Looped ends versus open ends braided stent: A comparison of the mechanical behaviour using analytical and numerical methods.

Abstract:

:The present study has two major purposes: firstly, to investigate whether the analytical model proposed by Jedwab and Clerc for assessing the mechanical behaviour of an open ends metallic braided stent is applicable to the looped ends stent design and secondly, to compare the response of the two stent designs subjected to radial compression. We use finite element analysis to evaluate the performance of the two braided stents emulating well established designs: WALLSTENT and WallFlex. We validate the WALLSTENT model analytically. We perform a radial crimping simulation and evaluate the radial forces and stresses induced. This study confirms the validity of using the analytical model in the biomechanical analysis of the WALLSTENT design. However, in case of the WallFlex design, a major difference in the results can be observed in the levels of radial forces and wire peak stresses, justifying the decision of using a different alloy in the fabrication of the WallFlex design.

authors

Shanahan C,Tiernan P,Tofail SAM

doi

10.1016/j.jmbbm.2017.08.025

subject

Has Abstract

pub_date

2017-11-01 00:00:00

pages

581-591

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(17)30367-3

journal_volume

75

pub_type

杂志文章
  • A method and a device for the evaluation of the retention of telescopic dental crowns.

    abstract::Telescopic crowns are used as support for removable dental prostheses' construction. A distinctive feature of crowns often used in their description and comparison is retention, which is understood as resistance when removing the prosthesis or a force needed to disconnect crowns. The article describes a method for the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.01.042

    authors: Majcher A,Leśniewska-Kochanek A,Mierzwińska-Nastalska E

    更新日期:2017-05-01 00:00:00

  • Mechanical properties and in vitro bioactivity of injectable and self-setting calcium sulfate/nano-HA/collagen bone graft substitute.

    abstract::Calcium sulfate hemihydrate (CSH) was introduced into the mineralized collagen (nHAC) to prepare an injectable and self-setting in situ bone graft substitute. The mechanical properties of materials, which are dependant on the L/S ratio, the content of nHAC and setting accelerator, were discussed based on the satisfyin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.12.007

    authors: Hu NM,Chen Z,Liu X,Liu H,Lian X,Wang X,Cui FZ

    更新日期:2012-08-01 00:00:00

  • Evaluation of experimental, analytical, and computational methods to determine long-bone bending stiffness.

    abstract::Methods used to evaluate bone mechanical properties vary widely depending on the motivation and environment of individual researchers, clinicians, and industries. Further, the innate complexity of bone makes validation of each method difficult. Thus, the purpose of the present research was to quantify methodological e...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104253

    authors: Collins CJ,Yang B,Crenshaw TD,Ploeg HL

    更新日期:2021-03-01 00:00:00

  • Mechano-rheological properties of the murine thrombus determined via nanoindentation and finite element modeling.

    abstract::Deep vein thrombosis, pulmonary embolism, and abdominal aortic aneurysms are blood-related diseases that represent a major public health problem. These diseases are characterized by the formation of a thrombus (i.e., blood clot) that either blocks a major artery or causes an aortic rupture. Identifying the mechanical ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.02.012

    authors: Slaboch CL,Alber MS,Rosen ED,Ovaert TC

    更新日期:2012-06-01 00:00:00

  • Biocompatibility and compressive properties of Ti-6Al-4V scaffolds having Mg element.

    abstract::Porous scaffolds of Ti-6Al-4V were produced by mixing of this alloy with different amount of magnesium (Mg) powders. The mixtures were compacted in steel die by applying uniaxial pressure of 500 MPa before sintering the compacts in sealed quartz tubes at 900 °C for 2 h. Employing Archimedes׳ principle and Image Tool s...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.04.015

    authors: Kalantari SM,Arabi H,Mirdamadi S,Mirsalehi SA

    更新日期:2015-08-01 00:00:00

  • Evaluation of four surface coating treatments for resin to zirconia bonding.

    abstract:OBJECTIVES:To compare the effects of four surface coating methods on resin to zirconia shear bond strength. MATERIAL AND METHODS:Eighty pre-sintered zirconia discs were prepared and randomly divided into five study groups according to the corresponding methods of surface treatments as follows: group C (control group, ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.12.011

    authors: Liu D,Pow EHN,Tsoi JK,Matinlinna JP

    更新日期:2014-04-01 00:00:00

  • Layer-specific residual deformations and uniaxial and biaxial mechanical properties of thoracic porcine aorta.

