Composite electrospun gelatin fiber-alginate gel scaffolds for mechanically robust tissue engineered cornea.

Abstract:

:A severe shortage of good quality donor cornea is now an international crisis in public health. Alternatives for donor tissue need to be urgently developed to meet the increasing demand for corneal transplantation. Hydrogels have been widely used as scaffolds for corneal tissue regeneration due to their large water content, similar to that of native tissue. However, these hydrogel scaffolds lack the fibrous structure that functions as a load-bearing component in the native tissue, resulting in poor mechanical performance. This work shows that mechanical properties of compliant hydrogels can be substantially enhanced with electrospun nanofiber reinforcement. Electrospun gelatin nanofibers were infiltrated with alginate hydrogels, yielding transparent fiber-reinforced hydrogels. Without prior crosslinking, electrospun gelatin nanofibers improved the tensile elastic modulus of the hydrogels from 78±19 kPa to 450±100 kPa. Stiffer hydrogels, with elastic modulus of 820±210 kPa, were obtained by crosslinking the gelatin fibers with carbodiimide hydrochloride in ethanol before the infiltration process, but at the expense of transparency. The developed fiber-reinforced hydrogels show great promise as mechanically robust scaffolds for corneal tissue engineering applications.

authors

Tonsomboon K,Oyen ML

doi

10.1016/j.jmbbm.2013.03.001

subject

Has Abstract

pub_date

2013-05-01 00:00:00

pages

185-94

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(13)00079-9

journal_volume

21

pub_type

杂志文章
  • An experimental analysis of shell failure in breast implants.

    abstract::Breast implant durability and the mechanisms of rupture are important topics in the medical community, for patients, manufactures and regulatory medical agencies. After concerns about the Poly Implant Prosthesis (PIP) implants, the need for understanding the adverse outcomes and the failure mode to improve the breast ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.04.005

    authors: Ramião NG,Martins PS,Barroso ML,Santos DC,Fernandes AA

    更新日期:2017-08-01 00:00:00

  • Mechano-geometrical skeletal muscle fibre characterisation under cyclic and relaxation loading.

    abstract::In the present work, mechano-geometrical characterisations of skeletal muscle fibres in two different deformation states, namely, axial tension and axial compression, were realised. In both cases, cyclic and relaxation tests were performed. Additionally, the changes in the volume of the fibres during deformation were ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104001

    authors: Böl M,Iyer R,Garcés-Schröder M,Kohn S,Dietzel A

    更新日期:2020-10-01 00:00:00

  • Dynamic nanomechanical properties of novel Si-rich intermetallic coatings growth on a medical 316 LVM steel by hot dipping in a hypereutectic Al-25Si alloy.

    abstract::This aim of this study is to determine the elastoplastic properties of Ni-free Al3FeSi2 intermetallic coatings grown on medical stainless steel under different experimental conditions. Elastoplastic properties are defined by the plasticity index (PI), which correlates the hardness and the Young's modulus. Special emph...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.02.018

    authors: Frutos E,González-Carrasco JL

    更新日期:2015-06-01 00:00:00

  • Biomechanical evaluation of laser-etched Ti implant surfaces vs. chemically modified SLA Ti implant surfaces: Removal torque and resonance frequency analysis in rabbit tibias.

    abstract:PURPOSE:To compare osseointegration and implant stability of two types of laser-etched (LE) Ti implants with a chemically-modified, sandblasted, large-grit and acid-etched (SLA) Ti implant (SLActive(®), Straumann, Basel, Switzerland), by evaluating removal torque and resonance frequency between the implant surface and ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.034

    authors: Lee JT,Cho SA

    更新日期:2016-08-01 00:00:00

  • Extrusion of the biodegradable ZnMg0.8Ca0.2 alloy - The influence of extrusion parameters on microstructure and mechanical characteristics.

    abstract::The Zn-based alloys, alloyed with the elements of the 2nd group of the periodic table, are considered as potential biodegradable materials suitable for the fabrication of small orthopaedic implants or cardiovascular stents. Unfortunately, the as-cast Zn-based alloys do not fulfil the requirements for mechanical proper...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103796

    authors: Čapek J,Kubásek J,Pinc J,Drahokoupil J,Čavojský M,Vojtěch D

    更新日期:2020-08-01 00:00:00

  • Poroviscoelastic characterization of particle-reinforced gelatin gels using indentation and homogenization.

