The High performance of nanocrystalline CVD diamond coated hip joints in wear simulator test.

Abstract:

:The superior biotribological performance of nanocrystalline diamond (NCD) coatings grown by a chemical vapor deposition (CVD) method was already shown to demonstrate high wear resistance in ball on plate experiments under physiological liquid lubrication. However, tests with a close-to-real approach were missing and this constitutes the aim of the present work. Hip joint wear simulator tests were performed with cups and heads made of silicon nitride coated with NCD of ~10 μm in thickness. Five million testing cycles (Mc) were run, which represent nearly five years of hip joint implant activity in a patient. For the wear analysis, gravimetry, profilometry, scanning electron microscopy and Raman spectroscopy techniques were used. After 0.5 Mc of wear test, truncation of the protruded regions of the NCD film happened as a result of a fine-scale abrasive wear mechanism, evolving to extensive plateau regions and highly polished surface condition (Ra<10nm). Such surface modification took place without any catastrophic features as cracking, grain pullouts or delamination of the coatings. A steady state volumetric wear rate of 0.02 mm(3)/Mc, equivalent to a linear wear of 0.27 μm/Mc favorably compares with the best performance reported in the literature for the fourth generation alumina ceramic (0.05 mm(3)/Mc). Also, squeaking, quite common phenomenon in hard-on-hard systems, was absent in the present all-NCD system.

authors

Maru MM,Amaral M,Rodrigues SP,Santos R,Gouvea CP,Archanjo BS,Trommer RM,Oliveira FJ,Silva RF,Achete CA

doi

10.1016/j.jmbbm.2015.05.005

subject

Has Abstract

pub_date

2015-09-01 00:00:00

pages

175-85

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(15)00163-0

journal_volume

49

pub_type

杂志文章
  • Fracture susceptibility of worn teeth.

    abstract::An experimental simulation study is made to determine the effects of occlusal wear on the capacity of teeth to resist fracture. Tests are carried out on model dome structures, using glass shells to represent enamel and epoxy filler to represent dentin. The top of the domes are ground and polished to produce flat surfa...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.08.028

    authors: Keown AJ,Bush MB,Ford C,Lee JJ,Constantino PJ,Lawn BR

    更新日期:2012-01-01 00:00:00

  • Effects of age and loading rate on equine cortical bone failure.

    abstract::Although clinical bone fractures occur predominantly under impact loading (as occurs during sporting accidents, falls, high-speed impacts or other catastrophic events), experimentally validated studies on the dynamic fracture behavior of bone, at the loading rates associated with such events, remain limited. In this s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2010.09.006

    authors: Kulin RM,Jiang F,Vecchio KS

    更新日期:2011-01-01 00:00:00

  • On collagen fiber morphoelasticity and homeostatic remodeling tone.

    abstract::A variety of biochemical and physical processes participate in the creation and maintenance of collagen in biological tissue. Under mechanical stimuli these collagen fibers undergo continuous processes of morphoelastic change. The model presented here is motivated by experimental reports of stretch-stabilization of th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104154

    authors: Topol H,Demirkoparan H,Pence TJ

    更新日期:2021-01-01 00:00:00

  • RETRACTED: Mechanical properties and phase transition of biomedical titanium alloy strips with initial quasi-single phase state under high-energy electropulses.

    abstract::This article has been retracted: please see Elsevier Policy on Article Withdrawal (http://www.elsevier.com/locate/withdrawalpolicy). This article has been retracted at the request of the Editor-in-Chief. The authors have reused figures and text that have already appeared in their previous articles. Figure 4 duplicat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,收录出版

    doi:10.1016/j.jmbbm.2014.11.009

    authors: Ye X,Tse ZT,Tang G,Song G

    更新日期:2015-02-01 00:00:00

  • A low-shrinkage dental composite with epoxy-polyhedral oligomeric silsesquioxane.

    abstract::Polymerization shrinkage and mechanical properties affect the service life of dental restorative composites. Polyhedral oligomeric silsesquioxanes (POSS) can be an efficient strategy to improve the shrinkage properties and mechanical properties simultaneously. In this work, epoxycyclohexyl POSS (E-POSS) was used to mo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103515

    authors: Li Z,Zhang H,Xiong G,Zhang J,Guo R,Li L,Zhou H,Chen G,Zhou Z,Li Q

    更新日期:2020-03-01 00:00:00

  • Tribological behavior of Ti-6Al-4V against cortical bone in different biolubricants.

