An analytical solution for the stress state at stent-coating interfaces.

Abstract:

:In this paper an analytical solution for the stress state in a coated stent is presented, with a particular focus on the interface stresses between the coating and stent. As a first step a simplified stent architecture consisting of a bi-layered composite elastic arch is considered. The variations of normal and shear stress at the interface as functions of the boundary conditions at the base of the arch are explored. Depending on applied displacement and rotation, very distinct distributions of stress occur along the interface: dominant shear or dominant normal stress, compressive or tensile normal stress. A bi-layered composite elastic strut is then added to the composite elastic arch in order to create a realistic coated stent geometry. A displacement is applied to the bottom of the strut to simulate stent deployment. The addition of the strut is found to increase the normal stress and decrease the shear stress at all points on the interface. The influence of the various geometrical and material parameters on interface stress is explored using the analytical procedure developed in the paper, providing practical insight for stent-coating design.

authors

Parry G,McGarry P

doi

10.1016/j.jmbbm.2012.02.009

subject

Has Abstract

pub_date

2012-06-01 00:00:00

pages

183-96

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(12)00060-4

journal_volume

10

pub_type

杂志文章
  • Composite electrospun gelatin fiber-alginate gel scaffolds for mechanically robust tissue engineered cornea.

    abstract::A severe shortage of good quality donor cornea is now an international crisis in public health. Alternatives for donor tissue need to be urgently developed to meet the increasing demand for corneal transplantation. Hydrogels have been widely used as scaffolds for corneal tissue regeneration due to their large water co...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.03.001

    authors: Tonsomboon K,Oyen ML

    更新日期:2013-05-01 00:00:00

  • Simultaneous microstructural and mechanical characterization of human corneas at increasing pressure.

    abstract::The cornea, through its shape, is the main contributor to the eye׳s focusing power. Pathological alterations of the cornea strongly affect the eye power. To improve treatments, complex biomechanical models have been developed based on the architecture and mechanical properties of the collagen network in the stroma, th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.031

    authors: Benoit A,Latour G,Marie-Claire SK,Allain JM

    更新日期:2016-07-01 00:00:00

  • Transient behavior and relaxation of microcapsules with a cross-linked human serum albumin membrane.

    abstract::Capsules consist of droplets enclosed by a membrane with shear resistant properties especially when fabricated by interfacial cross-linking. In many applications, the protection and release of the internal medium need to be strictly controlled. It is possible to tune the membrane mechanical properties by changing the ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.09.008

    authors: Gires PY,Barthès-Biesel D,Leclerc E,Salsac AV

    更新日期:2016-05-01 00:00:00

  • Cytocompatibility, mechanical and dissolution properties of high strength boron and iron oxide phosphate glass fibre reinforced bioresorbable composites.

    abstract::In this study, Polylactic acid (PLA)/phosphate glass fibres (PGF) composites were prepared by compression moulding. Fibres produced from phosphate based glasses P2O5-CaO-MgO-Na2O (P45B0), P2O5-CaO-MgO-Na2O-B2O3 (P45B5), P2O5-CaO-MgO-Na2O-Fe2O3 (P45Fe3) and P2O5-CaO-MgO-Na2O-B2O3-Fe2O3 (P45B5Fe3) were used to reinforce...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.011

    authors: Sharmin N,Hasan MS,Parsons AJ,Rudd CD,Ahmed I

    更新日期:2016-06-01 00:00:00

  • Analysis of multiple shear wave modes in a nonlinear soft solid: Experiments and finite element simulations with a tilted acoustic radiation force.

    abstract::Tissue nonlinearity is conventionally measured in shear wave elastography by studying the change in wave speed caused by the tissue deformation, generally known as the acoustoelastic effect. However, these measurements have mainly focused on the excitation and detection of one specific shear mode, while it is theoreti...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103754

    authors: Caenen A,Knight AE,Rouze NC,Bottenus NB,Segers P,Nightingale KR

    更新日期:2020-07-01 00:00:00

  • Influence of biocorrosion on microstructure and mechanical properties of deformed Mg-Y-Er-Zn biomaterial containing 18R-LPSO phase.