    abstract::Hydrogels are promising materials for bioengineering applications, and are good model materials for the study of hydrated biological tissues. As these materials often have a structural function, the measurement of their mechanical properties is of fundamental importance. In the present study gelatin gels reinforced wi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.01.009

    authors: Galli M,Fornasiere E,Cugnoni J,Oyen ML

    更新日期:2011-05-01 00:00:00

  • Hyper-frequency viscoelastic spectroscopy of biomaterials.

    abstract::With the emergence of new biomaterials and elastography imaging techniques, there is a need for innovative instruments dedicated to viscoelasticity measurements. In this work, we introduce a novel hyper-frequency viscoelastic spectroscopy (HFVS) technique dedicated to characterize soft media subjected to mid-to-very-h...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.03.020

    authors: Hadj Henni A,Schmitt C,Tremblay MÉ,Hamdine M,Heuzey MC,Carreau P,Cloutier G

    更新日期:2011-10-01 00:00:00

  • Role of porosity and matrix behavior on compressive fracture of Haversian bone using random spring network model.

    abstract::Haversian remodeling is known to result in improved resistance to compressive fracture in healthy cortical bone. Here, we examine the individual roles of the mean porosity, structure of the network of pores and remodeled bone matrix properties in the fracture behavior of Haversian bone. The detailed structure of poros...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.04.013

    authors: Mayya A,Banerjee A,Rajesh R

    更新日期:2018-07-01 00:00:00

  • Structural analysis of rat bone explants kept in vitro in simulated microgravity conditions.

    abstract::Skeletal abnormalities reported in humans and laboratory animals after spaceflight, include cancellous osteopenia, decreased cortical and cancellous bone formation, aberrant matrix ultrastructure, decreased mineralization and reduced bone strength. Although considerable effort has been made up to now to understand the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2008.06.004

    authors: Cosmi F,Steimberg N,Dreossi D,Mazzoleni G

    更新日期:2009-04-01 00:00:00

  • Synthesis of imidazolium-containing mono-methacrylates as polymerizable antibacterial agents for acrylic bone cements.

    abstract::With the aim to prepare antibacterial acrylic bone cements, a series of imidazolium-containg mono-methacrylates with N-alkyl chain length varied from 10 to 18 (MEIM-x) were synthesized as polymerizable antibacterial agents through a two-step reaction. The structures of the monomers were confirmed by 1H NMR. Methyl met...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.06.003

    authors: Zhu W,Liu F,He J

    更新日期:2017-10-01 00:00:00

  • Wear characteristics of WSU total ankle replacement devices under shear and torsion loads.

    abstract:BACKGROUND:There are several factors that contribute to the failure of total ankle replacement (TAR). Aseptic loosening is one of the primary mechanisms of failure in TAR. Since a cross-linked ultrahigh molecular weight polyethylene (UHMWPE) is used as liner material, there is a need to quantify and develop methods to ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.12.010

    authors: Gundapaneni D,Tsatalis JT,Laughlin RT,Goswami T

    更新日期:2015-04-01 00:00:00

  • A novel prime-&-rinse mode using MDP and MMPs inhibitors improves the dentin bond durability of self-etch adhesive.

    abstract:OBJECTIVES:The study investigated the effects of novel prime-&-rinse mode using MDP (10-methacryloyloxydecyl dihydrogenphosphate) and matrix metalloproteinase (MMPs) inhibitors on dentin microtensile bond strengths (MTBS) of self-etch adhesive, resin-dentin interface degradations, and activity of recombinant human (rh)...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103698

    authors: Xu J,Li M,Wang W,Wu Z,Wang C,Jin X,Zhang L,Jiang W,Fu B

    更新日期:2020-04-01 00:00:00

  • Fabrication, tribological and corrosion behaviors of ultra-fine grained Co-28Cr-6Mo alloy for biomedical applications.

    abstract::Nickel and carbides free Co-28Cr-6Mo alloy was fabricated by combination of mechanical alloying and warm pressing. The microstructure, mechanical properties, pin-on-disk dry sliding wear and corrosion behavior in simulated physiological solution were investigated. The produced Co-28Cr-6Mo alloy has elongated ultra-fin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.039

    authors: Ren F,Zhu W,Chu K

    更新日期:2016-07-01 00:00:00

  • A projection method to extract biological membrane models from 3D material models.

    abstract::This paper presents a projection method for deriving membrane models from the corresponding three-dimensional material models. As a particular example the anisotropic Holzapfel-Gasser-Ogden model is considered. The projection procedure is based on the kinematical and constitutive assumptions of a general membrane theo...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.09.001

    authors: Roohbakhshan F,Duong TX,Sauer RA

    更新日期:2016-05-01 00:00:00

  • Interfacial indentations in biological composites.

