RETRACTED: Mechanical properties and phase transition of biomedical titanium alloy strips with initial quasi-single phase state under high-energy electropulses.

Abstract:

:This article has been retracted: please see Elsevier Policy on Article Withdrawal (http://www.elsevier.com/locate/withdrawalpolicy). This article has been retracted at the request of the Editor-in-Chief. The authors have reused figures and text that have already appeared in their previous articles. Figure 4 duplicates figure 4 in Reference [1], figure 6 in Reference [2], figure 8 in Reference [3] and figure 4 in Reference [4], while Figure 7a-b duplicates figure 7a-b in Reference [4]. The article also duplicates significant parts of the text that appeared in References [1] and [4]. One of the conditions of submission of a paper for publication is that authors declare explicitly that their work is original and has not appeared in a publication elsewhere. As such this article represents an abuse of the scientific publishing system. The scientific community takes a very strong view on this matter and apologies are offered to readers of the journal that this was not detected during the submission process. Journal records indicate that confirmation of the submission and publication of the article was sent to the first author’s email address but not to the corresponding author's email address. The corresponding author and the first author wish to mention that the co-author Zion T.H. Tse was not involved in the preparation and handling of this article. He was not informed about the publication nor granted the use of his name and affiliation in the publication. References [1] J Mater Res 30 (2015) 206-223, http://dx.doi.org/10.1557/jmr.2014.367. [2] Mat Sci Eng A 622 (2015) 1-6, http://dx.doi.org/10.1016/j.msea.2014.11.003. [3] J Mater Res 29 (2014) 1500-1512, http://dx.doi.org/10.1557/jmr.2014.171. [4] Adv Eng Mater 17 (2015) 995-1007, http://dx.doi.org/10.1002/adem.201400273.

authors

Ye X,Tse ZT,Tang G,Song G

doi

10.1016/j.jmbbm.2014.11.009

subject

Has Abstract

pub_date

2015-02-01 00:00:00

pages

100-15

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(14)00361-0

journal_volume

42

pub_type

杂志文章,收录出版
  • Influence of strain rate on the mechanical behavior of dry and hydrated chitosan-based dense materials for bioabsorbable implant applications.

    abstract::Chitosan has generated enormous interest in the scientific community because of its distinctive biological and physicochemical properties, which allow new advanced structures and applications. Porous chitosan scaffolds have been extensively studied and explored in bone generation, however it is still a challenge to ob...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2021.104337

    authors: Figueiredo L,Gregório AVL,Rodrigues A,Rosa PAR

    更新日期:2021-01-21 00:00:00

  • Identification of biomechanical properties in vivo in human uterine cervix.

    abstract:BACKGROUND AND AIMS:The course and outcome of pregnancy is closely correlated to change of biomechanical properties of the uterine cervix. The aim of this study was to build a non-linear, fiber reinforced mechanical model of the cervix for estimation of mechanical characteristics of the cervix in early- and term-pregna...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.005

    authors: Liao D,Hee L,Sandager P,Uldbjerg N,Gregersen H

    更新日期:2014-11-01 00:00:00

  • Effect of Cu on microstructure, mechanical properties, corrosion resistance and cytotoxicity of CoCrW alloy fabricated by selective laser melting.

    abstract::In the study, CoCrWCu alloys with differing Cu content (2, 3, 4 wt%) were prepared by selective laser melting using mixture powders consisting of CoCrW and Cu, aiming at investigating the effect of Cu on the microstructures, mechanical properties, corrosion behavior and cytotoxicity. The SEM observations indicated tha...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.02.026

    authors: Lu Y,Ren L,Xu X,Yang Y,Wu S,Luo J,Yang M,Liu L,Zhuang D,Yang K,Lin J

    更新日期:2018-05-01 00:00:00

  • Study of indentation of a sample equine bone using finite element simulation and single cycle reference point indentation.

    abstract::In an attempt to study the mechanical behavior of bone under indentation, methods of analyses and experimental validations have been developed, with a selected test material. The test material chosen is from an equine cortical bone. Stress-strain relationships are first obtained from conventional mechanical property t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.11.020

    authors: Hoffseth K,Randall C,Hansma P,Yang HT

    更新日期:2015-02-01 00:00:00

  • Biorelevant polyanions stabilize fibrin against mechanical and proteolytic decomposition: Effects of polymer size and electric charge.

    abstract::The release of neutrophil extracellular traps (NETs) containing DNA and histones is an essential mechanism in the neutrophil-mediated innate immunity. In thrombi the polyanionic DNA confers mechanical and lytic resistance to fibrin and heparins interfere with the effects of NET components. Heparins are polyanions used...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103459

    authors: Komorowicz E,Balázs N,Tanka-Salamon A,Varga Z,Szabó L,Bóta A,Longstaff C,Kolev K

