Functional and molecular structural analysis of dentine interfaces promoted by a Zn-doped self-etching adhesive and an in vitro load cycling model.

Abstract:

:The aim of this study was to evaluate if mechanical cycling influences bioactivity and bond strength of resin-dentine interface after bonding with Zn-doped self-etching adhesives. Sound dentine surfaces were bonded with Clearfil SE Bond (SEB), 10 wt% ZnO microparticles or 2 wt% ZnCl2 were added into the SEB primer (P) or bonding (Bd) for Zn-doping. Bonded interfaces were stored in simulated body fluid (24h), and then tested or submitted to mechanical loading. Microtensile bond strength testing was performed. Debonded dentine surfaces were studied by scanning electron microscopy. Remineralisation of the bonded interfaces was assessed by nano-indentation, Raman spectroscopy, and Masson׳s trichrome staining. Load cycling (LC) increased the percentage of adhesive failures in all groups. LC increased the Young׳s modulus (Ei) at the hybrid layer (HL) when SEB, SEB·P-ZnO and SEB·P-ZnCl2 were applied, but decreased when both ZnO and ZnCl2 were incorporated into the bonding. Ei was higher when Zn compounds were incorporated into the primer (SEB·P). ZnO promoted an increase, and ZnCl2 a decrease, of both the relative presence of minerals and crystallinity, after LC. LC increased collagen crosslinking with both SEB·P-ZnO and SEB·P-ZnCl2. The ratios which reflect the nature of collagen increased, in general, at both HL and BHL after LC, confirming recovery, better organisation, improved structural differences and collagen quality. After loading, trichrome staining reflected a deeper demineralised dentine fringe when Zn-doped compounds were incorporated into SEB·Bd. Multiple Zn-rich phosphate deposits and salt formations were detected. Mineral precipitates nucleated in multilayered platforms or globular formations on peritubular and intertubular dentine.

authors

Toledano M,Aguilera FS,Osorio E,Cabello I,Toledano-Osorio M,Osorio R

doi

10.1016/j.jmbbm.2015.05.026

subject

Has Abstract

pub_date

2015-10-01 00:00:00

pages

131-49

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(15)00202-7

journal_volume

50

pub_type

杂志文章
  • Microstructure and mechanical properties of open-cellular biomaterials prototypes for total knee replacement implants fabricated by electron beam melting.

    abstract::Total knee replacement implants consisting of a Co-29Cr-6Mo alloy femoral component and a Ti-6Al-4V tibial component are the basis for the additive manufacturing of novel solid, mesh, and foam monoliths using electron beam melting (EBM). Ti-6Al-4V solid prototype microstructures were primarily α-phase acicular platele...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.05.010

    authors: Murr LE,Amato KN,Li SJ,Tian YX,Cheng XY,Gaytan SM,Martinez E,Shindo PW,Medina F,Wicker RB

    更新日期:2011-10-01 00:00:00

  • Finite element simulation for the mechanical characterization of soft biological materials by atomic force microscopy.

    abstract::The characterization of the mechanical properties of soft materials has been traditionally performed through uniaxial tensile tests. Nevertheless, this method cannot be applied to certain extremely soft materials, such as biological tissues or cells that cannot be properly subjected to these tests. Alternative non-des...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.006

    authors: Valero C,Navarro B,Navajas D,García-Aznar JM

    更新日期:2016-09-01 00:00:00

  • Resveratrol effect on osteogenic differentiation of rat and human adipose derived stem cells in a 3-D culture environment.

    abstract::The goal of this study was to investigate the effect of resveratrol treatment on the osteogenic potential of human and rat adipose derived stem cells in a 3-D culture environment. Adipose derived stem cells (ADSCs) have been widely studied and have shown promise as a potential source of osteogenic progenitor cells. Pr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.08.014

    authors: Dosier CR,Erdman CP,Park JH,Schwartz Z,Boyan BD,Guldberg RE

    更新日期:2012-07-01 00:00:00

  • Augmentation of core decompression with synthetic bone graft does not improve mechanical properties of the proximal femur.

    abstract::Core decompression is a minimally invasive surgical technique used to treat patients with avascular necrosis of the femoral head. The procedure requires an entry hole in the lateral cortex of the femur which potentially leaves patients susceptible to subtrochanteric fractures. The purpose of this study was to determin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104263

    authors: Hockett SA,Sherrill JT,Self M,Mears SC,Barnes CL,Mannen EM

    更新日期:2021-03-01 00:00:00

  • Characterization of persistent concussive syndrome using injury reconstruction and finite element modelling.

