,Santos DC,Fernandes AA

    更新日期:2017-08-01 00:00:00

  • Effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading.

    abstract::This study evaluated the effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading. Disc-shaped zirconia specimens (Ø: 15mm, thickness: 1.2mm) (N=32) were submitted to one of the air-particle abrasion protocols (n=8 per...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.01.005

    authors: Ozcan M,Melo RM,Souza RO,Machado JP,Felipe Valandro L,Botttino MA

    更新日期:2013-04-01 00:00:00

  • Mechanical properties of bovine cortical bone based on the automated ball indentation technique and graphics processing method.

    abstract::Cortical bone provides the main form of support in humans and other vertebrates against various forces. Thus, capturing its mechanical properties is important. In this study, the mechanical properties of cortical bone were investigated by using automated ball indentation and graphics processing at both the macroscopic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.039

    authors: Zhang A,Zhang S,Bian C

    更新日期:2018-02-01 00:00:00

  • Environmental fatigue of superelastic NiTi wire with two surface finishes.

    abstract::Surface finish of NiTi is widely perceived to affect its biocompatibility and corrosion fatigue performance. The aim of this work was to find out, whether a carefully engineered surface oxide shows any beneficial effect over electropolished surface on the fatigue performance of superelastic NiTi wire mechanically cycl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104028

    authors: Racek J,Šittner P

    更新日期:2020-11-01 00:00:00

  • Layer-specific residual deformations and uniaxial and biaxial mechanical properties of thoracic porcine aorta.

    abstract::In this paper we hypothesize that the layer-separated residual stresses and mechanical properties of layer-separated thoracic aorta arteries may be dependent on arterial location of the vessel. To demonstrate any possible position differences, we measured the axial pre-stretch and opening angle and performed uniaxial ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.024

    authors: Peña JA,Martínez MA,Peña E

    更新日期:2015-10-01 00:00:00

  • Influence of the overall stiffness of a load-bearing porous titanium implant on bone ingrowth in critical-size mandibular bone defects in sheep.

    abstract::The aim of this work was to assess the influence of reduction of the apparent mechanical properties of fully load-bearing porous titanium implants used in mandibular bone defects. Segmental 18mm long bone defects were created bilaterally in the lower jaws of adult ewes. One group of 6 ewes (group A) was treated with l...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.02.036

    authors: Schouman T,Schmitt M,Adam C,Dubois G,Rouch P

    更新日期:2016-06-01 00:00:00

  • Wear characteristics of WSU total ankle replacement devices under shear and torsion loads.

    abstract:BACKGROUND:There are several factors that contribute to the failure of total ankle replacement (TAR). Aseptic loosening is one of the primary mechanisms of failure in TAR. Since a cross-linked ultrahigh molecular weight polyethylene (UHMWPE) is used as liner material, there is a need to quantify and develop methods to ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.12.010

    authors: Gundapaneni D,Tsatalis JT,Laughlin RT,Goswami T

    更新日期:2015-04-01 00:00:00

  • Interfascicular matrix-mediated transverse deformation and sliding of discontinuous tendon subcomponents control the viscoelasticity and failure of tendons.

    abstract::In the present article, we investigated the sliding of discontinuous tendon subcomponents and the variation of nonhomogeneous deformation in the human Achilles tendon (AT) over time using uniaxial tensile and relaxation tests. The deformation and the resulting strain distribution under uniaxial tension are examined us...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.027

    authors: Obuchowicz R,Ekiert M,Kohut P,Holak K,Ambrozinski L,Tomaszewski KA,Uhl T,Mlyniec A

    更新日期:2019-09-01 00:00:00

  • A combined experimental, modeling, and computational approach to interpret the viscoelastic response of the white matter brain tissue during indentation.