    abstract::The microstructure and mechanical properties of as-extruded Mg-8Y-1Er-2Zn (wt%) alloy containing long period stacking ordered (LPSO) phase are comparatively investigated before and after corrosion in a simulated body fluid (SBF) at 37°C. The as-extruded alloy consists of a long strip-like 18R-LPSO phase and some fine ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.012

    authors: Leng Z,Zhang J,Yin T,Zhang L,Guo X,Peng Q,Zhang M,Wu R

    更新日期:2013-12-01 00:00:00

  • Mechano-geometrical skeletal muscle fibre characterisation under cyclic and relaxation loading.

    abstract::In the present work, mechano-geometrical characterisations of skeletal muscle fibres in two different deformation states, namely, axial tension and axial compression, were realised. In both cases, cyclic and relaxation tests were performed. Additionally, the changes in the volume of the fibres during deformation were ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104001

    authors: Böl M,Iyer R,Garcés-Schröder M,Kohn S,Dietzel A

    更新日期:2020-10-01 00:00:00

  • Development of novel zirconia implant's materials gradated design with improved bioactive surface.

    abstract::Zirconia implants are becoming a preference choice for different applications such as knee, dental, among others. In order to improve osseointegration, implant's surfaces are usually coated with bioactive materials like hydroxyapatite (HAp) and beta-tricalcium phosphate (β-TCP) that are very similar to the calcium pho...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.02.022

    authors: Faria D,Pires JM,Boccaccini AR,Carvalho O,Silva FS,Mesquita-Guimarães J

    更新日期:2019-06-01 00:00:00

  • Development of label-free biophysical markers in osteogenic maturation.

    abstract::The spatial and temporal changes of morphological and mechanical properties of living cells reflect complex functionally-associated processes. Monitoring these modifications could provide a direct information on the cellular functional state. Here we present an integrated biophysical approach to the quantification of ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103581

    authors: Bartolozzi A,Viti F,De Stefano S,Sbrana F,Petecchia L,Gavazzo P,Vassalli M

    更新日期:2020-03-01 00:00:00

  • Mechanisms and timing of injury to the thoracic, lumbar and sacral spine in simulated underbody blast PMHS impact tests.

    abstract::During an underbody blast (UBB) event, mounted occupants are exposed to high rate loading of the spine via the pelvis. The objective of this study was to simulate UBB loading conditions and examine mechanisms of injury in the thoracic, lumbar and sacral spine. Fourteen instrumented, whole-body, postmortem human subjec...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104271

    authors: Somasundaram K,Sherman D,Begeman P,Ciarelli T,McCarty SA,Kochkodan JJ,Demetropoulos CK,Cavanaugh JM

    更新日期:2020-12-24 00:00:00

  • Bioactive composite for keratoprosthesis skirt.

    abstract::In this study, the fabrication and properties of a synthetic keratoprosthesis skirt for use in osteo-odonto-keratoprosthesis (OOKP) surgery are discussed. In the search for a new material concept, bioactive glass and polymethyl methacrylate (PMMA)-based composites were prepared. Three different bioactive glasses (i.e....

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.05.025

    authors: Laattala K,Huhtinen R,Puska M,Arstila H,Hupa L,Kellomäki M,Vallittu PK

    更新日期:2011-11-01 00:00:00

  • An adaptive finite element simulation of fretting wear damage at the head-neck taper junction of total hip replacement: The role of taper angle mismatch.

    abstract::An adaptive finite element simulation was developed to predict fretting wear in a head-neck taper junction of hip joint implant through a two dimensional (2D) model and based on the Archard wear equation. This model represents the most critical section of the head-neck junction which was identified from a 3D model of ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.003

    authors: Fallahnezhad K,Oskouei RH,Badnava H,Taylor M

    更新日期:2017-11-01 00:00:00

  • Effect of collagen packing and moisture content on leather stiffness.

    abstract::Applications for skin derived collagen materials, such as leather and acellular dermal matrices, usually require both strength and flexibility. In general, both the tensile modulus (which has an impact on flexibility) and strength are known to increase with fiber alignment, in the tensile direction, for practically al...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.10.004

    authors: Kelly SJR,Weinkamer R,Bertinetti L,Edmonds RL,Sizeland KH,Wells HC,Fratzl P,Haverkamp RG

    更新日期:2019-02-01 00:00:00

  • Planar biaxial extension of the lumbar facet capsular ligament reveals significant in-plane shear forces.