    abstract::In this paper we hypothesize that the layer-separated residual stresses and mechanical properties of layer-separated thoracic aorta arteries may be dependent on arterial location of the vessel. To demonstrate any possible position differences, we measured the axial pre-stretch and opening angle and performed uniaxial ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.024

    authors: Peña JA,Martínez MA,Peña E

    更新日期:2015-10-01 00:00:00

  • Finite element simulation for the mechanical characterization of soft biological materials by atomic force microscopy.

    abstract::The characterization of the mechanical properties of soft materials has been traditionally performed through uniaxial tensile tests. Nevertheless, this method cannot be applied to certain extremely soft materials, such as biological tissues or cells that cannot be properly subjected to these tests. Alternative non-des...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.006

    authors: Valero C,Navarro B,Navajas D,García-Aznar JM

    更新日期:2016-09-01 00:00:00

  • Modeling failure of soft anisotropic materials with application to arteries.

    abstract::The arterial wall is a composite where the preferred orientation of collagen fibers induces anisotropy. Though the hyperelastic theories of fiber-reinforced composites reached a high level of sophistication and showed a reasonable correspondence with the available experimental data they are short of the failure descri...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.01.002

    authors: Volokh KY

    更新日期:2011-11-01 00:00:00

  • Mechanical behaviour of pressed and sintered titanium alloys obtained from master alloy addition powders.

    abstract::The fabrication of the workhorse Ti-6Al-4V alloy and of the Ti-3Al-2.5V alloy was studied considering the master alloy addition variant of the blending elemental approach conventionally used for titanium powder metallurgy. The powders were characterised by means thermal analysis and X-ray diffraction and shaped by mea...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.05.019

    authors: Bolzoni L,Esteban PG,Ruiz-Navas EM,Gordo E

    更新日期:2012-11-01 00:00:00

  • Experimental and constitutive modeling approaches for a study of biomechanical properties of human coronary arteries.

    abstract::The study concerns the determination of mechanical properties of human coronary arterial walls with both experimental and constitutive modeling approaches. The research material was harvested from 18 patients (range 50-84 years). On the basis of hospital records and visual observation, each tissue sample was classifie...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.05.021

    authors: Jankowska MA,Bartkowiak-Jowsa M,Bedzinski R

    更新日期:2015-10-01 00:00:00

  • Bite force mechanics and allometry of piranha (Serrasalmidae).

    abstract::The bite force of the piranha (Serrasalmidae) has drawn considerable attention due to its ability to effectively capture and masticate prey. Herein, we analyze theoretical anterior bite forces using a lever approach and compare them to in-vivo maximum bite forces. We provide a mechanics analysis that explains the scal...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.104296

    authors: Velasco-Hogan A,Meyers MA

    更新日期:2021-03-01 00:00:00

  • Comparison of structural anisotropic soft tissue models for simulating Achilles tendon tensile behaviour.

    abstract::The incidence of tendon injury (tendinopathy) has increased over the past decades due to greater participation in sports and recreational activities. But little is known about the aetiology of tendon injuries because of our limited knowledge in the complex structure-function relationship in tendons. Computer models ca...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.04.007

    authors: Khayyeri H,Longo G,Gustafsson A,Isaksson H

    更新日期:2016-08-01 00:00:00

  • Evaluating thoracolumbar spine response during simulated underbody blast impact using a total human body finite element model.

    abstract::In a study of spine injuries in Operation Iraqi Freedom (OIF) and Operation Enduring Freedom (OEF) from 2001-09, spinal fractures sustained by mounted soldiers accounted for 26% of all injuries, and of that, 43% were caused by explosions [1]. The thoracolumbar region is the most vulnerable area of the spine [2], and i...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103398

    authors: Somasundaram K,Zhang L,Sherman D,Begeman P,Lyu D,Cavanaugh JM

    更新日期:2019-12-01 00:00:00

  • Study the bonding mechanism of binders on hydroxyapatite surface and mechanical properties for 3DP fabrication bone scaffolds.

