Abstract:
:The cornea, through its shape, is the main contributor to the eye׳s focusing power. Pathological alterations of the cornea strongly affect the eye power. To improve treatments, complex biomechanical models have been developed based on the architecture and mechanical properties of the collagen network in the stroma, the main layer of the cornea. However, direct investigations of the structure of the stroma, as well as its link to the mechanical response, remained limited. We propose here an original set up, associating nonlinear optical imaging and mechanical testing. By using polarization resolved Second Harmonic signals, we simultaneously quantified micrometer (orientation of the collagen lamellae) and nanometer (local disorder within lamellae) scale corneal organization. We showed that the organization of the lamellae changes along the stroma thickness. Then, we measured simultaneously the deformation on the epithelial side of the cornea and the reorientation of the collagen lamellae for increasing intraocular pressure levels, from physiological ones to pathological ones. We showed that the observed deformation is not correlated to initial orientation, but to the reorganization of the lamellae in the stroma. Our results, by providing a direct multi-scale observation, will be useful for the development of more accurate biomechanical models.
journal_name
J Mech Behav Biomed Materauthors
Benoit A,Latour G,Marie-Claire SK,Allain JMdoi
10.1016/j.jmbbm.2015.12.031subject
Has Abstractpub_date
2016-07-01 00:00:00pages
93-105eissn
1751-6161issn
1878-0180pii
S1751-6161(15)00505-6journal_volume
60pub_type
杂志文章abstract::The differentiation of hepatic stellate cells (HSCs) into myofibroblasts is a key event in liver fibrosis. Due to the local stiffening of the extracellular matrix (ECM) during fibrosis, it is of great interest to develop mimics that can be used to investigate the cellular response to changes in mechanics. Here, we use...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.11.008
更新日期:2014-10-01 00:00:00
abstract:PURPOSE:To compare osseointegration and implant stability of two types of laser-etched (LE) Ti implants with a chemically-modified, sandblasted, large-grit and acid-etched (SLA) Ti implant (SLActive(®), Straumann, Basel, Switzerland), by evaluating removal torque and resonance frequency between the implant surface and ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.03.034
更新日期:2016-08-01 00:00:00
abstract::Continuous fibre distribution models can be applied to a variety of biological tissues with both charged and neutral extracellular matrices. In particular, ellipsoidal models have been used to describe the complex material behaviour of tissues such as articular cartilage and their engineered tissue equivalents. The ch...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.01.006
更新日期:2012-05-01 00:00:00
abstract::The spatial and temporal changes of morphological and mechanical properties of living cells reflect complex functionally-associated processes. Monitoring these modifications could provide a direct information on the cellular functional state. Here we present an integrated biophysical approach to the quantification of ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.103581
更新日期:2020-03-01 00:00:00
abstract::This study describes the synthesis of Al(2)O(3)/SiC/ZrO(2) functionally graded material (FGM) in bio-implants (artificial joints) by electrophoretic deposition (EPD). A suitable suspension that was based on 2-butanone was applied for the EPD of Al(2)O(3)/SiC/ZrO(2), and a pressureless sintering process was applied as ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.02.029
更新日期:2012-08-01 00:00:00
abstract::Geometric confinement to the nanoscale, a concept that refers to the characteristic dimensions of structural features of materials at this length scale, has been shown to control the mechanical behavior of many biological materials or their building blocks, and such effects have also been suggested to play a crucial r...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.12.005
更新日期:2013-04-01 00:00:00
abstract::Infection incidence for total hip and knee arthroplasty (THA and TKA, respectively) is between 0.2% and 5% and results in approximately 100,000 device failures per year in the United States. Treatment requires prolonged systemic antibiotic therapy with additional surgical revisions. As a prophylactic measure against i...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.06.033
更新日期:2018-11-01 00:00:00
abstract::Pressure ulcers (PUs) are common in patients who chronically depend on a wheelchair for mobility, such as those with a spinal cord injury (SCI). In attempt to prevent the formation of PUs, pressure relieving maneuvers, such as push-ups, are commonly recommended for individuals with SCI. However, very little is known a...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.04.015
更新日期:2013-12-01 00:00:00
abstract::An unusual type of mechanical behavior was registered while studying the swollen hydrogel compositions "cellulose-polyacrylamide" in the conditions of multiple cyclic compression tests with the broad variation of the deformation speed. While increasing the deformation rate the clearly seen inversion of the positions o...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.03.030
更新日期:2017-07-01 00:00:00
abstract::The superior biotribological performance of nanocrystalline diamond (NCD) coatings grown by a chemical vapor deposition (CVD) method was already shown to demonstrate high wear resistance in ball on plate experiments under physiological liquid lubrication. However, tests with a close-to-real approach were missing and t...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.05.005
更新日期:2015-09-01 00:00:00
abstract::After insertion into bone, dental implants may be subjected to tribocorrosive conditions resulting in the release of metallic ions and solid wear debris, which can induce to peri-implant inflammatory reactions accompanied by bone loss, and ultimately implant loosening. Despite the promising ability of TiO2 nanotubes (...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2018.01.038
更新日期:2018-04-01 00:00:00
abstract::As natural flexible dermal armor, pangolin scales provide effective protection against predatory threats and possess other notable properties such as anti-adhesion and wear-resistance. In this study, the structure, mechanical properties, deformation and damage behaviors of pangolin scales were systematically investiga...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.11.013
更新日期:2016-03-01 00:00:00
abstract:AIM OF THE STUDY:The aim of this study was to evaluate the effect of solvent/disinfectant ethanol on the surface of denture base polymers. Changes in surface roughness, topography and some nanomechanical properties were assessed by SEM and nanoindentation plotted against different concentrations of ethanol on heat cure...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.09.007