    abstract::Viscoelastic properties of the white matter brain tissue are systematically studied in this paper utilizing indentation experiments, mathematical modeling, and finite element simulation. It is first demonstrated that the internal stiffness of the instrument needs to be thoroughly obtained and incorporated in the analy...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.037

    authors: Samadi-Dooki A,Voyiadjis GZ,Stout RW

    更新日期:2018-01-01 00:00:00

  • Characterization, mechanical properties and corrosion resistance of biocompatible Zn-HA/TiO2 nanocomposite coatings.

    abstract::Biocompatible Zinc-hydroxyapatite-titania and Zinc-hydroxyapatite nanocomposite coatings have been prepared by electrodeposition on NiTi shape memory alloy. Structures of coatings were characterized using X-ray diffraction (XRD). It was found that addition of TiO2 particles cause to reduction of crystallite size of co...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.016

    authors: Mirak M,Alizadeh M,Ghaffari M,Ashtiani MN

    更新日期:2016-09-01 00:00:00

  • Fabrication and mechanical properties of Al2O3/SiC/ZrO2 functionally graded material by electrophoretic deposition.

    abstract::This study describes the synthesis of Al(2)O(3)/SiC/ZrO(2) functionally graded material (FGM) in bio-implants (artificial joints) by electrophoretic deposition (EPD). A suitable suspension that was based on 2-butanone was applied for the EPD of Al(2)O(3)/SiC/ZrO(2), and a pressureless sintering process was applied as ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.02.029

    authors: Askari E,Mehrali M,Metselaar IH,Kadri NA,Rahman MM

    更新日期:2012-08-01 00:00:00

  • A combined strategy to enhance the properties of Zn by laser rapid solidification and laser alloying.

    abstract::The orthopedic application of Zn is limited owing to the poor strength and low plasticity. In this study, a novel strategy by combining rapid solidification obtained by selective laser melting (SLM) and alloying with Mg was proposed to improve the mechanical properties of Zn. The microstructures, mechanical properties...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.03.018

    authors: Yang Y,Yuan F,Gao C,Feng P,Xue L,He S,Shuai C

    更新日期:2018-06-01 00:00:00

  • Dual modified nanosilica particles as reinforcing fillers for dental adhesives: Synthesis, characterization, and properties.

    abstract::A facile procedure has been devised to develop a novel dentin bonding system containing poly (acrylic acid)-grafted-silanized fumed silica particles as reinforcing filler, with high stability of nanoparticle dispersion and enhanced bond strength and mechanical properties. In the first step, the silanization of fumed s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103904

    authors: Mazloom-Jalali A,Taromi FA,Atai M,Solhi L

    更新日期:2020-10-01 00:00:00

  • Loading frequencies up to 20Hz as an alternative to accelerate fatigue strength tests in a Y-TZP ceramic.

    abstract::Considering the interest of the research community in the fatigue behavior of all-ceramic restorations and the time consumed in low-frequency cyclic fatigue tests, this study aimed to investigate the influence of the loading frequency on the zirconia fatigue strength. The biaxial flexural fatigue strength of Y-TZP dis...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.01.008

    authors: Fraga S,Pereira GKR,Freitas M,Kleverlaan CJ,Valandro LF,May LG

    更新日期:2016-08-01 00:00:00

  • An adaptive finite element simulation of fretting wear damage at the head-neck taper junction of total hip replacement: The role of taper angle mismatch.

    abstract::An adaptive finite element simulation was developed to predict fretting wear in a head-neck taper junction of hip joint implant through a two dimensional (2D) model and based on the Archard wear equation. This model represents the most critical section of the head-neck junction which was identified from a 3D model of ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.003

    authors: Fallahnezhad K,Oskouei RH,Badnava H,Taylor M

    更新日期:2017-11-01 00:00:00

  • Constitutive modeling of the passive inflation-extension behavior of the swine colon.

    abstract::In the present work, we propose the first structural constitutive model of the passive mechanical behavior of the swine colon that is validated against physiological inflation-extension tests, and accounts for residual strains. Sections from the spiral colon and the descending colon were considered to investigate pote...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.031

    authors: Patel B,Chen H,Ahuja A,Krieger JF,Noblet J,Chambers S,Kassab GS

    更新日期:2018-01-01 00:00:00

  • Microstructural features influencing the mechanical performance of the Brazil nut (Bertholletia excelsa) mesocarp.

