Wear characterization and contact surfaces analysis of menisci and femoral retrieved components in bi-condylar knee prostheses.

Abstract:

PURPOSE:Although total knee arthroplasty is a well-practiced surgical procedure, material properties and surface topography can contribute to the wear mechanisms and the implant failure. It has been advised that an increased femoral component's surface roughness of total knee prostheses may be a contributing factor to accelerated wear of the polyethylene menisci and eventually prosthesis failure. The aim of this study is to investigate the wear phenomena occurring on medial and lateral compartments of retrieved total knee arthroplasty in order to correlate the surface roughness vs. BMI, age at revision, and time in situ. METHODS:Qualitative visual analyses were performed on all the retrieved knee components to assess the damage due to the wear phenomena. Quantitative analysis includes surface characterization performed using optical apparatus to describe surface roughness and morphology on the retrieved femoral, tibial and polyethylene component. The Mann-Whitney statistical test was performed to correlate the medial vs. lateral condyle surface roughness of all explants with BMI, age at revision, and time in situ. RESULTS:Visual and topographical analysis showed damage along the entire zone of the sliding contact area. A statistical difference between medial and lateral condyle roughness was found on four prosthesis. No statistical significance was found between surface roughness measurements and patient BMI, age at revision, and time in situ. On the femoral components various scratches were observed in the anterior/posterior (AP) direction of all the fixed femoral components. A statistically significant difference between medial and lateral condyle was found on two mobile knee design (p = 0.03) and on two fixed design (p = 0.01). The results were discussed in the framework of the usual TKR loading conditions during the gait, and of knowledge on the bio-tribological behavior of the prosthetic joint. CONCLUSIONS:The visual and topographical analysis showed consistent damage patterns with respect to the main movements to which the prosthetic components are subjected and no statistical significance was found between surface roughness measurements and patient BMI, age at revision, and time in situ.

authors

Affatato S,Ruzzi S,Milosevic M,Ruggiero A

doi

10.1016/j.jmbbm.2020.103959

subject

Has Abstract

pub_date

2020-10-01 00:00:00

pages

103959

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(20)30512-9

journal_volume

110

pub_type

杂志文章
  • Effect of fluorine substitution on sintering behaviour, mechanical and bioactivity of hydroxyapatite.

    abstract::Fluorine substituted hydroxyapatite (FAp) with different degree of fluorine (F) substitution, has been synthesized using hydrothermal synthesis method. In the present work, as synthesized powders were consolidated by sintering at 1200 °C in air for 1 h. The sintered specimens were characterized using Fourier transform...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.032

    authors: Nasker P,Samanta A,Rudra S,Sinha A,Mukhopadhyay AK,Das M

    更新日期:2019-07-01 00:00:00

  • Characterization, mechanical properties and corrosion resistance of biocompatible Zn-HA/TiO2 nanocomposite coatings.

    abstract::Biocompatible Zinc-hydroxyapatite-titania and Zinc-hydroxyapatite nanocomposite coatings have been prepared by electrodeposition on NiTi shape memory alloy. Structures of coatings were characterized using X-ray diffraction (XRD). It was found that addition of TiO2 particles cause to reduction of crystallite size of co...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.016

    authors: Mirak M,Alizadeh M,Ghaffari M,Ashtiani MN

    更新日期:2016-09-01 00:00:00

  • A study of extracellular matrix remodeling in aortic heart valves using a novel biaxial stretch bioreactor.

    abstract::In aortic valves, biaxial cyclic stretch is known to modulate cell differentiation, extracellular matrix (ECM) synthesis and organization. We designed a novel bioreactor that can apply independent and precise stretch along radial and circumferential directions in a tissue culture environment. While this bioreactor can...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.041

    authors: Lei Y,Masjedi S,Ferdous Z

    更新日期:2017-11-01 00:00:00

  • Mechanical properties and electrochemical behavior of porous Ti-Nb biomaterials.

    abstract::Ti-Nb-based alloys - with their superior mechanical properties and biocompatibility - are attractive biomaterials for orthopedic implants. By producing this alloys with a porous structure, it is possible to achieve mechanical properties similar to that of bone and to facilitate cellular activities. In this study, Ti16...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.018

    authors: Yılmaz E,Gökçe A,Findik F,Gulsoy HO,İyibilgin O

    更新日期:2018-11-01 00:00:00

  • On the effect of calcification volume and configuration on the mechanical behaviour of carotid plaque tissue.