更新日期:2016-02-01 00:00:00
abstract::Fibrin sealant (FS) is a biomaterial that exhibits hemostatic and repairing properties. It has been successfully used as scaffolds and adhesives to improve repair and regeneration of tissues. The objective of this study was to evaluate the effect of FS in the regeneration process of bone defects in male rat tibias thr...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2020.103662
更新日期:2020-04-01 00:00:00
abstract::Biocompatible polymers are commonly used to fabricate microfluidic channels for the study of biological flows such as blood microflows. The most common of these materials is polydimethylsiloxane (PDMS) which is very hydrophobic. Oxygenated plasma is advocated to treat the PDMS with reported decreases in contact angle ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.07.007
更新日期:2013-01-01 00:00:00
abstract::Intervertebral discs (IVDs) maintain flexibility of the spine and bear mechanical load. Annulus fibrosus (AF) defects are associated with IVD degeneration and herniation which disrupt biomechanical function and can cause pain. AF puncture injuries can induce IVD degeneration but are needed to inject therapies. Identif...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2019.03.024
更新日期:2019-07-01 00:00:00
abstract::An experimental evaluation of intertubular and peritubular dentin was performed using nanoindentation and Dynamic Mechanical Analysis (DMA). The objective of the investigation was to evaluate the differences in dynamic mechanical behavior of these two constituents and to assess whether their response is frequency depe...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.08.010
更新日期:2012-03-01 00:00:00
abstract:OBJECTIVE:To introduce an experimental non-carious cervical lesion (NCCL) model for studying the influence of presence and type of stress (tension or compression) on acid effects involved in NCCL formation on the enamel near the cement-enamel junction (CEJ). METHODS:108 bovine incisors were cut into 18 × 3×3 mm3 beams...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2016.11.003
更新日期:2017-02-01 00:00:00
abstract::Tribological properties of perfluoropolyether (PFPE) coated 3-glycidoxypropyltrimethoxy silane (GPTMS) SAMs (self-assembled monolayers) onto Ti6Al4V alloy substrate were studied using ball-on-disk experiments. GPTMS SAMs deposition onto a Ti6Al4V alloy surface was carried out using solution phase method. Ultra-thin la...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2012.06.016
更新日期:2012-11-01 00:00:00
abstract::While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy stor...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.04.009
更新日期:2015-12-01 00:00:00
abstract::Clinical meshes used in pelvic organ prolapse (POP) repair are predominantly manufactured from monofilament polypropylene (PP). Complications from the use of these meshes in transvaginal kits, including mesh exposure and pain, have prompted two public health notifications by the FDA. The aim of this study was to compa...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2013.04.002
更新日期:2013-07-01 00:00:00
abstract::With increasing interest in treating osteoarthritis at its earliest stages, it has become important to understand the mechanisms by which the disease progresses across a joint. Here, second harmonic generation (SHG) microscopy, coupled with a two-dimensional spring-mass network model, was used to image and investigate...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.08.004
更新日期:2012-01-01 00:00:00
abstract::In the present work, we propose the first structural constitutive model of the passive mechanical behavior of the swine colon that is validated against physiological inflation-extension tests, and accounts for residual strains. Sections from the spiral colon and the descending colon were considered to investigate pote...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.08.031
更新日期:2018-01-01 00:00:00
abstract::Restitution of the natural organization and orientation of cells is imperative for the construction of functional tissue scaffolds. While numerous studies have exploited mechanical methods to engineer tissues with the desired cellular architecture, fundamental knowledge is still lacking in understanding the manner in ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.09.018
更新日期:2018-01-01 00:00:00
abstract::This paper presents a projection method for deriving membrane models from the corresponding three-dimensional material models. As a particular example the anisotropic Holzapfel-Gasser-Ogden model is considered. The projection procedure is based on the kinematical and constitutive assumptions of a general membrane theo...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.09.001
更新日期:2016-05-01 00:00:00
abstract::Imprecise knowledge on the composition-processing-microstructure-property correlation of titanium alloys combined with experimental data are used for developing rule based models for predicting the strength and elastic modulus of titanium alloys. The developed models are used for designing alloys suitable for orthoped...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2015.08.039
更新日期:2016-01-01 00:00:00
abstract::An adaptive finite element simulation was developed to predict fretting wear in a head-neck taper junction of hip joint implant through a two dimensional (2D) model and based on the Archard wear equation. This model represents the most critical section of the head-neck junction which was identified from a 3D model of ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2017.07.003
更新日期:2017-11-01 00:00:00
abstract::The current study is part of an ongoing research program to develop an advanced new carbon fiber/flax/epoxy (CF/flax/epoxy) hybrid composite with a “sandwich structure” as a substitute for metallic materials for orthopedic long bone fracture plate applications. The purpose of this study was to assess the fatigue prope...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:
更新日期:2014-07-01 00:00:00
abstract::Poly (glycerol sebacate) (PGS) is a promising elastomer for use in soft tissue engineering. However, it is difficult to achieve with PGS a satisfactory balance of mechanical compliance and degradation rate that meet the requirements of soft tissue engineering. In this work, we have synthesised a new PGS nanocomposite ...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.05.038
更新日期:2011-11-01 00:00:00
abstract::The age-related deterioration in the quality (e.g., strength and fracture resistance) and quantity (e.g., bone-mineral density) of human bone, together with increased life expectancy, is responsible for increasing incidence of bone fracture in the elderly. The present study describes ex vivo fracture experiments to qu...
journal_title:Journal of the mechanical behavior of biomedical materials
pub_type: 杂志文章
doi:10.1016/j.jmbbm.2011.05.020
更新日期:2011-10-01 00:00:00