In situ compressibility of carbonated hydroxyapatite in tooth dentine measured under hydrostatic pressure by high energy X-ray diffraction.

Abstract:

:Tooth dentine and other bone-like materials contain carbonated hydroxyapatite nanoparticles within a network of collagen fibrils. It is widely assumed that the elastic properties of biogenic hydroxyapatites are identical to those of geological apatite. By applying hydrostatic pressure and by in situ measurements of the a- and c- lattice parameters using high energy X-ray diffraction, we characterize the anisotropic deformability of the mineral in the crowns and roots of teeth. The collected data allowed us to calculate the bulk modulus and to derive precise estimates of Young׳s moduli and Poisson׳s ratios of the biogenic mineral particles. The results show that the dentine apatite particles are about 20% less stiff than geological and synthetic apatites and that the mineral has an average bulk modulus K=82.7 GPa. A 5% anisotropy is observed in the derived values of Young׳s moduli, with E11≈91 GPa and E33≈96 GPa, indicating that the nanoparticles are only slightly stiffer along their long axis. Poisson׳s ratio spans ν≈0.30-0.35, as expected. Our findings suggest that the carbonated nanoparticles of biogenic apatite are significantly softer than previously thought and that their elastic properties can be considered to be nearly isotropic.

authors

Forien JB,Fleck C,Krywka C,Zolotoyabko E,Zaslansky P

doi

10.1016/j.jmbbm.2015.06.005

subject

Has Abstract

pub_date

2015-10-01 00:00:00

pages

171-9

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(15)00197-6

journal_volume

50

pub_type

杂志文章
  • Comparison of splinted and non-splinted superstructures of three implants placed in a mandibular distal extension model with missing teeth using modal analysis.

    abstract::This study evaluated the effects of two types of superstructures (splinted crown and non-splinted crown) on four vibration characteristics (natural frequency, damping ratio (DAR), vectors in antiphase, maximum displacement (MDP)) by using modal analysis. These structures were fabricated on three implants placed in the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104050

    authors: Sasaki T,Nakata H,Suzuki A,Hada T,Kasugai S,Kuroda S

    更新日期:2020-12-01 00:00:00

  • Biocompatibility evaluation of a thermoplastic rubber for wireless telemetric intracranial pressure sensor coating.

    abstract::This study investigated the biocompatibility of the experimental thermoplastic rubber Arbomatrix(™) that will be used as the protective coating on a novel intracranial pressure (ICP) sensor silicon chip. Arbomatrix(™) was benchmarked against biocompatible commercial silicone rubber shunt tubing in the brain via a rat ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.01.018

    authors: Yang J,Charif AC,Puskas JE,Phillips H,Shanahan KJ,Garsed J,Fleischman A,Goldman K,Roy S,Luebbers MT,Dombrowski SM,Luciano MG

    更新日期:2015-05-01 00:00:00

  • A new constitutive model for simulation of softening, plateau, and densification phenomena for trabecular bone under compression.

    abstract::A new type of constitutive model and its computational implementation procedure for the simulation of a trabecular bone are proposed in the present study. A yield surface-independent Frank-Brockman elasto-viscoplastic model is introduced to express the nonlinear material behavior such as softening beyond yield point, ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.08.028

    authors: Lee CS,Lee JM,Youn B,Kim HS,Shin JK,Goh TS,Lee JS

    更新日期:2017-01-01 00:00:00

  • Hydrogels with differential and patterned mechanics to study stiffness-mediated myofibroblastic differentiation of hepatic stellate cells.

    abstract::The differentiation of hepatic stellate cells (HSCs) into myofibroblasts is a key event in liver fibrosis. Due to the local stiffening of the extracellular matrix (ECM) during fibrosis, it is of great interest to develop mimics that can be used to investigate the cellular response to changes in mechanics. Here, we use...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.11.008

    authors: Guvendiren M,Perepelyuk M,Wells RG,Burdick JA

    更新日期:2014-10-01 00:00:00

  • Prevention of intestinal adhesion and regeneration of abdominal wall tissue with meshes containing an electrostatically spun acellular dermal matrix (ADM)/silk fibroin (SF) fiber composite polypropylene mesh.

    abstract::The repair of abdominal wall defects often requires the use of polypropylene (PP) as the main material. After a PP mesh is implanted in the body, contact with the intestine can cause adhesions between the intestine and the mesh, leading to serious complications such as intestinal fistula. In this study, we used electr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104087

    authors: Yang D,Song Z,Lin Y,Dong W,Fu S,Yang J,Zhang P,Gu Y

    更新日期:2020-12-01 00:00:00

  • A method and a device for the evaluation of the retention of telescopic dental crowns.

