Biomechanical evaluation of laser-etched Ti implant surfaces vs. chemically modified SLA Ti implant surfaces: Removal torque and resonance frequency analysis in rabbit tibias.

Abstract:

PURPOSE:To compare osseointegration and implant stability of two types of laser-etched (LE) Ti implants with a chemically-modified, sandblasted, large-grit and acid-etched (SLA) Ti implant (SLActive(®), Straumann, Basel, Switzerland), by evaluating removal torque and resonance frequency between the implant surface and rabbit tibia bones. We used conventional LE Ti implants (conventional LE implant, CSM implant, Daegu, Korea) and LE Ti implants that had been chemically activated with 0.9% NaCl solution (LE active implant) for comparison with SLActive(®) implants MATERIALS AND METHODS:Two types of 3.3×8mm laser-etched Ti implants - conventional LE implants and LE active implants were prepared. LE implants and SLActive(®) implants were installed on the left and right tibias of 10 adult rabbits weighing approximately 3.0kg LE active implants and SLActive(®) implants were installed on the left and right tibias of 11 adult rabbits. After installation, we measured insertion torque (ITQ) and resonance frequency (ISQ). Three weeks (LE active) or 4 weeks (conventional LE) after installation, we measured removal torque (RTQ) and ISQ. RESULTS:In the conventional LE experiment, the mean ITQ was 16.99±6.35Ncm for conventional LE implants and 16.11±7.36Ncm for SLActive(®) implants (p=0.778>0.05). After 4 weeks, the mean of RTQ was 39.49±17.3Ncm for LE and 42.27±20.5Ncm for SLActive(®) (p=0.747>0.05). Right after insertion of the implants, the mean ISQ was 74.8±4.98 for conventional LE and 70.1±9.15 for SLActive(®) implants (p=0.169>0.05). After 4 weeks, the mean ISQ was 64.40±6.95 for LE and 67.70±9.83 for SLActive(®) (p=0.397>0.05). In the LE active experiment, the mean ITQ was 16.24±7.49Ncm for LE active implants and 14.33±5.06Ncm for SLActive(®) implants (p=0.491>0.05). After 3 weeks, the mean RTQ was 39.25±16.41Ncm for LE active and 41.56±10.41Ncm for SLActive(®) implants (p=0.698>0.05). Right after insertion of the implants, the mean ISQ was 58.64±10.51 for LE active implants and 53.82±15.36 for SLActive(®) implants (p=0.401>0.05). After 3 weeks, the mean ISQ was 63.82±5.88 for LE active and 66.27±6.53 for SLActive(®) (p=0.365>0.05). CONCLUSION:We observed no significant differences in biomechanical bond strength to bone or implant stability in bone between the conventional LE Ti implant surface and the surface of the SLActive(®) implant or between the chemically activated LE Ti implant surface and the surface of the SLActive(®) implant during the early stage of osseointegration.

authors

Lee JT,Cho SA

doi

10.1016/j.jmbbm.2016.03.034

subject

Has Abstract

pub_date

2016-08-01 00:00:00

pages

299-307

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(16)30064-9

journal_volume

61

pub_type

杂志文章
  • Biomechanical and biochemical protective effect of low-level laser therapy for Achilles tendinitis.

    abstract::For three decades, low level laser therapy (LLLT) has been used for treatment of tendinitis as well as other musculoskeletal diseases. Nevertheless, the biological mechanisms involved remain not completely understood. In this work, the effects of LLLT and of the widely used nonsteroidal anti-inflammatory drug, diclofe...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.028

    authors: Marcos RL,Arnold G,Magnenet V,Rahouadj R,Magdalou J,Lopes-Martins RÁ

    更新日期:2014-01-01 00:00:00

  • Analysis of behind the armor ballistic trauma.

    abstract::The impact response of body armor composed of a ceramic plate with an ultrahigh molecular weight polyethylene (UHMWPE) fiber-reinforced composite and layers of UHMWPE fibers shielding a block of ballistic gelatin has been experimentally and numerically analyzed. It is a surrogate model for studying injuries to human t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.01.010

    authors: Wen Y,Xu C,Wang S,Batra RC

    更新日期:2015-05-01 00:00:00

  • Evaluation of surface roughness, hardness and elastic modulus of nanoparticle containing light-polymerized denture glaze materials.

    abstract:STATEMENT OF PROBLEM:The surface hardness and roughness of different glaze materials for denture base acrylic resins have not been well reported. PURPOSE:The purpose of the study was to measure the surfaces hardness, elastic modulus and surface roughness of 5 different light-polymerized glaze materials for poly methyl...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103601

    authors: Choi JJE,Uy CE,Ramani RS,Waddell JN

    更新日期:2020-03-01 00:00:00

  • Correlations between transmural mechanical and morphological properties in porcine thoracic descending aorta.