    abstract::The lumbar facet capsular ligament (FCL) articulates with six degrees of freedom during spinal motions of flexion/extension, lateral bending, and axial rotation. The lumbar FCL is composed of highly aligned collagen fiber bundles on the posterior surface (oriented primarily laterally between the rigid articular facets...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.08.019

    authors: Claeson AA,Barocas VH

    更新日期:2017-01-01 00:00:00

  • Osteogenesis enhancement of silk fibroin/ α-TCP cement by N-acetyl cysteine through Wnt/β-catenin signaling pathway in vivo and vitro.

    abstract::High brittleness and lack osteogenesis are two major limitations of calcium phosphate cement (CPC) in application in bone defect reconstruction. Here we prepared a composite calcium phosphate cement by mixing N-acetyl cysteine loaded silk fibroin solution with α-tricalcium phosphate. In vitro cytology experiment revea...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103451

    authors: Feng T,Niu J,Pi B,Lu Y,Wang J,Zhang W,Li B,Yang H,Zhu X

    更新日期:2020-01-01 00:00:00

  • Development and optimisation of hydroxyapatite-ß-TCP functionally gradated biomaterial.

    abstract::Use of hydroxyapatite (HAP) for biomaterials is widely established, often in a combination with titanium alloy substrates in orthopaedic and other implants. Porous HAP-based coatings undergo sintering and heat treatment processes to achieve proper level of density yet avoiding undesirable reactions and phase changes. ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.11.017

    authors: Gasik M,Keski-Honkola A,Bilotsky Y,Friman M

    更新日期:2014-02-01 00:00:00

  • Mechanical and biological behavior of ultrafine-grained Ti alloy aneurysm clip processed using high-pressure torsion.

    abstract::Severe plastic deformation (SPD) has recently been advanced as the main process for fabricating bulk ultrafine grained or nanocrystalline metallic materials, which present much higher strength and better bio-compatibility than coarse-grained counterparts. Medical devices, such as aneurysm clips and dental implants, re...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.02.002

    authors: Um HY,Park BH,Ahn DH,Abd El Aal MI,Park J,Kim HS

    更新日期:2017-04-01 00:00:00

  • Myoglobin and troponin concentrations are increased in early stage deep tissue injury.

    abstract::Pressure-induced deep tissue injury is a form of pressure ulcer which is difficult to detect and diagnose at an early stage, before the wound has severely progressed and becomes visible at the skin surface. At the present time, no such detection technique is available. To test the hypothesis that muscle damage biomark...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.12.026

    authors: Traa WA,Strijkers GJ,Bader DL,Oomens CWJ

    更新日期:2019-04-01 00:00:00

  • Evaluation of the mechanical properties and degree of conversion of 3D printed splint material.

    abstract:OBJECTIVE:To evaluate the effect of post-curing method, printing layer thickness, and water storage on the mechanical properties and degree of conversion of a light-curing methacrylate based resin material (IMPRIMO® LC Splint), used for the fabrication of 3D printed occlusal splints and surgical guides. METHODS:96 bar...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104254

    authors: Perea-Lowery L,Gibreel M,Vallittu PK,Lassila L

    更新日期:2021-03-01 00:00:00

  • Adhesion of ligand-conjugated biosynthesized magnetite nanoparticles to triple negative breast cancer cells.

    abstract::This paper presents the results of an experimental study of the adhesion forces between components of model conjugated magnetite nanoparticle systems for improved selectivity in the specific targeting of triple negative breast cancer. Adhesion forces between chemically synthesized magnetite nanoparticles (CMNPs), bios...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.02.004

    authors: Obayemi JD,Hu J,Uzonwanne VO,Odusanya OS,Malatesta K,Anuku N,Soboyejo WO

    更新日期:2017-04-01 00:00:00

  • Computational micromechanics of bioabsorbable magnesium stents.

    abstract::Magnesium alloys are a promising candidate material for an emerging generation of absorbable metal stents. Due to its hexagonal-close-packed lattice structure and tendency to undergo twinning, the deformation behaviour of magnesium is quite different to that of conventional stent materials, such as stainless steel 316...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.01.007

    authors: Grogan JA,Leen SB,McHugh PE

    更新日期:2014-06-01 00:00:00

  • A novel assessment of microstructural and mechanical behaviour of bilayer silica-reinforced nanocomposite hydrogels as a candidate for artificial cartilage.

