Reinforcing effect of graphene oxide reinforcement on the properties of poly (vinyl alcohol) and carboxymethyl tamarind gum based phase-separated film.

Abstract:

:The current study deals with the preparation and the characterization of the PVA-CMT-GO films. The PVA-CMT film was translucent in nature and smooth to touch. The addition of GO resulted in the formation of agglomerated structures. XRD studies suggested that the incorporation of GO increased the average crystallite size. The mechanical properties of the films as determined by stress relaxation studies suggested that all the films were viscoelastic in nature. The drug release study showed a decrease in the amount of the drug release with the increase in the GO content. The PVA-CMT-GO films (without drug) showed certain degree of antimicrobial activity owing to the inherent antimicrobial property of GO. The drug loaded films also showed good antimicrobial property. It was found that the prepared films altered the cell proliferation of the human skin keratinocytes in a composition-dependent manner.

authors

Yadav I,Nayak SK,Rathnam VSS,Banerjee I,Ray SS,Anis A,Pal K

doi

10.1016/j.jmbbm.2018.02.021

subject

Has Abstract

pub_date

2018-05-01 00:00:00

pages

61-71

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(18)30171-1

journal_volume

81

pub_type

杂志文章
  • Augmentation of core decompression with synthetic bone graft does not improve mechanical properties of the proximal femur.

    abstract::Core decompression is a minimally invasive surgical technique used to treat patients with avascular necrosis of the femoral head. The procedure requires an entry hole in the lateral cortex of the femur which potentially leaves patients susceptible to subtrochanteric fractures. The purpose of this study was to determin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104263

    authors: Hockett SA,Sherrill JT,Self M,Mears SC,Barnes CL,Mannen EM

    更新日期:2021-03-01 00:00:00

  • Simultaneous microstructural and mechanical characterization of human corneas at increasing pressure.

    abstract::The cornea, through its shape, is the main contributor to the eye׳s focusing power. Pathological alterations of the cornea strongly affect the eye power. To improve treatments, complex biomechanical models have been developed based on the architecture and mechanical properties of the collagen network in the stroma, th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.031

    authors: Benoit A,Latour G,Marie-Claire SK,Allain JM

    更新日期:2016-07-01 00:00:00

  • Thickness optimization of auricular silicone scaffold based on finite element analysis.

    abstract::An optimized thickness of a transplantable auricular silicone scaffold was researched. The original image data were acquired from CT scans, and reverse modeling technology was used to build a digital 3D model of an auricle. The transplant process was simulated in ANSYS Workbench by finite element analysis (FEA), solid...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.08.032

    authors: Jiang T,Shang J,Tang L,Wang Z

    更新日期:2016-01-01 00:00:00

  • Study on the effect of graphene oxide (GO) feeding on silk properties based on segmented precise measurement.

    abstract::Silk is widely used in the biomedical field (e.g., surgical sutures) for its excellent mechanical properties and biocompatibility. The properties of silk can be further enhanced by a multitude of methods, including nano particle feeding, which is convenient and green. Generally, the filament length of a silkworm cocoo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104147

    authors: Qu J,Dai M,Ye W,Fang Y,Bian D,Su W,Li F,Sun H,Wei J,Li B

    更新日期:2021-01-01 00:00:00

  • Strain-induced microstructural rearrangement in ultra-high molecular weight polyethylene for hip joints: A comparison between conventional and vitamin E-infused highly-crosslinked liners.

    abstract::Infusion of vitamin E (α-tocopherol) in highly crosslinked ultra-high molecular weight polyethylene (UHMWPE) liners has been conceived to achieve superior oxidation stability while preserving enhanced mechanical properties as compared to post-irradiation remelted liners. However, the presence of an antioxidant in the ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.12.009

    authors: Takahashi Y,Yamamoto K,Shishido T,Masaoka T,Tateiwa T,Puppulin L,Pezzotti G

    更新日期:2014-03-01 00:00:00

  • Influence of the overall stiffness of a load-bearing porous titanium implant on bone ingrowth in critical-size mandibular bone defects in sheep.