    abstract::Determination of correlations between transmural mechanical and morphological properties of aorta would provide a quantitative baseline for assessment of preventive and therapeutic strategies for aortic injuries and diseases. A multimodal and multidisciplinary approach was adopted to characterize the transmural morpho...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.004

    authors: Hemmasizadeh A,Tsamis A,Cheheltani R,Assari S,D'Amore A,Autieri M,Kiani MF,Pleshko N,Wagner WR,Watkins SC,Vorp D,Darvish K

    更新日期:2015-07-01 00:00:00

  • Sub-10-micrometer toughening and crack tip toughness of dental enamel.

    abstract::In previous studies, enamel showed indications to occlude small cracks in-vivo and exhibited R-curve behaviors for bigger cracks ex-vivo. This study quantifies the crack tip's toughness (K(I0),K(III0)), the crack's closure stress and the cohesive zone size at the crack tip of enamel and investigates the toughening mec...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2010.12.003

    authors: Ang SF,Schulz A,Pacher Fernandes R,Schneider GA

    更新日期:2011-04-01 00:00:00

  • Damage mechanisms in uniaxial compression of single enamel rods.

    abstract::Enamel possesses a complex hierarchical structure, which bestows this tissue with unique mechanical properties. In this study, the mechanical behavior of single enamel rods was investigated under uniaxial compression. Numerical simulations were also performed using micromechanics models for individual enamel rods to i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.10.014

    authors: An B,Wang R,Arola D,Zhang D

    更新日期:2015-02-01 00:00:00

  • Fracture origins in twenty-two dental alumina crowns.

    abstract:OBJECTIVES:The causes of in vivo fractures of all-ceramic dental crowns are not yet fully understood. The fracture origins often occur in the cervical margin in the approximal area, but the reason for this is unclear. The aim of this study was to evaluate the fracture origin of 22 of clinically-failed alumina crowns. ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.08.006

    authors: Øilo M,Quinn GD

    更新日期:2016-01-01 00:00:00

  • Fabrication of tissue-engineered tympanic membrane patches using 3D-Printing technology.

    abstract::In recent years, scaffolds produced in 3D printing technology have become more widespread tool due to providing more advantages than traditional methods in tissue engineering applications. In this research, it was aimed to produce patches for the treatment of tympanic membrane perforations which caused significant hea...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104219

    authors: Ilhan E,Ulag S,Sahin A,Yilmaz BK,Ekren N,Kilic O,Sengor M,Kalaskar DM,Oktar FN,Gunduz O

    更新日期:2021-02-01 00:00:00

  • The High performance of nanocrystalline CVD diamond coated hip joints in wear simulator test.

    abstract::The superior biotribological performance of nanocrystalline diamond (NCD) coatings grown by a chemical vapor deposition (CVD) method was already shown to demonstrate high wear resistance in ball on plate experiments under physiological liquid lubrication. However, tests with a close-to-real approach were missing and t...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.005

    authors: Maru MM,Amaral M,Rodrigues SP,Santos R,Gouvea CP,Archanjo BS,Trommer RM,Oliveira FJ,Silva RF,Achete CA

    更新日期:2015-09-01 00:00:00

  • Hybrid micro/nanostructural surface offering improved stress distribution and enhanced osseointegration properties of the biomedical titanium implant.

    abstract:OBJECTIVES:The aim of the present study was to investigate the surface characteristic, biomechanical behavior, hemocompatibility, bone tissue response and osseointegration of the optimal micro-arc oxidation surface-treated titanium (MST-Ti) dental implant. MATERIALS AND METHODS:The surface characteristic, biomechanica...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.11.042

    authors: Hou PJ,Ou KL,Wang CC,Huang CF,Ruslin M,Sugiatno E,Yang TS,Chou HH

    更新日期:2018-03-01 00:00:00

  • Osteogenesis enhancement of silk fibroin/ α-TCP cement by N-acetyl cysteine through Wnt/β-catenin signaling pathway in vivo and vitro.

    abstract::High brittleness and lack osteogenesis are two major limitations of calcium phosphate cement (CPC) in application in bone defect reconstruction. Here we prepared a composite calcium phosphate cement by mixing N-acetyl cysteine loaded silk fibroin solution with α-tricalcium phosphate. In vitro cytology experiment revea...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103451

    authors: Feng T,Niu J,Pi B,Lu Y,Wang J,Zhang W,Li B,Yang H,Zhu X

    更新日期:2020-01-01 00:00:00

  • Fatigue and durability of Nitinol stents.

    abstract::Nitinol self-expanding stents are effective in treating peripheral artery disease, including the superficial femoral, carotid, and renal arteries. However, fracture occurrences of up to 50% have been reported in some stents after one year. These stent fractures are likely due to in vivo cyclic displacements. As such, ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2007.08.001

    authors: Pelton AR,Schroeder V,Mitchell MR,Gong XY,Barney M,Robertson SW

    更新日期:2008-04-01 00:00:00

  • Effect of alumina contents on phase stability and mechanical properties of magnesium fluorapatite/alumina composites.

    abstract::The aim of the present work was twofold: to prepare biphasic magnesium fluorapatite (MFA) composites with different amounts of alumina using a two-step sintering process, and to evaluate the effects of various amounts of alumina on the mechanical properties, phase stability, and densification of the composite samples....