    abstract::Concussions occur 1.7 million times a year in North America, and account for approximately 75% of all traumatic brain injuries (TBI). Concussions usually cause transient symptoms but 10 to 20% of patients can have symptoms that persist longer than a month. The purpose of this research was to use reconstructions and fi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.034

    authors: Post A,Kendall M,Koncan D,Cournoyer J,Blaine Hoshizaki T,Gilchrist MD,Brien S,Cusimano MD,Marshall S

    更新日期:2015-01-01 00:00:00

  • Influence of biocorrosion on microstructure and mechanical properties of deformed Mg-Y-Er-Zn biomaterial containing 18R-LPSO phase.

    abstract::The microstructure and mechanical properties of as-extruded Mg-8Y-1Er-2Zn (wt%) alloy containing long period stacking ordered (LPSO) phase are comparatively investigated before and after corrosion in a simulated body fluid (SBF) at 37°C. The as-extruded alloy consists of a long strip-like 18R-LPSO phase and some fine ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.012

    authors: Leng Z,Zhang J,Yin T,Zhang L,Guo X,Peng Q,Zhang M,Wu R

    更新日期:2013-12-01 00:00:00

  • Wear characterization and contact surfaces analysis of menisci and femoral retrieved components in bi-condylar knee prostheses.

    abstract:PURPOSE:Although total knee arthroplasty is a well-practiced surgical procedure, material properties and surface topography can contribute to the wear mechanisms and the implant failure. It has been advised that an increased femoral component's surface roughness of total knee prostheses may be a contributing factor to ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103959

    authors: Affatato S,Ruzzi S,Milosevic M,Ruggiero A

    更新日期:2020-10-01 00:00:00

  • Adhesion failure behavior of sputtered calcium phosphate thin film coatings evaluated using microscratch testing.

    abstract::It is generally accepted that calcium phosphate (CaP) is one of the most important biomaterials in implant coating applications mainly because of its excellent bioactivity. However, its relatively poor mechanical properties limits its application. This entails that a better understanding of the mechanical properties o...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2010.01.002

    authors: Toque JA,Herliansyah MK,Hamdi M,Ide-Ektessabi A,Sopyan I

    更新日期:2010-05-01 00:00:00

  • Vancomycin elution, activity and impact on mechanical properties when added to orthopedic bone cement.

    abstract::Infection incidence for total hip and knee arthroplasty (THA and TKA, respectively) is between 0.2% and 5% and results in approximately 100,000 device failures per year in the United States. Treatment requires prolonged systemic antibiotic therapy with additional surgical revisions. As a prophylactic measure against i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.06.033

    authors: Bishop AR,Kim S,Squire MW,Rose WE,Ploeg HL

    更新日期:2018-11-01 00:00:00

  • Adhesion of ligand-conjugated biosynthesized magnetite nanoparticles to triple negative breast cancer cells.

    abstract::This paper presents the results of an experimental study of the adhesion forces between components of model conjugated magnetite nanoparticle systems for improved selectivity in the specific targeting of triple negative breast cancer. Adhesion forces between chemically synthesized magnetite nanoparticles (CMNPs), bios...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.02.004

    authors: Obayemi JD,Hu J,Uzonwanne VO,Odusanya OS,Malatesta K,Anuku N,Soboyejo WO

    更新日期:2017-04-01 00:00:00

  • Frequency-modulated atomic force microscopy localises viscoelastic remodelling in the ageing sheep aorta.

    abstract::Age-related aortic stiffening is associated with cardiovascular diseases such as heart failure. The mechanical functions of the main structural components of the aorta, such as collagen and elastin, are determined in part by their organisation at the micrometer length scale. With age and disease both components underg...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.07.018

    authors: Akhtar R,Graham HK,Derby B,Sherratt MJ,Trafford AW,Chadwick RS,Gavara N

    更新日期:2016-12-01 00:00:00

  • Reinforcement of conventional glass-ionomer restorative material with short glass fibers.

    abstract::This study investigated the strengthening effect of glass fibers when added to conventional glass-ionomer restorative material. Glass fibers were incorporated into glass-ionomer powder in 3 wt% and 5 wt%. The fibers used had 1 mm length and 10 microm thickness. These criteria of fiber length, diameter, and concentrati...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.04.002

    authors: Hammouda IM

    更新日期:2009-01-01 00:00:00

  • The nonlinear flexural response of a whole teleost fish: Contribution of scales and skin.

    abstract::The scaled skin of fish is an intricate system that provides mechanical protection against hard and sharp puncture, while maintaining the high flexural compliance required for unhindered locomotion. This unusual combination of local hardness and global compliance makes fish skin an interesting model for bioinspired pr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.06.014

    authors: Szewciw L,Zhu D,Barthelat F

    更新日期:2017-12-01 00:00:00

  • Influence of the fabrication process and fluoride content on the tribocorrosion behaviour of Ti6Al4V biomedical alloy in artificial saliva.