    更新日期:2020-02-01 00:00:00

  • Effects of homogenization technique and introduction of interfaces in a multiscale approach to predict the elastic properties of arthropod cuticle.

    abstract::In this paper the mechanical response of the arthropod cuticle is evaluated by means of a multiscale approach including interface effects. The cuticle's elastic behavior is modeled at the nano and the micro scales by mean-field homogenization techniques. With respect to the work of Nikolov et al. (2011), the idea has ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.04.003

    authors: Lhadi S,Ahzi S,Rémond Y,Nikolov S,Fabritius H

    更新日期:2013-07-01 00:00:00

  • Mechano-rheological properties of the murine thrombus determined via nanoindentation and finite element modeling.

    abstract::Deep vein thrombosis, pulmonary embolism, and abdominal aortic aneurysms are blood-related diseases that represent a major public health problem. These diseases are characterized by the formation of a thrombus (i.e., blood clot) that either blocks a major artery or causes an aortic rupture. Identifying the mechanical ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.02.012

    authors: Slaboch CL,Alber MS,Rosen ED,Ovaert TC

    更新日期:2012-06-01 00:00:00

  • Correlations between transmural mechanical and morphological properties in porcine thoracic descending aorta.

    abstract::Determination of correlations between transmural mechanical and morphological properties of aorta would provide a quantitative baseline for assessment of preventive and therapeutic strategies for aortic injuries and diseases. A multimodal and multidisciplinary approach was adopted to characterize the transmural morpho...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.004

    authors: Hemmasizadeh A,Tsamis A,Cheheltani R,Assari S,D'Amore A,Autieri M,Kiani MF,Pleshko N,Wagner WR,Watkins SC,Vorp D,Darvish K

    更新日期:2015-07-01 00:00:00

  • Combination of a biodegradable three-dimensional (3D) - printed cage for mechanical support and nanofibrous membranes for sustainable release of antimicrobial agents for treating the femoral metaphyseal comminuted fracture.

    abstract::The aim of this study was to develop a biodegradable three-dimensional-printed polylactide (PLA) cage for promoting bony fixation and an antibiotics-embedded poly(d,l)-lactide-co-glycolide (PLGA) nanofibrous membrane for infectious prophylaxis during treating the comminuted metaphyseal fracture in a rabbit femoral mod...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.05.002

    authors: Chou YC,Lee D,Chang TM,Hsu YH,Yu YH,Chan EC,Liu SJ

    更新日期:2017-08-01 00:00:00

  • Alternative processing methods of hybrid porous scaffolds based on gelatin and chitosan.

    abstract::The present work focuses on the development of scaffolds based on gelatin and chitosan using different protocols based on the general processing of phase separation, derived from the fabrication of hydrogels and freeze-drying. The scaffolds were produced with 1 wt% of two different biopolymers, i.e. gelatin (GE) and c...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103472

    authors: Perez-Puyana V,Rubio-Valle JF,Jiménez-Rosado M,Guerrero A,Romero A

    更新日期:2020-02-01 00:00:00

  • Cytocompatibility, mechanical and dissolution properties of high strength boron and iron oxide phosphate glass fibre reinforced bioresorbable composites.

    abstract::In this study, Polylactic acid (PLA)/phosphate glass fibres (PGF) composites were prepared by compression moulding. Fibres produced from phosphate based glasses P2O5-CaO-MgO-Na2O (P45B0), P2O5-CaO-MgO-Na2O-B2O3 (P45B5), P2O5-CaO-MgO-Na2O-Fe2O3 (P45Fe3) and P2O5-CaO-MgO-Na2O-B2O3-Fe2O3 (P45B5Fe3) were used to reinforce...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.011

    authors: Sharmin N,Hasan MS,Parsons AJ,Rudd CD,Ahmed I

    更新日期:2016-06-01 00:00:00

  • On collagen fiber morphoelasticity and homeostatic remodeling tone.

    abstract::A variety of biochemical and physical processes participate in the creation and maintenance of collagen in biological tissue. Under mechanical stimuli these collagen fibers undergo continuous processes of morphoelastic change. The model presented here is motivated by experimental reports of stretch-stabilization of th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104154

    authors: Topol H,Demirkoparan H,Pence TJ

    更新日期:2021-01-01 00:00:00

  • Layer-specific residual deformations and uniaxial and biaxial mechanical properties of thoracic porcine aorta.