    abstract::The aim of this work was to assess the influence of reduction of the apparent mechanical properties of fully load-bearing porous titanium implants used in mandibular bone defects. Segmental 18mm long bone defects were created bilaterally in the lower jaws of adult ewes. One group of 6 ewes (group A) was treated with l...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.02.036

    authors: Schouman T,Schmitt M,Adam C,Dubois G,Rouch P

    更新日期:2016-06-01 00:00:00

  • An experimental analysis of shell failure in breast implants.

    abstract::Breast implant durability and the mechanisms of rupture are important topics in the medical community, for patients, manufactures and regulatory medical agencies. After concerns about the Poly Implant Prosthesis (PIP) implants, the need for understanding the adverse outcomes and the failure mode to improve the breast ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.04.005

    authors: Ramião NG,Martins PS,Barroso ML,Santos DC,Fernandes AA

    更新日期:2017-08-01 00:00:00

  • Characterization of persistent concussive syndrome using injury reconstruction and finite element modelling.

    abstract::Concussions occur 1.7 million times a year in North America, and account for approximately 75% of all traumatic brain injuries (TBI). Concussions usually cause transient symptoms but 10 to 20% of patients can have symptoms that persist longer than a month. The purpose of this research was to use reconstructions and fi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.034

    authors: Post A,Kendall M,Koncan D,Cournoyer J,Blaine Hoshizaki T,Gilchrist MD,Brien S,Cusimano MD,Marshall S

    更新日期:2015-01-01 00:00:00

  • R-curve behavior of a short-fiber reinforced resin composite after water storage.

    abstract::As a supplement to our investigation into R-curves in a short-fiber reinforced dental resin composite, we investigate the effects of 2-months water storage. Water is known to degrade the siloxane bonds linking matrix and fillers, which has been suggested to decrease the fracture toughness in conventional resin composi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103674

    authors: Tiu J,Belli R,Lohbauer U

    更新日期:2020-04-01 00:00:00

  • Experimental and constitutive modeling approaches for a study of biomechanical properties of human coronary arteries.

    abstract::The study concerns the determination of mechanical properties of human coronary arterial walls with both experimental and constitutive modeling approaches. The research material was harvested from 18 patients (range 50-84 years). On the basis of hospital records and visual observation, each tissue sample was classifie...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.021

    authors: Jankowska MA,Bartkowiak-Jowsa M,Bedzinski R

    更新日期:2015-10-01 00:00:00

  • Friction of F-actin knots.

    abstract::We use the existing data of force-extension experiments on F-actin molecules tied into knots to compute a value of 0.15 for the static friction coefficient for contact between different parts of the same molecule with itself. This estimate for protein-protein friction is relevant for the stabilization of the 273 known...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2009.08.005

    authors: Kirchner HO,Neukirch S

    更新日期:2010-01-01 00:00:00

  • An investigation of the effect of freezing storage on the biaxial mechanical properties of excised porcine tricuspid valve anterior leaflets.

    abstract::The atrioventricular heart valve (AHV) leaflets are critical to the facilitation of proper unidirectional blood flow through the heart. Previously, studies have been conducted to understand the tissue mechanics of healthy AHV leaflets to inform the development of valve-specific computational models and replacement mat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103438

    authors: Duginski GA,Ross CJ,Laurence DW,Johns CH,Lee CH

    更新日期:2020-01-01 00:00:00

  • Cell adhesion to plasma electrolytic oxidation (PEO) titania coatings, assessed using a centrifuging technique.

    abstract::The adhesion of bovine chondrocytes and human osteoblasts to three titania-based coatings, formed by plasma electrolytic oxidation (PEO), was compared to that on uncoated Ti-6Al-4V substrates, and some comparisons were also made with plasma sprayed hydroxyapatite (HA) coatings. This was done using a centrifuge, with a...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.07.009

    authors: Robinson HJ,Markaki AE,Collier CA,Clyne TW

    更新日期:2011-11-01 00:00:00

  • Bioactive composite for keratoprosthesis skirt.

    abstract::In this study, the fabrication and properties of a synthetic keratoprosthesis skirt for use in osteo-odonto-keratoprosthesis (OOKP) surgery are discussed. In the search for a new material concept, bioactive glass and polymethyl methacrylate (PMMA)-based composites were prepared. Three different bioactive glasses (i.e....

