Mechanical response of human abdominal walls ex vivo: Effect of an incisional hernia and a mesh repair.

Abstract:

:The design of meshes for the treatment of incisional hernias could benefit from better knowledge of the mechanical response of the abdominal wall and how this response is affected by the implant. The aim of this study was to characterise the mechanical behaviour of the human abdominal wall. Abdominal walls were tested ex vivo in three states: intact, after creation of a defect simulating an incisional hernia, and after reparation with a mesh implanted intraperitonally. For each state, the abdominal wall was subjected to air pressure loading. Local strain fields were determined using digital image correlation techniques. The strain fields on the internal and external surfaces of the abdominal wall exhibited different patterns. The strain patterns on the internal surface appeared to be related to the underlying anatomy of the abdominal wall. Higher strains were observed along the linea alba than along the perpendicular direction. Under pressure loading, the created incision increased the strain of the abdominal wall compared to the intact state in 5 cases of a total 6. In addition, the mesh repair decreased the strains of the abdominal wall compared to the incised state in 4 cases of 6. These results suggest that the intraperitoneal mesh restores at least partially the mechanical behaviour of the wall and provides quantification of the effects on the strains in various regions.

authors

Podwojewski F,Otténio M,Beillas P,Guérin G,Turquier F,Mitton D

doi

10.1016/j.jmbbm.2014.07.002

subject

Has Abstract

pub_date

2014-10-01 00:00:00

pages

126-33

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(14)00194-5

journal_volume

38

pub_type

杂志文章
  • Tribology and hydrophobicity of a biocompatible GPTMS/PFPE coating on Ti6Al4V surfaces.

    abstract::Tribological properties of perfluoropolyether (PFPE) coated 3-glycidoxypropyltrimethoxy silane (GPTMS) SAMs (self-assembled monolayers) onto Ti6Al4V alloy substrate were studied using ball-on-disk experiments. GPTMS SAMs deposition onto a Ti6Al4V alloy surface was carried out using solution phase method. Ultra-thin la...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.06.016

    authors: Panjwani B,Sinha SK

    更新日期:2012-11-01 00:00:00

  • The interfascicular matrix enables fascicle sliding and recovery in tendon, and behaves more elastically in energy storing tendons.

    abstract::While the predominant function of all tendons is to transfer force from muscle to bone and position the limbs, some tendons additionally function as energy stores, reducing the cost of locomotion. Energy storing tendons experience extremely high strains and need to be able to recoil efficiently for maximum energy stor...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.04.009

    authors: Thorpe CT,Godinho MSC,Riley GP,Birch HL,Clegg PD,Screen HRC

    更新日期:2015-12-01 00:00:00

  • Analysis of the mechanical response of biomimetic materials with highly oriented microstructures through 3D printing, mechanical testing and modeling.

    abstract::Many biomineralized organisms have evolved highly oriented nanostructures to perform specific functions. One key example is the abrasion-resistant rod-like microstructure found in the radular teeth of Chitons (Cryptochiton stelleri), a large mollusk. The teeth consist of a soft core and a hard shell that is abrasion r...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.026

    authors: de Obaldia EE,Jeong C,Grunenfelder LK,Kisailus D,Zavattieri P

    更新日期:2015-08-01 00:00:00

  • The impact of discrete compartments of a multi-compartment collagen-GAG scaffold on overall construct biophysical properties.

    abstract::Orthopedic interfaces such as the tendon-bone junction (TBJ) present unique challenges for biomaterials development. Here we describe a multi-compartment collagen-GAG scaffold fabricated via lyophilization that contains discrete mineralized (CGCaP) and non-mineralized (CG) regions joined by a continuous interface. Mod...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.07.016

    authors: Weisgerber DW,Kelkhoff DO,Caliari SR,Harley BA

    更新日期:2013-12-01 00:00:00

  • Looped ends versus open ends braided stent: A comparison of the mechanical behaviour using analytical and numerical methods.

    abstract::The present study has two major purposes: firstly, to investigate whether the analytical model proposed by Jedwab and Clerc for assessing the mechanical behaviour of an open ends metallic braided stent is applicable to the looped ends stent design and secondly, to compare the response of the two stent designs subjecte...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.025

    authors: Shanahan C,Tiernan P,Tofail SAM

    更新日期:2017-11-01 00:00:00

  • Effects of inter-synergistic mechanical interactions on the mechanical behaviour of activated spastic semitendinosus muscle of patients with cerebral palsy.

