Microstructure, mechanical and wear properties of laser surface melted Ti6Al4V alloy.

Abstract:

:Laser surface melting (LSM) of Ti6Al4V alloy was carried out with an aim to improve properties such as microstructure and wear for implant applications. The alloy substrate was melted at 250W and 400W at a scan velocity of 5mm/s, with input energy of 42J/mm(2) and 68J/mm(2), respectively. The results showed that equiaxed α+β microstructure of the substrate changes to mixture of acicular α in β matrix after LSM due to high cooling rates in the range of 2.25×10(-3)K/s and 1.41×10(-3)K/s during LSM. Increasing the energy input increased the thickness of remelted region from 779 to 802µm and 1173 to 1199µm. Similarly, as a result of slow cooling rates under present experimental conditions, the grain size of the alloy increased from 4.8μm to 154-199μm. However, the hardness of the Ti6Al4V alloy increased due to LSM melting and resulted in lowest in vitro wear rate of 3.38×10(-4)mm(3)/Nm compared to untreated substrate with a wear rate of 6.82×10(-4)mm(3)/Nm.

authors

Balla VK,Soderlind J,Bose S,Bandyopadhyay A

doi

10.1016/j.jmbbm.2013.12.001

subject

Has Abstract

pub_date

2014-04-01 00:00:00

pages

335-344

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(13)00412-8

journal_volume

32

pub_type

杂志文章
  • Cell elasticity with altered cytoskeletal architectures across multiple cell types.

    abstract::The cytoskeleton is primarily responsible for providing structural support, localization and transport of organelles, and intracellular trafficking. The structural support is supplied by actin filaments, microtubules, and intermediate filaments, which contribute to overall cell elasticity to varying degrees. We evalua...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.01.022

    authors: Grady ME,Composto RJ,Eckmann DM

    更新日期:2016-08-01 00:00:00

  • A tribo-mechanical analysis of PVA-based building-blocks for implementation in a 2-layered skin model.

    abstract::Poly(vinyl) alcohol hydrogel (PVA) is a well-known polymer widely used in the medical field due to its biocompatibility properties and easy manufacturing. In this work, the tribo-mechanical properties of PVA-based blocks are studied to evaluate their suitability as a part of a structure simulating the length scale dep...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.001

    authors: Morales Hurtado M,de Vries EG,Zeng X,van der Heide E

    更新日期:2016-09-01 00:00:00

  • Alternative processing methods of hybrid porous scaffolds based on gelatin and chitosan.

    abstract::The present work focuses on the development of scaffolds based on gelatin and chitosan using different protocols based on the general processing of phase separation, derived from the fabrication of hydrogels and freeze-drying. The scaffolds were produced with 1 wt% of two different biopolymers, i.e. gelatin (GE) and c...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103472

    authors: Perez-Puyana V,Rubio-Valle JF,Jiménez-Rosado M,Guerrero A,Romero A

    更新日期:2020-02-01 00:00:00

  • The impact of discrete compartments of a multi-compartment collagen-GAG scaffold on overall construct biophysical properties.

    abstract::Orthopedic interfaces such as the tendon-bone junction (TBJ) present unique challenges for biomaterials development. Here we describe a multi-compartment collagen-GAG scaffold fabricated via lyophilization that contains discrete mineralized (CGCaP) and non-mineralized (CG) regions joined by a continuous interface. Mod...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.07.016

    authors: Weisgerber DW,Kelkhoff DO,Caliari SR,Harley BA

    更新日期:2013-12-01 00:00:00

  • Structure and mechanical behaviors of protective armored pangolin scales and effects of hydration and orientation.

    abstract::As natural flexible dermal armor, pangolin scales provide effective protection against predatory threats and possess other notable properties such as anti-adhesion and wear-resistance. In this study, the structure, mechanical properties, deformation and damage behaviors of pangolin scales were systematically investiga...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.11.013

    authors: Liu ZQ,Jiao D,Weng ZY,Zhang ZF

    更新日期:2016-03-01 00:00:00

  • Mechanistic modeling of a nanoscratch test for determination of in situ toughness of bone.

    abstract::The objective of this study was to develop a nanoscratch technique that can be used to measure the in situ toughness of bone at micro/nanostructural levels. Among the currently possible techniques, the surface scratch test may be conducted on very small regions, thus exhibiting a potential in determining the in situ f...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.08.019

    authors: Islam A,Neil Dong X,Wang X

    更新日期:2012-01-01 00:00:00

  • Combined effect of the body mass index and implant size on the wear of retrieved total knee prostheses.