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.08.004

    authors: Hejazi MS,Ahmadian M,Meratian M,Fathi MH

    更新日期:2014-12-01 00:00:00

  • Fatigue behavior of Ti6Al4V and 316 LVM blasted with ceramic particles of interest for medical devices.

    abstract::Grit blasting is used as a cost-effective method to increase the surface roughness of metallic biomaterials, as Ti6Al4V and 316 LVM, to enhance the osteointegration, fixation and stability of implants. Samples of these two alloys were blasted by using alumina and zirconia particles, yielding rough (up to Ra~8μm) and n...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.10.013

    authors: Barriuso S,Chao J,Jiménez JA,García S,González-Carrasco JL

    更新日期:2014-02-01 00:00:00

  • An interpenetrating network composite for a regenerative spinal disc application.

    abstract::Severe degeneration of the intervertebral disc has an immensely debilitating effect on quality of life that has become a serious health and economic burden throughout the world. The disc plays an integral role in biomechanical movement and support within the spine. The emergence of tissue engineering endeavours to res...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.10.015

    authors: Chan AH,Boughton PC,Ruys AJ,Oyen ML

    更新日期:2017-01-01 00:00:00

  • Biomechanics of stomach tissues and structure in patients with obesity.

    abstract::Even though bariatric surgery is one of the most effective treatment option of obesity, post-surgical weight loss is not always ensured, especially in the long term, when many patients experience weight regain. Bariatric procedures are largely based on surgeon's expertise and intra-operative decisions, while an integr...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103883

    authors: Carniel EL,Albanese A,Fontanella CG,Pavan PG,Prevedello L,Salmaso C,Todros S,Toniolo I,Foletto M

    更新日期:2020-10-01 00:00:00

  • The relevance of molecular weight in the design of amorphous biodegradable polymers with optimized shape memory effect.

    abstract::The shape memory effect (SME) has long been the focus of interest of many research groups that have studied many facets of it, yet to the authors' knowledge some molecular parameters, such as the molecular weight, have been skipped. Thus, the aim of this work is to offer further insight into the shape memory effect, b...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.04.027

    authors: Petisco-Ferrero S,Fernández J,Fernández San Martín MM,Santamaría Ibarburu PA,Sarasua Oiz JR

    更新日期:2016-08-01 00:00:00

  • Microstructure, mechanical property and metal release of As-SLM CoCrW alloy under different solution treatment conditions.

    abstract::In the study, the microstructure, mechanical property and metal release behavior of selective laser melted CoCrW alloys under different solution treatment conditions were systemically investigated to assess their potential use in orthopedic implants. The effects of the solution treatment on the microstructure, mechani...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.10.019

    authors: Lu Y,Wu S,Gan Y,Zhang S,Guo S,Lin J,Lin J

    更新日期:2015-03-01 00:00:00

  • Characterization of the mechanical behaviors and bioactivity of tetrapod ZnO whiskers reinforced bioactive glass/gelatin composite scaffolds.

    abstract::The purpose of this study is to construct bone tissue engineering scaffold with high porosity, good mechanical properties, and biological activities. Bioactive glass/gelatin composite scaffolds with different amounts of tetrapod zinc oxide whiskers were produced. The morphology, mechanical properties and in vitro bioa...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.01.032

    authors: Guo W,Zhao F,Wang Y,Tang J,Chen X

    更新日期:2017-04-01 00:00:00

  • Tissue mechanics of piled critical size biomimetic and biominerizable nanocomposites: Formation of bioreactor-induced stem cell gradients under perfusion and compression.

    abstract:BACKGROUND:Perfusion bioreactors are used to solve problems in critical size bone tissue engineering. Biominerizable and biocompatible nanocomposites are suitable scaffold materials for this purpose because they offer mineral components in organic carriers. Human adipose derived stem cells (ASCs) can potentially be use...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.03.022

    authors: Baumgartner W,Welti M,Hild N,Hess SC,Stark WJ,Bürgisser GM,Giovanoli P,Buschmann J

    更新日期:2015-07-01 00:00:00

  • Imprecise knowledge based design and development of titanium alloys for prosthetic applications.