    abstract::Brazil nut (Bertholletia excelsa) fruits are capable of resisting high mechanical forces when released from trees as tall as 50 m, as well as during animal dispersal by sharp-teethed rodents. Thick mesocarp plays a crucial part in seed protection. We investigated the role of microstructure and how sclereids, fibers, a...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104306

    authors: Sonego M,Madia M,Eder M,Fleck C,Pessan LA

    更新日期:2021-01-07 00:00:00

  • Translucency, hardness and strength parameters of PMMA resin containing graphene-like material for CAD/CAM restorations.

    abstract::CAD/CAM restorations can be produced from several ceramic and hybrid materials. The moderate mechanical properties of PMMA based resin have hindered its use for permanent restorations. Recently, a graphene reinforced PMMA namely G-CAM has been introduced for permanent CAD/CAM restorations. Although graphene family mat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103388

    authors: Agarwalla SV,Malhotra R,Rosa V

    更新日期:2019-12-01 00:00:00

  • Dynamic impact testing of hedgehog spines using a dual-arm crash pendulum.

    abstract::Hedgehog spines are a potential model for impact resistant structures and material. While previous studies have examined static mechanical properties of individual spines, actual collision tests on spines analogous to those observed in the wild have not previously been investigated. In this study, samples of roughly 1...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.019

    authors: Swift NB,Hsiung BK,Kennedy EB,Tan KT

    更新日期:2016-08-01 00:00:00

  • Prevention of intestinal adhesion and regeneration of abdominal wall tissue with meshes containing an electrostatically spun acellular dermal matrix (ADM)/silk fibroin (SF) fiber composite polypropylene mesh.

    abstract::The repair of abdominal wall defects often requires the use of polypropylene (PP) as the main material. After a PP mesh is implanted in the body, contact with the intestine can cause adhesions between the intestine and the mesh, leading to serious complications such as intestinal fistula. In this study, we used electr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104087

    authors: Yang D,Song Z,Lin Y,Dong W,Fu S,Yang J,Zhang P,Gu Y

    更新日期:2020-12-01 00:00:00

  • How does lubricant viscosity affect the wear behaviour of VitE-XLPE articulated against CoCr?

    abstract::Using a 50-station pin-on-disc (SuperCTPOD) machine, the influence of lubricant viscosity on the wear of vitamin E blended crosslinked polyethylene was investigated. Five different test lubricants were prepared by mixing different concentrations of carboxymethyl cellulose powder with deionised water. The viscosity ran...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104067

    authors: Kandemir G,Smith S,Chen J,Joyce TJ

    更新日期:2020-12-01 00:00:00

  • Electromyography activity of triceps surae and tibialis anterior muscles related to various sports shoes.

    abstract::Triceps surae (TS) and tibialis anterior (TA) activation patterns have not yet been studied under different types of sport shoes. We hypothesized that sports shoes may reduce the activity patterns of these muscles in relation to barefoot condition. Thus, our main aim was to evaluate the activity patterns of TS and TA ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.05.039

    authors: Roca-Dols A,Elena Losa-Iglesias M,Sánchez-Gómez R,Becerro-de-Bengoa-Vallejo R,López-López D,Palomo-López P,Rodríguez-Sanz D,Calvo-Lobo C

    更新日期:2018-10-01 00:00:00

  • Fracture susceptibility of worn teeth.

    abstract::An experimental simulation study is made to determine the effects of occlusal wear on the capacity of teeth to resist fracture. Tests are carried out on model dome structures, using glass shells to represent enamel and epoxy filler to represent dentin. The top of the domes are ground and polished to produce flat surfa...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.08.028

    authors: Keown AJ,Bush MB,Ford C,Lee JJ,Constantino PJ,Lawn BR

    更新日期:2012-01-01 00:00:00

  • Prediction of Young׳s modulus of trabeculae in microscale using macro-scale׳s relationships between bone density and mechanical properties.

