Evaluation of multi-scale mineralized collagen-polycaprolactone composites for bone tissue engineering.

Abstract:

:A particular challenge in biomaterial development for treating orthopedic injuries stems from the need to balance bioactive design criteria with the mechanical and geometric constraints governed by the physiological wound environment. Such trade-offs are of particular importance in large craniofacial bone defects which arise from both acute trauma and chronic conditions. Ongoing efforts in our laboratory have demonstrated a mineralized collagen biomaterial that can promote human mesenchymal stem cell osteogenesis in the absence of osteogenic media but that possesses suboptimal mechanical properties in regards to use in loaded wound sites. Here we demonstrate a multi-scale composite consisting of a highly bioactive mineralized collagen-glycosaminoglycan scaffold with micron-scale porosity and a polycaprolactone support frame (PCL) with millimeter-scale porosity. Fabrication of the composite was performed by impregnating the PCL support frame with the mineral scaffold precursor suspension prior to lyophilization. Here we evaluate the mechanical properties, permeability, and bioactivity of the resulting composite. Results indicated that the PCL support frame dominates the bulk mechanical response of the composite resulting in a 6000-fold increase in modulus compared to the mineral scaffold alone. Similarly, the incorporation of the mineral scaffold matrix into the composite resulted in a higher specific surface area compared to the PCL frame alone. The increased specific surface area in the collagen-PCL composite promoted increased initial attachment of porcine adipose derived stem cells versus the PCL construct.

authors

Weisgerber DW,Erning K,Flanagan CL,Hollister SJ,Harley BAC

doi

10.1016/j.jmbbm.2016.03.032

subject

Has Abstract

pub_date

2016-08-01 00:00:00

pages

318-327

eissn

1751-6161

issn

1878-0180

pii

S1751-6161(16)30052-2

journal_volume

61

pub_type

杂志文章
  • New regime in the mechanical behavior of skin: strain-softening occurring before strain-hardening.

    abstract::We report linear and non-linear shear tests on rat skin, evidencing a strain-softening regime, from 1% to 50% strain, followed by a strong strain-hardening regime, leading to a 'deck chair-shaped' stress-strain curve. The strain-softening regime was never reported as such in the literature, possibly mistaken for the l...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.12.021

    authors: Nicolle S,Decorps J,Fromy B,Palierne JF

    更新日期:2017-05-01 00:00:00

  • µ-Particle tracking velocimetry and computational fluid dynamics study of cell seeding within a 3D porous scaffold.

    abstract::Cell seeding of 3D scaffolds is a critical step in tissue engineering since the final tissue properties are related to the initial cell distribution and density within the scaffold unit. Perfusion systems can transport cells to the scaffold however; the fact that cells flow inside the scaffold pores does not guarantee...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.08.003

    authors: Marin AC,Grossi T,Bianchi E,Dubini G,Lacroix D

    更新日期:2017-11-01 00:00:00

  • Compliance mismatch and compressive wall stresses drive anomalous remodelling of pulmonary trunks reinforced with Dacron grafts.

    abstract::Synthetic grafts are often satisfactory employed in cardiac and vascular surgery, including expanded poly(ethylene terephthalate) or expanded poly(tetrafluoroethylene). However, accumulating evidences suggest the emergence of worrisome issues concerning the long-term fate of prosthetic grafts as large vessel replaceme...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.06.023

    authors: Nappi F,Carotenuto AR,Cutolo A,Fouret P,Acar C,Chachques JC,Fraldi M

    更新日期:2016-10-01 00:00:00

  • Relationships between the morphology, swelling and mechanical properties of poly(dimethyl siloxane)/poly(acrylic acid) interpenetrating networks.

    abstract::A limitation in the use of hydrophilic polymers as implantable devices is their inherently poor mechanical strength. Using interpenetrating polymer networks (IPNs) consisting of both hydrophilic and hydrophobic networks is an effective method of strengthening these polymers. In this work, a series of poly(dimethyl sil...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2009.01.002

    authors: Jalili K,Abbasi F,Oskoee SS,Alinejad Z

    更新日期:2009-10-01 00:00:00

  • Micromechanisms of fatigue crack growth in polycarbonate polyurethane: Time dependent and hydration effects.

    abstract::Polycarbonate polyurethane has cartilage-like, hygroscopic, and elastomeric properties that make it an attractive material for orthopedic joint replacement application. However, little data exists on the cyclic loading and fracture behavior of polycarbonate polyurethane. This study investigates the mechanisms of fatig...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.01.008

    authors: Ford AC,Gramling H,Li SC,Sov JV,Srinivasan A,Pruitt LA

    更新日期:2018-03-01 00:00:00

  • Towards intervertebral disc engineering: Bio-mimetics of form and function of the annulus fibrosus lamellae.