    abstract::Previous physiological experiments and finite element modelling indicate that inter-synergistic epimuscular myofascial force transmission (EMFT) between co-activated muscles has a potential to affect healthy muscle's contribution to joint moment and joint range of movement. This is quite relevant for patients with cer...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.040

    authors: Kaya CS,Temelli Y,Ates F,Yucesoy CA

    更新日期:2018-01-01 00:00:00

  • Micromechanical properties of canine femoral articular cartilage following multiple freeze-thaw cycles.

    abstract::Tissue material properties are crucial to understanding their mechanical function, both in healthy and diseased states. However, in certain circumstances logistical limitations can prevent testing on fresh samples necessitating one or more freeze-thaw cycles. To date, the nature and extent to which the material proper...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.03.006

    authors: Peters AE,Comerford EJ,Macaulay S,Bates KT,Akhtar R

    更新日期:2017-07-01 00:00:00

  • Prediction of cross section fracture path of cortical bone through nanoindentation array.

    abstract::Although great progresses in the fracture mechanisms and deformation behaviors of cortical bones have been achieved, the effective methods to predict the surface fracture path of cortical bones are still difficult. By using depth-sensing nanoindentation measurement technique, the hardness distribution map of cortical ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104303

    authors: Ma Z,Qiang Z,Zeng K,Xiao J,Zhou L,Zu L,Zhao H,Ren L

    更新日期:2021-01-20 00:00:00

  • Evaluating thoracolumbar spine response during simulated underbody blast impact using a total human body finite element model.

    abstract::In a study of spine injuries in Operation Iraqi Freedom (OIF) and Operation Enduring Freedom (OEF) from 2001-09, spinal fractures sustained by mounted soldiers accounted for 26% of all injuries, and of that, 43% were caused by explosions [1]. The thoracolumbar region is the most vulnerable area of the spine [2], and i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103398

    authors: Somasundaram K,Zhang L,Sherman D,Begeman P,Lyu D,Cavanaugh JM

    更新日期:2019-12-01 00:00:00

  • A method and a device for the evaluation of the retention of telescopic dental crowns.

    abstract::Telescopic crowns are used as support for removable dental prostheses' construction. A distinctive feature of crowns often used in their description and comparison is retention, which is understood as resistance when removing the prosthesis or a force needed to disconnect crowns. The article describes a method for the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.01.042

    authors: Majcher A,Leśniewska-Kochanek A,Mierzwińska-Nastalska E

    更新日期:2017-05-01 00:00:00

  • Study on the effect of graphene oxide (GO) feeding on silk properties based on segmented precise measurement.

    abstract::Silk is widely used in the biomedical field (e.g., surgical sutures) for its excellent mechanical properties and biocompatibility. The properties of silk can be further enhanced by a multitude of methods, including nano particle feeding, which is convenient and green. Generally, the filament length of a silkworm cocoo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104147

    authors: Qu J,Dai M,Ye W,Fang Y,Bian D,Su W,Li F,Sun H,Wei J,Li B

    更新日期:2021-01-01 00:00:00

  • Development and characterization of cross-linked gellan gum and retrograded starch blend hydrogels for drug delivery applications.

    abstract::The retrogradation of high amylose starch (5% or 10%), by isothermal cycles at 4°C (method 1) or by alternating thermal cycles (method 2) was efficient and promoted important structural modifications. Hydrogels of gellan gum and starch retrograded blends, containing or not ketoprofen, were prepared by ionic and dual c...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.08.005

    authors: Oliveira Cardoso VM,Stringhetti Ferreira Cury B,Evangelista RC,Daflon Gremião MP

    更新日期:2017-01-01 00:00:00

  • Wear characteristics of WSU total ankle replacement devices under shear and torsion loads.

    abstract:BACKGROUND:There are several factors that contribute to the failure of total ankle replacement (TAR). Aseptic loosening is one of the primary mechanisms of failure in TAR. Since a cross-linked ultrahigh molecular weight polyethylene (UHMWPE) is used as liner material, there is a need to quantify and develop methods to ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.12.010

    authors: Gundapaneni D,Tsatalis JT,Laughlin RT,Goswami T

    更新日期:2015-04-01 00:00:00

  • Mechanical characterization of oligo(ethylene glycol)-based hydrogels by dynamic nanoindentation experiments.

    abstract::Oligo(ethylene glycol)-based (OEG) hydrogel samples of varying cross-link densities and degrees of swelling were characterized through dynamic nanoindentation testing. Experiments were performed using a non-standard nanoindentation method, which was validated on a standard polystyrene sample. This method maximizes the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.02.009

    authors: Guglielmi PO,Herbert EG,Tartivel L,Behl M,Lendlein A,Huber N,Lilleodden ET