    abstract::Total Knee Arthroplasty is a well-established surgical procedure performed to relieve pain and to restore function in knee osteoarthritis. A proper choice of the implant size is mandatory in order to guarantee the success of the implant and to respect the bone stock of tibial plateau and femoral condyles. The aim of t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.06.012

    authors: Battaglia S,Taddei P,Castiello E,Tozzi S,Sudanese A,Affatato S

    更新日期:2014-10-01 00:00:00

  • Loading frequencies up to 20Hz as an alternative to accelerate fatigue strength tests in a Y-TZP ceramic.

    abstract::Considering the interest of the research community in the fatigue behavior of all-ceramic restorations and the time consumed in low-frequency cyclic fatigue tests, this study aimed to investigate the influence of the loading frequency on the zirconia fatigue strength. The biaxial flexural fatigue strength of Y-TZP dis...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.01.008

    authors: Fraga S,Pereira GKR,Freitas M,Kleverlaan CJ,Valandro LF,May LG

    更新日期:2016-08-01 00:00:00

  • Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting.

    abstract::Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platele...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.05.010

    authors: Murr LE,Amato KN,Li SJ,Tian YX,Cheng XY,Gaytan SM,Martinez E,Shindo PW,Medina F,Wicker RB

    更新日期:2011-10-01 00:00:00

  • Packing of muscles in the rabbit shank influences three-dimensional architecture of M. soleus.

    abstract::Isolated and packed muscles (e.g. in the calf) exhibit different three-dimensional muscle shapes. In packed muscles, cross-sections are more angular compared to the more elliptical ones in isolated muscles. As far as we know, it has not been examined yet, whether the shape of the muscle in its packed condition influen...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.04.006

    authors: Wick C,Böl M,Müller F,Blickhan R,Siebert T

    更新日期:2018-07-01 00:00:00

  • FT-Raman spectroscopic study of human skin subjected to uniaxial stress.

    abstract::Fourier Transform Raman Spectroscopy was used to investigate the molecular changes of structural proteins in human skin subjected to strain. In the Raman spectrum of unstrained skin, bands assigned mainly to collagen and elastin were observed at 1658 cm(-1) (amide I), 1271 and 1255 cm(-1) (amide III), and 935 and 817 ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.11.023

    authors: Gąsior-Głogowska M,Komorowska M,Hanuza J,Mączka M,Zając A,Ptak M,Będziński R,Kobielarz M,Maksymowicz K,Kuropka P,Szotek S

    更新日期:2013-02-01 00:00:00

  • Biomechanics of stomach tissues and structure in patients with obesity.

    abstract::Even though bariatric surgery is one of the most effective treatment option of obesity, post-surgical weight loss is not always ensured, especially in the long term, when many patients experience weight regain. Bariatric procedures are largely based on surgeon's expertise and intra-operative decisions, while an integr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103883

    authors: Carniel EL,Albanese A,Fontanella CG,Pavan PG,Prevedello L,Salmaso C,Todros S,Toniolo I,Foletto M

    更新日期:2020-10-01 00:00:00

  • Characterization of persistent concussive syndrome using injury reconstruction and finite element modelling.

    abstract::Concussions occur 1.7 million times a year in North America, and account for approximately 75% of all traumatic brain injuries (TBI). Concussions usually cause transient symptoms but 10 to 20% of patients can have symptoms that persist longer than a month. The purpose of this research was to use reconstructions and fi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.034

    authors: Post A,Kendall M,Koncan D,Cournoyer J,Blaine Hoshizaki T,Gilchrist MD,Brien S,Cusimano MD,Marshall S

    更新日期:2015-01-01 00:00:00

  • Characterization of a new decellularized bovine pericardial biological mesh: Structural and mechanical properties.

    abstract::Implants made from naturally-derived biomaterials, also called biological meshes or biomeshes, typically derive from decellularized extracellular matrix of either animal or human tissue. Biomeshes have many biomedical applications such as ligament repair, bone and cartilage regeneration and soft tissue replacement. Bo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.12.003

    authors: Bielli A,Bernardini R,Varvaras D,Rossi P,Di Blasi G,Petrella G,Buonomo OC,Mattei M,Orlandi A