    abstract::The aging western society is heavily afflicted with intervertebral disc (IVD) degeneration. Replacement or repair of the degenerated IVD with an artificial bio-mimetic construct is one of the challenges of future research due to its complex structure and unique biomechanical function. Herein, biocomposite laminates ma...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.023

    authors: Sharabi M,Wertheimer S,Wade KR,Galbusera F,Benayahu D,Wilke HJ,Haj-Ali R

    更新日期:2019-06-01 00:00:00

  • The effect of Equal Channel Angular Pressing on the stress corrosion cracking susceptibility of AZ31 alloy in simulated body fluid.

    abstract::Despite the great potential of Mg and its alloys as material for biodegradable implants, their low resistance to the simultaneous action of corrosion and mechanical stresses in the human body have hampered their use. Stress Corrosion Cracking has been reported as one of the most critical failure modes to overcome to a...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2020.103724

    authors: Peron M,Skaret PC,Fabrizi A,Varone A,Montanari R,Roven HJ,Ferro P,Berto F,Torgersen J

    更新日期:2020-06-01 00:00:00

  • Human enamel rod presents anisotropic nanotribological properties.

    abstract::The AFM combined nanoindentation was performed to observe the ultrastructure of enamel rod from various section plans and positions while probing their mechanical and tribological properties of the area. The nanohardness and the elastic modulus of the head region of the enamel rods are significantly higher than that o...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2010.12.002

    authors: Jeng YR,Lin TT,Hsu HM,Chang HJ,Shieh DB

    更新日期:2011-05-01 00:00:00

  • A method and a device for the evaluation of the retention of telescopic dental crowns.

    abstract::Telescopic crowns are used as support for removable dental prostheses' construction. A distinctive feature of crowns often used in their description and comparison is retention, which is understood as resistance when removing the prosthesis or a force needed to disconnect crowns. The article describes a method for the...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.01.042

    authors: Majcher A,Leśniewska-Kochanek A,Mierzwińska-Nastalska E

    更新日期:2017-05-01 00:00:00

  • Utilization of a robotic mount to determine the force required to cut palatal tissue.

    abstract::Determination of the material properties of soft tissue is a growing area of interest that aids in the development of new surgical tools and surgical simulators. This study first aims to develop a robot-operated tissue testing system for determination of tissue cutting forces. Second, this system was used to ascertain...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.06.010

    authors: Sorouri K,Podolsky DJ,Wang AMQ,Fisher DM,Wong KW,Looi T,Drake JM,Forrest CR

    更新日期:2018-10-01 00:00:00

  • Failure analysis of the fractured wires in sternal perichronal loops.

    abstract::We report failure analysis of sternal wires in two cases in which a perichronal fixation technique was used to close the sternotomy. Various characteristics of the retrieved wires were compared to those of unused wires of the same grade and same manufacturer and with surgical wire specifications. In both cases, wire f...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.02.015

    authors: Chao J,Voces R,Peña C

    更新日期:2011-10-01 00:00:00

  • Influence of cold rolling and ageing treatment on microstructure and mechanical properties of Ti-30Nb-5Ta-6Zr alloy.

    abstract::In this study, the relationship between deformation mechanism and rolling reductions was investigated, and the effects of deformation reductions on the microstructure and mechanical properties of the alloys both cold rolled and aged were revealed. It was found that the equiaxed β grains of the Ti-30Nb-5Ta-6Zr alloy ha...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.06.006

    authors: Wang Y,Zhao J,Dai S,Chen F,Yu X,Zhang Y

    更新日期:2013-11-01 00:00:00

  • Fracture resistance of CAD/CAM occlusal veneers: A systematic review of laboratory studies.

    abstract:OBJECTIVE:The purpose of this systematic review was to summarize scientific evidence that evaluates in vitro fracture and fatigue strength of occlusal veneers in different thicknesses, CAD/CAM materials, and under different aging methodologies. MATERIALS AND METHODS:An electronic search of 3 English databases (The Nat...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章,评审

    doi:10.1016/j.jmbbm.2020.103948

    authors: Albelasy EH,Hamama HH,Tsoi JKH,Mahmoud SH

    更新日期:2020-10-01 00:00:00

  • Biomechanical test protocols to detect minor injury effects in intervertebral discs.