    abstract::Titanium alloys (Ti-6Al-4V) are promising materials as bone implants in clinical surgeries owing to their excellent performances. However, wear debris caused by the tribological behavior of the cortical bone and titanium alloy interface were found to be paramount for implant stability. The contact environment between ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.10.031

    authors: Wang C,Zhang G,Li Z,Zeng X,Xu Y,Zhao S,Hu H,Zhang Y,Ren T

    更新日期:2019-02-01 00:00:00

  • Numerical study of temperature effects on the poro-viscoelastic behavior of articular cartilage.

    abstract::This paper presents a new approach to study the effects of temperature on the poro- elastic and viscoelastic behavior of articular cartilage. Biphasic solid-fluid mixture theory is applied to study the poro-mechanical behavior of articular cartilage in a fully saturated state. The balance of linear momentum, mass, and...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.023

    authors: Behrou R,Foroughi H,Haghpanah F

    更新日期:2018-02-01 00:00:00

  • Monotonic and cyclic loading behavior of porous scaffolds made from poly(para-phenylene) for orthopedic applications.

    abstract::Porous poly(para-phenylene) (PPP) scaffolds have tremendous potential as an orthopedic biomaterial; however, the underlying mechanisms controlling the monotonic and cyclic behavior are poorly understood. The purpose of this study was to develop a method to integrate micro-computed tomography (μCT), finite-element anal...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.10.004

    authors: Hoyt AJ,Yakacki CM,Fertig RS 3rd,Dana Carpenter R,Frick CP

    更新日期:2015-01-01 00:00:00

  • Contact angle study of blood dilutions on common microchip materials.

    abstract::Biocompatible polymers are commonly used to fabricate microfluidic channels for the study of biological flows such as blood microflows. The most common of these materials is polydimethylsiloxane (PDMS) which is very hydrophobic. Oxygenated plasma is advocated to treat the PDMS with reported decreases in contact angle ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.07.007

    authors: Pitts KL,Abu-Mallouh S,Fenech M

    更新日期:2013-01-01 00:00:00

  • Effect of solid distribution on elastic properties of open-cell cellular solids using numerical and experimental methods.

    abstract::Effect of solid distribution between edges and vertices of three-dimensional cellular solid with an open-cell structure was investigated both numerically and experimentally. Finite element analysis (FEA) with continuum elements and appropriate periodic boundary condition was employed to calculate the elastic propertie...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.05.018

    authors: Zargarian A,Esfahanian M,Kadkhodapour J,Ziaei-Rad S

    更新日期:2014-09-01 00:00:00

  • Biomechanical, structural and biological characterisation of a new silk fibroin scaffold for meniscal repair.

    abstract::Meniscal injury is typically treated surgically via partial meniscectomy, which has been shown to cause cartilage degeneration in the long-term. Consequently, research has focused on meniscal prevention and replacement. However, none of the materials or implants developed for meniscal replacement have yet achieved wid...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.06.041

    authors: Warnecke D,Stein S,Haffner-Luntzer M,de Roy L,Skaer N,Walker R,Kessler O,Ignatius A,Dürselen L

    更新日期:2018-10-01 00:00:00

  • Interfascicular matrix-mediated transverse deformation and sliding of discontinuous tendon subcomponents control the viscoelasticity and failure of tendons.

    abstract::In the present article, we investigated the sliding of discontinuous tendon subcomponents and the variation of nonhomogeneous deformation in the human Achilles tendon (AT) over time using uniaxial tensile and relaxation tests. The deformation and the resulting strain distribution under uniaxial tension are examined us...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.027

    authors: Obuchowicz R,Ekiert M,Kohut P,Holak K,Ambrozinski L,Tomaszewski KA,Uhl T,Mlyniec A

    更新日期:2019-09-01 00:00:00

  • Fabrication and mechanical properties of Al2O3/SiC/ZrO2 functionally graded material by electrophoretic deposition.

    abstract::This study describes the synthesis of Al(2)O(3)/SiC/ZrO(2) functionally graded material (FGM) in bio-implants (artificial joints) by electrophoretic deposition (EPD). A suitable suspension that was based on 2-butanone was applied for the EPD of Al(2)O(3)/SiC/ZrO(2), and a pressureless sintering process was applied as ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.02.029

    authors: Askari E,Mehrali M,Metselaar IH,Kadri NA,Rahman MM

    更新日期:2012-08-01 00:00:00

  • Simulating damage onset and evolution in fully bio-resorbable composite under three-point bending.

    abstract::This paper presents a strain-based damage model to predict the stress-strain relationship and investigate the damage onset and evolution of the fibre and matrix of a fully bio-resorbable phosphate glass fibre reinforced composite under three-point bending. The flexural properties of the composite are crucial, particul...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.02.022

    authors: Gao X,Chen M,Yang X,Harper L,Ahmed I,Lu J

    更新日期:2018-05-01 00:00:00

  • Tribological properties of Ti-based alloys in a simulated bone-implant interface with Ringer's solution at fretting contacts.