    abstract::According to the literature, there are many mathematical relationships between density of the trabecular bone and mechanical properties obtained in macro-scale testing. In micro-scale, the measurements provide only the ranges of Young׳s modulus of trabeculae, but there are no experimentally tested relationships allowi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.04.011

    authors: Cyganik Ł,Binkowski M,Kokot G,Rusin T,Popik P,Bolechała F,Nowak R,Wróbel Z,John A

    更新日期:2014-08-01 00:00:00

  • Hyper-frequency viscoelastic spectroscopy of biomaterials.

    abstract::With the emergence of new biomaterials and elastography imaging techniques, there is a need for innovative instruments dedicated to viscoelasticity measurements. In this work, we introduce a novel hyper-frequency viscoelastic spectroscopy (HFVS) technique dedicated to characterize soft media subjected to mid-to-very-h...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.03.020

    authors: Hadj Henni A,Schmitt C,Tremblay MÉ,Hamdine M,Heuzey MC,Carreau P,Cloutier G

    更新日期:2011-10-01 00:00:00

  • Biomechanical fatigue analysis of an advanced new carbon fiber/flax/epoxy plate for bone fracture repair using conventional fatigue tests and thermography.

    abstract::The current study is part of an ongoing research program to develop an advanced new carbon fiber/flax/epoxy (CF/flax/epoxy) hybrid composite with a “sandwich structure” as a substitute for metallic materials for orthopedic long bone fracture plate applications. The purpose of this study was to assess the fatigue prope...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:

    authors: Bagheri ZS,El Sawi I,Bougherara H,Zdero R

    更新日期:2014-07-01 00:00:00

  • Mechanical properties and electrochemical behavior of porous Ti-Nb biomaterials.

    abstract::Ti-Nb-based alloys - with their superior mechanical properties and biocompatibility - are attractive biomaterials for orthopedic implants. By producing this alloys with a porous structure, it is possible to achieve mechanical properties similar to that of bone and to facilitate cellular activities. In this study, Ti16...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.018

    authors: Yılmaz E,Gökçe A,Findik F,Gulsoy HO,İyibilgin O

    更新日期:2018-11-01 00:00:00

  • Augmentation of core decompression with synthetic bone graft does not improve mechanical properties of the proximal femur.

    abstract::Core decompression is a minimally invasive surgical technique used to treat patients with avascular necrosis of the femoral head. The procedure requires an entry hole in the lateral cortex of the femur which potentially leaves patients susceptible to subtrochanteric fractures. The purpose of this study was to determin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104263

    authors: Hockett SA,Sherrill JT,Self M,Mears SC,Barnes CL,Mannen EM

    更新日期:2021-03-01 00:00:00

  • Cold-rolling behavior of biomedical Ni-free Co-Cr-Mo alloys: Role of strain-induced ε martensite and its intersecting phenomena.

    abstract::Ni-free Co-Cr-Mo alloys are some of the most difficult-to-work metallic materials used commonly in biomedical applications. Since the difficulty in plastically deforming them limits their use, an in-depth understanding of their plastic deformability is of crucial importance for both academic and practical purposes. In...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.10.021

    authors: Mori M,Yamanaka K,Chiba A

    更新日期:2015-03-01 00:00:00

  • Processing nanoengineered scaffolds through electrospinning and mineralization suitable for biomimetic bone tissue engineering.

    abstract::Processing scaffolds that mimic the extracellular matrix (ECM) of natural bone in structure and chemical composition is a potential promising option for engineering physiologically functional bone tissue. In this article, we report a novel method, by combining electrospinning and mineralization, to process a series of...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.01.007

    authors: Liao S,Murugan R,Chan CK,Ramakrishna S

    更新日期:2008-07-01 00:00:00