    abstract::Intervertebral discs (IVDs) maintain flexibility of the spine and bear mechanical load. Annulus fibrosus (AF) defects are associated with IVD degeneration and herniation which disrupt biomechanical function and can cause pain. AF puncture injuries can induce IVD degeneration but are needed to inject therapies. Identif...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.024

    authors: Torre OM,Evashwick-Rogler TW,Nasser P,Iatridis JC

    更新日期:2019-07-01 00:00:00

  • Effect of grinding with diamond-disc and -bur on the mechanical behavior of a Y-TZP ceramic.

    abstract::This study compared the effects of grinding on the surface micromorphology, phase transformation (t→m), biaxial flexural strength and structural reliability (Weibull analysis) of a Y-TZP (Lava) ceramic using diamond-discs and -burs. 170 discs (15×1.2mm) were produced and divided into 5 groups: without treatment (Ctrl,...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2014.05.010

    authors: Pereira GK,Amaral M,Simoneti R,Rocha GC,Cesar PF,Valandro LF

    更新日期:2014-09-01 00:00:00

  • Fabrication, tribological and corrosion behaviors of ultra-fine grained Co-28Cr-6Mo alloy for biomedical applications.

    abstract::Nickel and carbides free Co-28Cr-6Mo alloy was fabricated by combination of mechanical alloying and warm pressing. The microstructure, mechanical properties, pin-on-disk dry sliding wear and corrosion behavior in simulated physiological solution were investigated. The produced Co-28Cr-6Mo alloy has elongated ultra-fin...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.12.039

    authors: Ren F,Zhu W,Chu K

    更新日期:2016-07-01 00:00:00

  • Variation of the superelastic properties and nickel release from original and reused NiTi orthodontic archwires.

    abstract::Reuse of NiTi orthodontic wires has become increasingly common in dental clinics. For sterilization and recovery of the original superelastic properties of the wires, a heat treatment is usually performed between 500 and 600 °C. The aim of this study was to analyze the effect of these thermal treatments on the mechani...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.11.005

    authors: Gil FJ,Espinar E,Llamas JM,Manero JM,Ginebra MP

    更新日期:2012-02-01 00:00:00

  • Novel microstructural findings in M. plantaris and their impact during active and passive loading at the macro level.

    abstract::There are several studies dealing with experimental and structural analyses of skeletal muscles that are aimed at gaining a better understanding of three-dimensional muscle deformation and force generation. A variety of these contributions have performed structural or mechanical analyses, but very few have combined th...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.06.026

    authors: Böl M,Leichsenring K,Ernst M,Wick C,Blickhan R,Siebert T

    更新日期:2015-11-01 00:00:00

  • Comparison of structural anisotropic soft tissue models for simulating Achilles tendon tensile behaviour.

    abstract::The incidence of tendon injury (tendinopathy) has increased over the past decades due to greater participation in sports and recreational activities. But little is known about the aetiology of tendon injuries because of our limited knowledge in the complex structure-function relationship in tendons. Computer models ca...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.04.007

    authors: Khayyeri H,Longo G,Gustafsson A,Isaksson H

    更新日期:2016-08-01 00:00:00

  • Measurement of viscoelastic properties in multiple anatomical regions of acute rat brain tissue slices.

    abstract::Mechanical property data for brain tissue are needed to understand the biomechanics of neurological disorders and response of the brain to different mechanical and surgical forces. Most studies have characterized mechanical behavior of brain tissues over large regions or classified tissue properties for either gray or...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2013.08.026

    authors: Lee SJ,King MA,Sun J,Xie HK,Subhash G,Sarntinoranont M

    更新日期:2014-01-01 00:00:00

  • Effect of Cu on microstructure, mechanical properties, corrosion resistance and cytotoxicity of CoCrW alloy fabricated by selective laser melting.

    abstract::In the study, CoCrWCu alloys with differing Cu content (2, 3, 4 wt%) were prepared by selective laser melting using mixture powders consisting of CoCrW and Cu, aiming at investigating the effect of Cu on the microstructures, mechanical properties, corrosion behavior and cytotoxicity. The SEM observations indicated tha...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.02.026

    authors: Lu Y,Ren L,Xu X,Yang Y,Wu S,Luo J,Yang M,Liu L,Zhuang D,Yang K,Lin J

    更新日期:2018-05-01 00:00:00

  • Performance analysis of grafted poly (2-methacryloyloxyethyl phosphorylcholine) on additively manufactured titanium substrate for hip implant applications.

    abstract::The incidence of total hip arthroplasty (THA) has been evidently growing over the last few decades. Surface modification, such as polymer grafting onto implant surfaces using poly (2-methacryloyloxyethyl phosphorylcholine) (PMPC), has been gaining attention due to its excellent biocompatibility and high lubricity beha...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.103412

    authors: Ghosh S,Abanteriba S,Wong S,Houshyar S

    更新日期:2019-12-01 00:00:00

  • "Force-from-lipids" gating of mechanosensitive channels modulated by PUFAs.