    abstract::Titanium and its alloys are widely used as dental implants due to their low density, excellent biocompatibility, mechanical properties and corrosion resistance. However, during their lifetime Ti6Al4V biomedical alloys are subjected to different mechanical actions (i.e., sliding or fretting), thus resulting in a triboc...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.01.019

    authors: Licausi MP,Igual Muñoz A,Amigó Borrás V

    更新日期:2013-04-01 00:00:00

  • Solute lean Ti-Nb-Fe alloys: An exploratory study.

    abstract::In this study, we explored the Ti-Nb-Fe system to find an optimal cost-effective composition with the lowest elastic modulus and the lowest added Nb content. Six Ti-(31-4x)Nb-(1+0.5x)Fe ingots were prepared and Nb was substituted with Fe, starting at Ti-31Nb-1.0Fe and going up to Ti-11Nb-3.5Fe (wt%). The ingots were s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.09.024

    authors: Salvador CAF,Dal Bó MR,Costa FH,Taipina MO,Lopes ESN,Caram R

    更新日期:2017-01-01 00:00:00

  • Numerical modeling of bone as a multiscale poroelastic material by the homogenization technique.

    abstract::Bone is a complex material showing a hierarchical and porous structure but also a natural ability to remodel thanks to cells sensitive to fluid flows. Based on these characteristics, a multiscale numerical model has been developed in order to represent the bone response under mechanical solicitation. It relies on the ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.12.015

    authors: Perrin E,Bou-Saïd B,Massi F

    更新日期:2019-03-01 00:00:00

  • A method and a device for the evaluation of the retention of telescopic dental crowns.

    abstract::Telescopic crowns are used as support for removable dental prostheses' construction. A distinctive feature of crowns often used in their description and comparison is retention, which is understood as resistance when removing the prosthesis or a force needed to disconnect crowns. The article describes a method for the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.01.042

    authors: Majcher A,Leśniewska-Kochanek A,Mierzwińska-Nastalska E

    更新日期:2017-05-01 00:00:00

  • Mechanical characterization and modelling of the temperature-dependent impact behaviour of a biocompatible poly(L-lactide)/poly(ε-caprolactone) polymer blend.

    abstract::Poly(ε-caprolactone) (PCL) is a ductile, bioabsorbable polymer that has been employed as a blend partner for poly(L-lactic acid) (PLLA). An improvement of the material strength and impact resistance of PLLA/PCL polymer blends compared to pure PLLA has been shown previously. To use numerical simulations in the design p...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.07.007

    authors: Gustafsson G,Nishida M,Ito Y,Häggblad HÅ,Jonsén P,Takayama T,Todo M

    更新日期:2015-11-01 00:00:00

  • Nanomechanical properties of human skin and introduction of a novel hair indenter.

    abstract::The mechanical resistance of the stratum corneum, the outermost layer of skin, to deformation has been evaluated at different length scales using Atomic Force Microscopy. Nanomechanical surface mapping was first conducted using a sharp silicon tip and revealed that Young׳s modulus of the stratum corneum varied over th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.09.014

    authors: Álvarez-Asencio R,Wallqvist V,Kjellin M,Rutland MW,Camacho A,Nordgren N,Luengo GS

    更新日期:2016-02-01 00:00:00

  • Extrusion of the biodegradable ZnMg0.8Ca0.2 alloy - The influence of extrusion parameters on microstructure and mechanical characteristics.

    abstract::The Zn-based alloys, alloyed with the elements of the 2nd group of the periodic table, are considered as potential biodegradable materials suitable for the fabrication of small orthopaedic implants or cardiovascular stents. Unfortunately, the as-cast Zn-based alloys do not fulfil the requirements for mechanical proper...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103796

    authors: Čapek J,Kubásek J,Pinc J,Drahokoupil J,Čavojský M,Vojtěch D

    更新日期:2020-08-01 00:00:00

  • Effect of cell sample size in atomic force microscopy nanoindentation.

    abstract::Single-cell technologies are powerful tools to evaluate cell characteristics. In particular, Atomic Force Microscopy (AFM) nanoindentation experiments have been widely used to study single cell mechanical properties. One important aspect related to single cell techniques is the need for sufficient statistical power to...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.018

    authors: Marcotti S,Reilly GC,Lacroix D

    更新日期:2019-06-01 00:00:00

  • A new constitutive model for simulation of softening, plateau, and densification phenomena for trabecular bone under compression.