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.05.025

    authors: Laattala K,Huhtinen R,Puska M,Arstila H,Hupa L,Kellomäki M,Vallittu PK

    更新日期:2011-11-01 00:00:00

  • Multiscale FE method for analysis of bone micro-structures.

    abstract::Bones are composed of hierarchical bio-composite materials characterized by complex multiscale structural geometry and behavior. The architecture and the mechanical properties of bone tissue differ at each level of hierarchy. Thus, a multiscale approach for mechanical analysis of bone is imperative. This paper propose...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.03.003

    authors: Podshivalov L,Fischer A,Bar-Yoseph PZ

    更新日期:2011-08-01 00:00:00

  • Comparison of mechanical testing methods for biomaterials: Pipette aspiration, nanoindentation, and macroscale testing.

    abstract::Characterization of the mechanical properties of biological materials is often complicated by small volume, irregular geometry, fragility, and environmental sensitivity. Pipette aspiration and nanoindentation testing deal well with these limitations and have seen increasing use in biomaterial characterization, but lit...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.07.022

    authors: Buffinton CM,Tong KJ,Blaho RA,Buffinton EM,Ebenstein DM

    更新日期:2015-11-01 00:00:00

  • Resin adjustment of three-dimensional printed thermoset occlusal splints: Bonding properties - Short communication.

    abstract:OBJECTIVES:To evaluate the interfacial adhesion of an autopolymerizing acrylic resin to 3D printed thermoset occlusal splints compared to thermoplastic occlusal splints. MATERIALS AND METHODS:Cylinders made of an autopolymerizing acrylic resin were adhered to 3D printed thermoset and also to thermoplastic plates. A di...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.04.011

    authors: Perea-Lowery L,Vallittu PK

    更新日期:2019-07-01 00:00:00

  • Planar biaxial extension of the lumbar facet capsular ligament reveals significant in-plane shear forces.

    abstract::The lumbar facet capsular ligament (FCL) articulates with six degrees of freedom during spinal motions of flexion/extension, lateral bending, and axial rotation. The lumbar FCL is composed of highly aligned collagen fiber bundles on the posterior surface (oriented primarily laterally between the rigid articular facets...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.08.019

    authors: Claeson AA,Barocas VH

    更新日期:2017-01-01 00:00:00

  • Packing of muscles in the rabbit shank influences three-dimensional architecture of M. soleus.

    abstract::Isolated and packed muscles (e.g. in the calf) exhibit different three-dimensional muscle shapes. In packed muscles, cross-sections are more angular compared to the more elliptical ones in isolated muscles. As far as we know, it has not been examined yet, whether the shape of the muscle in its packed condition influen...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.04.006

    authors: Wick C,Böl M,Müller F,Blickhan R,Siebert T

    更新日期:2018-07-01 00:00:00

  • Biomechanical and biochemical protective effect of low-level laser therapy for Achilles tendinitis.

    abstract::For three decades, low level laser therapy (LLLT) has been used for treatment of tendinitis as well as other musculoskeletal diseases. Nevertheless, the biological mechanisms involved remain not completely understood. In this work, the effects of LLLT and of the widely used nonsteroidal anti-inflammatory drug, diclofe...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.028

    authors: Marcos RL,Arnold G,Magnenet V,Rahouadj R,Magdalou J,Lopes-Martins RÁ

    更新日期:2014-01-01 00:00:00

  • Microstructure, mechanical and wear properties of laser surface melted Ti6Al4V alloy.

    abstract::Laser surface melting (LSM) of Ti6Al4V alloy was carried out with an aim to improve properties such as microstructure and wear for implant applications. The alloy substrate was melted at 250W and 400W at a scan velocity of 5mm/s, with input energy of 42J/mm(2) and 68J/mm(2), respectively. The results showed that equia...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.12.001

    authors: Balla VK,Soderlind J,Bose S,Bandyopadhyay A

    更新日期:2014-04-01 00:00:00

  • Preparation of low shrinkage methacrylate-based resin system without Bisphenol A structure by using a synthesized dendritic macromer (G-IEMA).

    abstract::With the growing attention on estrogenic effect of Bisphenol A (BPA), the application of BPA derivatives like Bis-GMA in dental materials has also been doubted. In this research, new BPA free dental resin systems were prepared with synthesized dendritic macromer G-IEMA, UDMA, and TEGDMA. Physicochemical properties, su...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.03.012

    authors: Yu B,Liu F,He J

    更新日期:2014-07-01 00:00:00

  • Collagen tissue treated with chitosan solution in H2O/CO2 mixtures: Influence of clathrates hydrates on the structure and mechanical properties.