    abstract::The complex structure of healthy articular cartilage facilitates the joint withstanding the imposed pressures and retaining interstitial fluid to lessen stresses on its soft tissue, while easing the locomotion and minimising friction between cartilage mates. Avascular nature of this tissue results in unrecoverable dam...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2021.104333

    authors: Mostakhdemin M,Nand A,Ramezani M

    更新日期:2021-01-18 00:00:00

  • Thickness optimization of auricular silicone scaffold based on finite element analysis.

    abstract::An optimized thickness of a transplantable auricular silicone scaffold was researched. The original image data were acquired from CT scans, and reverse modeling technology was used to build a digital 3D model of an auricle. The transplant process was simulated in ANSYS Workbench by finite element analysis (FEA), solid...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.08.032

    authors: Jiang T,Shang J,Tang L,Wang Z

    更新日期:2016-01-01 00:00:00

  • Viscoelastic parameter identification of human brain tissue.

    abstract::Understanding the constitutive behavior of the human brain is critical to interpret the physical environment during neurodevelopment, neurosurgery, and neurodegeneration. A wide variety of constitutive models has been proposed to characterize the brain at different temporal and spatial scales. Yet, their model paramet...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.07.014

    authors: Budday S,Sommer G,Holzapfel GA,Steinmann P,Kuhl E

    更新日期:2017-10-01 00:00:00

  • Impact of the testing protocol on the mechanical characterization of small diameter electrospun vascular grafts.

    abstract:AIM:For the proper function of small diameter vascular grafts their mechanical properties are essential. A variety of testing methods and protocols exists to measure tensile strength, compliance and viscoelastic material behavior. In this study the impact of the measurement protocol in hoop tensile tests on the measure...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103652

    authors: Stoiber M,Grasl C,Frieberger K,Moscato F,Bergmeister H,Schima H

    更新日期:2020-04-01 00:00:00

  • Micromechanisms of fatigue crack growth in polycarbonate polyurethane: Time dependent and hydration effects.

    abstract::Polycarbonate polyurethane has cartilage-like, hygroscopic, and elastomeric properties that make it an attractive material for orthopedic joint replacement application. However, little data exists on the cyclic loading and fracture behavior of polycarbonate polyurethane. This study investigates the mechanisms of fatig...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.01.008

    authors: Ford AC,Gramling H,Li SC,Sov JV,Srinivasan A,Pruitt LA

    更新日期:2018-03-01 00:00:00

  • Biocompatibility and compressive properties of Ti-6Al-4V scaffolds having Mg element.

    abstract::Porous scaffolds of Ti-6Al-4V were produced by mixing of this alloy with different amount of magnesium (Mg) powders. The mixtures were compacted in steel die by applying uniaxial pressure of 500 MPa before sintering the compacts in sealed quartz tubes at 900 °C for 2 h. Employing Archimedes׳ principle and Image Tool s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.04.015

    authors: Kalantari SM,Arabi H,Mirdamadi S,Mirsalehi SA

    更新日期:2015-08-01 00:00:00

  • Assessing the microstructural response to applied deformation in porcine passive skeletal muscle.

    abstract::The passive micro-structural mechanical response of muscle tissue is important for numerous medical applications. However, the recently observed tension/compression asymmetry in porcine muscle remains poorly explained. In particular there remains a lack of understanding of how external tension or compression applied i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.08.019

    authors: Takaza M,Cooney GM,McManus G,Stafford P,Simms CK

    更新日期:2014-12-01 00:00:00

  • Fabrication of tissue-engineered tympanic membrane patches using 3D-Printing technology.

    abstract::In recent years, scaffolds produced in 3D printing technology have become more widespread tool due to providing more advantages than traditional methods in tissue engineering applications. In this research, it was aimed to produce patches for the treatment of tympanic membrane perforations which caused significant hea...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104219

    authors: Ilhan E,Ulag S,Sahin A,Yilmaz BK,Ekren N,Kilic O,Sengor M,Kalaskar DM,Oktar FN,Gunduz O

    更新日期:2021-02-01 00:00:00

  • Mechanical properties and thermal behaviour of PEGDMA hydrogels for potential bone regeneration application.

    abstract::Poly(ethylene glycol) hydrogels are currently under investigation as possible scaffold materials for bone regeneration. The main purpose of this research was to analyse the mechanical properties and thermal behaviour of novel photopolymerised poly(ethylene glycol) dimethacrylate (PEGDMA) based hydrogels. The effect of...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.04.004

    authors: Killion JA,Geever LM,Devine DM,Kennedy JE,Higginbotham CL

    更新日期:2011-10-01 00:00:00