    abstract::A new type of constitutive model and its computational implementation procedure for the simulation of a trabecular bone are proposed in the present study. A yield surface-independent Frank-Brockman elasto-viscoplastic model is introduced to express the nonlinear material behavior such as softening beyond yield point, ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.08.028

    authors: Lee CS,Lee JM,Youn B,Kim HS,Shin JK,Goh TS,Lee JS

    更新日期:2017-01-01 00:00:00

  • Through-thickness stress relaxation in bacterial cellulose hydrogel.

    abstract::Biological hydrogels, e.g. bacterial cellulose (BC) hydrogel, attracted increasing interest in recent decades since they show a good potential for biomedical engineering as replacements of real tissues thanks mainly to their good biocompatibility and fibrous structure. To select potential candidates for such applicati...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.021

    authors: Gao X,Kuśmierczyk P,Shi Z,Liu C,Yang G,Sevostianov I,Silberschmidt VV

    更新日期:2016-06-01 00:00:00

  • Biomechanical test protocols to detect minor injury effects in intervertebral discs.

    abstract::Intervertebral discs (IVDs) maintain flexibility of the spine and bear mechanical load. Annulus fibrosus (AF) defects are associated with IVD degeneration and herniation which disrupt biomechanical function and can cause pain. AF puncture injuries can induce IVD degeneration but are needed to inject therapies. Identif...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.024

    authors: Torre OM,Evashwick-Rogler TW,Nasser P,Iatridis JC

    更新日期:2019-07-01 00:00:00

  • Effect of phytic acid etchant on the structural stability of demineralized dentine and dentine bonding.

    abstract:OBJECTIVE:This study examined the effect of phytic acid (IP6) in stabilizing the morphology of dentine collagen network and resin-dentine bonding. METHODS:Dentine beams were fully demineralized with 10% phosphoric acid (PA) or 1% IP6 (pH 1.2). PA-demineralized beams were divided into three groups: (a) no further treat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.027

    authors: Kong K,Islam MS,Nassar M,Hiraishi N,Otsuki M,Yiu CKY,Tagami J

    更新日期:2015-08-01 00:00:00

  • Evaluation of experimental, analytical, and computational methods to determine long-bone bending stiffness.

    abstract::Methods used to evaluate bone mechanical properties vary widely depending on the motivation and environment of individual researchers, clinicians, and industries. Further, the innate complexity of bone makes validation of each method difficult. Thus, the purpose of the present research was to quantify methodological e...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104253

    authors: Collins CJ,Yang B,Crenshaw TD,Ploeg HL

    更新日期:2021-03-01 00:00:00

  • Effect of size and dimensional tolerance of reverse total shoulder arthroplasty on wear: An in-silico study.

    abstract::Although huge research efforts have been devoted to wear analysis of ultra-high molecular weight polyethylene (UHMWPE) in hip and knee implants, shoulder prostheses have been studied only marginally. Recently, the authors presented a numerical wear model of reverse total shoulder arthroplasties (RTSAs), and its applic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.033

    authors: Mattei L,Di Puccio F,Joyce TJ,Ciulli E

    更新日期:2016-08-01 00:00:00

  • FT-Raman spectroscopic study of human skin subjected to uniaxial stress.

    abstract::Fourier Transform Raman Spectroscopy was used to investigate the molecular changes of structural proteins in human skin subjected to strain. In the Raman spectrum of unstrained skin, bands assigned mainly to collagen and elastin were observed at 1658 cm(-1) (amide I), 1271 and 1255 cm(-1) (amide III), and 935 and 817 ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.11.023

    authors: Gąsior-Głogowska M,Komorowska M,Hanuza J,Mączka M,Zając A,Ptak M,Będziński R,Kobielarz M,Maksymowicz K,Kuropka P,Szotek S

    更新日期:2013-02-01 00:00:00

  • Simulating damage onset and evolution in fully bio-resorbable composite under three-point bending.

    abstract::This paper presents a strain-based damage model to predict the stress-strain relationship and investigate the damage onset and evolution of the fibre and matrix of a fully bio-resorbable phosphate glass fibre reinforced composite under three-point bending. The flexural properties of the composite are crucial, particul...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.02.022

    authors: Gao X,Chen M,Yang X,Harper L,Ahmed I,Lu J

    更新日期:2018-05-01 00:00:00

  • Environmental fatigue of superelastic NiTi wire with two surface finishes.

    abstract::Surface finish of NiTi is widely perceived to affect its biocompatibility and corrosion fatigue performance. The aim of this work was to find out, whether a carefully engineered surface oxide shows any beneficial effect over electropolished surface on the fatigue performance of superelastic NiTi wire mechanically cycl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104028

    authors: Racek J,Šittner P

    更新日期:2020-11-01 00:00:00