    更新日期:2018-02-01 00:00:00

  • Is short term intraoperative application of disinfectants harmful to breast implants in breast reconstruction? An experimental study and literature survey.

    abstract:OBJECTIVES:Bacterial contamination of breast implants and biofilm formation has been discussed as a major reason for implant loss and capsular contraction. Intra- and perioperative treatment of breast implants with disinfectants to prevent bacterial contamination has been frequently reported. Given the increasing aware...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.10.021

    authors: Schmitz M,Schubert DW,Kaschta J,Daenicke J,Walter BL,Horch RE

    更新日期:2019-02-01 00:00:00

  • Micromechanical modelling of oil palm empty fruit bunch fibres containing silica bodies.

    abstract::Experimental and numerical investigation was conducted to study the micromechanics of oil palm empty fruit bunch fibres containing silica bodies. The finite viscoelastic-plastic material model called Parallel Rheological Network model was proposed, that fitted well with cyclic and stress relaxation tensile tests of th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.04.043

    authors: Omar FN,Hanipah SH,Xiang LY,Mohammed MAP,Baharuddin AS,Abdullah J

    更新日期:2016-09-01 00:00:00

  • Environmental fatigue of superelastic NiTi wire with two surface finishes.

    abstract::Surface finish of NiTi is widely perceived to affect its biocompatibility and corrosion fatigue performance. The aim of this work was to find out, whether a carefully engineered surface oxide shows any beneficial effect over electropolished surface on the fatigue performance of superelastic NiTi wire mechanically cycl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104028

    authors: Racek J,Šittner P

    更新日期:2020-11-01 00:00:00

  • Fracture origins in twenty-two dental alumina crowns.

    abstract:OBJECTIVES:The causes of in vivo fractures of all-ceramic dental crowns are not yet fully understood. The fracture origins often occur in the cervical margin in the approximal area, but the reason for this is unclear. The aim of this study was to evaluate the fracture origin of 22 of clinically-failed alumina crowns. ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.08.006

    authors: Øilo M,Quinn GD

    更新日期:2016-01-01 00:00:00

  • Periprosthetic wear particle migration and distribution modelling and the implication for osteolysis in cementless total hip replacement.

    abstract::In total hip replacement (THR), wear particles play a significant role in osteolysis and have been observed in locations as remote as the tip of femoral stem. However, there is no clear understanding of the factors and mechanisms causing, or contributing to particle migration to the periprosthetic tissue. Interfacial ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.01.005

    authors: Alidousti H,Taylor M,Bressloff NW

    更新日期:2014-04-01 00:00:00

  • Mechano-geometrical skeletal muscle fibre characterisation under cyclic and relaxation loading.

    abstract::In the present work, mechano-geometrical characterisations of skeletal muscle fibres in two different deformation states, namely, axial tension and axial compression, were realised. In both cases, cyclic and relaxation tests were performed. Additionally, the changes in the volume of the fibres during deformation were ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104001

    authors: Böl M,Iyer R,Garcés-Schröder M,Kohn S,Dietzel A

    更新日期:2020-10-01 00:00:00

  • Functional and molecular structural analysis of dentine interfaces promoted by a Zn-doped self-etching adhesive and an in vitro load cycling model.

    abstract::The aim of this study was to evaluate if mechanical cycling influences bioactivity and bond strength of resin-dentine interface after bonding with Zn-doped self-etching adhesives. Sound dentine surfaces were bonded with Clearfil SE Bond (SEB), 10 wt% ZnO microparticles or 2 wt% ZnCl2 were added into the SEB primer (P)...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.026

    authors: Toledano M,Aguilera FS,Osorio E,Cabello I,Toledano-Osorio M,Osorio R

    更新日期:2015-10-01 00:00:00

  • Modeling ultrasonic wave propagation in a dental implant - Bone system.

    abstract::The evolution of the bone-implant interface reflects the implant osseointegration and bond strength, thereby determining the overall implant stability in the jawbone. Quantitative ultrasound represents a promising alternative technique to characterize the interfacial integrity, precisely due to the fact that those wav...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103547

    authors: Dorogoy A,Haïat G,Shemtov-Yona K,Rittel D

    更新日期:2020-03-01 00:00:00

  • Interfascicular matrix-mediated transverse deformation and sliding of discontinuous tendon subcomponents control the viscoelasticity and failure of tendons.