    abstract::The wear properties of oxidized and non-oxidized gamma-TiAl (a potential biomaterial) as well as Ti-6Al-4V and CP-Ti disks were studied and characterized by means of standard wear tests using a custom made bone pin arrangement. The Ti-based disks were oxidized in air at 500 and 800 degrees C for one hour. The tribolog...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2010.06.006

    authors: Ramos-Saenz CR,Sundaram PA,Diffoot-Carlo N

    更新日期:2010-11-01 00:00:00

  • Anatomic variation in the elastic anisotropy of cortical bone tissue in the human femur.

    abstract::Experimental investigations for anatomic variation in the magnitude and anisotropy of elastic constants in human femoral cortical bone tissue have typically focused on a limited number of convenient sites near the mid-diaphysis. However, the proximal and distal ends of the diaphysis are more clinically relevant to com...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.08.005

    authors: Espinoza Orías AA,Deuerling JM,Landrigan MD,Renaud JE,Roeder RK

    更新日期:2009-07-01 00:00:00

  • Bone healing response in cyclically loaded implants: Comparing zero, one, and two loading sessions per day.

    abstract::When bone implants are loaded, they are inevitably subjected to displacement relative to bone. Such micromotion generates stress/strain states at the interface that can cause beneficial or detrimental sequels. The objective of this study is to better understand the mechanobiology of bone healing at the tissue-implant ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.05.044

    authors: de Barros E Lima Bueno R,Dias AP,Ponce KJ,Wazen R,Brunski JB,Nanci A

    更新日期:2018-09-01 00:00:00

  • The functions of hydrophobic elastic polyurethane combined with an antibacterial triclosan derivative in the dentin restoration interface.

    abstract::Dentin restoration produces weak interfaces because of the effects of bacterial microflora, biofilms, and mechanical, thermal, and shrinkage stresses. This results in secondary caries. Therefore, hydrophobic elastic polyurethane (PU) containing different concentrations of triclosan derivatives was synthesized and appl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103471

    authors: Guo X,Cheng Q,Yu G,Wang H,Tian Z,Shi Z,Cui Z,Zhu S

    更新日期:2020-02-01 00:00:00

  • New regime in the mechanical behavior of skin: strain-softening occurring before strain-hardening.

    abstract::We report linear and non-linear shear tests on rat skin, evidencing a strain-softening regime, from 1% to 50% strain, followed by a strong strain-hardening regime, leading to a 'deck chair-shaped' stress-strain curve. The strain-softening regime was never reported as such in the literature, possibly mistaken for the l...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.12.021

    authors: Nicolle S,Decorps J,Fromy B,Palierne JF

    更新日期:2017-05-01 00:00:00

  • Improved tribocorrosion performance of bio-functionalized TiO2 nanotubes under two-cycle sliding actions in artificial saliva.

    abstract::After insertion into bone, dental implants may be subjected to tribocorrosive conditions resulting in the release of metallic ions and solid wear debris, which can induce to peri-implant inflammatory reactions accompanied by bone loss, and ultimately implant loosening. Despite the promising ability of TiO2 nanotubes (...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.01.038

    authors: Alves SA,Rossi AL,Ribeiro AR,Toptan F,Pinto AM,Shokuhfar T,Celis JP,Rocha LA

    更新日期:2018-04-01 00:00:00

  • Fracture resistance of CAD/CAM occlusal veneers: A systematic review of laboratory studies.

    abstract:OBJECTIVE:The purpose of this systematic review was to summarize scientific evidence that evaluates in vitro fracture and fatigue strength of occlusal veneers in different thicknesses, CAD/CAM materials, and under different aging methodologies. MATERIALS AND METHODS:An electronic search of 3 English databases (The Nat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,评审

    doi:10.1016/j.jmbbm.2020.103948

    authors: Albelasy EH,Hamama HH,Tsoi JKH,Mahmoud SH

    更新日期:2020-10-01 00:00:00

  • Functional and molecular structural analysis of dentine interfaces promoted by a Zn-doped self-etching adhesive and an in vitro load cycling model.

    abstract::The aim of this study was to evaluate if mechanical cycling influences bioactivity and bond strength of resin-dentine interface after bonding with Zn-doped self-etching adhesives. Sound dentine surfaces were bonded with Clearfil SE Bond (SEB), 10 wt% ZnO microparticles or 2 wt% ZnCl2 were added into the SEB primer (P)...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.026

    authors: Toledano M,Aguilera FS,Osorio E,Cabello I,Toledano-Osorio M,Osorio R

    更新日期:2015-10-01 00:00:00

  • Thermo-mechanical behavior and structure of melt blown shape-memory polyurethane nonwovens.