    abstract::Vascular calcification is a complex molecular process that exhibits a number of relatively characteristic morphology patterns in atherosclerotic plaques. Treatment of arterial stenosis by endovascular intervention, involving forceful circumferential expansion of the plaque, can be unpredictable in calcified lesions. T...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.11.001

    authors: Barrett HE,Cunnane EM,Kavanagh EG,Walsh MT

    更新日期:2016-03-01 00:00:00

  • Experimental study on dieless drawing of Nickel-Titanium alloy.

    abstract::The effect of a dieless drawing process on commercial grade Nickel-Titanium rods, of 5 mm diameter, was investigated by varying the established critical process parameters of temperature, cooling rate, drawing velocity, and heating/cooling velocity. The rods were successfully dieless drawn with a maximum steady state ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.12.013

    authors: Twohig E,Tiernan P,Tofail SA

    更新日期:2012-04-01 00:00:00

  • Effect of hydroxyapatite fillers on the mechanical properties and osteogenesis capacity of bio-based polyurethane composite scaffolds.

    abstract::A newly designed hydroxyapatite-polyurethane (HA-PU) composite scaffold was prepared by polymerizing glyceride of castor oil (GCO) with isophorone diisocyanate (IPDI) and HA as fillers. The aim of this study was to determine the effect of HA fillers on the mechanical properties and osteogenesis capacity of the composi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.08.028

    authors: Du J,Zuo Y,Lin L,Huang D,Niu L,Wei Y,Wang K,Lin Q,Zou Q,Li Y

    更新日期:2018-12-01 00:00:00

  • Load-bearing capacities of ultra-thin occlusal veneers bonded to dentin.

    abstract:OBJECTIVES:To test whether the load-bearing capacity of occlusal veneers made of ceramic or hybrid materials bonded to dentin does differ from those of porcelain-fused-to metal or lithium disilicate glass ceramic crowns. MATERIAL AND METHODS:In 80 human molars, occlusal tooth substance was removed so that the defects ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.04.006

    authors: Maeder M,Pasic P,Ender A,Özcan M,Benic GI,Ioannidis A

    更新日期:2019-07-01 00:00:00

  • Microstructure, mechanical and wear properties of laser surface melted Ti6Al4V alloy.

    abstract::Laser surface melting (LSM) of Ti6Al4V alloy was carried out with an aim to improve properties such as microstructure and wear for implant applications. The alloy substrate was melted at 250W and 400W at a scan velocity of 5mm/s, with input energy of 42J/mm(2) and 68J/mm(2), respectively. The results showed that equia...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.12.001

    authors: Balla VK,Soderlind J,Bose S,Bandyopadhyay A

    更新日期:2014-04-01 00:00:00

  • Structural analysis of rat bone explants kept in vitro in simulated microgravity conditions.

    abstract::Skeletal abnormalities reported in humans and laboratory animals after spaceflight, include cancellous osteopenia, decreased cortical and cancellous bone formation, aberrant matrix ultrastructure, decreased mineralization and reduced bone strength. Although considerable effort has been made up to now to understand the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.06.004

    authors: Cosmi F,Steimberg N,Dreossi D,Mazzoleni G

    更新日期:2009-04-01 00:00:00

  • Biocomposite scaffolds for bone regeneration: Role of chitosan and hydroxyapatite within poly-3-hydroxybutyrate-co-3-hydroxyvalerate on mechanical properties and in vitro evaluation.

    abstract::Bio-engineered scaffolds for bone tissue regeneration is an exploding area of research mainly because they can satisfy the essential demands and current challenges in bone replacement therapies, by imitating the extracellular matrix (ECM) of the native bone. We fabricated bio-composite nanofibrous scaffolds with a ble...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.06.032

    authors: Zhang S,Prabhakaran MP,Qin X,Ramakrishna S

    更新日期:2015-11-01 00:00:00

  • Fatigue and durability of Nitinol stents.

    abstract::Nitinol self-expanding stents are effective in treating peripheral artery disease, including the superficial femoral, carotid, and renal arteries. However, fracture occurrences of up to 50% have been reported in some stents after one year. These stent fractures are likely due to in vivo cyclic displacements. As such, ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2007.08.001

    authors: Pelton AR,Schroeder V,Mitchell MR,Gong XY,Barney M,Robertson SW

    更新日期:2008-04-01 00:00:00

  • Zn-doping of silicate and hydroxyapatite-based cements: Dentin mechanobiology and bioactivity.