    abstract::In this paper we hypothesize that the layer-separated residual stresses and mechanical properties of layer-separated thoracic aorta arteries may be dependent on arterial location of the vessel. To demonstrate any possible position differences, we measured the axial pre-stretch and opening angle and performed uniaxial ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.024

    authors: Peña JA,Martínez MA,Peña E

    更新日期:2015-10-01 00:00:00

  • Custom-built electrostatics and supplementary bonding in the design of reinforced Collagen-g-P(methyl methacrylate-co-ethyl acrylate)/ nylon 66 core-shell fibers.

    abstract::In this study, Acid Soluble Collagen-g-P(methyl methacrylate-co-ethyl acrylate) (CME) was synthesized to take advantage of the flexibility of the resulted branched polymer chains and the high density of their chain entanglement. The coaxial electrospinning technique was applied to study the effect of electrically and ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.002

    authors: Bazrafshan Z,Stylios GK

    更新日期:2018-11-01 00:00:00

  • Mechano-geometrical skeletal muscle fibre characterisation under cyclic and relaxation loading.

    abstract::In the present work, mechano-geometrical characterisations of skeletal muscle fibres in two different deformation states, namely, axial tension and axial compression, were realised. In both cases, cyclic and relaxation tests were performed. Additionally, the changes in the volume of the fibres during deformation were ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104001

    authors: Böl M,Iyer R,Garcés-Schröder M,Kohn S,Dietzel A

    更新日期:2020-10-01 00:00:00

  • Surface integrity and corrosion performance of biomedical magnesium-calcium alloy processed by hybrid dry cutting-finish burnishing.

    abstract::Biodegradable magnesium-calcium (MgCa) alloy is a very attractive orthopedic biomaterial compared to permanent metallic alloys. However, the critical issue is that MgCa alloy corrodes too fast in the human organism. Compared to dry cutting, the synergistic dry cutting-finish burnishing can significantly improve corros...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.026

    authors: Salahshoor M,Li C,Liu ZY,Fang XY,Guo YB

    更新日期:2018-02-01 00:00:00

  • Translucency, hardness and strength parameters of PMMA resin containing graphene-like material for CAD/CAM restorations.

    abstract::CAD/CAM restorations can be produced from several ceramic and hybrid materials. The moderate mechanical properties of PMMA based resin have hindered its use for permanent restorations. Recently, a graphene reinforced PMMA namely G-CAM has been introduced for permanent CAD/CAM restorations. Although graphene family mat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103388

    authors: Agarwalla SV,Malhotra R,Rosa V

    更新日期:2019-12-01 00:00:00

  • Thickness optimization of auricular silicone scaffold based on finite element analysis.

    abstract::An optimized thickness of a transplantable auricular silicone scaffold was researched. The original image data were acquired from CT scans, and reverse modeling technology was used to build a digital 3D model of an auricle. The transplant process was simulated in ANSYS Workbench by finite element analysis (FEA), solid...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.08.032

    authors: Jiang T,Shang J,Tang L,Wang Z

    更新日期:2016-01-01 00:00:00

  • Fracture resistance of CAD/CAM occlusal veneers: A systematic review of laboratory studies.

    abstract:OBJECTIVE:The purpose of this systematic review was to summarize scientific evidence that evaluates in vitro fracture and fatigue strength of occlusal veneers in different thicknesses, CAD/CAM materials, and under different aging methodologies. MATERIALS AND METHODS:An electronic search of 3 English databases (The Nat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,评审

    doi:10.1016/j.jmbbm.2020.103948

    authors: Albelasy EH,Hamama HH,Tsoi JKH,Mahmoud SH

    更新日期:2020-10-01 00:00:00

  • Influence of the overall stiffness of a load-bearing porous titanium implant on bone ingrowth in critical-size mandibular bone defects in sheep.

    abstract::The aim of this work was to assess the influence of reduction of the apparent mechanical properties of fully load-bearing porous titanium implants used in mandibular bone defects. Segmental 18mm long bone defects were created bilaterally in the lower jaws of adult ewes. One group of 6 ewes (group A) was treated with l...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.02.036

    authors: Schouman T,Schmitt M,Adam C,Dubois G,Rouch P

    更新日期:2016-06-01 00:00:00

  • Increased stiffness of collagen fibrils following cyclic tensile loading.

    abstract::Alterations in mechanical loading can induce growth and remodeling in soft connective tissues. Numerous studies have measured changes in the collagen structure and mechanical properties of cellularized native and engineered tissues in response to cyclic mechanical loading. However, a recent experimental study demonstr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.03.027

    authors: Chen ML,Ruberti JW,Nguyen TD

    更新日期:2018-06-01 00:00:00

  • A study of extracellular matrix remodeling in aortic heart valves using a novel biaxial stretch bioreactor.