    abstract::In the present article, we investigated the sliding of discontinuous tendon subcomponents and the variation of nonhomogeneous deformation in the human Achilles tendon (AT) over time using uniaxial tensile and relaxation tests. The deformation and the resulting strain distribution under uniaxial tension are examined us...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.027

    authors: Obuchowicz R,Ekiert M,Kohut P,Holak K,Ambrozinski L,Tomaszewski KA,Uhl T,Mlyniec A

    更新日期:2019-09-01 00:00:00

  • Computational micromechanics of bioabsorbable magnesium stents.

    abstract::Magnesium alloys are a promising candidate material for an emerging generation of absorbable metal stents. Due to its hexagonal-close-packed lattice structure and tendency to undergo twinning, the deformation behaviour of magnesium is quite different to that of conventional stent materials, such as stainless steel 316...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.01.007

    authors: Grogan JA,Leen SB,McHugh PE

    更新日期:2014-06-01 00:00:00

  • A new longitudinal variation in the structure of collagen fibrils and its relationship to locations of mechanical damage susceptibility.

    abstract::The hierarchical architecture of the collagen fibril is well understood, involving non-integer staggering of collagen molecules which results in a 67 nm periodic molecular density variation termed D-banding. Other than this variation, collagen fibrils are considered to be homogeneous at the micro-scale and beyond. Int...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103849

    authors: Baldwin SJ,Sampson J,Peacock CJ,Martin ML,Veres SP,Lee JM,Kreplak L

    更新日期:2020-10-01 00:00:00

  • Clamping soft biologic tissues for uniaxial tensile testing: A brief survey of current methods and development of a novel clamping mechanism.

    abstract::Biologic tissues are complex materials that come in many forms and perform a variety of functions. They vary widely in composition and mechanical properties, and determination of the mechanical properties of tissues is of interest to those trying to engineer tissues to restore missing function. In performing experimen...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103503

    authors: Jiang M,Lawson ZT,Erel V,Pervere S,Nan T,Robbins AB,Feed AD,Moreno MR

    更新日期:2020-03-01 00:00:00

  • Study the bonding mechanism of binders on hydroxyapatite surface and mechanical properties for 3DP fabrication bone scaffolds.

    abstract::In 3DP fabricating artificial bone scaffolds process, the interaction mechanism between binder and bioceramics power determines the microstructure and macro mechanical properties of Hydroxyapatite (HA) bone scaffold. In this study, we applied Molecular Dynamics (MD) methods to investigating the bonding mechanism and e...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.007

    authors: Wei Q,Wang Y,Li X,Yang M,Chai W,Wang K,zhang Y

    更新日期:2016-04-01 00:00:00

  • Impaired mechanics and matrix metalloproteinases/inhibitors expression in female ascending thoracic aortic aneurysms.

    abstract::We hypothesized that female gender may have a specific negative impact on the mechanical characteristics, composition, and expression of matrix metalloproteinases/tissue inhibitors (MMPs/TIMPs) in the wall of ascending thoracic aortic aneurysms (ATAAs). Degenerative ATAAs were resected from 35 patients (age: 67±2 year...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.02.015

    authors: Sokolis DP,Iliopoulos DC

    更新日期:2014-06-01 00:00:00

  • Wear characteristics of WSU total ankle replacement devices under shear and torsion loads.

    abstract:BACKGROUND:There are several factors that contribute to the failure of total ankle replacement (TAR). Aseptic loosening is one of the primary mechanisms of failure in TAR. Since a cross-linked ultrahigh molecular weight polyethylene (UHMWPE) is used as liner material, there is a need to quantify and develop methods to ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.12.010

    authors: Gundapaneni D,Tsatalis JT,Laughlin RT,Goswami T

    更新日期:2015-04-01 00:00:00

  • The error of tensile strength tests and an approach for improvement.

    abstract:OBJECTIVES:The deviation and spread of values measured by tensile strength tests should be significantly reduced by optimized axially pull-off-device. MATERIAL AND METHODS:Factors like geometry, roughness, surface texture and fit of the specimens, the luting procedure (mixing ratio, compacting pressure) were standardi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.003

    authors: Behr M,Fuerst J,Rosentritt M

    更新日期:2018-11-01 00:00:00