    abstract::Telescopic crowns are used as support for removable dental prostheses' construction. A distinctive feature of crowns often used in their description and comparison is retention, which is understood as resistance when removing the prosthesis or a force needed to disconnect crowns. The article describes a method for the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.01.042

    authors: Majcher A,Leśniewska-Kochanek A,Mierzwińska-Nastalska E

    更新日期:2017-05-01 00:00:00

  • Fatigue strength of Co-Cr-Mo alloy clasps prepared by selective laser melting.

    abstract::We aimed to investigate the fatigue strength of Co-Cr-Mo clasps for removable partial dentures prepared by selective laser melting (SLM). The Co-Cr-Mo alloy specimens for tensile tests (dumbbell specimens) and fatigue tests (clasp specimens) were prepared by SLM with varying angles between the building and longitudina...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.02.032

    authors: Kajima Y,Takaichi A,Nakamoto T,Kimura T,Yogo Y,Ashida M,Doi H,Nomura N,Takahashi H,Hanawa T,Wakabayashi N

    更新日期:2016-06-01 00:00:00

  • Crack initiation from a clinically relevant notch in a highly-crosslinked UHMWPE subjected to static and cyclic loading.

    abstract::Crosslinked Ultra High Molecular Weight Polyethylene (UHMWPE), which is used as a bearing material in total joint replacement components, is subjected to static and cyclic loads in vivo. Resistance to crack initiation from a notch as a function of static and cyclic loads is not well understood for crosslinked UHMWPE. ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.12.032

    authors: Sirimamilla A,Rimnac CM

    更新日期:2019-03-01 00:00:00

  • Study on the effect of graphene oxide (GO) feeding on silk properties based on segmented precise measurement.

    abstract::Silk is widely used in the biomedical field (e.g., surgical sutures) for its excellent mechanical properties and biocompatibility. The properties of silk can be further enhanced by a multitude of methods, including nano particle feeding, which is convenient and green. Generally, the filament length of a silkworm cocoo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104147

    authors: Qu J,Dai M,Ye W,Fang Y,Bian D,Su W,Li F,Sun H,Wei J,Li B

    更新日期:2021-01-01 00:00:00

  • Mechanical performance, corrosion and tribological evaluation of a Co-Cr-Mo alloy processed by MIM for biomedical applications.

    abstract::In this study, the processing parameters mechanical performance, corrosion and tribological evaluation of a low carbon content Co-Cr-Mo alloy are discussed. The production of parts using the Metal Injection Moulding (MIM) process is optimized, specifically concerning the rheological analysis of the prepared feedstocks...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103706

    authors: Herranz G,Berges C,Naranjo JA,García C,Garrido I

    更新日期:2020-05-01 00:00:00

  • R-curve behavior of a short-fiber reinforced resin composite after water storage.

    abstract::As a supplement to our investigation into R-curves in a short-fiber reinforced dental resin composite, we investigate the effects of 2-months water storage. Water is known to degrade the siloxane bonds linking matrix and fillers, which has been suggested to decrease the fracture toughness in conventional resin composi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103674

    authors: Tiu J,Belli R,Lohbauer U

    更新日期:2020-04-01 00:00:00

  • Mechanisms and timing of injury to the thoracic, lumbar and sacral spine in simulated underbody blast PMHS impact tests.

    abstract::During an underbody blast (UBB) event, mounted occupants are exposed to high rate loading of the spine via the pelvis. The objective of this study was to simulate UBB loading conditions and examine mechanisms of injury in the thoracic, lumbar and sacral spine. Fourteen instrumented, whole-body, postmortem human subjec...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104271

    authors: Somasundaram K,Sherman D,Begeman P,Ciarelli T,McCarty SA,Kochkodan JJ,Demetropoulos CK,Cavanaugh JM

    更新日期:2020-12-24 00:00:00

  • A combined experimental, modeling, and computational approach to interpret the viscoelastic response of the white matter brain tissue during indentation.

    abstract::Viscoelastic properties of the white matter brain tissue are systematically studied in this paper utilizing indentation experiments, mathematical modeling, and finite element simulation. It is first demonstrated that the internal stiffness of the instrument needs to be thoroughly obtained and incorporated in the analy...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.037

    authors: Samadi-Dooki A,Voyiadjis GZ,Stout RW

    更新日期:2018-01-01 00:00:00

  • Fabrication and mechanical properties of Al2O3/SiC/ZrO2 functionally graded material by electrophoretic deposition.