    abstract::Biocomposites comprise highly stiff reinforcement elements connected by a compliant matrix material. While the interfacial elastic properties of these biocomposites play a key role in determining the mechanical properties of the entire biocomposite, these properties cannot be measured directly from standard nanomechan...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104209

    authors: Shelef Y,Bar-On B

    更新日期:2021-02-01 00:00:00

  • Setting mechanism of a new injectable Dicalcium Phosphate Dihydrate (DCPD) forming cement.

    abstract::We previously described the gelation mechanism of calcium polyphosphate (CPP) in the presence of water. In this study, we developed novel and injectable poly-dicalcium phosphate dihydrate (P-DCPD) forming cement by the reaction of acidic CPP gel with alkali tetracalcium phosphate (TTCP). The setting reaction mechanism...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.12.032

    authors: Ren W,Song W,Yurgelevic S,Markel DC

    更新日期:2018-03-01 00:00:00

  • RETRACTED: Mechanical properties and phase transition of biomedical titanium alloy strips with initial quasi-single phase state under high-energy electropulses.

    abstract::This article has been retracted: please see Elsevier Policy on Article Withdrawal (http://www.elsevier.com/locate/withdrawalpolicy). This article has been retracted at the request of the Editor-in-Chief. The authors have reused figures and text that have already appeared in their previous articles. Figure 4 duplicat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,收录出版

    doi:10.1016/j.jmbbm.2014.11.009

    authors: Ye X,Tse ZT,Tang G,Song G

    更新日期:2015-02-01 00:00:00

  • Is short term intraoperative application of disinfectants harmful to breast implants in breast reconstruction? An experimental study and literature survey.

    abstract:OBJECTIVES:Bacterial contamination of breast implants and biofilm formation has been discussed as a major reason for implant loss and capsular contraction. Intra- and perioperative treatment of breast implants with disinfectants to prevent bacterial contamination has been frequently reported. Given the increasing aware...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.10.021

    authors: Schmitz M,Schubert DW,Kaschta J,Daenicke J,Walter BL,Horch RE

    更新日期:2019-02-01 00:00:00

  • Collagen tissue treated with chitosan solution in H2O/CO2 mixtures: Influence of clathrates hydrates on the structure and mechanical properties.

    abstract::A mixture of water/carbon dioxide is a "green" perspective solvent from the viewpoint of biomedical applications. Clathrate hydrates are formed this solvent under certain conditions and a very interesting question is the impact of clathrates hydrates on the structure and properties of bovine pericardium, which is used...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.11.015

    authors: Chaschin IS,Bakuleva NP,Grigoriev TE,Krasheninnikov SV,Nikitin LN

    更新日期:2017-03-01 00:00:00

  • A statistical approach to understand the role of inclusions on the fatigue resistance of superelastic Nitinol wire and tubing.

    abstract::Superelastic wires and diamond-shaped stent surrogates were manufactured from Nitinol rods and tubing, respectively, from five different mill product suppliers - Standard VAR, Standard VIM, Standard VIM+VAR, Process-Optimized VIM+VAR, and High-Purity VAR. High-cycle fatigue tests up to 10(7) cycles were conducted unde...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.07.003

    authors: Robertson SW,Launey M,Shelley O,Ong I,Vien L,Senthilnathan K,Saffari P,Schlegel S,Pelton AR

    更新日期:2015-11-01 00:00:00

  • Development of novel zirconia implant's materials gradated design with improved bioactive surface.

    abstract::Zirconia implants are becoming a preference choice for different applications such as knee, dental, among others. In order to improve osseointegration, implant's surfaces are usually coated with bioactive materials like hydroxyapatite (HAp) and beta-tricalcium phosphate (β-TCP) that are very similar to the calcium pho...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.02.022

    authors: Faria D,Pires JM,Boccaccini AR,Carvalho O,Silva FS,Mesquita-Guimarães J

    更新日期:2019-06-01 00:00:00

  • Influence of structural load-bearing scaffolds on mechanical load- and BMP-2-mediated bone regeneration.

    abstract::A common design constraint in functional tissue engineering is that scaffolds intended for use in load-bearing sites possess similar mechanical properties to the replaced tissue. Here, we tested the hypothesis that in vivo loading would enhance bone morphogenetic protein-2 (BMP-2)-mediated bone regeneration in the pre...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.010

    authors: McDermott AM,Mason DE,Lin ASP,Guldberg RE,Boerckel JD

    更新日期:2016-09-01 00:00:00

  • Effect of collagen packing and moisture content on leather stiffness.