    abstract::In aortic valves, biaxial cyclic stretch is known to modulate cell differentiation, extracellular matrix (ECM) synthesis and organization. We designed a novel bioreactor that can apply independent and precise stretch along radial and circumferential directions in a tissue culture environment. While this bioreactor can...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.041

    authors: Lei Y,Masjedi S,Ferdous Z

    更新日期:2017-11-01 00:00:00

  • A study of friction mechanisms between a surrogate skin (Lorica soft) and nonwoven fabrics.

    abstract::Hygiene products such as incontinence pads bring nonwoven fabrics into contact with users' skin, which can cause damage in various ways, including the nonwoven abrading the skin by friction. The aim of the work described here was to develop and use methods for understanding the origin of friction between nonwoven fabr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.04.024

    authors: Cottenden DJ,Cottenden AM

    更新日期:2013-12-01 00:00:00

  • The functions of hydrophobic elastic polyurethane combined with an antibacterial triclosan derivative in the dentin restoration interface.

    abstract::Dentin restoration produces weak interfaces because of the effects of bacterial microflora, biofilms, and mechanical, thermal, and shrinkage stresses. This results in secondary caries. Therefore, hydrophobic elastic polyurethane (PU) containing different concentrations of triclosan derivatives was synthesized and appl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103471

    authors: Guo X,Cheng Q,Yu G,Wang H,Tian Z,Shi Z,Cui Z,Zhu S

    更新日期:2020-02-01 00:00:00

  • Bioactive composite for keratoprosthesis skirt.

    abstract::In this study, the fabrication and properties of a synthetic keratoprosthesis skirt for use in osteo-odonto-keratoprosthesis (OOKP) surgery are discussed. In the search for a new material concept, bioactive glass and polymethyl methacrylate (PMMA)-based composites were prepared. Three different bioactive glasses (i.e....

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.05.025

    authors: Laattala K,Huhtinen R,Puska M,Arstila H,Hupa L,Kellomäki M,Vallittu PK

    更新日期:2011-11-01 00:00:00

  • Unusual effect evidenced at the investigations of the mechanical behavior of composite hydrogels under cyclic compression.

    abstract::An unusual type of mechanical behavior was registered while studying the swollen hydrogel compositions "cellulose-polyacrylamide" in the conditions of multiple cyclic compression tests with the broad variation of the deformation speed. While increasing the deformation rate the clearly seen inversion of the positions o...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.03.030

    authors: Gofman IV,Buyanov AL

    更新日期:2017-07-01 00:00:00

  • Air-abrasion using new silica-alumina powders containing different silica concentrations: Effect on the microstructural characteristics and fatigue behavior of a Y-TZP ceramic.

    abstract::This study assessed the fatigue performance (biaxial flexure fatigue strength), surface characteristics (topography and roughness) and structural stability (t-m phase transformation) of a Y-TZP ceramic subjected to air-abrasion using new powders (7% and 20% silica-coated aluminum oxide particles) in comparison to comm...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.05.032

    authors: Cadore-Rodrigues AC,Prochnow C,Rippe MP,Oliveira JS,Jahn SL,Foletto EL,Pereira GKR,Valandro LF

    更新日期:2019-10-01 00:00:00

  • Surface protection in bio-shields via a functional soft skin layer: Lessons from the turtle shell.

    abstract::The turtle shell is a functional bio-shielding element, which has evolved naturally to provide protection against predator attacks that involve biting and clawing. The near-surface architecture of the turtle shell includes a soft bi-layer skin coating - rather than a hard exterior - which functions as a first line of ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.01.019

    authors: Shelef Y,Bar-On B

    更新日期:2017-09-01 00:00:00

  • Enhancement of the mechanical properties of AZ31 magnesium alloy via nanostructured hydroxyapatite thin films fabricated via radio-frequency magnetron sputtering.

    abstract::The structure, composition and morphology of a radio-frequency (RF) magnetron sputter-deposited dense nano-hydroxyapatite (HA) coating that was deposited on the surface of an AZ31 magnesium alloy were characterized using AFM, SEM, EDX and XRD. The results obtained from SEM and XRD experiments revealed that the bias ap...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.02.025

    authors: Surmeneva MA,Tyurin AI,Mukhametkaliyev TM,Pirozhkova TS,Shuvarin IA,Syrtanov MS,Surmenev RA

    更新日期:2015-06-01 00:00:00

  • Molecular dynamics simulation of mechanical behavior of osteopontin-hydroxyapatite interfaces.

    abstract::Bone is characterized with an optimized combination of high stiffness and toughness. The understanding of bone nanomechanics is critical to the development of new artificial biological materials with unique properties. In this work, the mechanical characteristics of the interfaces between osteopontin (OPN, a noncollag...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.04.002

    authors: Lai ZB,Wang M,Yan C,Oloyede A

    更新日期:2014-08-01 00:00:00