    abstract::This study describes the synthesis of Al(2)O(3)/SiC/ZrO(2) functionally graded material (FGM) in bio-implants (artificial joints) by electrophoretic deposition (EPD). A suitable suspension that was based on 2-butanone was applied for the EPD of Al(2)O(3)/SiC/ZrO(2), and a pressureless sintering process was applied as ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.02.029

    authors: Askari E,Mehrali M,Metselaar IH,Kadri NA,Rahman MM

    更新日期:2012-08-01 00:00:00

  • The functions of hydrophobic elastic polyurethane combined with an antibacterial triclosan derivative in the dentin restoration interface.

    abstract::Dentin restoration produces weak interfaces because of the effects of bacterial microflora, biofilms, and mechanical, thermal, and shrinkage stresses. This results in secondary caries. Therefore, hydrophobic elastic polyurethane (PU) containing different concentrations of triclosan derivatives was synthesized and appl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103471

    authors: Guo X,Cheng Q,Yu G,Wang H,Tian Z,Shi Z,Cui Z,Zhu S

    更新日期:2020-02-01 00:00:00

  • Numerical identification method for the non-linear viscoelastic compressible behavior of soft tissue using uniaxial tensile tests and image registration - application to rat lung parenchyma.

    abstract::This paper presents an improved identification method of the constitutive properties of lung parenchyma. We aim to determine the non-linear viscoelastic behavior of lung parenchyma with a particular focus on the compressible properties - i.e. the ability to change volume. Uniaxial tensile tests are performed on living...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.09.018

    authors: Bel-Brunon A,Kehl S,Martin C,Uhlig S,Wall WA

    更新日期:2014-01-01 00:00:00

  • Composite electrospun gelatin fiber-alginate gel scaffolds for mechanically robust tissue engineered cornea.

    abstract::A severe shortage of good quality donor cornea is now an international crisis in public health. Alternatives for donor tissue need to be urgently developed to meet the increasing demand for corneal transplantation. Hydrogels have been widely used as scaffolds for corneal tissue regeneration due to their large water co...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.03.001

    authors: Tonsomboon K,Oyen ML

    更新日期:2013-05-01 00:00:00

  • Cold-rolling behavior of biomedical Ni-free Co-Cr-Mo alloys: Role of strain-induced ε martensite and its intersecting phenomena.

    abstract::Ni-free Co-Cr-Mo alloys are some of the most difficult-to-work metallic materials used commonly in biomedical applications. Since the difficulty in plastically deforming them limits their use, an in-depth understanding of their plastic deformability is of crucial importance for both academic and practical purposes. In...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.10.021

    authors: Mori M,Yamanaka K,Chiba A

    更新日期:2015-03-01 00:00:00

  • An experimental canine patent ductus arteriosus occlusion device based on shape memory polymer foam in a nitinol cage.

    abstract::Patent ductus arteriosus (PDA) is a congenital cardiovascular defect in which a fetal connection between the aorta and pulmonary artery does not spontaneously close shortly after birth. If left uncorrected serious complications and even death can occur. Surgical ligation is the traditional treatment method; however, i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.033

    authors: Wierzbicki MA,Raines SB,Gordon SG,Criscione JC,Saunders AB,Birch S,Due B,Keller B,Nash LD,Miller MW,Maitland DJ

    更新日期:2017-11-01 00:00:00

  • Poroviscoelastic characterization of particle-reinforced gelatin gels using indentation and homogenization.

    abstract::Hydrogels are promising materials for bioengineering applications, and are good model materials for the study of hydrated biological tissues. As these materials often have a structural function, the measurement of their mechanical properties is of fundamental importance. In the present study gelatin gels reinforced wi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.01.009

    authors: Galli M,Fornasiere E,Cugnoni J,Oyen ML

    更新日期:2011-05-01 00:00:00

  • Finite element simulation for the mechanical characterization of soft biological materials by atomic force microscopy.

    abstract::The characterization of the mechanical properties of soft materials has been traditionally performed through uniaxial tensile tests. Nevertheless, this method cannot be applied to certain extremely soft materials, such as biological tissues or cells that cannot be properly subjected to these tests. Alternative non-des...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.006

    authors: Valero C,Navarro B,Navajas D,García-Aznar JM

    更新日期:2016-09-01 00:00:00

  • Effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading.