    abstract::The objective was to state zinc contribution in the effectiveness of novel zinc-doped dentin cements to achieve dentin remineralization, throughout a literature or narrative exploratory review. Literature search was conducted using electronic databases, such as PubMed, MEDLINE, DIMDI, Embase, Scopus and Web of Science...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,评审

    doi:10.1016/j.jmbbm.2020.104232

    authors: Toledano M,Osorio R,Vallecillo-Rivas M,Osorio E,Lynch CD,Aguilera FS,Toledano R,Sauro S

    更新日期:2021-02-01 00:00:00

  • A method for investigating the cellular response to cyclic tension or compression in three-dimensional culture.

    abstract::We have an interest in the cellular response to mechanical stimuli, and here describe an in-vitro method to examine the response of cells cultured in a three-dimensional matrix to mechanical compressive and tensile stress. Synthetic aliphatic polyester scaffolds coated with 45S5 bioactive glass were seeded with human ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.08.006

    authors: Sarrafpour B,Boughton P,Farahani RM,Cox SC,Denyer G,Kelly E,Zoellner H

    更新日期:2018-12-01 00:00:00

  • In situ compressibility of carbonated hydroxyapatite in tooth dentine measured under hydrostatic pressure by high energy X-ray diffraction.

    abstract::Tooth dentine and other bone-like materials contain carbonated hydroxyapatite nanoparticles within a network of collagen fibrils. It is widely assumed that the elastic properties of biogenic hydroxyapatites are identical to those of geological apatite. By applying hydrostatic pressure and by in situ measurements of th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.06.005

    authors: Forien JB,Fleck C,Krywka C,Zolotoyabko E,Zaslansky P

    更新日期:2015-10-01 00:00:00

  • Bone healing response in cyclically loaded implants: Comparing zero, one, and two loading sessions per day.

    abstract::When bone implants are loaded, they are inevitably subjected to displacement relative to bone. Such micromotion generates stress/strain states at the interface that can cause beneficial or detrimental sequels. The objective of this study is to better understand the mechanobiology of bone healing at the tissue-implant ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.05.044

    authors: de Barros E Lima Bueno R,Dias AP,Ponce KJ,Wazen R,Brunski JB,Nanci A

    更新日期:2018-09-01 00:00:00

  • Nitinol stent design - understanding axial buckling.

    abstract::Nitinol׳s superelastic properties permit self-expanding stents to be crimped without plastic deformation, but its nonlinear properties can contribute towards stent buckling. This study investigates the axial buckling of a prototype tracheobronchial nitinol stent design during crimping, with the objective of eliminatin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.08.029

    authors: McGrath DJ,O Brien B,Bruzzi M,McHugh PE

    更新日期:2014-12-01 00:00:00

  • A new longitudinal variation in the structure of collagen fibrils and its relationship to locations of mechanical damage susceptibility.

    abstract::The hierarchical architecture of the collagen fibril is well understood, involving non-integer staggering of collagen molecules which results in a 67 nm periodic molecular density variation termed D-banding. Other than this variation, collagen fibrils are considered to be homogeneous at the micro-scale and beyond. Int...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103849

    authors: Baldwin SJ,Sampson J,Peacock CJ,Martin ML,Veres SP,Lee JM,Kreplak L

    更新日期:2020-10-01 00:00:00

  • A constitutive law for degrading bioresorbable polymers.

    abstract::This paper presents a constitutive law that predicts the changes in elastic moduli, Poisson's ratio and ultimate tensile strength of bioresorbable polymers due to biodegradation. During biodegradation, long polymer chains are cleaved by hydrolysis reaction. For semi-crystalline polymers, the chain scissions also lead ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.02.026

    authors: Samami H,Pan J

    更新日期:2016-06-01 00:00:00

  • Study of nanoscale deformation mechanisms in bulk hexagonal hydroxyapatite under uniaxial loading using molecular dynamics.

    abstract::Hydroxyapatite (HAP) is a natural bioceramic which is currently used in scaffolds and coatings for the regrowth of osseous tissue but offers poor load-bearing capacity compared to other biomaterials. The deformation mechanisms responsible for the mechanical behavior of HAP are not well understood, although the advent ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103894

    authors: Snyder AD,Salehinia I

    更新日期:2020-10-01 00:00:00

  • Identification of biomechanical properties in vivo in human uterine cervix.

    abstract:BACKGROUND AND AIMS:The course and outcome of pregnancy is closely correlated to change of biomechanical properties of the uterine cervix. The aim of this study was to build a non-linear, fiber reinforced mechanical model of the cervix for estimation of mechanical characteristics of the cervix in early- and term-pregna...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.005

    authors: Liao D,Hee L,Sandager P,Uldbjerg N,Gregersen H

    更新日期:2014-11-01 00:00:00

  • Setting mechanism of a new injectable Dicalcium Phosphate Dihydrate (DCPD) forming cement.