    abstract::In 3DP fabricating artificial bone scaffolds process, the interaction mechanism between binder and bioceramics power determines the microstructure and macro mechanical properties of Hydroxyapatite (HA) bone scaffold. In this study, we applied Molecular Dynamics (MD) methods to investigating the bonding mechanism and e...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.007

    authors: Wei Q,Wang Y,Li X,Yang M,Chai W,Wang K,zhang Y

    更新日期:2016-04-01 00:00:00

  • Evaluation of multi-scale mineralized collagen-polycaprolactone composites for bone tissue engineering.

    abstract::A particular challenge in biomaterial development for treating orthopedic injuries stems from the need to balance bioactive design criteria with the mechanical and geometric constraints governed by the physiological wound environment. Such trade-offs are of particular importance in large craniofacial bone defects whic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.032

    authors: Weisgerber DW,Erning K,Flanagan CL,Hollister SJ,Harley BAC

    更新日期:2016-08-01 00:00:00

  • R-curve behavior of a short-fiber reinforced resin composite after water storage.

    abstract::As a supplement to our investigation into R-curves in a short-fiber reinforced dental resin composite, we investigate the effects of 2-months water storage. Water is known to degrade the siloxane bonds linking matrix and fillers, which has been suggested to decrease the fracture toughness in conventional resin composi...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103674

    authors: Tiu J,Belli R,Lohbauer U

    更新日期:2020-04-01 00:00:00

  • Experimental validation of finite element model for proximal composite femur using optical measurements.

    abstract::Patient-specific finite element models have been used to predict femur strength and fracture risk in individuals. Validation of the adopted finite element modelling procedure against mechanical testing data is a crucial step when aiming for clinical applications. The majority of the works available in literature used ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.02.006

    authors: Grassi L,Väänänen SP,Amin Yavari S,Weinans H,Jurvelin JS,Zadpoor AA,Isaksson H

    更新日期:2013-05-01 00:00:00

  • Packing of muscles in the rabbit shank influences three-dimensional architecture of M. soleus.

    abstract::Isolated and packed muscles (e.g. in the calf) exhibit different three-dimensional muscle shapes. In packed muscles, cross-sections are more angular compared to the more elliptical ones in isolated muscles. As far as we know, it has not been examined yet, whether the shape of the muscle in its packed condition influen...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.04.006

    authors: Wick C,Böl M,Müller F,Blickhan R,Siebert T

    更新日期:2018-07-01 00:00:00

  • A statistical approach to understand the role of inclusions on the fatigue resistance of superelastic Nitinol wire and tubing.

    abstract::Superelastic wires and diamond-shaped stent surrogates were manufactured from Nitinol rods and tubing, respectively, from five different mill product suppliers - Standard VAR, Standard VIM, Standard VIM+VAR, Process-Optimized VIM+VAR, and High-Purity VAR. High-cycle fatigue tests up to 10(7) cycles were conducted unde...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.07.003

    authors: Robertson SW,Launey M,Shelley O,Ong I,Vien L,Senthilnathan K,Saffari P,Schlegel S,Pelton AR

    更新日期:2015-11-01 00:00:00

  • Tribological behavior of Ti-6Al-4V against cortical bone in different biolubricants.

    abstract::Titanium alloys (Ti-6Al-4V) are promising materials as bone implants in clinical surgeries owing to their excellent performances. However, wear debris caused by the tribological behavior of the cortical bone and titanium alloy interface were found to be paramount for implant stability. The contact environment between ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.10.031

    authors: Wang C,Zhang G,Li Z,Zeng X,Xu Y,Zhao S,Hu H,Zhang Y,Ren T

    更新日期:2019-02-01 00:00:00

  • Fatigue life of bovine meniscus under longitudinal and transverse tensile loading.

    abstract::The knee meniscus is composed of a fibrous extracellular matrix that is subjected to large and repeated loads. Consequently, the meniscus is frequently torn, and a potential mechanism for failure is fatigue. The objective of this study was to measure the fatigue life of bovine meniscus when applying cyclic tensile loa...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.12.020

    authors: Creechley JJ,Krentz ME,Lujan TJ

    更新日期:2017-05-01 00:00:00

  • Alternative processing methods of hybrid porous scaffolds based on gelatin and chitosan.