    abstract::New processing methods for shape-memory polymers allow for tailoring material properties for numerous applications. Shape-memory nonwovens have been previously electrospun, but melt blow processing has yet to be evaluated. In order to determine the process parameters affecting shape-memory behavior, this study examine...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.038

    authors: Safranski DL,Boothby JM,Kelly CN,Beatty K,Lakhera N,Frick CP,Lin A,Guldberg RE,Griffis JC

    更新日期:2016-09-01 00:00:00

  • How does lubricant viscosity affect the wear behaviour of VitE-XLPE articulated against CoCr?

    abstract::Using a 50-station pin-on-disc (SuperCTPOD) machine, the influence of lubricant viscosity on the wear of vitamin E blended crosslinked polyethylene was investigated. Five different test lubricants were prepared by mixing different concentrations of carboxymethyl cellulose powder with deionised water. The viscosity ran...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104067

    authors: Kandemir G,Smith S,Chen J,Joyce TJ

    更新日期:2020-12-01 00:00:00

  • The posterior eye with age-related macular degeneration has isotropic and nonlinear viscoelastic properties.

    abstract::Here we characterize and compare the anisotropic and nonlinear viscoelastic properties of the posterior eye of advanced dry age-related macular degeneration (AMD) patients and age-matched normal subjects. Ten normal horizontal, ten normal vertical, ten AMD horizontal, and ten AMD vertical strips of the macular retina ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104207

    authors: He Y,Guo Y,Wang J,Lv W,Li X,Chen K

    更新日期:2021-02-01 00:00:00

  • Mechanical properties and electrochemical behavior of porous Ti-Nb biomaterials.

    abstract::Ti-Nb-based alloys - with their superior mechanical properties and biocompatibility - are attractive biomaterials for orthopedic implants. By producing this alloys with a porous structure, it is possible to achieve mechanical properties similar to that of bone and to facilitate cellular activities. In this study, Ti16...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.018

    authors: Yılmaz E,Gökçe A,Findik F,Gulsoy HO,İyibilgin O

    更新日期:2018-11-01 00:00:00

  • Wear characterization and contact surfaces analysis of menisci and femoral retrieved components in bi-condylar knee prostheses.

    abstract:PURPOSE:Although total knee arthroplasty is a well-practiced surgical procedure, material properties and surface topography can contribute to the wear mechanisms and the implant failure. It has been advised that an increased femoral component's surface roughness of total knee prostheses may be a contributing factor to ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103959

    authors: Affatato S,Ruzzi S,Milosevic M,Ruggiero A

    更新日期:2020-10-01 00:00:00

  • Mechanisms and timing of injury to the thoracic, lumbar and sacral spine in simulated underbody blast PMHS impact tests.

    abstract::During an underbody blast (UBB) event, mounted occupants are exposed to high rate loading of the spine via the pelvis. The objective of this study was to simulate UBB loading conditions and examine mechanisms of injury in the thoracic, lumbar and sacral spine. Fourteen instrumented, whole-body, postmortem human subjec...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104271

    authors: Somasundaram K,Sherman D,Begeman P,Ciarelli T,McCarty SA,Kochkodan JJ,Demetropoulos CK,Cavanaugh JM

    更新日期:2020-12-24 00:00:00

  • Mechanical characterization of bio composite films as a novel drug carrier platform for sustained release of 5-fluorouracil for colon cancer: Methodological investigation.

    abstract::In this study, we employed Pectin (PC) as a matrix that is hybridized with three different nucleobase (NB) units (cytosine, thymine, uracil) to generate pectin-nucleobase(PC-NB) biocomposite films stabilized through bio-multiple hydrogen bonds (BMHBs) as drug carrier for anticancer 5-Fluorouracil (5-FU). Prepared bioc...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104266

    authors: Tamilselvi S,Kavitha R,Usharani M,Mumjitha M,Mohanapriya S,MohanaPriya S

    更新日期:2021-03-01 00:00:00

  • Failure analysis of the fractured wires in sternal perichronal loops.

    abstract::We report failure analysis of sternal wires in two cases in which a perichronal fixation technique was used to close the sternotomy. Various characteristics of the retrieved wires were compared to those of unused wires of the same grade and same manufacturer and with surgical wire specifications. In both cases, wire f...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.02.015

    authors: Chao J,Voces R,Peña C

    更新日期:2011-10-01 00:00:00