    abstract::We previously described the gelation mechanism of calcium polyphosphate (CPP) in the presence of water. In this study, we developed novel and injectable poly-dicalcium phosphate dihydrate (P-DCPD) forming cement by the reaction of acidic CPP gel with alkali tetracalcium phosphate (TTCP). The setting reaction mechanism...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.12.032

    authors: Ren W,Song W,Yurgelevic S,Markel DC

    更新日期:2018-03-01 00:00:00

  • Teleost fish scales amongst the toughest collagenous materials.

    abstract::Fish scales from modern teleost fish are high-performance materials made of cross-plies of collagen type I fibrils reinforced with hydroxyapatite. Recent studies on this material have demonstrated the remarkable performance of this material in tension and against sharp puncture. Although it is known that teleost fish ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.09.025

    authors: Khayer Dastjerdi A,Barthelat F

    更新日期:2015-12-01 00:00:00

  • Hole-pin joining structure with fiber-round-hole distribution of lobster cuticle and biomimetic study.

    abstract::Observations of the cuticle of the Boston Spiny Lobster using scanning electron microscope (SEM) show that it is a natural biocomposite consisting of chitin fibers and sclerotic-protein matrix with hierarchical and helicoidal structure. The SEM images also indicate that there is a hole-pin joining structure in the cut...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.09.001

    authors: Chen B,Fan J,Gou J,Lin S

    更新日期:2014-12-01 00:00:00

  • A study of friction mechanisms between a surrogate skin (Lorica soft) and nonwoven fabrics.

    abstract::Hygiene products such as incontinence pads bring nonwoven fabrics into contact with users' skin, which can cause damage in various ways, including the nonwoven abrading the skin by friction. The aim of the work described here was to develop and use methods for understanding the origin of friction between nonwoven fabr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.04.024

    authors: Cottenden DJ,Cottenden AM

    更新日期:2013-12-01 00:00:00

  • Blast effect on the lower extremities and its mitigation: a computational study.

    abstract::A series of computational studies were performed to investigate the response of the lower extremities of mounted soldiers under landmine detonation. A numerical human body model newly developed at Wayne State University was used to simulate two types of experimental studies and the model predictions were validated aga...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.07.010

    authors: Dong L,Zhu F,Jin X,Suresh M,Jiang B,Sevagan G,Cai Y,Li G,Yang KH

    更新日期:2013-12-01 00:00:00

  • Cutting mechanics of wood by beetle larval mandibles.

    abstract::Wood boring is a feature of several insect species and is a major cause of severe and irreparable damage to trees. Adult females typically deposit their eggs on the stem surface under bark scales. The emerging hatchlings live within wood during their larval phase, avoiding possible predation, whilst continually boring...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104027

    authors: Kundanati L,Chahare NR,Jaddivada S,Karkisaval AG,Sridhar R,Pugno NM,Gundiah N

    更新日期:2020-12-01 00:00:00

  • An investigation of the effect of freezing storage on the biaxial mechanical properties of excised porcine tricuspid valve anterior leaflets.

    abstract::The atrioventricular heart valve (AHV) leaflets are critical to the facilitation of proper unidirectional blood flow through the heart. Previously, studies have been conducted to understand the tissue mechanics of healthy AHV leaflets to inform the development of valve-specific computational models and replacement mat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103438

    authors: Duginski GA,Ross CJ,Laurence DW,Johns CH,Lee CH

    更新日期:2020-01-01 00:00:00

  • Experimental and constitutive modeling approaches for a study of biomechanical properties of human coronary arteries.

    abstract::The study concerns the determination of mechanical properties of human coronary arterial walls with both experimental and constitutive modeling approaches. The research material was harvested from 18 patients (range 50-84 years). On the basis of hospital records and visual observation, each tissue sample was classifie...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.021

    authors: Jankowska MA,Bartkowiak-Jowsa M,Bedzinski R

    更新日期:2015-10-01 00:00:00

  • Resin adjustment of three-dimensional printed thermoset occlusal splints: Bonding properties - Short communication.

    abstract:OBJECTIVES:To evaluate the interfacial adhesion of an autopolymerizing acrylic resin to 3D printed thermoset occlusal splints compared to thermoplastic occlusal splints. MATERIALS AND METHODS:Cylinders made of an autopolymerizing acrylic resin were adhered to 3D printed thermoset and also to thermoplastic plates. A di...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.04.011

    authors: Perea-Lowery L,Vallittu PK

    更新日期:2019-07-01 00:00:00