    abstract::Applications for skin derived collagen materials, such as leather and acellular dermal matrices, usually require both strength and flexibility. In general, both the tensile modulus (which has an impact on flexibility) and strength are known to increase with fiber alignment, in the tensile direction, for practically al...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.10.004

    authors: Kelly SJR,Weinkamer R,Bertinetti L,Edmonds RL,Sizeland KH,Wells HC,Fratzl P,Haverkamp RG

    更新日期:2019-02-01 00:00:00

  • Microstructural features influencing the mechanical performance of the Brazil nut (Bertholletia excelsa) mesocarp.

    abstract::Brazil nut (Bertholletia excelsa) fruits are capable of resisting high mechanical forces when released from trees as tall as 50 m, as well as during animal dispersal by sharp-teethed rodents. Thick mesocarp plays a crucial part in seed protection. We investigated the role of microstructure and how sclereids, fibers, a...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104306

    authors: Sonego M,Madia M,Eder M,Fleck C,Pessan LA

    更新日期:2021-01-07 00:00:00

  • Evaluation of surface roughness, hardness and elastic modulus of nanoparticle containing light-polymerized denture glaze materials.

    abstract:STATEMENT OF PROBLEM:The surface hardness and roughness of different glaze materials for denture base acrylic resins have not been well reported. PURPOSE:The purpose of the study was to measure the surfaces hardness, elastic modulus and surface roughness of 5 different light-polymerized glaze materials for poly methyl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103601

    authors: Choi JJE,Uy CE,Ramani RS,Waddell JN

    更新日期:2020-03-01 00:00:00

  • Single and reciprocal friction testing of micropatterned surfaces for orthopedic device design.

    abstract::The use of micropatterning to create uniform surface morphologies has been cited as yielding improvements in the coefficient of friction during high velocity sliding contact. Studies have not been preformed to determine if these micropatterns could also be useful in biomedical applications, such as total joint replace...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.08.022

    authors: Mitchell N,Eljach C,Lodge B,Sharp JL,Desjardins JD,Kennedy MS

    更新日期:2012-03-01 00:00:00

  • Biomechanics of infarcted left Ventricle-A review of experiments.

    abstract::Myocardial infarction (MI) is one of leading diseases to contribute to annual death rate of 5% in the world. In the past decades, significant work has been devoted to this subject. Biomechanics of infarcted left ventricle (LV) is associated with MI diagnosis, understanding of remodelling, MI micro-structure and biomec...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,评审

    doi:10.1016/j.jmbbm.2019.103591

    authors: Li W

    更新日期:2020-03-01 00:00:00

  • How does lubricant viscosity affect the wear behaviour of VitE-XLPE articulated against CoCr?

    abstract::Using a 50-station pin-on-disc (SuperCTPOD) machine, the influence of lubricant viscosity on the wear of vitamin E blended crosslinked polyethylene was investigated. Five different test lubricants were prepared by mixing different concentrations of carboxymethyl cellulose powder with deionised water. The viscosity ran...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104067

    authors: Kandemir G,Smith S,Chen J,Joyce TJ

    更新日期:2020-12-01 00:00:00

  • Mechanical properties and in vitro bioactivity of injectable and self-setting calcium sulfate/nano-HA/collagen bone graft substitute.

    abstract::Calcium sulfate hemihydrate (CSH) was introduced into the mineralized collagen (nHAC) to prepare an injectable and self-setting in situ bone graft substitute. The mechanical properties of materials, which are dependant on the L/S ratio, the content of nHAC and setting accelerator, were discussed based on the satisfyin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.12.007

    authors: Hu NM,Chen Z,Liu X,Liu H,Lian X,Wang X,Cui FZ

    更新日期:2012-08-01 00:00:00

  • Sensing inhomogeneous mechanical properties of human corneal Descemet's membrane with AFM nano-indentation.

    abstract::The paper describes a highly space-resolved characterization of the surface mechanical properties of the posterior human corneal layer (Descemet's membrane). This has been accomplished with Atomic Force Microscopy (AFM) nano-indentation by using a probe with a sharp tip geometry. Results indicate that the contact with...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.05.019

    authors: Di Mundo R,Recchia G,Parekh M,Ruzza A,Ferrari S,Carbone G

    更新日期:2017-10-01 00:00:00