    abstract::This study evaluated the effect of air-particle abrasion protocols on the biaxial flexural strength, surface characteristics and phase transformation of zirconia after cyclic loading. Disc-shaped zirconia specimens (Ø: 15mm, thickness: 1.2mm) (N=32) were submitted to one of the air-particle abrasion protocols (n=8 per...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.01.005

    authors: Ozcan M,Melo RM,Souza RO,Machado JP,Felipe Valandro L,Botttino MA

    更新日期:2013-04-01 00:00:00

  • Influence of the overall stiffness of a load-bearing porous titanium implant on bone ingrowth in critical-size mandibular bone defects in sheep.

    abstract::The aim of this work was to assess the influence of reduction of the apparent mechanical properties of fully load-bearing porous titanium implants used in mandibular bone defects. Segmental 18mm long bone defects were created bilaterally in the lower jaws of adult ewes. One group of 6 ewes (group A) was treated with l...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.02.036

    authors: Schouman T,Schmitt M,Adam C,Dubois G,Rouch P

    更新日期:2016-06-01 00:00:00

  • Numerical predictions of the interaction between highly nonlinear solitary waves and the microstructure of trabecular bone in the femoral head.

    abstract::The unique properties of highly nonlinear solitary waves in granular chains have prompted extensive research in the area of non-destructive testing and led to the development of new diagnostic schemes with potential applications in the healthcare industry. Here, we study numerically the interaction between highly nonl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103805

    authors: Yoon S,Schiffer A,Kim JJ,Jang IG,Lee S,Kim TY

    更新日期:2020-09-01 00:00:00

  • Biomechanical and biochemical protective effect of low-level laser therapy for Achilles tendinitis.

    abstract::For three decades, low level laser therapy (LLLT) has been used for treatment of tendinitis as well as other musculoskeletal diseases. Nevertheless, the biological mechanisms involved remain not completely understood. In this work, the effects of LLLT and of the widely used nonsteroidal anti-inflammatory drug, diclofe...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.028

    authors: Marcos RL,Arnold G,Magnenet V,Rahouadj R,Magdalou J,Lopes-Martins RÁ

    更新日期:2014-01-01 00:00:00

  • Effect of size and dimensional tolerance of reverse total shoulder arthroplasty on wear: An in-silico study.

    abstract::Although huge research efforts have been devoted to wear analysis of ultra-high molecular weight polyethylene (UHMWPE) in hip and knee implants, shoulder prostheses have been studied only marginally. Recently, the authors presented a numerical wear model of reverse total shoulder arthroplasties (RTSAs), and its applic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.033

    authors: Mattei L,Di Puccio F,Joyce TJ,Ciulli E

    更新日期:2016-08-01 00:00:00

  • The impact of metastasis on the mineral phase of vertebral bone tissue.

    abstract::The negative impact of metastases on the mechanical performance of vertebral bone is often attributed to reduced bone density and/or compromised architecture. However limited characterization has been done on the impact of metastasis on the mineralization of bone tissue and resulting changes in material behaviour. Thi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.12.017

    authors: Burke M,Atkins A,Kiss A,Akens M,Yee A,Whyne C

    更新日期:2017-05-01 00:00:00

  • Biocompatibility and compressive properties of Ti-6Al-4V scaffolds having Mg element.

    abstract::Porous scaffolds of Ti-6Al-4V were produced by mixing of this alloy with different amount of magnesium (Mg) powders. The mixtures were compacted in steel die by applying uniaxial pressure of 500 MPa before sintering the compacts in sealed quartz tubes at 900 °C for 2 h. Employing Archimedes׳ principle and Image Tool s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.04.015

    authors: Kalantari SM,Arabi H,Mirdamadi S,Mirsalehi SA

    更新日期:2015-08-01 00:00:00

  • Mechanical performance of highly permeable laser melted Ti6Al4V bone scaffolds.

    abstract::Critically engineered stiffness and strength of a scaffold are crucial for managing maladapted stress concentration and reducing stress shielding. At the same time, suitable porosity and permeability are key to facilitate biological activities associated with bone growth and nutrient delivery. A systematic balance of ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103517

    authors: Arjunan A,Demetriou M,Baroutaji A,Wang C

    更新日期:2020-02-01 00:00:00

  • Mechanical response of human abdominal walls ex vivo: Effect of an incisional hernia and a mesh repair.

    abstract::The design of meshes for the treatment of incisional hernias could benefit from better knowledge of the mechanical response of the abdominal wall and how this response is affected by the implant. The aim of this study was to characterise the mechanical behaviour of the human abdominal wall. Abdominal walls were tested...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.07.002

    authors: Podwojewski F,Otténio M,Beillas P,Guérin G,Turquier F,Mitton D

    更新日期:2014-10-01 00:00:00