    更新日期:2015-06-01 00:00:00

  • Thermo-mechanical behavior and structure of melt blown shape-memory polyurethane nonwovens.

    abstract::New processing methods for shape-memory polymers allow for tailoring material properties for numerous applications. Shape-memory nonwovens have been previously electrospun, but melt blow processing has yet to be evaluated. In order to determine the process parameters affecting shape-memory behavior, this study examine...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.038

    authors: Safranski DL,Boothby JM,Kelly CN,Beatty K,Lakhera N,Frick CP,Lin A,Guldberg RE,Griffis JC

    更新日期:2016-09-01 00:00:00

  • On multiscale boundary conditions in the computational homogenization of an RVE of tendon fascicles.

    abstract::Present study provides a numerical investigation on multiscale boundary conditions in the computational homogenization of a representative volume element (RVE) of tendon fascicles. A three-dimensional hexagonal-helicoidal finite element RVE composed of two material phases (collagen fibers and cells) and three finite s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.12.003

    authors: Carniel TA,Klahr B,Fancello EA

    更新日期:2019-03-01 00:00:00

  • Characterisation of clinical and newly fabricated meshes for pelvic organ prolapse repair.

    abstract::Clinical meshes used in pelvic organ prolapse (POP) repair are predominantly manufactured from monofilament polypropylene (PP). Complications from the use of these meshes in transvaginal kits, including mesh exposure and pain, have prompted two public health notifications by the FDA. The aim of this study was to compa...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.04.002

    authors: Edwards SL,Werkmeister JA,Rosamilia A,Ramshaw JA,White JF,Gargett CE

    更新日期:2013-07-01 00:00:00

  • Interfacial indentations in biological composites.

    abstract::Biocomposites comprise highly stiff reinforcement elements connected by a compliant matrix material. While the interfacial elastic properties of these biocomposites play a key role in determining the mechanical properties of the entire biocomposite, these properties cannot be measured directly from standard nanomechan...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104209

    authors: Shelef Y,Bar-On B

    更新日期:2021-02-01 00:00:00

  • Adaptive responses of murine osteoblasts subjected to coupled mechanical stimuli.

    abstract::Restitution of the natural organization and orientation of cells is imperative for the construction of functional tissue scaffolds. While numerous studies have exploited mechanical methods to engineer tissues with the desired cellular architecture, fundamental knowledge is still lacking in understanding the manner in ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.09.018

    authors: Serrano JC,Cora-Cruz J,Diffoot-Carlo N,Sundaram PA

    更新日期:2018-01-01 00:00:00

  • Material properties of human patellar-ligament grafts from the elderly population.

    abstract::The aim of the presented study was to estimate the material properties of human patellar ligaments from the elderly population by means of tensile tests. The experimental part was conducted on a custom tensile-testing device, with a built-in enclosure to simulate in-vivo conditions, using 25 (15 female, 10 male) bone-...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103994

    authors: Kranjec M,Trajkovski A,Krašna S,Hribernik M,Kunc R

    更新日期:2020-10-01 00:00:00

  • Comparison of endocrowns made of lithium disilicate glass-ceramic or polymer-infiltrated ceramic networks and direct composite resin restorations: fatigue performance and stress distribution.

    abstract::This study compared the fatigue performance and the stress distribution of endodontically treated molars restored with endocrowns obtained with lithium disilicate glass-ceramic or a polymer-infiltrated ceramic network, both processed by CAD-CAM, and direct composite restorations. Forty-eight human mandibular molars we...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103401

    authors: Dartora G,Rocha Pereira GK,Varella de Carvalho R,Zucuni CP,Valandro LF,Cesar PF,Caldas RA,Bacchi A

    更新日期:2019-12-01 00:00:00

  • Zn-doping of silicate and hydroxyapatite-based cements: Dentin mechanobiology and bioactivity.

    abstract::The objective was to state zinc contribution in the effectiveness of novel zinc-doped dentin cements to achieve dentin remineralization, throughout a literature or narrative exploratory review. Literature search was conducted using electronic databases, such as PubMed, MEDLINE, DIMDI, Embase, Scopus and Web of Science...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,评审

    doi:10.1016/j.jmbbm.2020.104232

    authors: Toledano M,Osorio R,Vallecillo-Rivas M,Osorio E,Lynch CD,Aguilera FS,Toledano R,Sauro S