    abstract::Imprecise knowledge on the composition-processing-microstructure-property correlation of titanium alloys combined with experimental data are used for developing rule based models for predicting the strength and elastic modulus of titanium alloys. The developed models are used for designing alloys suitable for orthoped...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.08.039

    authors: Datta S,Mahfouf M,Zhang Q,Chattopadhyay PP,Sultana N

    更新日期:2016-01-01 00:00:00

  • On the effect of calcification volume and configuration on the mechanical behaviour of carotid plaque tissue.

    abstract::Vascular calcification is a complex molecular process that exhibits a number of relatively characteristic morphology patterns in atherosclerotic plaques. Treatment of arterial stenosis by endovascular intervention, involving forceful circumferential expansion of the plaque, can be unpredictable in calcified lesions. T...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.11.001

    authors: Barrett HE,Cunnane EM,Kavanagh EG,Walsh MT

    更新日期:2016-03-01 00:00:00

  • Variation of the superelastic properties and nickel release from original and reused NiTi orthodontic archwires.

    abstract::Reuse of NiTi orthodontic wires has become increasingly common in dental clinics. For sterilization and recovery of the original superelastic properties of the wires, a heat treatment is usually performed between 500 and 600 °C. The aim of this study was to analyze the effect of these thermal treatments on the mechani...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.11.005

    authors: Gil FJ,Espinar E,Llamas JM,Manero JM,Ginebra MP

    更新日期:2012-02-01 00:00:00

  • Influence of Si addition on the microstructure and mechanical properties of Ti-35Nb alloy for applications in orthopedic implants.

    abstract::In the development of new materials for orthopedic implants, special attention has been given to Ti alloys that show biocompatible alloy elements and that are capable of reducing the elastic modulus. Accordingly, Ti-Nb-Si alloys show great potential for application. Thus, this is a study on the microstructures and pro...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.06.035

    authors: Tavares AM,Ramos WS,de Blas JC,Lopes ES,Caram R,Batista WW,Souza SA

    更新日期:2015-11-01 00:00:00

  • Effect of cell sample size in atomic force microscopy nanoindentation.

    abstract::Single-cell technologies are powerful tools to evaluate cell characteristics. In particular, Atomic Force Microscopy (AFM) nanoindentation experiments have been widely used to study single cell mechanical properties. One important aspect related to single cell techniques is the need for sufficient statistical power to...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.018

    authors: Marcotti S,Reilly GC,Lacroix D

    更新日期:2019-06-01 00:00:00

  • Ratcheting behavior of UHMWPE reinforced by carbon nanofibers (CNF) and hydroxyapatite (HA): Experiment and simulation.

    abstract::Uniaxial tensile tests were performed to investigate the mechanical properties of the ultra-high molecular weight polyethylene (UHMWPE) with different modification conditions. It was found that the different modification conditions have great influence on the mechanical properties of the UHMWPE. Subsequently, the unia...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.08.022

    authors: Wang J,Gao H,Gao L,Cui Y,Song Z

    更新日期:2018-12-01 00:00:00

  • Cervical fusion cage computationally optimized with porous architected Titanium for minimized subsidence.

    abstract::Anterior cervical discectomy with fusion is a common surgical treatment that can relieve patients suffering from cervical spondylosis. This surgery is most commonly performed with the use of a cervical cage. One serious complication of the fusion cages commercially available in the market is subsidence of the cage wit...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.05.040

    authors: Moussa A,Tanzer M,Pasini D

    更新日期:2018-09-01 00:00:00

  • Failure analysis of the fractured wires in sternal perichronal loops.

    abstract::We report failure analysis of sternal wires in two cases in which a perichronal fixation technique was used to close the sternotomy. Various characteristics of the retrieved wires were compared to those of unused wires of the same grade and same manufacturer and with surgical wire specifications. In both cases, wire f...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.02.015

    authors: Chao J,Voces R,Peña C

    更新日期:2011-10-01 00:00:00

  • Utilization of a robotic mount to determine the force required to cut palatal tissue.

    abstract::Determination of the material properties of soft tissue is a growing area of interest that aids in the development of new surgical tools and surgical simulators. This study first aims to develop a robot-operated tissue testing system for determination of tissue cutting forces. Second, this system was used to ascertain...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.06.010

    authors: Sorouri K,Podolsky DJ,Wang AMQ,Fisher DM,Wong KW,Looi T,Drake JM,Forrest CR

    更新日期:2018-10-01 00:00:00

  • Sensing inhomogeneous mechanical properties of human corneal Descemet's membrane with AFM nano-indentation.

    abstract::The paper describes a highly space-resolved characterization of the surface mechanical properties of the posterior human corneal layer (Descemet's membrane). This has been accomplished with Atomic Force Microscopy (AFM) nano-indentation by using a probe with a sharp tip geometry. Results indicate that the contact with...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.05.019

    authors: Di Mundo R,Recchia G,Parekh M,Ruzza A,Ferrari S,Carbone G

    更新日期:2017-10-01 00:00:00