    abstract::The present work focuses on the development of scaffolds based on gelatin and chitosan using different protocols based on the general processing of phase separation, derived from the fabrication of hydrogels and freeze-drying. The scaffolds were produced with 1 wt% of two different biopolymers, i.e. gelatin (GE) and c...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103472

    authors: Perez-Puyana V,Rubio-Valle JF,Jiménez-Rosado M,Guerrero A,Romero A

    更新日期:2020-02-01 00:00:00

  • Effect of size and dimensional tolerance of reverse total shoulder arthroplasty on wear: An in-silico study.

    abstract::Although huge research efforts have been devoted to wear analysis of ultra-high molecular weight polyethylene (UHMWPE) in hip and knee implants, shoulder prostheses have been studied only marginally. Recently, the authors presented a numerical wear model of reverse total shoulder arthroplasties (RTSAs), and its applic...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.03.033

    authors: Mattei L,Di Puccio F,Joyce TJ,Ciulli E

    更新日期:2016-08-01 00:00:00

  • On the mechanical characterization and modeling of polymer gel brain substitute under dynamic rotational loading.

    abstract::The use of highly sensitive soft materials has become increasingly apparent in the last few years in numerous industrial fields, due to their viscous and damping nature. Unfortunately these materials remain difficult to characterize using conventional techniques, mainly because of the very low internal forces supporte...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.06.008

    authors: Fontenier B,Hault-Dubrulle A,Drazetic P,Fontaine C,Naceur H

    更新日期:2016-10-01 00:00:00

  • Fracture origins in twenty-two dental alumina crowns.

    abstract:OBJECTIVES:The causes of in vivo fractures of all-ceramic dental crowns are not yet fully understood. The fracture origins often occur in the cervical margin in the approximal area, but the reason for this is unclear. The aim of this study was to evaluate the fracture origin of 22 of clinically-failed alumina crowns. ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.08.006

    authors: Øilo M,Quinn GD

    更新日期:2016-01-01 00:00:00

  • Thickness optimization of auricular silicone scaffold based on finite element analysis.

    abstract::An optimized thickness of a transplantable auricular silicone scaffold was researched. The original image data were acquired from CT scans, and reverse modeling technology was used to build a digital 3D model of an auricle. The transplant process was simulated in ANSYS Workbench by finite element analysis (FEA), solid...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.08.032

    authors: Jiang T,Shang J,Tang L,Wang Z

    更新日期:2016-01-01 00:00:00

  • Thermo-mechanical behavior and structure of melt blown shape-memory polyurethane nonwovens.

    abstract::New processing methods for shape-memory polymers allow for tailoring material properties for numerous applications. Shape-memory nonwovens have been previously electrospun, but melt blow processing has yet to be evaluated. In order to determine the process parameters affecting shape-memory behavior, this study examine...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.05.038

    authors: Safranski DL,Boothby JM,Kelly CN,Beatty K,Lakhera N,Frick CP,Lin A,Guldberg RE,Griffis JC

    更新日期:2016-09-01 00:00:00

  • In situ compressibility of carbonated hydroxyapatite in tooth dentine measured under hydrostatic pressure by high energy X-ray diffraction.

    abstract::Tooth dentine and other bone-like materials contain carbonated hydroxyapatite nanoparticles within a network of collagen fibrils. It is widely assumed that the elastic properties of biogenic hydroxyapatites are identical to those of geological apatite. By applying hydrostatic pressure and by in situ measurements of th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.06.005

    authors: Forien JB,Fleck C,Krywka C,Zolotoyabko E,Zaslansky P

    更新日期:2015-10-01 00:00:00

  • Nanoscopic dynamic mechanical properties of intertubular and peritubular dentin.

    abstract::An experimental evaluation of intertubular and peritubular dentin was performed using nanoindentation and Dynamic Mechanical Analysis (DMA). The objective of the investigation was to evaluate the differences in dynamic mechanical behavior of these two constituents and to assess whether their response is frequency depe...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.08.010

    authors: Ryou H,Romberg E,Pashley DH,Tay FR,Arola D

    更新日期:2012-03-01 00:00:00