    更新日期:2021-02-01 00:00:00

  • The functions of hydrophobic elastic polyurethane combined with an antibacterial triclosan derivative in the dentin restoration interface.

    abstract::Dentin restoration produces weak interfaces because of the effects of bacterial microflora, biofilms, and mechanical, thermal, and shrinkage stresses. This results in secondary caries. Therefore, hydrophobic elastic polyurethane (PU) containing different concentrations of triclosan derivatives was synthesized and appl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103471

    authors: Guo X,Cheng Q,Yu G,Wang H,Tian Z,Shi Z,Cui Z,Zhu S

    更新日期:2020-02-01 00:00:00

  • Assessment of a long-term in vitro model to characterize the mechanical behavior and macrophage-mediated degradation of a novel, degradable, electrospun poly-urethane vascular graft.

    abstract::An assessment tool to evaluate the degradation of biodegradable materials in a more physiological environment is still needed. Macrophages are critical players in host response, remodeling and degradation. In this study, a cell culture model using monocyte-derived primary macrophages was established to study the degra...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104077

    authors: Enayati M,Puchhammer S,Iturri J,Grasl C,Kaun C,Baudis S,Walter I,Schima H,Liska R,Wojta J,Toca-Herrera JL,Podesser BK,Bergmeister H

    更新日期:2020-12-01 00:00:00

  • Fatigue life of bovine meniscus under longitudinal and transverse tensile loading.

    abstract::The knee meniscus is composed of a fibrous extracellular matrix that is subjected to large and repeated loads. Consequently, the meniscus is frequently torn, and a potential mechanism for failure is fatigue. The objective of this study was to measure the fatigue life of bovine meniscus when applying cyclic tensile loa...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.12.020

    authors: Creechley JJ,Krentz ME,Lujan TJ

    更新日期:2017-05-01 00:00:00

  • An analytical solution for the stress state at stent-coating interfaces.

    abstract::In this paper an analytical solution for the stress state in a coated stent is presented, with a particular focus on the interface stresses between the coating and stent. As a first step a simplified stent architecture consisting of a bi-layered composite elastic arch is considered. The variations of normal and shear ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.02.009

    authors: Parry G,McGarry P

    更新日期:2012-06-01 00:00:00

  • Custom-built electrostatics and supplementary bonding in the design of reinforced Collagen-g-P(methyl methacrylate-co-ethyl acrylate)/ nylon 66 core-shell fibers.

    abstract::In this study, Acid Soluble Collagen-g-P(methyl methacrylate-co-ethyl acrylate) (CME) was synthesized to take advantage of the flexibility of the resulted branched polymer chains and the high density of their chain entanglement. The coaxial electrospinning technique was applied to study the effect of electrically and ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.002

    authors: Bazrafshan Z,Stylios GK

    更新日期:2018-11-01 00:00:00

  • Finite element simulation for the mechanical characterization of soft biological materials by atomic force microscopy.

    abstract::The characterization of the mechanical properties of soft materials has been traditionally performed through uniaxial tensile tests. Nevertheless, this method cannot be applied to certain extremely soft materials, such as biological tissues or cells that cannot be properly subjected to these tests. Alternative non-des...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.006

    authors: Valero C,Navarro B,Navajas D,García-Aznar JM

    更新日期:2016-09-01 00:00:00

  • Verification and implementation of a modified split Hopkinson pressure bar technique for characterizing biological tissue and soft biosimulant materials under dynamic shear loading.

    abstract::Modeling human body response to dynamic loading events and developing biofidelic human surrogate systems require accurate material properties over a range of loading rates for various human organ tissues. This work describes a technique for measuring the shear properties of soft biomaterials at high rates of strain (1...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.06.008

    authors: Trexler MM,Lennon AM,Wickwire AC,Harrigan TP,Luong QT,Graham JL,Maisano AJ,Roberts JC,Merkle AC

    更新日期:2011-11-01 00:00:00

  • Influence of the fabrication process and fluoride content on the tribocorrosion behaviour of Ti6Al4V biomedical alloy in artificial saliva.

    abstract::Titanium and its alloys are widely used as dental implants due to their low density, excellent biocompatibility, mechanical properties and corrosion resistance. However, during their lifetime Ti6Al4V biomedical alloys are subjected to different mechanical actions (i.e., sliding or fretting), thus resulting in a triboc...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.01.019

    authors: Licausi MP,Igual Muñoz A,Amigó Borrás V

    更新日期:2013-04-01 00:00:00