    abstract::The level of fatty acid saturation in phospholipids is a crucial determinant of the biophysical properties of the lipid bilayer. Integral membrane proteins are sensitive to changes of their bilayer environment such that their activities and localization can be profoundly affected. When incorporated into phospholipids ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2017.12.026

    authors: Ridone P,Grage SL,Patkunarajah A,Battle AR,Ulrich AS,Martinac B

    更新日期:2018-03-01 00:00:00

  • A constitutive law for degrading bioresorbable polymers.

    abstract::This paper presents a constitutive law that predicts the changes in elastic moduli, Poisson's ratio and ultimate tensile strength of bioresorbable polymers due to biodegradation. During biodegradation, long polymer chains are cleaved by hydrolysis reaction. For semi-crystalline polymers, the chain scissions also lead ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2016.02.026

    authors: Samami H,Pan J

    更新日期:2016-06-01 00:00:00

  • Damage initiation and progression in the cartilage surface probed by nonlinear optical microscopy.

    abstract::With increasing interest in treating osteoarthritis at its earliest stages, it has become important to understand the mechanisms by which the disease progresses across a joint. Here, second harmonic generation (SHG) microscopy, coupled with a two-dimensional spring-mass network model, was used to image and investigate...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2011.08.004

    authors: Brown CP,Houle MA,Chen M,Price AJ,Légaré F,Gill HS

    更新日期:2012-01-01 00:00:00

  • Effect of cell sample size in atomic force microscopy nanoindentation.

    abstract::Single-cell technologies are powerful tools to evaluate cell characteristics. In particular, Atomic Force Microscopy (AFM) nanoindentation experiments have been widely used to study single cell mechanical properties. One important aspect related to single cell techniques is the need for sufficient statistical power to...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2019.03.018

    authors: Marcotti S,Reilly GC,Lacroix D

    更新日期:2019-06-01 00:00:00

  • Mechanical characterization and modelling of the temperature-dependent impact behaviour of a biocompatible poly(L-lactide)/poly(ε-caprolactone) polymer blend.

    abstract::Poly(ε-caprolactone) (PCL) is a ductile, bioabsorbable polymer that has been employed as a blend partner for poly(L-lactic acid) (PLLA). An improvement of the material strength and impact resistance of PLLA/PCL polymer blends compared to pure PLLA has been shown previously. To use numerical simulations in the design p...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2015.07.007

    authors: Gustafsson G,Nishida M,Ito Y,Häggblad HÅ,Jonsén P,Takayama T,Todo M

    更新日期:2015-11-01 00:00:00

  • Reduction of load-bearing capacity of all-ceramic crowns due to cement aging.

    abstract::The purpose of this study was to investigate how water aging of the resin cement influences the stress distribution in all-ceramic crowns and if there is an increase in the propensity for crown failure. The failure of all-ceramic crowns attributed to cement degradation was explored using a combination of experimental ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.08.003

    authors: Lu C,Wang R,Mao S,Arola D,Zhang D

    更新日期:2013-01-01 00:00:00

  • FT-Raman spectroscopic study of human skin subjected to uniaxial stress.

    abstract::Fourier Transform Raman Spectroscopy was used to investigate the molecular changes of structural proteins in human skin subjected to strain. In the Raman spectrum of unstrained skin, bands assigned mainly to collagen and elastin were observed at 1658 cm(-1) (amide I), 1271 and 1255 cm(-1) (amide III), and 935 and 817 ...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2012.11.023

    authors: Gąsior-Głogowska M,Komorowska M,Hanuza J,Mączka M,Zając A,Ptak M,Będziński R,Kobielarz M,Maksymowicz K,Kuropka P,Szotek S

    更新日期:2013-02-01 00:00:00

  • Mechanical performance of Y-TZP monolithic ceramic after grinding and aging: Survival estimates and fatigue strength.

    abstract::This study aims to evaluate the flexural fatigue strength and survival estimates of an Y-TZP monolithic ceramic after grinding and aging. Ceramic discs (1.2 mm thickness × 15.0 mm diameter - ISO, 6872, 2015) of zirconia (Zirlux FC2 - Ardent; Ivoclar Vivadent) were made and randomly allocated into 6 groups (n = 10), ac...

    journal_title:Journal of the mechanical behavior of biomedical materials

    pub_type: 杂志文章

    doi:10.1016/j.jmbbm.2018.07.041

    authors: Dapieve KS,Guilardi LSF,Silvestri T,Rippe MP,Pereira GKR,Valandro LF

    更新日期:2018-11-01 00:00:00