    abstract::A mixture of water/carbon dioxide is a "green" perspective solvent from the viewpoint of biomedical applications. Clathrate hydrates are formed this solvent under certain conditions and a very interesting question is the impact of clathrates hydrates on the structure and properties of bovine pericardium, which is used...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.11.015

    authors: Chaschin IS,Bakuleva NP,Grigoriev TE,Krasheninnikov SV,Nikitin LN

    更新日期:2017-03-01 00:00:00

  • Through-thickness stress relaxation in bacterial cellulose hydrogel.

    abstract::Biological hydrogels, e.g. bacterial cellulose (BC) hydrogel, attracted increasing interest in recent decades since they show a good potential for biomedical engineering as replacements of real tissues thanks mainly to their good biocompatibility and fibrous structure. To select potential candidates for such applicati...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.021

    authors: Gao X,Kuśmierczyk P,Shi Z,Liu C,Yang G,Sevostianov I,Silberschmidt VV

    更新日期:2016-06-01 00:00:00

  • On the mechanical characterization and modeling of polymer gel brain substitute under dynamic rotational loading.

    abstract::The use of highly sensitive soft materials has become increasingly apparent in the last few years in numerous industrial fields, due to their viscous and damping nature. Unfortunately these materials remain difficult to characterize using conventional techniques, mainly because of the very low internal forces supporte...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.06.008

    authors: Fontenier B,Hault-Dubrulle A,Drazetic P,Fontaine C,Naceur H

    更新日期:2016-10-01 00:00:00

  • Mechanical properties and thermal behaviour of PEGDMA hydrogels for potential bone regeneration application.

    abstract::Poly(ethylene glycol) hydrogels are currently under investigation as possible scaffold materials for bone regeneration. The main purpose of this research was to analyse the mechanical properties and thermal behaviour of novel photopolymerised poly(ethylene glycol) dimethacrylate (PEGDMA) based hydrogels. The effect of...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.04.004

    authors: Killion JA,Geever LM,Devine DM,Kennedy JE,Higginbotham CL

    更新日期:2011-10-01 00:00:00

  • Mechanical properties and in vitro bioactivity of injectable and self-setting calcium sulfate/nano-HA/collagen bone graft substitute.

    abstract::Calcium sulfate hemihydrate (CSH) was introduced into the mineralized collagen (nHAC) to prepare an injectable and self-setting in situ bone graft substitute. The mechanical properties of materials, which are dependant on the L/S ratio, the content of nHAC and setting accelerator, were discussed based on the satisfyin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.12.007

    authors: Hu NM,Chen Z,Liu X,Liu H,Lian X,Wang X,Cui FZ

    更新日期:2012-08-01 00:00:00

  • Effect of alumina contents on phase stability and mechanical properties of magnesium fluorapatite/alumina composites.

    abstract::The aim of the present work was twofold: to prepare biphasic magnesium fluorapatite (MFA) composites with different amounts of alumina using a two-step sintering process, and to evaluate the effects of various amounts of alumina on the mechanical properties, phase stability, and densification of the composite samples....

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.08.004

    authors: Hejazi MS,Ahmadian M,Meratian M,Fathi MH

    更新日期:2014-12-01 00:00:00

  • A mesoscale study of the degradation of bone structural properties in modeled microgravity conditions.

    abstract::One of the most important alterations that occur in man and experimental animals during spaceflight concerns the skeletal system, and entails important bone loss and degradation of mechanical properties. In the present work we investigate ex vivo the long-term effects of weightlessness (simulated microgravity) on bone...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.01.002

    authors: Cosmi F,Steimberg N,Mazzoleni G

    更新日期:2015-04-01 00:00:00

  • Failure analysis of the fractured wires in sternal perichronal loops.

    abstract::We report failure analysis of sternal wires in two cases in which a perichronal fixation technique was used to close the sternotomy. Various characteristics of the retrieved wires were compared to those of unused wires of the same grade and same manufacturer and with surgical wire specifications. In both cases, wire f...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.02.015

    authors: Chao J,Voces R,Peña C

    更新日期:2011-10-01 00:00:00